(1) Mitsubishi programmable controller ("the PRODUCT") shall be used in
conditions;
i) where any problem, fault or failure occurring in the PRODUCT, if any,
shall not lead to any major or serious accident; and
ii) where the backup and fail-safe function are systematically or
automatically provided outside of the PRODUCT for the case of any
problem, fault or failure occurring in the PRODUCT.
(2) The PRODUCT has been designed and manufactured for the purpose of
being used in general industries.
MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY
(INCLUDING, BUT NOT LIMITED TO ANY AND ALL RESPONSIBILITY
OR LIABILITY BASED ON CONTRACT, WARRANTY, TORT, PRODUCT
LIABILITY) FOR ANY INJURY OR DEATH TO PERSONS OR LOSS OR
DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE
OPERATED OR USED IN APPLICATION NOT INTENDED OR
EXCLUDED BY INSTRUCTIONS, PRECAUTIONS, OR WARNING
CONTAINED IN MITSUBISHI'S USER, INSTRUCTION AND/OR SAFETY
MANUALS, TECHNICAL BULLETINS AND GUIDELINES FOR the
PRODUCT.
("Prohibited Application")
Prohibited Applications include, but not limited to, the use of the PRODUCT
in;
• Nuclear Power Plants and any other power plants operated by Power
companies, and/or any other cases in which the public could be
affected if any problem or fault occurs in the PRODUCT.
• Railway companies or Public service purposes, and/or any other cases
in which establishment of a special quality assurance system is
required by the Purchaser or End User.
• Aircraft or Aerospace, Medical applications, Train equipment, transport
equipment such as Elevator and Escalator, Incineration and Fuel
devices, Vehicles, Manned transportation, Equipment for Recreation
and Amusement, and Safety devices, handling of Nuclear or
Hazardous Materials or Chemicals, Mining and Drilling, and/or other
applications where there is a significant risk of injury to the public or
property.
A-1
Notwithstanding the above, restrictions Mitsubishi may in its sole discretion,
authorize use of the PRODUCT in one or more of the Prohibited
Applications, provided that the usage of the PRODUCT is limited only for
the specific applications agreed to by Mitsubishi and provided further that
no special quality assurance or fail-safe, redundant or other safety features
which exceed the general specifications of the PRODUCTs are required.
For details, please contact the Mitsubishi representative in your region.
A-2
REVISIONS
*The manual number is given on the bottom right of the cover.
Print date*Manual numberRevision
January 2013IB(NA)-0800495-AFirst edition
February 2013IB(NA)-0800495-BChange of the external dimension diagram
November 2015IB(NA)-0800495-CDescriptions regarding the Q series large type
December 2016IB(NA)-0800495-DDescriptions are revised due to compliance with
June 2018IB(NA)-0800495-EDescriptions are revised due to compliance with
base unit are added.
the new China RoHS.
the Chinese standardized law.
This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
6.1 Q Series Large Type Base Unit (AnS Series Size) ............................. 25
6.2 Q Series Large Type Blank Cover (AnS Series Size) ......................... 29
A-4
TERMS
Unless otherwise specified, this manual uses the following generic
terms and abbreviations to explain the Q series large type base units
(AnS series size) and Q series large type blank cover (AnS series size).
TermDescription
Q series large type base unit
(AnS series size)
Q series large type main base
unit (AnS series size)
Q series large type extension
base unit (AnS series size)
Q series large type blank cover
(AnS series size)
Q series
AnS series
High Performance model QCPU
Universal model QCPU
MELSECNET/H remote I/O
module
Q3B
Q3DB
Q5BA generic term for the Q52B and Q55B extension base units
Q6B
QA1S5BAnother term for the QA1S51B extension base unit
QA1S6B
QA6B
A generic term for the Q series large type main base unit
(AnS series size) and Q series large type extension base
units (AnS series size)
A generic term for the Q35BLS, Q38BLS, Q35BLS-D, and
Q38BLS-D MELSEC-Q series main base units
A generic term for the Q65BLS, Q68BLS, Q55BLS,
Q65BLS-D, Q68BLS-D, and Q55BLS-D MELSEC-Q series
extension base units
The abbreviation for the QG69LS MELSEC-Q series blank
cover
The abbreviation for Mitsubishi MELSEC-Q series
programmable controller
The abbreviation for compact types of Mitsubishi MELSECA series programmable controller
A generic term for the Q02CPU, Q02HCPU, Q06HCPU,
Q12HCPU, and Q25HCPU
A generic term for the Q00UJCPU, Q00UCPU, Q01UCPU,
Q02UCPU, Q03UDCPU, Q03UDVCPU, Q03UDECPU,
Q04UDHCPU, Q04UDVCPU, Q04UDEHCPU,
Q06UDHCPU, Q06UDVCPU, Q06UDEHCPU,
Q10UDHCPU, Q10UDEHCPU, Q13UDHCPU,
Q13UDVCPU, Q13UDEHCPU, Q20UDHCPU,
Q20UDEHCPU, Q26UDHCPU, Q26UDVCPU,
Q26UDEHCPU, Q50UDEHCPU, and Q100UDEHCPU
A general term for the QJ72LP25-25, QJ72LP25G, and
QJ72BR15
A generic term for the Q33B, Q35B, Q38B, and Q312B
main base units
A generic term for the Q35DB, Q38DB, and Q312DB
multiple CPU high speed main base units
A generic term for the Q63B, Q65B, Q68B, and Q612B
extension base units
A generic term for the QA1S65B and QA1S68B extension
base units
A generic term for the QA65B and QA68B extension base
units
A-5
A5
B
B
A6
QA6ADP
QA6ADP+A5
TermDescription
A generic term for the A52B, A55B, and A58B extension
base units
A generic term for the A62B, A65B, and A68B extension
base units
The abbreviation for the QA6ADP QA conversion adapter
module
B/A6B
The abbreviation for the A large type extension base unit on
which QA6ADP is mounted
A-6
1. OVERVIEW
1.1Overview
The products are used to replace the AnS series with the Q series when
the existing installation site and cables are utilized.
