Mitsubishi Electric ANS-Q-LARGE-U, Q35BLS, Q38BLS, Q38BLS-D, Q65BLS User Manual

...
Q Series Large Type
Base Unit/Blank Cover
(AnS Series Size)
User's Manual
Q35BLS Q35BLS-D QG69LS Q38BLS Q38BLS-D Q65BLS Q65BLS-D Q68BLS Q68BLS-D Q55BLS Q55BLS-D
Thank you for purchasing the Mitsubishi Electric programmable controller MELSEC-Q series.
Prior to use, please read this and relevant manuals thoroughly to fully understand the product.
MODEL ANS-Q-LARGE-U MODEL
CODE
IB(NA)-0800495-E(1806)MEE
13J290
© 2013MITSUBISHI ELECTRIC CORPORATION

CONDITIONS OF USE FOR THE PRODUCT

(1) Mitsubishi programmable controller ("the PRODUCT") shall be used in
conditions; i) where any problem, fault or failure occurring in the PRODUCT, if any, shall not lead to any major or serious accident; and ii) where the backup and fail-safe function are systematically or automatically provided outside of the PRODUCT for the case of any problem, fault or failure occurring in the PRODUCT.
(2) The PRODUCT has been designed and manufactured for the purpose of
being used in general industries. MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY (INCLUDING, BUT NOT LIMITED TO ANY AND ALL RESPONSIBILITY OR LIABILITY BASED ON CONTRACT, WARRANTY, TORT, PRODUCT LIABILITY) FOR ANY INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE OPERATED OR USED IN APPLICATION NOT INTENDED OR EXCLUDED BY INSTRUCTIONS, PRECAUTIONS, OR WARNING CONTAINED IN MITSUBISHI'S USER, INSTRUCTION AND/OR SAFETY MANUALS, TECHNICAL BULLETINS AND GUIDELINES FOR the PRODUCT. ("Prohibited Application") Prohibited Applications include, but not limited to, the use of the PRODUCT in;
• Nuclear Power Plants and any other power plants operated by Power companies, and/or any other cases in which the public could be affected if any problem or fault occurs in the PRODUCT.
• Railway companies or Public service purposes, and/or any other cases in which establishment of a special quality assurance system is required by the Purchaser or End User.
• Aircraft or Aerospace, Medical applications, Train equipment, transport equipment such as Elevator and Escalator, Incineration and Fuel devices, Vehicles, Manned transportation, Equipment for Recreation and Amusement, and Safety devices, handling of Nuclear or Hazardous Materials or Chemicals, Mining and Drilling, and/or other applications where there is a significant risk of injury to the public or property.
A-1
Notwithstanding the above, restrictions Mitsubishi may in its sole discretion, authorize use of the PRODUCT in one or more of the Prohibited Applications, provided that the usage of the PRODUCT is limited only for the specific applications agreed to by Mitsubishi and provided further that no special quality assurance or fail-safe, redundant or other safety features which exceed the general specifications of the PRODUCTs are required. For details, please contact the Mitsubishi representative in your region.
A-2

REVISIONS

*The manual number is given on the bottom right of the cover.
Print date *Manual number Revision
January 2013 IB(NA)-0800495-A First edition
February 2013 IB(NA)-0800495-B Change of the external dimension diagram
November 2015 IB(NA)-0800495-C Descriptions regarding the Q series large type
December 2016 IB(NA)-0800495-D Descriptions are revised due to compliance with
June 2018 IB(NA)-0800495-E Descriptions are revised due to compliance with
base unit are added.
the new China RoHS.
the Chinese standardized law.
This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
© 2013 MITSUBISHI ELECTRIC CORPORATION
A-3

CONTENTS

1. OVERVIEW .................................................................................................... 1
1.1 Overview ............................................................................................... 1
1.2 Features ................................................................................................ 1
1.3 Supplied Parts....................................................................................... 3
2. SYSTEM CONFIGURATION.......................................................................... 5
2.1 System Configuration ............................................................................ 5
2.2 Precautions for System Configuration................................................. 10
2.3 Modules That Cannot be Mounted on the Q Series Large Type
Base Unit (AnS Series Size) ............................................................... 11
3. SPECIFICATIONS........................................................................................ 12
3.1 Specifications of the Q Series Large Type Base Unit
(AnS Series Size) ................................................................................ 12
3.2 Specifications of the Q Series Large Type Blank Cover
(AnS Series Size) ................................................................................ 14
4. PARTS NAMES ............................................................................................ 15
4.1 Parts Names ....................................................................................... 15
5. MOUNTING AND INSTALLATION ............................................................... 18
5.1 Handling Precautions .......................................................................... 18
5.2 Precautions for Installing the Q Series Large Type Base Unit
(AnS Series Size) ................................................................................ 19
5.3 Mounting and Installation of the Q Series Large Type Base Unit
(AnS Series Size) ................................................................................ 21
5.4 Mounting/Removing the Q Series Module .......................................... 23
6. EXTERNAL DIMENSIONS ........................................................................... 25
6.1 Q Series Large Type Base Unit (AnS Series Size) ............................. 25
6.2 Q Series Large Type Blank Cover (AnS Series Size) ......................... 29
A-4

