Mitsubishi SRK25ZSP-W, SRK35ZSP-W, SRK45ZSP-W Service Manual

Manual No.'18 • SRK-SM-259
SERVICE MANUAL
INVERTER WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONERS
(Split system, air to air heat pump type)
SRK25ZSP-W SRK35ZSP-W SRK45ZSP-W
'18 • SRK-SM-259

CONTENTS

1. OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER ................... 2
(1) Operation control function by wireless remote control
(2) Unit ON/OFF button
................................................................................. 3
............................. 2
................................................................................. 3(3) Auto restart function
(4) Installing two air-conditioners in the same room
...................................... 3
(5) High power operation ............................................................................... 4
(6) Economy operation
.................................................................................. 4
(7) Air flow direction adjustment .................................................................... 4
(8) Timer operation
........................................................................................ 5
(9) Outline of heating operation ..................................................................... 5
(10) Outline of cooling operation ..................................................................... 7
(11) Outline of automatic operation ................................................................. 7
(12) Protection control function
2. MAINTENANCE DATA
(1) Cautions
................................................................................................. 16
................................................................................. 16
....................................................................... 8
(2) Items to check before troubleshooting ................................................... 16
(3) Troubleshooting procedure
(If the air-conditioner does not run at all)
........ 16
(4) Troubleshooting procedure (If the air-conditioner runs)
......................... 17
(5) Self-diagnosis table ............................................................................... 18
(6) Service mode (Trouble mode access function) ..................................... 19
(7) Inspection procedures corresponding to detail of trouble ...................... 27
(8)
Phenomenon observed after short-circuit, wire breakage on sensor
(9) Checking the indoor electrical equipment
.............................................. 32
.......... 31
(10) How to make sure of wireless remote control ........................................ 33
(11) Outdoor unit inspection points ............................................................... 34
3. ELECTRICAL WIRING
(1) Indoor units
........................................................................................... 37
................................................................................. 37
(2) Outdoor units ........................................................................................ 38
4. PIPING SYSTEM
.......................................................................................... 40
-
-
'18 • SRK-SM-259

1. OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER

(1) Operation control function by wireless remote control

Remote control
Operation section
FAN SPEED button
Each time the button is pressed, the fan speed changes.
HI POWER/ECONO button
This button changes the HIGH POWER/ ECONOMY mode.
ON TIMER button
This button selects ON TIMER operation.
SLEEP button
This button selects SLEEP operation.
CLEAN switch
This switch selects the SELF CLEAN mode.
CANCEL button
This button cancels the ON timer, OFF timer, and SLEEP operation.
The above illustration shows all controls, but in
practice only the relevant parts are shown.
OPERATION MODE select button
Each time the button is pressed, the mode changes.
ON/OFF (luminous) button
Press to start operation, press again to stop.
AIR FLOW (UP/DOWN) button
This button changes the air flow (up/down) direction.
TEMPERATURE button
These buttons set the room temperature. (These buttons are used for setting the current time and timer function as well.)
OFF TIMER button
This button selects OFF TIMER operation.
ACL switch
This switch resets the program to default state.
Unit display section
Unit ON/OFF button
This button can be used for turning on/off the unit when a remote control is not available.
Wireless remote control signal receiver
RUN light (green)
Illuminates during operation.
Blinks slowly when SELF CLEAN operation (3 seconds ON, 1 second OFF).
Blinks when air flow is stopped to
prevent blowing out of cold air in heating operation. (1.5 seconds ON,
0.5 seconds OFF)
TIMER light (yellow)
Ⅰlluminates during TIMER operation.
-
-
'18 • SRK-SM-259
Cut

(2) Unit ON/OFF button

When the wireless remote control batteries become weak, or if the wireless remote control is lost or malfunctioning, this
button may be used to turn the unit on and off.
(a) Operation
Push the button once to place the unit in the automatic mode. Push it once more to turn the unit off.
(b) Details of operation
The unit will go into the automatic mode in which it automatically determines, from room temperature (as detected by
sensor), whether to go into the COOL, DRY or Heat modes.
Operation mode
COOL
DRY
HEAT
Function
Room temperature
setting
About 24ºC
About 24ºC
About 26ºC
Fan
speed
Flap
Auto Auto
Timer
switch
Continuous
Unit ON/OFF button