This manual explains specifications, component devices, part names,
settings, mounting, and installation of the Q series large type base unit
(AnS series size) and Q series large type blank cover (AnS series size).
For contents not explained in this manual such as SAFETY
PRECAUTIONS, EMC and Low Voltage Directives, and general
specifications, refer to the following manual:
QCPU User's Manual (Hardware Design, Maintenance and
Inspection)
1.2Features
This section explains features of the Q series large type base unit (AnS
series size) and Q series large type blank cover (AnS series size).
(1) The Q series large type base unit (AnS series size) is available in
two types; DIN rail mounting type and panel mounting type.
Select the suitable type of a base unit for the operating
environment.
Mounting typeMain base unitExtension base unit
Panel mounting type
DIN rail mounting type
Q35BLS
Q38BLS
Q35BLS-D
Q38BLS-D
Q65BLS
Q68BLS
Q55BLS
Q65BLS-D
Q68BLS-D
Q55BLS-D
1
(2) Since the Q series large type base unit (AnS series size) has the
24
V
D
C
4
m
A
QX40
+
-
2
4
V
D
C
4
m
A
QX40
+
-
2
4
V
D
C
4
m
A
QX40
+
-
2
4V
D
C
4
m
A
QX40
+
-
Q12HCPU
MODE
RU
N
ERR.
USER
B
AT.
BOOT
PULL
USB
RS-232
MELSEC
Q62P
PO
W
E
R
PULL
2
4
V
D
C
4
m
A
Q
X
4
0
+
-
Q series module
Q series large type base unit
(AnS series size)
Q series large type blank cover (AnS series size)
*1
(3) Mount the Q series module on the Q series large type base unit
same mounting dimensions with the AnS series base unit, the
same mounting holes can be utilized.
The following table shows the corresponding models for
replacement.
AnS series base unit
A1S35BQ35BLS
A1S38BQ38BLS
A1S65BQ65BLS
A1S68BQ68BLS
A1S55BQ55BLS
Q series large type base unit
(AnS series size)
(AnS series size).
The renewal tool manufactured by MITSUBISHI ELECTRIC
ENGINEERING COMPANY LIMITED (hereafter, abbreviated
as renewal tool) can be mounted on the module, and a
connector and terminal block used with the AnS series can be
used without wiring change.
*1 To mount the Q series module on the I/O slot of the Q series large type base unit (AnS
series size), always attach the Q series large type blank cover (AnS series size).
2
1.3Supplied Parts
(1) Q series large type main base unit (AnS series size)
(panel mounting type)
ProductModelQuantityRemarks
Q35BLS
Q series large type main base
unit (AnS series size)
Base unit mounting screw-4M5 × 25 screw
This manualIB-08004951-
Safety Guidelines
*1 The Q series large type extension base unit (AnS series size) does not include with the
guidelines.
*1
(2) Q series large type main base unit (AnS series size)
(DIN rail mounting type)
ProductModelQuantityRemarks
Q series large type main base
unit (AnS series size)
DIN rail mounting adapter
End fitting L-1-
End fitting R-1-
Fixing bracket for terminal block
conversion adapter
*1 For a combination of the DIN rail mounting adapter, refer to the following:
Q6DIN1: Q38BLS-D and Q68BLS-D
Q6DIN2: Q35BLS-D, Q65BLS-D, and Q55BLS-D
*2 The stopper for DIN rail mounting adapter is not included with this base unit since the end
fitting is substitutable.
*3 The Q series large type extension base unit (AnS series size) does not include with the
guidelines.
*3
IB-08004231-
(3) Q series large type blank cover (AnS series size)
ProductModelQuantityRemarks
Q series large type blank cover
(AnS series size)
QG69LS1-
4
2. SYSTEM CONFIGURATION
CPU01234567
Power
supply module
CPU module
Q series large type main base unit
(AnS series size) (Q3BLS, Q3BLS-D),
Q series main base unit (Q3B, Q3DB),
or Q series large type main base unit
(Q3BL)
Q series extension base unit (Q5B, Q6B),
Q series large type extension base unit
(AnS series size) (Q6BLS, Q6BLS-D, Q55BLS,
Q55BLS-D), or Q series large type extension base unit
(Q6BL, Q55BL)
Q series extension base unit on which
AnS series module can be mounted
(QA1S5B, QA1S6B)
Q series extension base unit on which
A series module can be mounted
(QA6B)
QA conversion adapter +
A/QnA series extension base unit
(QA6ADP + A5B/A6B)
Main base
unit
Extension
base unit
Slot number
8 9 10 11 12 13 14 15
16 17 18 19 20 21 22 23
24 25 26 27 28 29 30 31
32 33 34 35 36 37 38 39
2.1System Configuration
This section explains system configuration when using the Q series
large type base unit (AnS series size). The following modules can be
mounted on the CPU slot of the Q series large type base unit (AnS
series size).
• High Performance model QCPU
• Universal model QCPU (except Q00UJCPU)
• MELSECNET/H remote I/O module
(1) System configuration using the High Performance model QCPU