Mitsubishi PKFY-P63VKM-E.TH, PKFY-P100VKM-E.TH Parts Catalog

Page 1
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
PARTS CATALOG
November 2008
No. OCB447
R407C R22R410A
Indoor unit [Model names] [Service Ref.]
PKFY-P63VKM-E
PKFY-P100VKM-E
PKFY-P63VKM-E.TH
PKFY-P100VKM-E.TH
CONTENTS
1. RoHS PARTS LIST
2. OPTIONAL PARTS
Note:
RoHS compliant products have <G> mark on the spec name plate.
.....................................................
2 6
INDOOR UNIT
SERVICE MANUAL (OCH447)
Page 2
1
RoHS PARTS LIST
PANEL AND HEAT EXCHANGER PARTS PKFY-P63VKM-E.TH PKFY-P100VKM-E.TH
1
2
3
4
5
5
4
6
9
8
7
12
11
10
13
2
Page 3
No.
Part No. Part Name
RoHS
Specifi cation
Q'ty/set
PKFY-P•VKM-E.TH
63 100
Remarks
(Drawing No.)
Wiring
Diagram
Symbol
Recom-
mended
Q'ty
1 G E12 C92 970 2 G E12 C92 234 BOX 1 1 3 G E17 518 000 PANEL ASSEMBL Y 1 1 4 G E12 408 142 CATCH 1 1 2pcs/set 5 G E12 C92 067 SCREW CAP 1 1 3pcs/set 6 G E12 C92 010 FRONT PANEL (NW) 1 1 7 G E12 C92 100 8 G E12 C92 975 CORNER BOX R 1 1
G E17 518 620 HEAT EXCHANGER 1
9
G E17 519 620 HEAT EXCHANGER 1 10 G E12 527 667 UNION (LIQ) 1 1 11 G E12 C92 666 UNION (GAS) 1 1
G E17 518 640 12
G E17 519 640 13 G E17 518 980 JOINT ASSEMBLY 1 1
INSTALLATION PLATE
CA TECHIN AIR FILTER
LINEAR EXPANSION VALVE LINEAR EXPANSION VALVE
11
22
1 LEV
1 LEV
33
Page 4
FUNCTIONAL PARTS PKFY-P63VKM-E.TH PKFY-P100VKM-E.TH
1
18
2 3
19
4
16
15
17
14
13
19
5
21
20
12
6
11
7
10
98
22
23
CHECK
TEST RUN
MODEL SELECT
NOT AVAILABLE
ON/OFF TEMP
°C
AMPM
AMPM
TEMP.
ON/OFF
4
Page 5
Part numbers that are circled are not shown in the illustration.
Q'ty/set
No.
1 G E12 C92 302 LINE FLOW FAN 1 2 G E12 751 509 BEARING MOUNT 1 3 G E12 001 504 SLEEVE BEARING 1 4 G E12 408 702 DRAIN HOSE 1 5 G E17 518 235 NOZZLE ASSEMBLY 1 6 G E12 C92 040 VANE UPPER 1 7 G E12 C92 041 VANE LOWER 1 8 G E12 749 303 VANE MOTOR 1 MV
Part No. Part Name
RoHS
Specifi cation
PKFY-P63,100
VKM-E.TH
Remarks
(Drawing No.)
Wiring
Diagram
Symbol
Recom-
mended
Q'ty
9 G E17 518 468 10 G E12 C92 095 RECEIVER HOLDER 1 11 G E17 518 308 12 G E17 518 447 13 G E17 518 782 SWITCH HOLDER 1 14 G E17 249 375 TERMINAL BLOCK 2P(1,2) 1 TB15 15 G E17 519 375 TERMINAL BLOCK 16 G E17 518 375 TERMINAL BLOCK 3P(L,N,;) 1 TB2 17 G E17 518 456 ADDRESS BOARD 1 A.B. 18 G E17 518 307 THERMISTOR 1 19 G E12 C92 300 FAN MOTOR 1 MF 20 G E12 C92 333 MOTOR BAND 1 21 G E17 518 541 WATER COVER 1 22 G 23 G 24 G E17 518 087 25 G E12 A49 382 FUSE 3.15A 250V 1 FUSE
-
-
RECEIVER P.C.BOARD
ROOM TEMP. THERMISTOR INDOOR CONTOLLER BOARD
3P(M1,M2,S)
WIRELESS REMOTE CONTROLLER REMOTE CONTROLLER CABLE ASSY (ADDRESS)
PAR-FL32MA PAR-21MAA
1 W.B.
1 TH21 1 I.B., S.B.
1 TB5
TH22/23, TH24
1 1 1
5
Page 6
2
2-1. WIRELESS REMOTE CONTROLLER
2-2. WIRED REMOTE CONTROLLER (MA REMOTE CONTROLLER)
2-3. WIRED REMOTE CONTROLLER (ME REMOTE CONTROLLER)
2-4. DRAIN PUMP
OPTIONAL PARTS
Part No. PAR-FL32MA
Part No. PAR-21MAA
Part No. PAR-F27MEA
Part No. PAC-SH94DM-E
6
Page 7
77
Page 8
TM
HEAD OFFICE : TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU TOKYO 100-8310, JAPAN
Copyright 2008 MITSUBISHI ELECTRIC ENGINEERING CO., LTD. Distributed in Nov. 2008 No. OCB447 PDF 6 Made in Japan
New publication, effective Nov. 2008 Specifications subject to change without notice
Loading...