(3) Auto restart function

(a)
Auto restart function records the operational status of the air-conditioner immediately prior to be switched off by a
power cut, and then automatically resumes operations after the power has been restored.
(b) The following settings will be cancelled:
(i) Timer settings
(ii) HIGH POWER operation
Jumper wire (J1)
Notes (1) Auto restart function is set at on when the air-conditioner is shipped from the factory. Consult
with your dealer if this function needs to be switched off.
(2) When power failure ocurrs, the timer setting is cancelled. Once power is resumed, reset the timer.
If the jumper wire (J1) “AUTO RESTART” is cut, auto restart is disabled. (See the diagram at right.)
(3)

(4) Installing two air-conditioners in the same room

When two air-conditioners are installed in the room, set the wireless
remote contrrol and indoor unit as belows to prevent operating air-condi-
tioners with one wireless remote control.
(a) Setting an indoor unit’s printed circuit board
Jumper wire (J2)
(i) Take out the printed circuit board from the control box.
(ii) Disconnect jumper wire (J2) with wire cutters.
(iii) Install a printed circuit board.
(b) Setting a wireless remote control
(i) Pull out the cover and take out batteries.
(ii) Disconnect the switching line next to the battery with wire cutters.
(iii) Insert batteries. Close the cover.
-
-
'18 • SRK-SM-259

(5) High power operation

(6) Economy operation

Pressing the HI POWER/ECONO button intensifies the operating power and initiates powerful cooling and heating operation for
15 minutes continuously. The wireless remote control displays HIGH POWER mark and the FAN SPEED display disappears.
(a) During the HIGH POWER operation, the room temperature is not controlled. When it causes an excessive cooling and hea-
ting, press the HI POWER/ECONO button again to cancel the HIGH POWER operation.
(b) HIGH POWER operation is not available during the DRY and the ON timer to OFF timer operations.
(c) When HIGH POWER operation is set after ON TIMER operation, HIGH POWER operation will start from the set time.
(d) When the following operation are set, HIGH POWER operation will be canceled. When the HI POWER/ECONO button is pressed again. When the operation mode is changed. When it has been 15 minutes since HIGH POWER operation has started.
(e) Not operable while the air-conditioner is OFF.
Pressing the HI POWER/ECONO button initiates a soft operation with the power suppressed in order to avoid an excessive cooling or heating. The unit operates 1.5 higher than the setting temperature during cooling or 2.5 lower than that during
heating. The wireless remote control displays ECONO mark and the FAN SPEED display disappears.
(a) It will go into ECONOMY operation at the next time the air-conditioner runs in the following cases. When the air-conditioner is stopped by ON/OFF button during ECONOMY operation. When the air-conditioner is stopped in SLEEP or OFF TIMER operation during ECONOMY operation. When the operation is retrieved from CLEAN operation.
(b) When the following operation are set, ECONOMY operation will be canceled. When the HI POWER/ECONO button is pressed again. When the operation mode is changed DRY to FAN.
(c) Not operable while the air-conditioner is OFF.
(d) The setting temperature is adjusted according to the following table.
at the start of operation. one hour after the start of operation. two hours after the start of operation.

(7) Air flow direction adjustment

Air ow direction can be adjusted with by AIR FLOW
(a) Flap
Item
Temperature adjustment
Each time when you press the AIR FLOW
Angle of flap from horizontal
Remote control display
COOL, DRY, FAN
HEAT
Mode
(Flap stopped)
Cooling Heating
①+0.5 ②+1.0 ②-2.0 ③+1.5 ③-2.5
Approx. 15°
Approx. 25°
①-1.0
Approx. 25°
Approx. 35°
(UP/DOWN) button on the wireless remote control.
(UP/DOWN) button the mode changes as follows.
Approx. 35°
Approx. 50°
Approx. 45°
Approx. 59°
Approx. 59°
Approx. 65°
(Swing)
-
-
'18 • SRK-SM-259
In HEAT operation In COOL, DRY, FAN operation
Approx. 65°
ON OFF OFF
ON ON OFF
ON
OFF
(few minutes ON)
OFF
ON ON(HOT KEEP) OFF
OFF
OFF
(3 minutes ON)
OFF
OFF
Thermostat ON Thermostat OFF Defrost Failure
Heating
Compressor
Indoor fan motor
Outdoor fan motor
4-way valve
20-115rps 20-100rps
20
-
115rps 20-100rps
20
-
72rps 20-84rps 20-90rps
20
-
54rps 20-62rps 20-58rps
Model
Fan speed
SRK25ZSP-W SRK35ZSP-W SRK45ZSP-W
AUTO
MED
HI
LO
(b) Swing
Flap moves in upward and downward directions continuously.
Approx.
20°
Approx. 35°
Approx. 59°
(c) Memory flap
When you press the AIR FLOW (UP/DOWN) button once while the ap is operating, it stops swinging at the position.
Since this angle is memorized in the microcomputer, the ap will automatically be set at this angle when the next opera-
tion is started.
(d) When not operating
The ap returns to the position of air ow directly below, when operation has stopped.

