MITSUBISHI INTELLIGENT POWER MODULES
PM800HSA060
FLA T-BASE TYPE
INSULA TED PACKAGE
A
JK
L
M
LABEL
5 FO
4 VC
3 CI
2 SR
1 V1
VI
FO
SR
CI
VC
V (2 REQD)
U φ (4 HOLES)
G
N
FO
SR
IN
CE
VCC
TEMP
OUT1
OUT2
SENS
SINK
GND
Outline Drawing and Circuit Diagram
Dimensions Inches Millimeters
A 3.46 88.0
B 3.85 98.0
C 1.16 29.5
D 2.76 70.0
E 3.15±0.01 80.0±0.25
F 2.56 65.0
G 1.34+0.04/-0.02 34.0+1/-0.5
H 0.63 16.0
J 0.63 16.1
K 1.00 25.4
L 0.20 5.1
S φ
(2 PLS)
B
E
R
W
12 34 5
TYP
Q
T SQ PIN
(5 PLS)
F
D
H
P
C
C
E
Dimensions Inches Millimeters
M 1.83 46.6
N 0.28 7.0
P 0.59 15.0
Q 0.10 2.54
R 0.71 18.0
S 0.08 2.0
T 0.02 SQ 0.64 SQ
U 0.26 6.5
VM8M8
W 0.79 20.0
Description:
Mitsubishi Intelligent Power Modules are isolated base modules designed for power switching applications operating at frequencies to
20kHz. Built-in control circuits provide optimum gate drive and protection for the IGBT and free-wheel
diode power devices.
Features:
u Complete Output Power
Circuit
u Gate Drive Circuit
u Protection Logic
– Short Circuit
– Over Current
– Over Temperature
– Under Voltage
Applications:
u Inverters
u UPS
u Motion/Servo Control
u Power Supplies
Ordering Information:
Example: Select the complete
part number from the table below
-i.e. PM800HSA060 is a 600V,
800 Ampere Intelligent Power Module.
Type Current Rating V
Amperes Volts (x 10)
PM 800 60
CES
Sep.1998
MITSUBISHI INTELLIGENT POWER MODULES
PM800HSA060
FLA T-BASE TYPE
INSULA TED PACKAGE
Absolute Maximum Ratings, Tj = 25°C unless otherwise specified
Ratings Symbol PM800HSA060 Units
Power Device Junction Temperature T
Storage T emperature T
Case Operating Temperature T
Mounting Torque, M6 Mounting Screws — 3.92 ~ 5.88 N · m
Mounting Torque, M8 Main Terminal Screws — 8.83 ~ 10.8 N · m
Module Weight (Typical) — 630 Grams
Supply Voltage Protected by OC and SC (VD = 13.5 ~16.5V, Inverter Part) V
Isolation Voltage (Main Terminal to Baseplate, AC 1 min.) V
j
stg
C
CC(prot.)
iso
Control Sector, Tj = 25°C unless otherwise specified
Supply Voltage (Applied between V1-VC)V
Input Voltage (Applied between C1-VC)V
Fault Output Supply Voltage (Applied between FO and VNC)V
Fault Output Current (Sink Current of FO Terminal) I
D
CIN
FO
FO
-20 to 150 °C
-40 to 125 °C
-20 to 100 °C
400 Volts
2500 Vrms
20 Volts
10 Volts
20 Volts
20 mA
IGBT Inverter Sector, Tj = 25°C unless otherwise specified
Collector-Emitter Voltage (VD = 15V, V
Collector Current, (TC = 25°C) I
Peak Collector Current, (TC = 25°C) I
Collector Dissipation P
= 5V) V
CIN
CES
C
CP
C
600 Volts
800 Amperes
1600 Amperes
2100 Watts
Sep.1998