[EN] RKZ012A105
EN-1
WIRELESS LAN INTERFACE MAIN
UNIT INSTALLATION MANUAL
• This INSTALLATION MANUAL can also be viewed on
the home page of MITSUBISHI HEAVY INDUSTRIES
THERMAL SYSTEMS, LTD.
• Please download USER’S MANUAL (including the
guarantee form) via the QR code or from the home
page described later.
Safety precautions Please read these safety precautions
carefully before installing and using this product.
● Be sure to follow these precautions because they
describe important safety-related information.
Failure to follow warnings may cause
serious consequences such as death
or severe injury.
Failure to follow cautions may cause
injury and/or property damage.
Depending on the situation, failure to
follow cautions may lead to serious
consequences.
● The "graphic symbols" in this document have the
following meanings.
Be sure to follow instructions.
● After the installation work is completed, check the
installation according to the installation work check
items. Request your customer to keep this installation
manual at the customer’s site.

● Do not bundle, roll, or step on connection
cables to prevent cables from becoming
deformed.
(Deformation may cause heat generation, fire,
or electric shocks due to loose connection,
insulation failure, current exceeding the
allowable limit, etc.)
● Do not install this product near automatic
control equipment such as an automatic door
or fire-alarm device.
(Such improper installation may cause an
accident due to malfunction of equipment.)
● Do not install this product at a location in
a hospital, etc. where the use of wireless
devices is prohibited.
(Such improper installation may cause
malfunction of medical equipment due to a
wireless device.)
● Do not use this product near a person with a
cardiac pacemaker or implanted defibrillator.
(Such improper use may cause malfunction of
a medical device.)
● Do not disassemble, modify, or repair this
product.
(Such an activity may cause an electric shock,
fire, or any injury.)
● For installation work, request the sales outlet
for the product or an authorized dealer to
install the product.
(Improper installation may cause a water
leakage, electric shock, or fire.)

● In the installation work, install the product
securely according to this installation manual,
and be sure to use accessories and specified
parts for installation.
(Improper installation may cause a water
leakage, electric shock, or fire.)
● The electrical engineering work must be
performed by a qualified electrical worker
according to the technical standards
concerning electrical equipment, interior
wiring regulation, and installation manual.
(Improper work may cause an electric shock
or fire.)
● For wiring, use the specified cable, and
connect the cable securely. Then, fix the
terminal connection part securely to prevent
external force from being transmitted to the
connection part through the cable.
(Improper connection may cause any failure,
heat generation, or fire.)
● Before installation, unplug the main unit of the
air-conditioner.
(Installation work without unplugging the
equipment may cause an electrical shock.)
● When you unplug the connection cable, hold
the connector to unplug the cable.
(Improper work may cause an electric shock
or fire.)

● Do not use the product near another wireless
device, microwave, cordless phone, fax
machine, etc.
(Improper use may cause malfunction.)
● To prevent any failure due to electrical
discharge, touch your hand with metal around
you to remove static electricity from your body
before you touch this product.
(Improper operation may cause any failure.)
● Be sure to keep dry because the product is
not waterproof.
(Improper connection may cause any failure,
heat generation, or fire.)

EN-5
1. Selecting the installation location and installing the
main body
<Selecting the installation location>
Install this product in a location that satisfies the following conditions with
the agreement of your customer.
● A location where this product is not exposed to direct sunlight
● A location where this product is not influenced by a heating device
such as a stove
● A location with no moisture, and where this product is not exposed to
water
● A location where this product is not exposed directly to oil droplets or
steam
● A location without projections or depressions on the installation
surface
● A location at least 1 m away from a TV set, stereo, or radio (the image
may be disturbed, and noise may be generated.)
● A location where this product is not influenced by a high-frequency or
electrical device