(8) Timer operation

(a) Comfortable timer setting (ON timer)
If the timer is set at ON when the operation select switch is set at the cooling or heating, or the cooling or heating in
auto mode operation is selected, the comfortable timer starts and determines the starting time of next operation based
on the initial value of 15 minutes and the relationship between the room temperature at the setting time (temperature of
room temperature sensor) and the setting temperature.
(b) Sleep timer operation
Pressing the SLEEP button causes the temperature to be controlled with respect to the set temperature.
(c) OFF timer operation
The Off timer can be set at a specic time (in 10-minute units) within a 24-hour period.

(9) Outline of heating operation

(a) Operation of major functional components in heating mode
(b) Details of control at each operation mode (pattern)
(i) Fuzzy operation
Deviation between the room temperature setting correction temperature and the suction air temperature is calculated in accordance with the fuzzy rule, and used for control of the air capacity and the compressor speed.
When the defrost operation, protection device, etc. is actuated, operation is performed in the corresponding mode.
-
-
(ii) Hot keep operation
Outdoor heat exchanger temperature (
TH1
-20
-25
-20 -15 -10 -5 0 5 10
-15
-10
-5
0
Outdoor air temperature ()
TH2
Outdoor heat exchanger temperature ()
Defrost operation start
Defrost operation start temperature
Model DXK15Z6-S
1) Fuzzy operation
2) Hot keep operation
ON OFF
ON ON
ON
OFF
(few minutes ON)
ON ON(HOT KEEP)
OFF
OFF
(3 minutes ON)
OFF
OFF
Thermostat ON Thermostat OFF Failure
Heating
Compressor
Indoor fan motor
Outdoor fan motor
4-way valve
(i)
1)
2)
3)
4)
≦
30~115rps
30~115rps
30~76rps
30~46rps
SRK35ZJ-S
23~106rps
23~106rps
23~78rps
23~50rps
SRK50ZJ-S
30~115rps
30~115rps
30~72rps
30~42rps
SRK25ZJ-S
30~115rps
30~115rps
30~66rps
30~40rps
SRK20ZJ-S
Model
Fan speed
Auto
MED
HI
LO
(model DXK12 : 45)
35
35
(model DXK12 : 45)
(model DXK15 : 2 ) (model DXK15 : 10 )
(model DXK15 :
2
)
5)
1) 2) 3) 5)
(model DXK15 : 10 )
higher
met.
(model SRK50 : 35)
(model SRK50 : 35)
'09•SRK-DB-087D
(16)Outline of heating operation
(a) Operation of major functional components in heating mode
(b) Details of control at each operation mode (pattern)
(i) Fuzzy operation
(ii) Hot keep operation
ON OFF
ON ON
ON
OFF
(few minutes ON)
ON ON(HOT KEEP)*
OFF
OFF
(3 minutes ON)
OFF
OFF
Thermostat ON Thermostat OFF Failure
Heating
Compressor
Indoor fan motor
Outdoor fan motor
4-way valve
(c) Defrost operation
(i)
1)
2)
3)
4)
5)
Model
Fan speed
Auto
MED
HI
LO
ULO
*It can be set the indoor fan motor off or the heating thermostat OFF with connecting a wired remote control.
In the case, indoor air temperature is detected by sensor on the wired remote control.
During the heating operation, the indoor fan speed can be controlled based on the temperature of the indoor heat exchanger (Th2) to prevent blowing out of cold air.
are satisfied.)
(Total compressor operation time)
After finish of defrost operation
C or less for 3 minutes continuously.
(Total compressor operation time)
20~115rps
20~115rps
20~86rps
20~70rps
20~44rps
SRK20ZS-S
20~115rps
20~115rps
20~104rps
20~84rps
20~54rps
SRK25ZS-S
20~115rps
20~115rps
20~108rps
20~96rps
20~60rps
SRK35ZS-S
23~106rps
23~106rps
23~82rps
23~70rps
23~37rps
SRK50ZS-S
is as following.
During the heating operation, the indoor fan speed can be controlled based on the temperature of the indoor heat ex-
changer (Th2) to prevent blowing of cold air.
(c) Defrost operation
(i)
1)
(model SRK35 : 45)
35
2)
35
(model SRK35 : 45)
3)
4)
follows.
TH2
0
TH2
TH2: TH2
℃≦
℃≦
15
0
TH2
: TH2
15
TH1
: TH2
TH1
7
Models SRK25, 35, 45ZSP-W
(ii)
1)
2)
0
)
-5
-10
TH1
-15
-20
-25
In case satisfied all of following conditions.
-20 -15 -10 -5 0 5 10
• Connect compressor speed 0 rps 10 times or more.
• Satisfy 1), 2) and 3) conditions above.
• Outdoor air temperature is 3°C or less.
Defrost operation start temperature
Outdoor air temperature ()
and 30 seconds).
Defrost operation
Heating operation
Depends on an operation condition, the time can be longer than 7 minutes.
, TH1
2/15
TH1
, TH1
5
Defrost operation start
TH2
operation
(Mode SRK45: Max.17 minutes and 30 seconds)
Total
Total
or less
7
13/15
, TH1
7
TH2
×
5
TH2
Max. 16 minutes and 50 seconds
-
-
'18 • SRK-SM-259
satisfied.
7
TH2
×
satisfied.
(SRK45 : 10 )
16
minutes and 50 seconds (model SRK45 : 17 minutes
2-7 minutes
Hot keep operation
is as
27.5
25.5
18.0
18
30

