SELECTION OF INSTALLATION LOCATION
Indoor unit
Outdoor unit
(Install at location that meets the following conditions, after getting approval from the customer)
○Where there is no obstructions to the air flow and where the cooled and heated air can be evenly distributed.
○A solid place where the unit or the wall will not vibrate.
○A place where there will be enough space for servicing. (Where space mentioned right can be secured)
○Where wiring and the piping work will be easy to conduct.
○The place where receiving part is not exposed to the direct rays of the sun or the strong rays of the street
lighting.
○A place where it can be easily drained.
○A place separated at least 1m away from the TV or the radio. (To prevent interference to images and
sounds.)
○Places where this unit is not affected by the high frequency equipment or electric equipment.
○Avoid installing this unit in place where there is much oil mist.
○Places where there is no electric equipment or household under the installing unit.
○A place where the air conditioner can be received the signal surely during operating the wireless remote
control.
○Places where there is no affected by the TV and radio etc.
○Do not place where exposed to direct sunlight or near heat devices such as a stove.
○Where air is not trapped.
○Where the installation fittings can be firmly installed.
○Where wind does not hinder the intake and outlet pipes.
○Out of the heat range of other heat sources.
○A place where stringent regulation of electric noises is applicable.
○Where it is safe for the drain water to be discharged.
○Where noise and hot air will not bother neighboring residents.
○Where snow will not accumulate.
○Where strong winds will not blow against the outlet pipe.
○
When the unit is installed, the space of the following dimension and above shall be secured.
In case the barrier is 1.2m or above in height, or is overhead, the sufficient space between
the unit and wall shall be secured.
RLC012A001A
WALL TYPE AIR CONDITIONER
R410A REFRIGERANT USED
Wireless remote control
WA
RNING
• Installation must be carried out by the qualified installer.
If you install the system by yourself, it may cause serious trouble such as water leaks,
electric shocks, fire and personal injury, as a result of a system malfunction. Do not carry
out the installation and maintenance work except the by qualified installer.
• Install the system in full accordance with the installation manual.
Incorrect installation may cause bursts, personal injury, water leaks, electric shocks and fire.
• Be sure to use only for household and residence.
If this appliance is installed in inferior environment such as machine shop and etc., it can
cause malfunction.
• Use the original accessories and the specified components for installation.
If parts other than those prescribed by us are used, It may cause water leaks, electric
shocks, fire and personal injury.
• Install the unit in a location with good support.
Unsuitable installation locations can cause the unit to fall and cause material damage and
personal injury.
• Ensure the unit is stable when installed, so that it can withstand
earthquakes and strong winds.
Unsuitable installation locations can cause the unit to fall and cause material damage and
personal injury.
• Ventilate the working area well in the event of refrigerant leakage during
installation.
If the density of refrigerant exceeds the limit, please consult the dealer and install the
ventilation system, otherwise lack of oxygen can occur, which can cause serious
accident.
• When installing in small rooms, take prevention measures not to exceed
the density limit of refrigerant in the event of leakage, referred by the
formula (accordance with ISO5149).
If the density of refrigerant exceeds the limit, please consult the dealer and install the
ventilation system, otherwise lack of oxygen can occur, which can cause serious accident.
• After completed installation, checkthat no refrigerant leaks from the system.
If refrigerant leaks into the room and comes into contact with an oven or other hot
surface, poisonous gas is produced.
• Use the prescribed pipes, flare nuts and tools for R410A.
Using existing parts (for R22 or R407C) can cause the unit failure and serious accidents
due to burst of the refrigerant circuit.
• Tighten the flare nut by torque wrench with specified method.
If the flare nut were tightened with excess torque, this may cause burst and refrigerant
leakage after a long period.
• Do not open the operation valves for liquid line and gas line until
completed refrigerant piping work, air tightness test and evacuation.
If the compressor is operated in state of opening operation valves before completed
connection of refrigerant piping work, air can be sucked into refrigerant circuit, which can
cause burst or personal injury due to anomalously high pressure in the refrigerant.
• The electrical installation must be carried out by the qualified electrician in
accordance with “the norm for electrical work” and “national wiring
regulation”, and the system must be connected to the dedicated circuit.
Power supply with insufficient capacity and incorrect function done by improper work
can cause electric shocks and fire.
• Be sure to shut off the power before starting electrical work.
Failure to shut off the power can cause electric shocks, unit failure or incorrect function
of equipment.
