Mitsubishi PM800HSA120 Datasheet

MITSUBISHI INTELLIGENT POWER MODULES
PM800HSA120
FLA T-BASE TYPE
INSULA TED PACKAGE
A D
R (2 REQD)
X
W
(4 HOLES)
G
S φ
FO SR IN
φK
φL
φM
H
J
1
VI
1.5 OHM Rfo
FO
5 2
SR
3
CI
4
VC
C1
300 pf
Outline Drawing and Circuit Diagram
VCC
GND
TEMP OUT1 OUT2 SENS SINK
TYP
Q
TYP
DD
E
V SQ.(5 PLACES) TYP
E
AA
B
Description:
Mitsubishi Intelligent Power Mod­ules are isolated base modules de­signed for power switching applica-
P
tions operating at frequencies to 20kHz. Built-in control circuits pro-
BB
C
12 345
T F CC
C
tection for the IGBT and free-wheel diode power devices.
Rref
C
Tm
AMP
Features:
u Complete Output Power
Circuit
u Gate Drive Circuit u Protection Logic
E
– Short Circuit – Over Current – Over Temperature – Under Voltage
Dimensions Inches Millimeters
A 3.94 100.0 B 5.20 132.0 C 1.33 33.7 D 3.23±0.010 82.0±0.25 E 4.33±0.010 110.0±0.25 F 2.84 72.0 G 1.42+0.04/-0.02 36.0+1/-0.5 H 0.53 13.5
J 0.06 1.5 K 0.17 4.4 L 0.15 3.8
M 0.06 1.5 N 0.35 9.0
P 0.53 13.5
Dimensions Inches Millimeters
Q 0.10 2.54 R M8 Metric M8 S φ 6.5 φ 6.5
T 0.24 26.0 U 0.26 6.5 V 0.25 0.64
W 0.20 5.0
X 1.97 50.0
AA 0.71 18.0 BB 0.55 14.0 CC 0.39 10.0 DD 1.14. 29.0
Applications:
u Inverters u UPS u Motion/Servo Control u Power Supplies
Ordering Information:
Example: Select the complete part number from the table below
-i.e. PM800HSA120 is a 1200V, 800 Ampere Intelligent Power Mod­ule.
Type Current Rating V
Amperes Volts (x 10)
PM 800 120
CES
Sep.1998
MITSUBISHI INTELLIGENT POWER MODULES
PM800HSA120
FLA T-BASE TYPE
INSULA TED PACKAGE
Absolute Maximum Ratings, Tj = 25°C unless otherwise specified
Ratings Symbol PM800HSA120 Units Power Device Junction Temperature T Storage T emperature T Case Operating Temperature T Mounting Torque, M6 Mounting Screws 3.92 ~ 5.88 N · m Mounting Torque, M8 Main Terminal Screws 8.83 ~ 10.8 N · m Module Weight (Typical) 1170 Grams Supply Voltage Protected by OC and SC (VD = 13.5 - 16.5V , Inverter Part) V Isolation Voltage (Main Terminal to Baseplate, AC 1 min.) V
j
stg
C
CC(prot.)
iso
Control Sector
Supply Voltage Applied between (V1-VC)V Input Voltage Applied between (C1-VC)V Fault Output Supply Voltage (Applied between Fo-Vc)V Fault Output Current (Fault Current of FO T erminal) I
D
CIN
FO
FO
-20 to 150 °C
-40 to 125 °C
-20 to 100 °C
800 Volts
2500 Vrms
20 Volts 10 Volts 20 Volts 20 mA
IGBT Inverter Sector
Collector-Emitter Voltage (VD = 15V, V Collector Current, (TC = 25°C) I Peak Collector Current, (TC = 25°C) I Collector Dissipation P
= 5V) V
CIN
CES
C
CP
C
1200 Volts
800 Amperes 1600 Amperes 4630 Watts
Sep.1998