(10) Outline of cooling operation

ON OFF OFF
OFF OFF OFF
ON
OFF
(few minutes ON)
OFF
(few minutes ON)
ON ON ON
Thermostat ON Thermostat OFF Failure
Cooling
Compressor
Indoor fan motor
Outdoor fan motor
4-way valve
15-74rps 20-97rps
15-74rps
15-98rps
15-98rps 20-97rps
15-52rps 15-74rps 20-72rps
15-38rps 15-46rps 20-44rps
Model
Fan speed
SRK25ZSP-W SRK35ZSP-W SRK45ZSP-W
AUTO
MED
HI
LO
(a) Operation of major functional components in cooling mode
(b) Detail of control in each mode (Pattern)
(i) Fuzzy operation
During the fuzzy operation, the air ow and the compressor speed are controlled by calculating the difference between
the room temperature setting correction temperature and the suction air temperature.
'18 • SRK-SM-259

(11) Outline of automatic operation

(a) Determination of operation mode
The unit checks the indoor air temperature and the outdoor air temperature, determines the operation mode, and then
begins in the automatic operation.
Cooling
Indoor air temperature (˚C)
A
Heating
Outdoor air temperature (˚C)
Dehumidifying
(b) The unit checks the temperature every hour after the start of operation and, if the result of check is not same as the pre-
vious operation mode, changes the operation mode.
(i) If the setting temperature is changed with the remote control, the operation mode is judged immediately.
(ii) When both the indoor and the outdoor air temperatures are in the range “A”, cooling or heating is switched depending
on the difference between the setting temperature and the indoor air temperature.
(iii) When the operation mode has been judged following the change of setting temperature with the remote control, the hour-
ly judgment of operation mode is cancelled.
(c) When the unit is started again within one hour after the stop of automatic operation or when the automatic operation is
selected during heating, cooling or dehumidifying operation, the unit is operated in the previous operation mode.
(d) Setting temperature can be adjusted within the following range. There is the relationship as shown below between the
signals of the wireless remote control and the setting temperature.
Signals of wireless remote control (Display)
Setting temperature
Cooling
Dehumidifying
Heating
–6 –5 –4 –3 –2 –1
18 19 20 21 22 23 24 25 26 27 28 29 30
19 20 21 22 23 24 25 26 27 28 29 30 31
20 21 22 23 24 25 26 27 28 29 30 31 32
0 +1 +2 +3 +4 +5 +6
±
(e) When the unit is operated automatically with the wired remote control connected, the cooling operation is controlled ac-
cording to the display temperatures while the setting temperature is compensated by +1˚C during dehumidifying or by
2˚C during heating.
-
-