• Be sure to use the cables conformed to safety standard and cable ampacity
for power distribution work.
Unconformable cables can cause electric leak, anomalous heat production or fire.
• This appliance must be connected to main power supply by means of a circuit
breaker or switch (fuse:16A) with acontact separation of at least3mm.
• When plugging this appliance, a plug conforming to the norm IEC60884-1
must be used.
• Use the prescribed cables for electrical connection, tighten the cables
securely in terminal block and relieve the cables correctly to prevent
overloading the terminal blocks.
Loose connections or cable mountings can cause anomalous heat production or fire.
• Arrange the wiring in the control box so that it cannot be pushed up further
into the box. Install the service panel correctly.
Incorrect installation may result in overheating and fire.
• Be sure to fix up the service panels.
Incorrect fixing can cause electric shocks or fire due to intrusion of dust or water.
• Be sure to switch off the power supply in the event of installation,
inspection or servicing.
If the power supply is not shut off, there is a risk of electric shocks, unit failure or
personal injury due to the unexpected start of fan.
• Stop the compressor before removing the pipe after shutting the service
valve on pump down work.
If the pipe is removed when the compressor is in operation with the service valve open,
air would be mixed in the refrigeration circuit and it could cause explosion and injuries
due to abnormal high pressure in the cooling cycle.
• Only use prescribed option parts. The installation must be carried out by
the qualified installer.
If you install the system by yourself, it can cause serious trouble such as water leaks,
electric shocks, fire.
• Be sure to wear protective goggles and gloves while at work.
• Earth leakage breaker must be installed.
If the earth leakage breaker is not installed, it can cause electric shocks.
• Do not put the drainage pipe directly into drainage channels where
poisonous gases such as sulphide gas can occur.
Poisonous gases will flow into the room through drainage pipe and seriously affect the
user’s health and safety. This can also cause the corrosion of the indoor unit and a
resultant unit failure or refrigerant leak.
• Ensure that no air enters in the refrigerant circuit when the unit is installed
and removed.
If air enters in the refrigerant circuit, the pressure in the refrigerant circuit becomes too
high, which can cause burst and personal injury.
• Do not processing, splice the power cord, or share a socket with other
power plugs.
This may cause fire or electric shock due to defecting contact, defecting insulation and
over-current etc.
• Do not bundling, winding or processing for the power cord. Or, do not
deforming the power plug due to tread it.
This may cause fire or heating.
• Do not ventR410A into the atmosphere: R410A is a fluorinated greenhouse
gas, covered by the KyotoProtocol with Global Warming Potential(GWP)=1975.
• Do not run the unit with removed panels or protections.
T
ouching rotating equipments, hot surfaces or high voltage parts can cause personal
injury due to entrapment, burn or electric shocks.
• Do not perform any change of protective device itself or its setup condition.
The forced operation by short-circuiting protective device of pressure switch and
temperature controller or the use of non specified component can cause fire or burst.
SAFETY PRECAUTIONS
• Read the “SAFETY PRECAUTIONS” carefully first of all and strictly follow it during the installation work in order to
protect yourself.
• The precautionary items mentioned below are distinguished into two levels, and .
: Wrong installation would cause serious consequences such as injuries or death.
: Wrong installation might cause serious consequences depending on circumstances.
Both mentions the important items to protect your health and safety so strictly follow them by any means.
• Be sure to confirm no anomaly on the equipment by commissioning after completed installation and explain the operating methods aswell as the maintenance methods of this equipment to the user according to the owner’s manual.
• Keep the installation manual together with owner’s manual at a place where any user can read at any time.
Moreover if necessary, ask to hand them to a new user.
• For installing qualified personnel, take precautions in respect to themselves by using suitable protective clothing,
groves, etc., and then perform the installation works.
• Please pay attention not to fall down the tools, etc. when installing the unit at the high position.
• If unusual noise can be heard during operation, consult the dealer.
• The meanings of “Marks” used here are shown as follows:
CAUTIONWARNING
CAUTION
WARNING
Never do it under any
circumstances.
Always do it according to the
instruction.
INSTALLATION MANUAL
• When install the unit, be sure to check whether the selection of installation
place, power supply specifications, usage limitation (piping length, height
differences between indoor and outdoor units, power supply voltage and etc.)
and installation spaces.
Intake
The height of a wall is 1200mm or less.
(
service
space
)
L3
L2
L4
Example installation
Size