![](/html/5a/5a96/5a966ba7dc0aa80565e3073a002a6fc55e89f3a6c27104e548e5f49a9d0ddfc4/bg1.png)
PORTABLE STROBOSCOPES (external phase-shifting)
5
Phaser-Strobe pbx
The Phaser-S trobe pbx incorporate the unique design features of the Nova-Strobe dbx with an increased
operating range of 30 to 50,000 flashes per minute, as well as external phase- shifting. The unique
digital adjustment knob can select the decade for adjustments, so coarse and fine adjustments of flash
rates are made quickly and with significantly better resolution than competitive units. The memory
feature of the Phaser-Strobe pbx allows nine flash rates to be stored - displayed in flashes per minute
or flashes per second. Phaser-Strobe pbx operates with internal rechargeable batteries or continuously
from AC line power with the power supply/recharger.
Features:
• N.I.S.T. Traceable Certificate of Calibration included
• Phase Shift adjustable as phase angle or time with resolution to 0.01º and 0.01 msec
• Virtual RPM mode provides slow motion viewing for high speed events
• Backlit alphanumeric LCD shows flash rate, degrees, time
• Store and recall nine memory settings
• TTL compatible input/output jacks, power for optional sensors
• Tachometer mode from Remote Sensors (see page 9)
Remote Optical Sensor
(ROS-P) Gap 36 inches
Specifications Phaser-Strobe pbx
Flash Range 30-50,000 FPM (Flashes/Minute) 0.5-830 FPS (Flashes/Sec) (Hz)
Accuracy ±0.002% of Setting +/- least significant digit
Digital Adjustment Knob 36 detents per revolution and blinking decade selection
Flash Rate Resolution 0.01 to 1.0 FPM (Menu Selectable)
(Internal Triggering)
Update Time Instantaneous
Phase Delay - Degrees 0.1 to 359.9 degrees
Time Delay - Seconds 0.01 to 1000 msec.
Virtual RPM (Slow Motion) 0-200 VRPM
Flash Energy (Typical) 230mJoule up to 3450 FPM
Flash Duration (Typical) 8-20 usec
Average Power - Watts 11W @ 3000 FPM; >13W @ 3450 FPM
Tachometer Mode 5-250,000 RPM from external trigger
External Input Input Pulse - 0.5 usec min, TTL to 24V max (1/8" phone plug)
Trigger Output/Remote Sync 3.3V TTL Compatible 40 usec pulse-Positive/Negative
Power Internal rechargeable batteries with AC power supply/recharger
Weight 1.9 Lbs. (0.85 kg) including batteries
Remote Magnetic Sensor
(MT-190-P) Gap 0.25 inches
Remote Infrared Sensor
(IRS-P) Gap 0.50 inches
R oHS NIST
Phaser-Strobe pbx
Ordering Information
Phaser-Strobe pbx 115/230 - Stroboscope with
PSC-pbxU (115/230 Vac) Power Supply/
Recharger
Phaser-Strobe pbx Kit 115/230 - Same as
above with Spare Lamp and Latching Carrying
Case
Common Applications:
• Calibration of Tachometers
• Diagnostic Inspection
• Engine R&D
• Textiles
• Centrifuges
• Shaker Tables
PORTABLE STROBOSCOPES (for use with Vibration Data Collectors)
Vibration-Strobe VB
Vibration Strobe is uniquely designed to provide precise, instantaneous synchronization to a number of data collectors and FFT Analyzers triggered by an accelerometer. Built for rugged, portable
applications, the Vibration Strobe is the perfect lightweight phase analysis tool. Vibration Strobe
allows for the measurement of phase without stopping the machinery to install reflective tape. Phase
analysis is quick and accurate using the Filter Bandwidth Selector and the Relative Phase Adjustment. Unique “Tracking Filter” maintains phase lock to input pulse.
Kits include: Strobe, interface cable, fast recharger and spare lamp in latching carrying case.
Specifications Vibration Strobe
Flash Range 100-12,000 Flashes Per Minute (FPM)
Display 5-Digit Backlit Liquid Crystal Display
Accuracy ± 1 FPM
Flash Energy 180 mJoule
Flash Duration (typical) 30 μSec.
Lamp Life (typical) 100 million flashes
External Trigger TTL (24V max) provides 5V out
Tracking Filter Selectable Wide and Narrow Bandwidths
Operating Time 60 minutes at 6,000 FPM
Relative Phase Adjustment Selectable -90° to +90°
Power 6 Vdc, Internal Rechargeable Batteries; 115Vac, 50-400 Hz
or 220-240 Vac, 50-400 Hz Fast Charger
Weight 2.5 Lbs. (1.1 kg)
Vibration Strobe VB-115
Ordering Information
Contact Factory for available Models.