(12) Protection control function

(a) Dew prevention control Ⅰ [Cooling]
Prevents dewing on the indoor unit.
(i) Operating conditions
When the following conditions have been satised.
1) Humidity is 78% or higher.
(ii) Contents of operation
Maximum compressor speed SRK25ZSP-W
SRK35ZSP-W
SRK45ZSP-W
68 rps
73 rps
87 rps
(iii) Reset condition
When either of the following condition is satised.
1) Humidity is 73% or less.
2) Dew prevention control Ⅱ has been satised.
(b) Dew prevention control Ⅱ [Cooling]
Prevents dewing on the indoor unit.
(i) Operating conditions
When the following conditions have been satised for more than 30 minutes after starting operation
1) Compressor speed is 32 rps or higher. (SRK25, 35)
2) Humidity is 68% or higher. (SRK45 : 60%)
(ii) Contents of operation
1) Air capacity control
'18 • SRK-SM-259
Model
Item
Upper limit of compressor speed
LO
SRK25,35ZSP-W SRK45ZSP-W
RangeA: 41rps, RangeB: 41rps RangeA: 57rps, RangeB: 39rps
Indoor fan 4th speed (SRK35 : 5th speed)
AUTO,HI,MED
Upper limit of compressor speed
Indoor fan
RangeA: 41rps, RangeB: 41rps RangeA: 57rps, RangeB: 39rps
Adaptable to compressor
speed (Lower limit 4th speed)
Note (1) Ranges A and B are as shown below.
Range B
Range A
68
73
Humidity(%)
2) When this control has continued for more than 30 minutes continuously,the following wind direction control is per-
formed.
a) When the vertical wind direction is set at other than the vertical swing,the aps change to the horizontal position.
b) When the horizontal wind direction is set at other than the horizontal swing,the louver changes to the vertical po-
sition.
(iii) Reset condition
When any of followings is satised.
1) Humidity is less than 63%. (SRK45 : 55%)
-
-
'09•SRK-DB-087D
(c) Frost prevention control
A
B
C
Outdoor heat exchanger temperature(°C)
8rps
(1)
8rps
(1)
0rps
After lapse of 20 sec. or over
(3)
After lapse of 20 sec. or over
(3)
After lapse of 20 sec. or over
(3)
(Example) Fuzzy
(i) Operating conditions
1)
2)
(ii) Detail of anti-frost operation
Indoor heat exchanger
Item
Lower limit of compressor speed
Indoor fan
Outdoor fan
4-way valve
temperature
(iii) Reset conditions
1)
2)
5°C or lower 2.5°C or lower
22rps (SRK45 : 23 rps)
compressor
-
-
'18 • SRK-SM-259
compressor
speed
Lower
limit
speed
0 rps
2.55 8
Indoor heat exchanger
temperature (ºC)
(d) Cooling overload protective control
(i) Operating conditions
When the outdoor air temperature (TH2) has become continuously for 30 seconds at 41ºC or more, or 47ºC or more
with the compressor running, the lower limit speed of compressor is brought up.
Model
Item
Outdoor air temperature
Lower limit speed
SRK25, 35ZSP-W SRK45ZSP-W
41°C or more 47°C or more 41°C or more 47°C or more
30 rps 45 rps 27 rps 35 rps
(ii) Detail of operation
1) The outdoor fan is stepped up by 3 speed step. (Upper limit; 8th speed.)
2) The lower limit of compressor speed is set to 30 or 45(model SRK45 : 27 or 35) rps. However, when the thermo
OFF, the speed is reduced to 0 rps.
(iii) Reset conditions
When either of the following condition is satised.
1) The outdoor air temperature is lower than 40ºC.
2) The compressor speed is 0 rps.
(e) Cooling high pressure control
(i) Purpose
Prevents anomalous high pressure operation during cooling.
(ii) Detector
Outdoor heat exchanger sensor (TH1)
(iii) Detail of operation
-
-
Notes (1) When the outdoor heat exchanger temperature is in the range of B-C ºC, the speed is reduced by 8 rps at each 20 seconds.
'09•SRK-DB-087D
(i) Operating conditions
(e) Cooling low outdoor air temperature protective control
(i) Operating conditions
(ii) Detail of operation
When the outdoor air temperature (TH2) is 22°C or lower continues for 20 seconds while the compressor speed is other than 0 rps.
Compressor speed: Upper/lower limit (rps)
Lower 3Upper 2Lower 2
Lower 1
Range BRange A
Upper 1Upper 3