TERMS

Unless otherwise specified, this manual uses the following generic terms and abbreviations to explain the Q series large type base units (AnS series size) and Q series large type blank cover (AnS series size).
Term Description
Q series large type base unit (AnS series size)
Q series large type main base unit (AnS series size)
Q series large type extension base unit (AnS series size)
Q series large type blank cover (AnS series size)
Q series
AnS series
High Performance model QCPU
Universal model QCPU
MELSECNET/H remote I/O module
Q3B
Q3DB
Q5B A generic term for the Q52B and Q55B extension base units
Q6B
QA1S5B Another term for the QA1S51B extension base unit
QA1S6B
QA6B
A generic term for the Q series large type main base unit (AnS series size) and Q series large type extension base units (AnS series size)
A generic term for the Q35BLS, Q38BLS, Q35BLS-D, and Q38BLS-D MELSEC-Q series main base units
A generic term for the Q65BLS, Q68BLS, Q55BLS, Q65BLS-D, Q68BLS-D, and Q55BLS-D MELSEC-Q series extension base units
The abbreviation for the QG69LS MELSEC-Q series blank cover
The abbreviation for Mitsubishi MELSEC-Q series programmable controller
The abbreviation for compact types of Mitsubishi MELSEC­A series programmable controller
A generic term for the Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, and Q25HCPU
A generic term for the Q00UJCPU, Q00UCPU, Q01UCPU, Q02UCPU, Q03UDCPU, Q03UDVCPU, Q03UDECPU, Q04UDHCPU, Q04UDVCPU, Q04UDEHCPU, Q06UDHCPU, Q06UDVCPU, Q06UDEHCPU, Q10UDHCPU, Q10UDEHCPU, Q13UDHCPU, Q13UDVCPU, Q13UDEHCPU, Q20UDHCPU, Q20UDEHCPU, Q26UDHCPU, Q26UDVCPU, Q26UDEHCPU, Q50UDEHCPU, and Q100UDEHCPU
A general term for the QJ72LP25-25, QJ72LP25G, and QJ72BR15
A generic term for the Q33B, Q35B, Q38B, and Q312B main base units
A generic term for the Q35DB, Q38DB, and Q312DB multiple CPU high speed main base units
A generic term for the Q63B, Q65B, Q68B, and Q612B extension base units
A generic term for the QA1S65B and QA1S68B extension base units
A generic term for the QA65B and QA68B extension base units
A-5
A5
B
B
A6
QA6ADP
QA6ADP+A5
Term Description
A generic term for the A52B, A55B, and A58B extension base units
A generic term for the A62B, A65B, and A68B extension base units
The abbreviation for the QA6ADP QA conversion adapter module
B/A6B
The abbreviation for the A large type extension base unit on which QA6ADP is mounted
A-6

1. OVERVIEW

1.1 Overview

The products are used to replace the AnS series with the Q series when the existing installation site and cables are utilized.
This manual explains specifications, component devices, part names, settings, mounting, and installation of the Q series large type base unit (AnS series size) and Q series large type blank cover (AnS series size). For contents not explained in this manual such as SAFETY PRECAUTIONS, EMC and Low Voltage Directives, and general specifications, refer to the following manual:
QCPU User's Manual (Hardware Design, Maintenance and Inspection)

