Air-Conditioners
SUZ-KA25, KA35, KA50, KA60, KA71VA2
SUZ-KA25, KA35VAH
INSTALLATION MANUAL
For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende Bedienungsanleitung
und die Installationsanleitung der Innenanlage gründlich durchlesen die Klimaanlage.
MANUEL D’INSTALLATION
Avant d’installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d’installation de l’appareil
intérieur pour une utilisation sûre et correcte.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het binnenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso correcto y seguro, lea detalladamente este manual y el manual de instalación de la unidad interior
antes de instalar la unidad de aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente il presente manuale ed il manuale d’installazione dell’unità
interna prima di installare il condizionatore d’aria.
EΓΧEIPIΔIO OΔHΓIΩN EΓKATAΣTAΣHΣ
Για σωστή και ασφαλή χρήση, διαβάστε προσεκτικά αυτό το εγχειρίδιο καθώς και το εγχειρίδιο εγκατάστασης
της εσωτερικής μονάδας, προτού εγκαταστήσετε τη μονάδα του κλιματιστικού.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade
interior antes de instalar o aparelho de ar condicionado.
INSTALLATIONSMANUAL
Læs af sikkerhedshensyn denne manual samt manualen til installation af indendørsenheden grundigt, før du
installerer klimaanlægget.
INSTALLATIONSMANUAL
Läs bruksanvisningen och inomhusenhetens installationshandbok noga innan luftkonditioneringen installeras
så att den används på ett säkert och korrekt sätt.
MONTAJ ELKİTABI
Emniyetli ve doğru kullanım için, klima cihazını monte etmeden önce bu kılavuzu ve iç ünite montaj kılavuzunu
tamamıyla okuyun.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для обеспечения безопасной и надлежащей эксплуатации внимательно прочтите данное руководство
и руководство по установке внутреннего прибора перед установкой кондиционера.
FOR INSTALLER
FÜR INSTALLATEURE
POUR L’INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L’INSTALLATORE
ΓΙΑ ΑΥΤΟΝ ΠΟΥ ΚΑΝΕΙ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ
PARA O INSTALADOR
TIL INSTALLATØREN
FÖR INSTALLATÖREN
MONTÖR İÇİN
ДЛЯ УСТАНОВИТЕЛЯ
English
Deutsch
Français
Nederlands
Español
Italiano
Eλληνικά
Português
Dansk
Svenska
Türkçe
Русский

Contents
1. The following should always be observed for safety . . . . . . . . . . . . . . . . . . . . 2
2. Selecting the installation location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3. Installation diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4. Drain piping for outdoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5. Refrigerant piping work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
6. Electrical work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
7. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1. The following should always be observed for safety
• Please provide an exclusive circuit for the air conditioner and do not connect other electrical appliances to it.
• Be sure to read “The following should always be observed for safety” before installing the air conditioner.
• Be sure to observe the cautions specifi ed here as they include important
items related to safety.
The indications and meanings are as follows.
•
Warning:
Could lead to death, serious injury, etc.
Caution:
Could lead to serious injury in particular environments when operated incorrectly.
Warning:
• Do not install it by yourself (customer).
Incomplete installation could cause injury due to fi re, electric shock, the
unit falling or leakage of water. Consult the dealer from whom you purchased the unit or special installer.
• Install the unit securely in a place which can bear the weight of the unit.
When installed in an insuffi cient strong place, the unit could fall causing
injured.
• Use the specifi ed wires to connect the indoor and outdoor units securely
and attach the wires fi rmly to the terminal board connecting sections so
the stress of the wires is not applied to the sections.
Incomplete connecting and fi xing could cause fi re.
• Do not use intermediate connection of the power cord or the extension
cord and do not connect many devices to one AC outlet.
It could cause a fi re or an electric shock due to defective contact, defective
insulation, exceeding the permissible current, etc.
Check that the refrigerant gas does not leak after installation has completed.
•
• Perform the installation securely referring to the installation manual.
Incomplete installation could cause a personal injury due to fi re, electric
shock, the unit falling or leakage of water.
• After reading this manual, be sure to keep it together with the instruction
manual in a handy place on the customer’s site.
: Indicates a part which must be grounded.
Warning:
Carefully read the labels affi xed to the main unit.
• Perform electrical work according to the installation manual and be sure to
use an exclusive circuit.
If the capacity of the power circuit is insufficient or there is incomplete
electrical work, it could result in a fi re or an electric shock.
• Attach the electrical part cover to the indoor unit and the service panel to
the outdoor unit securely.
If the electrical part cover in the indoor unit and/or the service panel in the
outdoor unit are not attached securely, it could result in a fi re or an electric
shock due to dust, water, etc.
• Be sure to use the part provided or specified parts for the installation
work.
The use of defective parts could cause an injury or leakage of water due to
a fi re, an electric shock, the unit falling, etc.
• Ventilate the room if refrigerant leaks during operation.
