THIS OPERATION MANUAL IS IMPORTANT
TO YOU.
PLEASE READ IT BEFORE USING YOUR
DIGITAL MONOCHROME PRINTER.
DIGITAL MONOCHROME
PRINTER
This digital monochrome printer complies with the requirements of the EC Directive 89/
336/EEC, 73/23/EEC, 93/42/EEC and 93/68/EEC.
The electro-magnetic susceptibility has been chosen at a level that gains proper
operation in residential areas, on business and light industrial premises and on smallscale enterprises, inside as well as outside of the buildings. All places of operation are
characterised by their connection to the public low voltage power supply system.
FOR THE MODEL P91DW(UB) ONLY
WARNING:
In the USA or Canada, use the AC power cord according to the recommendations as
below, in order to comply with UL2601-1 and CAN/CSA C22.2 No. 601.1.
Case 1. Connect to the 120V receptacle of the room or the host equipment.
The AC power cord should be UL or CSA approved and consist of type SJT, size
16 or 18AWG, length 2.5m or shorter cord with IEC320/C13 type, 125V 10A or
higher rating connector and NEMA 5-15 type, 125V 10A or higher rating, Hospital
Grade plug.
Case 2. Connect to the 230V receptacle of the room or the host equipment.
The AC power cord should be UL or CSA approved and consist of type SJT, size
16 or 18AWG, length 2.5m or shorter cord with IEC320/C13 type, 250V 10A or
higher rating connector and NEMA 6-15 type, 250V 10A or higher rating, Hospital
Grade plug.
Case 3. Connect to the 120V receptacle of the host equipment.
The AC power cord should be UL or CSA approved and consist of type SJT, size
16 or 18AWG, length 2.5m or shorter cord with IEC320/C13 type, 125V 10A or
higher rating connector and IEC320-2.2/E type, 125V 10A or higher rating plug.
Case 4. Connect to the 230V receptacle of the host equipment.
The AC power cord should be UL or CSA approved and consist of type SJT, size
16 or 18AWG, length 2.5m or shorter cord with IEC320/C13 type, 250V 10A or
higher rating connector and IEC320-2.2/E type, 250V 10A or higher rating plug.
CAUTION:
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his or her own expense.
Information:
This class A digital apparatus complies with Canadian ICES-003.
"CLASSIFIED BY UNDERWRITERS LABORATORIES INC.®
WITH RESPECT TO ELECTRIC SHOCK, FIRE AND MECHANICAL HAZARDS ONLY IN
ACCORDANCE WITH UL2601-1 AND CAN/CSA C22.2 No. 601.1"
CAUTION:
RISK OF ELECTRIC SHOCK DO NOT OPEN.
TO REDUCE THE RISK OF ELECTRIC SHOCK,DO NOT REMOVE COVER (OR
BACK)
NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of uninsulated "dangerous voltage"
within the product's enclosure that may be of sufficient magnitude to constitute a
risk of electric shock.
The exclamation point within an equilateral triangle is intended to alert the user
to the presence of important operating and maintenance (servicing) instructions
in the literature accompanying the appliance.
The “Caution, hot surface” symbol indicates that the marked item may be hot
and should not be touched.
The “ON/OFF” symbol indicates connection to or disconnection from the mains,
at least for mains switches.
The “Equipotentiality” symbol identifies the terminals connected each other. The
potential of various parts of equipment or of a system is equalized.
The “Alternating current” symbol indicates that the equipment is suitable for
alternating current only.
When you dispose of the unit or accessories, you must obey the law in the relative area
or country and/or regulation in the relative hospital.
WARNING:
Install and use this appliance in accordance with the operation manual for safety and
EMC (Electromagnetic Compatibility). If it is not installed and used in accordance with
the operation manual, it may cause interference to other equipment and/or other risk.
To prevent fire or shock hazard, do not expose this appliance to rain or moisture.
This appliance must be earthed.
In Europe, use the AC power cord according to the recommendations as below, in order
to comply with EN60601-1 and EN60950.