1.2 Features

This section explains features of the Q series large type base unit (AnS series size) and Q series large type blank cover (AnS series size).
(1) The Q series large type base unit (AnS series size) is available in
two types; DIN rail mounting type and panel mounting type. Select the suitable type of a base unit for the operating environment.
Mounting type Main base unit Extension base unit
Panel mounting type
DIN rail mounting type
Q35BLS Q38BLS
Q35BLS-D Q38BLS-D
Q65BLS Q68BLS Q55BLS
Q65BLS-D Q68BLS-D Q55BLS-D
1
(2) Since the Q series large type base unit (AnS series size) has the
24
V
D
C
4
m
A
QX40
+
-
2
4
V
D
C
4
m
A
QX40
+
-
2
4
V
D
C
4
m
A
QX40
+
-
2
4V
D
C
4
m
A
QX40
+
-
Q12HCPU
MODE
RU
N
ERR. USER
B
AT.
BOOT
PULL
USB
RS-232
MELSEC
Q62P
PO
W
E
R
PULL
2
4
V
D
C
4
m
A
Q
X
4
0
+
-
Q series module
Q series large type base unit (AnS series size)
Q series large type blank cover (AnS series size)
*1
(3) Mount the Q series module on the Q series large type base unit
same mounting dimensions with the AnS series base unit, the same mounting holes can be utilized. The following table shows the corresponding models for replacement.
AnS series base unit
A1S35B Q35BLS
A1S38B Q38BLS
A1S65B Q65BLS
A1S68B Q68BLS
A1S55B Q55BLS
Q series large type base unit
(AnS series size)
(AnS series size).
The renewal tool manufactured by MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED (hereafter, abbreviated as renewal tool) can be mounted on the module, and a connector and terminal block used with the AnS series can be used without wiring change.
*1 To mount the Q series module on the I/O slot of the Q series large type base unit (AnS
series size), always attach the Q series large type blank cover (AnS series size).
2

1.3 Supplied Parts

(1) Q series large type main base unit (AnS series size)
(panel mounting type)
Product Model Quantity Remarks
Q35BLS
Q series large type main base unit (AnS series size)
Base unit mounting screw - 4 M5 × 25 screw
This manual IB-0800495 1 -
Safety Guidelines
*1 The Q series large type extension base unit (AnS series size) does not include with the
guidelines.
*1
(2) Q series large type main base unit (AnS series size)
(DIN rail mounting type)
Product Model Quantity Remarks
Q series large type main base unit (AnS series size)
DIN rail mounting adapter
End fitting L - 1 -
End fitting R - 1 -
Fixing bracket for terminal block conversion adapter
Bracket fixing screw - 6 M4×8 screw
*1*2
Q38BLS
Q65BLS
Q68BLS
Q55BLS
IB-0800423 1 -
Q35BLS-D
Q38BLS-D
Q65BLS-D
Q68BLS-D
Q55BLS-D
Q6DIN1 or Q6DIN2 1
-1 -
3
1 -
1-
Q6DIN1 (Includes 2 adapters (large), 4 adapters (small),
3 square washers,
and 3 mounting screws
Q6DIN2 (Includes 2 adapters (large), 3 adapters (small),
2 square washers,
and 2 mounting screws
(M5×10))
(M5×10))
Product Model Quantity Remarks
This manual IB-0800495 1 -
Safety Guidelines
*1 For a combination of the DIN rail mounting adapter, refer to the following:
Q6DIN1: Q38BLS-D and Q68BLS-D Q6DIN2: Q35BLS-D, Q65BLS-D, and Q55BLS-D
*2 The stopper for DIN rail mounting adapter is not included with this base unit since the end
fitting is substitutable.
*3 The Q series large type extension base unit (AnS series size) does not include with the
guidelines.
*3
IB-0800423 1 -
(3) Q series large type blank cover (AnS series size)
Product Model Quantity Remarks
Q series large type blank cover (AnS series size)
QG69LS 1 -
4

2. SYSTEM CONFIGURATION

CPU01234567
Power supply module
CPU module
Q series large type main base unit (AnS series size) (Q3BLS, Q3BLS-D), Q series main base unit (Q3B, Q3DB), or Q series large type main base unit (Q3BL)
Q series extension base unit (Q5B, Q6B), Q series large type extension base unit (AnS series size) (Q6BLS, Q6BLS-D, Q55BLS, Q55BLS-D), or Q series large type extension base unit (Q6BL, Q55BL)
Q series extension base unit on which AnS series module can be mounted (QA1S5B, QA1S6B)
Q series extension base unit on which A series module can be mounted (QA6B)
QA conversion adapter + A/QnA series extension base unit (QA6ADP + A5B/A6B)
Main base unit
Extension base unit
Slot number
8 9 10 11 12 13 14 15
16 17 18 19 20 21 22 23
24 25 26 27 28 29 30 31
32 33 34 35 36 37 38 39

2.1 System Configuration

This section explains system configuration when using the Q series large type base unit (AnS series size). The following modules can be mounted on the CPU slot of the Q series large type base unit (AnS series size).
• High Performance model QCPU
• Universal model QCPU (except Q00UJCPU)
• MELSECNET/H remote I/O module
(1) System configuration using the High Performance model QCPU
and Universal model QCPU
5
Loading...
+ 26 hidden pages