EN-6
<Cautions for installation>
● Do not mount the holder and main unit inside the indoor unit.
● Fix the holder on a wall, pillar, etc. securely with attached screws. (Do
not mount it on a clay wall, etc.)
● Install the connection cable securely by sliding the main unit from
above to prevent the cable from being trapped in the holder.
● Install the main unit within the range where the connection cable can
reach the indoor unit.
(The length of the connection cable is about 1.3 m.)
● Never extend the connection cable because this product may fail to
operate normally if the cable is extended.
● Is it possible to remove the main unit and holder?
<When installing the holder and main unit inside an
indoor unit in which they can be included>
● Do not install them inside an indoor unit, except when a unit can
include them.
Accessories supplied with this product
Check the accessories supplied with this
product.
Installation manual (this
document)
Holes for mounting the unit on a wall

EN-7
2. Connecting this product with the indoor unit
Connect the indoor unit connection cable to the indoor control printedcircuit board.
・ For the connection of the indoor unit, refer to the “description for
connecting the interface kit” in the installation manual of the indoor
unit.
・ Connect the connector of the indoor unit connection cable to the
terminal (CNS) on the indoor control board by installing the cable
along the wiring route from below.
・ Securely connect the connector of the indoor connection cable to
the CNS terminal on the indoor control board.
● About the handling of the connection cable
If the connection cable is too long, the redundant cable section
should be stored loosely in a space on the back of the indoor unit.

EN-8
After the installation work is completed, be sure
to check the following.
Installation work check items
□ Is the holder fixed securely?
□ Is the cable trapped? Is the connection cable under a load?
□ Is the connector connected properly and securely?
□ Did you forget to tighten a screw on the main body of the indoor unit?
□ Turn ON the power to the indoor unit. After that, do the
Communication LED and Running LED become ON for about
10 seconds and then OFF? (If the Communication LED and
Running LED blink alternately at intervals of 10 seconds, check the
connection.)
□ Did you pass the installation manual to your customer and request
the customer to thoroughly read and store the manual?
* If you have any question on the installation, please contact us at the URL
on the last page for inquiry.
Illuminates, and
then goes OFF
Short blinking is
repeated alternately

EN-9
Notes for users
● Before using the product, the user needs to install the dedicated
application.
The user needs to install the smartphone application and then set up
a connection with the interface. Set up a connection with the interface
according to the user's manual downloaded via the following QR
code or from the URL.
● The application is free. Communications charges are applied to
downloading and operation.
● The application name “Smart M-Air” and download service names
“Google Play” and “App Store” may be changed in the future.
How to install the “Smart M-Air” smartphone application
For Android
1. Open [Google Play].
2. Search for [Smart M-Air].
3. Install the application according
to the instructions on the screen.
For iOS (iPhone)
1. Open [App Store].
2. Search for [Smart M-Air].
3. Install the application according
to the instructions on the screen.
User's Manual
Refer to the home page of MITSUBISHI HEAVY
INDUSTRIES THERMAL SYSTEMS, LTD.
http://www.mhi-mth.co.jp/en/products/detail/air-conditioner_
users_manual.html
● CE Marking
Refer to the home page of MITSUBISHI HEAVY INDUSTRIES THERMAL
SYSTEMS, LTD.

EN-10
MITSUBISHI HEAVY INDUSTRIES THERMAL SYSTEMS, LTD.
2-3, Marunouchi 3-chome, Chiyoda-ku, Tokyo, 100-8332, Japan
http://www.mhi-mth.co.jp/en/
MITSUBISHI HEAVY INDUSTRIES AIR-CONDITIONING EUROPE, LTD.
5 The Square, Stockley Park, Uxbridge, Middlesex, UB11 1ET, United Kingdom
Tel : +44-333-207-4072
Fax: +44-333-207-4089
http://www.mhiae.com/
MHIAE SERVICES B.V.
Herikerbergweg 238, Luna ArenA, 1101 CM Amsterdam, Netherlands
P.O.Box 23393 1100 DW Amsterdam, Netherlands
Tel : +31-20-40-64-535
MITSUBISHI HEAVY INDUSTRIES AIR-CONDITIONERS AUSTRALIA, PTY. LTD.
Block E, 391 Park Road, Regents Park, NSW, 2143 PO BOX 3167, Regents Park, NSW, 2143
Tel : +61-2-8774-7500
Fax: +61-2-8774-7501
https://www.mhiaa.com.au