Connect to the 230V receptacle of the room or the host equipment.
The AC power cord should be VDE approved and consist of core size 1mm
length 2.5m or shorter cord with IEC320/C13 type, 250V 10A or higher rating connector
and CEE(7)VII type or IEC 320-2.2/E type, 250V 10A or higher rating plug.
Use the USB cable according to the recommendations as below, in order to comply with
EN60601-1-2.
The USB cable with appropriate plug should be 2 m long or shorter, comply with USB 2.0
standard High speed requirements and USB IF (USB Implementers Forum) approved.
This product is to be employed with medical equipment, just for reference purpose, not
for medical diagnostic purpose.
2
or bigger,
INSTRUCTIONS FOR MEDICAL USE
<according to the Medical Safety/EMC standard IEC/EN 60601-1-2>
MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC and needs
to be installed and put into service according to the EMC information provided in the ACCOMPANYING DOCUMENTS.
Portable and mobile RF communications equipment can affect MEDICAL ELECTRICAL
EQUIPMENT.
Technical description
List of all cables and maximum length of the cable and transducers and other
ACCECCORIES
Reference page in this operation manual
This page, the previous pages for safety and page 22
for accessories
This page, the previous pages for safety and page 22
for accessories
Page 3 for thermal paper, Page 22 for accessories
AC power cord
USB cable
Thermal paper
Maximum length
2.5 m
2 m
WARNING:
The use of ACCESSORIES, transducers and cables other than those specified, with the
exception of transducers and cables sold by the manufacturer of the Model P93DW/P93DE
as replacement parts for internal components, may result in increased EMISSIONS or
decreased IMMUNITY of the Model P93DW/P93DE.
WARNING:
The Model P93DW/P93DE should not be used adjacent to or stacked with other equipment
and that if adjacent or stacked use is necessary, the Model P93DW/P93DE should be
observed to verify normal operation in the configuration in which it will be used.
Guidance and manufacturer's declaration - electromagnetic emissions
The Model P93DW/P93DE is intended for use in the electromagnetic environment specified below.
The customer or user of the Model P93DW/P93DE should assure that it is used in such an
environment.
Emission test
RF emissions
CISPR 11/EN 55011
Compliance
Group 1
Electromagnetic environment - guidance
The Model P93DW/P93DE uses RF energy only for its
internal function. Therefore, its RF emissions are very
low and are not likely to cause interference in nearby
electronic equipment.
The Model P93DW/P93DE is suitable for use in all
establishments, including domestic establishments
and those directly connected to public low-voltage
power supply network that supplies buildings used for
Guidance and manufacturer's declaration - electromagnetic immunity
The Model P93DW/P93DE is intended for use in the electromagnetic environment specified below.
The customer or user of the Model P93DW/P93DE should assure that it is used in such an
environment.
Immunity test
Electrostatic
discharge (ESD)
IEC/EN 61000-4-2
Electrical fast
transient/burst
IEC/EN 61000-4-4
Surge
IEC/EN 61000-4-5
Voltage dips, short
interruptions and
voltage variations
on power supply
input lines
IEC/EN 61000-4-11
Power frequency
(50/60 Hz)
magnetic field
IEC/EN 61000-4-8
NOTE
U
is the a.c. mains voltage prior to application of the test level.
T
IEC/EN 60601
test level
±6 kV contact
±8 kV air
±2 kV for power
supply lines
±1 kV for input
/output lines
±1 kV
differential
mode
±2 kV common
mode
< 5%
U
T
(> 95% dip in
for 0,5 cycle
40%
U
T
(60% dip in
for 5 cycles
70%
U
T
(30% dip in
for 25 cycles
< 5%
U
T
(> 95% dip in
for 5 sec.