If the refrigerant comes in contact with a fl ame, poisonous gases will be
released.
When pumping down the refrigerant, stop the compressor before discon-
•
necting the refrigerant pipes. The compressor may burst if air etc. get into it.
Caution:
• Perform grounding.
Do not connect the ground wire to a gas pipe, water pipe arrester or telephone ground wire. Defective grounding could cause an electric shock.
• Do not install the unit in a place where an infl ammable gas leaks.
If gas leaks and accumulates in the area surrounding the unit, it could
cause an explosion.
• Install a ground leakage breaker depending on the installation place (where
it is humid).
If a ground leakage breaker is not installed, it could cause an electric
shock.
2. Selecting the installation location
2.1. Outdoor unit
• Where it is not exposed to strong wind.
• Where airfl ow is good and dustless.
• Where it is not exposed to rain and direct sunshine.
• Where neighbours are not annoyed by operation sound or hot air.
• Where rigid wall or support is available to prevent the increase of operation
sound or vibration.
• Where there is no risk of combustible gas leakage.
• When installing the unit at a high level, be sure to fi x the unit legs.
• Where it is at least 3 m away from the antenna of TV set or radio. (Otherwise,
images would be disturbed or noise would be generated.)
• Please install it in an area not affected by snowfall or blowing snow. In areas
with heavy snow, please install a canopy, a pedestal and/or some baffl e boards.
• Install the unit horizontally.
• Perform the drainage/piping work securely according to the installation
manual.
If there is a defect in the drainage/piping work, water could drop from the
unit and household goods could be wet and damaged.
• Fasten a fl are nut with a torque wrench as specifi ed in this manual.
When fastened too tight, a fl are nut may broken after a long period and
cause a leakage of refrigerant.
Caution:
Avoid the following places for installation where air conditioner trouble is liable to occur.
• Where there is too much machine oil.
• Salty environment as seaside areas.
• Hot-spring areas.
• Where sulfi de gas exists.
• Other special atmospheric areas.
The outdoor unit produces condensate during the heating operation. Select the installation place to ensure to prevent the outdoor unit and/or the
grounds from being wet by drain water or damaged by frozen drain water.
2

3. Installation diagram
SUZ-KA25/KA35VA2
SUZ-KA25/KA35VAH
344.5
2-10 mm × 21 mm slot
SUZ-KA50/KA60VA2
285
3.1. Outdoor unit (Fig. 3-1)
Drainage hole (W42)
(In case of Heater models W33)
800
400
Air inlet
500
Air outlet
150
44
69
304 - 325
40
(mm)
Ventilation and service space
■ SUZ-KA25/KA35VA2
SUZ-KA25/KA35VAH
100 mm or more
A
B 350 mm or more
C Basically open 100 mm or more without any obstruction in front and on both
sides of the unit.
D 200 mm or more (Open two sides of left, right, or rear side.)
■ SUZ-KA50/KA60/KA71VA2
100 mm or more
A
B 350 mm or more
C 500 mm or more
When the piping is to be attached to a wall containing metals (tin plated) or metal
netting, use a chemically treated wooden piece 20 mm or thicker between the wall
and the piping or wrap 7 to 8 turns of insulation vinyl tape around the piping.
Units should be installed by licensed contractor accordingly to local code requirement.
Note:
When operating the air conditioner in low outside temperature, be sure to follow the instructions described below.
• Never install the outdoor unit in a place where its air inlet/outlet side may be exposed directly to wind.
• To prevent exposure to wind, install the outdoor unit with its air inlet side facing
the wall.
• To prevent exposure to wind, it is recommended to install a baffl e board on the
air outlet side of the outdoor unit.
SUZ-KA71VA2
840
34
Air inlet
500
Drainage 3 holes
(ø33)
51
Air inlet
330
515
299
66
Air outlet
4. Drain piping for outdoor unit (Fig. 4-1)
SUZ-KA25/35VA2
Drain socket
(For VA2 type only)
1
Fig. 4-1
40
Drain hose
81
360
4-10 mm × 21 mm slot
3
(mm)
Fig. 3-1
81
40
2-10 mm × 21 mm slot
330
(mm)
360
Air inlet
840
417.5
Air inlet
50
Air outlet
500175
Drainage hole
(W42)
4.1. Accessories
Check the following parts before installation.
<Outdoor unit>
1
Drain socket (for VA2 type only) 1
Drain cap ø33 (for SUZ-KA50/KA60 only) 2
2
• Provide drain piping before indoor and outdoor piping connection. (It will be hard
to install drain socket
prior to drain piping as outdoor unit becomes immovable.)
• Connect the drain hose
shown in the fi
• Make sure to provide drain piping with a downhill grade for easy drain fl ow.
Note:
Do not use the drain socket
makes the fan stop.
1
if indoor and outdoor piping connection is conducted
3
gure for drainage.
(obtainable at a store, inside diameter: 15 mm) as
1
in the cold region. Drain may freeze and it
3