50504430
50
445044
60
6027
Release
Release
50
SRK25, 35
SRK45
1) It controls the upper and lower limit values for the compressor speed according to the following table.
2) It checks the outdoor temperature (TH2) once every hour to judge the operation range.
'09•SRK-DB-087D
(2) When the temperature is C ºC or higher, the compressor is stopped. (3) When the outdoor heat exchanger temperature is in the range of A-B ºC, if the compressor speed is been maintained and the operation has
Temperature list
Outdoor air temperature Outdoor air temperature <
continued for more than 20 seconds at the same speed, it returns to the normal cooling operation.
SRK25, 35 SRK45
> =
32 ºC 32 ºC
A B C A B C
53 58 63 48 53 55
40 43 46 53 58 63
(f) Cooling low outdoor air temperature protective control
'18 • SRK-SM-259
Upper limit 50 rps
ON
Lower limit 50ࠝ44ࠞ rps
EF
First time
After the second times
Upper limit 50 rps
ON
Lower limit 44 rps
Outdoor air temperature (°C)
(iii) Reset conditions
1)
2)
(g)
Heating high pressure control
(i) Purpose
(ii) Detector
Upper limit 60 rps
ON
Lower limit 3027ࠞ rps
CDAB
(Models SRK25, 35)
Outdoor air temperature (˚C)
ABCDEF
OFF
First time
After the second times
Range A
Range B
Indoor air temperature ( Υ
2624
)
, E, F (Model SRK45)
Outdoor air temperature (˚C)
E FABCD
0
5721691911252228
25
(iii) Detail of operation
(Example) Fuzzy
After lapse of 10 sec. or over
After lapse of 10 sec. or over
After lapse of 10 sec. or over
A
Indoor heat exchanger temperature(°C)
(3)
(3)
lower limit
(3)
speed 30(35) rps
B
4rps
(1)
(1)
4rps
C
8rps
(2)
8rps
(2)
0rps
D
-
-
10
'09•SRK-DB-087D
CDAB
OFF
EF
Upper limit 50 rps Lower limit 44 rps
ON
ON
Upper limit 50 rps Lower limit 5044 rps
ON
Upper limit 60 rps Lower limit 3027 rps
Outdoor air temperature (°C)
Heating high pressure control
A
B
C
D
Indoor heat exchanger temperature(°C)
4rps
(1)
8rps
(2)
8rps
(2)
4rps
(1)
0rps
-
-
After lapse of 10 sec. or over
(3)
After lapse of 10 sec. or over
(3)
After lapse of 10 sec. or over
(3)
lower limit
speed 30(35) rps
First time
After the second times
Outdoor air temperature (˚C)
ABCDEF
1)
2)
(Models SRK25, 35)
First time
After the second times
Outdoor air temperature (˚C)
E FABCD
, E, F (Model SRK45)
0
5721691911252228
25
2624
Indoor air temperature ( Υ
)
Range A
Range B
'09•SRK-DB-087D
(h) Heating overload protective control
10
fan fan
Temperature list
Models SRK25, 35 Unit : ºC
RPSmin < 50
<
50
RPSmin < 92
=
92
<
RPSmin
=
< =
115
speed
A B C D
47 52 54 55
47.5 55 57 61
47.5-39.0 55.0-40.0 57.0-42.0 61
-
'18 • SRK-SM-259
Model SRK45 Unit : ºC Unit : ºC
RPSmin < 30
<
30
RPSmin < 40
= <
40
RPSmin < 80
= <
80
RPSmin < 90
= <
90
RPSmin < 100
=
(i) Indoor unit side
1) Operating conditions
2) Detail of operation
3) Reset conditions
(ii) Outdoor unit side
1) Operating conditions
When the outdoor air temperature (TH2) is 22 (11 or 20)ºC or higher continues for 30 seconds while the compressor
speed other than 0 rps.
2) Detail of operation
Upper and lower limits of compressor speed and the outdoor unit fan speed are restricted.
Models SRK25,35
ON1 ON2
Model SRK45
ON1 ON2
A B C
45 49 50
45-49 49-55 50-57
49 55 57
49-48 55-53 57-55
48-37 53-42 55-44
Upper limit
Upper limit
Compressor command speed (rps)
Lower limit
Range A Range B
40 Release 60 2nd speed
Compressor command speed (rps)
Lower limit
Range A Range B
35 Release 85 It depends on compressor speed
35 35 55 2nd speed
Outdoor fan speed
Outdoor fan speed
RPSmin < 35
<
35
RPSmin < 40
= <
40
RPSmin < 80
= <
80
RPSmin < 95
= <
95
RPSmin < 100
=
D
55.5
55.5-62
62
62-56
56-50.5
Protective control
Normal operation
OFF
ON1
10
Outdoor air temperature(°C)
3) Reset conditions
When the outdoor air temperature drops below 19 (13)ºC.
Note (1) Values in ( ) are for the model SRK45.
22 (20)21 (19)11
ON2
Range A
Range B
Indoor air temperature ( Υ
2321
)
-
-
11
Loading...