3 A/m
Compliance
level
±6 kV contact
±8 kV air
±2 kV for power
supply lines
±1 kV for input
/output lines
±1 kV
differential
mode
±2 kV common
mode
< 5%
U
)
(> 95% dip in
T
for 0,5 cycle
40%
U
)
(60% dip in
T
for 5 cycles
70%
U
)
(30% dip in
T
for 25 cycles
< 5%
U
)
(> 95% dip in
T
for 5 sec.
3 A/m
Electromagnetic environment - guidance
Floors should be wood, concrete or
ceramic tile. If floors are covered with
synthetic material, the relative humidity
should be at least 30%.
Mains power quality should be that of a
typical commercial or hospital
environment.
Mains power quality should be that of a
typical commercial or hospital
environment.
U
T
U
T
U
T
U
T
Mains power quality should be that of a
typical commercial or hospital
U
)
T
environment. If the user of the Model
P93DW/P93DE requires continued
operation during power mains
U
)
T
interruptions, it is recommended that the
Model P93DW/P93DE be powered from
an uninterruptible power supply or a
battery.
U
)
T
U
)
T
Power frequency magnetic fields should
be at levels characteristic of a typical
commercial or hospital environment.
Guidance and manufacturer's declaration - electromagnetic immunity
The Model P93DW/P93DE is intended for use in the electromagnetic environment specified below.
The customer or user of the Model P93DW/P93DE should assure that it is used in such an
environment.
Immunity test
Conducted RF
IEC/EN 61000-4-6
Radiated RF
IEC/EN 61000-4-3
IEC/EN 60601
test level
3 Vrms
150 kHz to 80
MHz
3 V/m
80 MHz to 2,5
GHz
Compliance
level
3 Vrms
3 V/m
Electromagnetic environment - guidance
Portable and mobile RF communications
equipment should be used no closer to
any part of the Model P93DW/P93DE,
including cables, than the recommended
separation distance calculated from the
equation applicable to frequency of the
transmitter.
Recommended separation distance
d=1,2√P
d=1,2√P 80 MHz to 800 MHz
d=2,3√P 800 MHz to 2,5 GHz
where P is the maximum output power
rating of the transmitter in watts (W)
according to the transmitter manufacturer
and d is the recommended separation
distance in meters (m).
Field strengths from fixed RF
transmitters, as determined by an
electromagnetic site survey,
less than the compliance level in each
frequency range.
b
a
should be
Interference may occur in the vicinity of
equipment marked with the following
symbol:
NOTE1. At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE2. These guidelines may not apply in all situations. Electromagnetic propagation is
affected by absorption and reflection from structures, objects and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless)
telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV
broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic
environment due to fixed RF transmitters, an electromagnetic site survey should be
considered. If the measured field strength in the location in which the Model P93DW/P93DE
is used exceeds the applicable RF compliance level above, the Model P93DW/P93DE
should be observed to verify normal operation. If abnormal performance is observed,
additional measures may be necessary, such as reorienting or relocating the Model
P93DW/P93DE.
b
Over the frequency range 150 kHz to 80 MHz, field strength should be less than 3 V/m.
Recommended separation distances between
Portable and mobile RF communications equipment and the Model P93DW/P93DE
The Model P93DW/P93DE is intended for use in the electromagnetic environment in which
radiated RF disturbances are controlled. The customer or user of the Model P93DW/P93DE can
help prevent electromagnetic interference by maintaining a minimum distance between portable
and mobile RF communications equipment (transmitters) and the Model P93DW/P93DE as
recommended below, according to the maximum output power of the communications equipment.
Rated maximum output
power of transmitter
W
0,01
0,1
1
10
100
For transmitters rated at maximum output power not listed above, the recommended separation
distance d in meters (m) can be estimated using the equation applicable to the frequency of the
transmitter, where P is the maximum output power rating of the transmitter in watts (W)
according to the transmitter manufacturer.
NOTE1. At 80 MHz and 800 MHz, the separation distance for higher frequency range applies.
NOTE2. These guidelines may not apply in all situations. Electromagnetic propagation is
affected by absorption and reflection from structures, objects and people.
Separation distance according to frequency of transmitter
In the interest of safety, please observe the following
precautions:
POWER REQUIREMENT
This digital monochrome printer is designed for operation
on 100-240V AC 50/60Hz. Never connect to any outlet or
power supply having a different voltage or frequency.
PROTECTIVE MEASURES
IF ABNORMALITIES ARISE, . . .
Use of the unit during emission of smoke or abnormal
sounds (without adopting countermeasures) is
dangerous. In such a case, unplug the power cord from
the source outlet immediately, and request maintenance services from the sales dealer.
NEVER INSERT ANY OBJECT INTO THE UNIT
Foreign objects of any kind inserted into this unit constitute
a safety hazard and can cause extensive damage.
If any object should be inserted into the unit, unplug the
power cord, then contact the sales dealer.
DO NOT PLACE ANYTHING ON THE UNIT
Heavy objects placed on the unit can cause damage or
obstruct proper ventilation.
PROTECT THE POWER CORD
Damage to the power cord may cause fire or shock
hazard. When unplugging, hold by the plug only and
remove carefully.
Never put heavy objects on the power cord. The cord may
be damaged causing a fire or electric shock.
DO NOT PLACE WATER CONTAINERS ON THE UNIT
Do not place flower vases, and other water-holding containers on the unit. If, for some reason, water seeps to the
inside of the unit, unplug the power cord from the
source outlet, and contact the sales dealer. If used without
corrective measures, the unit may be damaged.
WARNING : THIS APPARATUS MUST BE EARTHED.
AVERTISSEMENT : CET APPAREIL DOIT ETRE MIS A
LA TERRE.
This equipment is classified as class 1, according to the
type of protection against electric shock.
DO NOT REMOVE THE CABINET
Touching internal parts is dangerous or may lead to
malfunction. Contact the sales dealer to carry out internal checks and/or adjustments. Before opening the
cover to clear a paper jam, etc., be sure to disconnect
the power cord plug.
DO NOT ATTACH A SCREW MORE THAN 6MM LONG
ON THE BOTTOM
If a screw more than 6 mm long is attached on the bottom
of the printer, it may cause internal damage.
PROTECT AGAINST DEW FORMATION
In extremely cold regions, if the unit is moved quickly from
an extremely cold place to a warmer one, dew is likely to
be formed. If dew is formed, printing is not possible.
OPERATING AMBIENT TEMPERATURE RANGE
The operating ambient temperature range is 5°C-40°C
(41°F-104°F), and humidity of 20-80%.
BE CAREFUL AROUND PRINT PAPER EXIT SLOT
Do not insert your hand or any material into the paper exit
slot during printing.
Do not touch the cutter blade inside the paper exit slot.
Otherwise, your finger will be injured.
DO NOT TOUCH THE THERMAL HEAD AND CUTTER
Do not touch the thermal head (located inside the unit)
and the cutter blade.
The thermal head is heated to high temperature.
This may cause injury.
INSTALLATION LOCATIONS
MAINTAIN GOOD VENTILATION
Ventilation slots and holes are provided on sides of this
unit.
Place the unit on a hard and level surface and locate at
least 4" (10cm) from walls to ensure proper ventilation.
UNSUITABLE LOCATIONS
Avoid shaky places or hot-springs areas where hydrogen
sulfide and acidic ions are likely to be generated.
PLACES WITH HIGH HUMIDITY AND DUST
Do not place the unit at locations with high humidity and/
or dust. They can cause extensive damage.
Avoid places where the unit is likely to contact oily fumes
and vapors.
PLACES LIKELY TO BE EXTREMELY HOT
Places exposed to direct sunlight, or near heating
appliances can attain extremely high temperatures,
which may deform the cabinet, or can become a
prime cause of damage.
SET THE UNIT ON A FLAT SURFACE
Do not use the unit when inclined ±20° in vertical or
horizontal direction, or in an unstable place.
Uneven surfaces may disturb paper feeding or ventilation, or affect the performance of the unit.
2
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.