Mitsubishi Electronics P91DW-UB User Manual

DIGITAL MONOCHROME PRINTER
MODEL
OPERATION MANUAL
FUNC DOWN SETUP
OPEN
THIS OPERATION MANUAL IS IMPORTANT TO YOU. PLEASE READ IT BEFORE USING YOUR DIGITAL MONOCHROME PRINTER.
GAMMA FEED
COPY
DIGITAL MONOCHROME PRINTER
This digital monochrome printer complies with the requirements of the EC Directive 89/336/EEC, 73/23/EEC, 93/42/EEC and 93/68/EEC. The electro-magnetic susceptibility has been chosen at a level that gains proper operation in residential areas, on business and light industrial premises and on small­scale enterprises, inside as well as outside of the buildings. All places of operation are characterised by their connection to the public low voltage power supply system.
FOR THE MODEL P91DW(UB) ONLY
WARNING:
In the USA or Canada, use the AC power cord according to the recommendations as below, in order to comply with UL2601-1 and CAN/CSA C22.2 No. 601.1.
Case 1. Connect to the 120V receptacle of the room or the host equipment.
The AC power cord should be UL or CSA approved and consist of type SJT, size 16 or 18AWG, length 2.5m or shorter cord with IEC320/C13 type, 125V 10A or higher rating connector and NEMA 5-15 type, 125V 10A or higher rating, Hospital Grade plug.
Case 2. Connect to the 230V receptacle of the room or the host equipment.
The AC power cord should be UL or CSA approved and consist of type SJT, size 16 or 18AWG, length 2.5m or shorter cord with IEC320/C13 type, 250V 10A or higher rating connector and NEMA 6-15 type, 250V 10A or higher rating, Hospital Grade plug.
Case 3. Connect to the 120V receptacle of the host equipment.
The AC power cord should be UL or CSA approved and consist of type SJT, size 16 or 18AWG, length 2.5m or shorter cord with IEC320/C13 type, 125V 10A or higher rating connector and IEC320-2.2/E type, 125V 10A or higher rating plug.
Case 4. Connect to the 230V receptacle of the host equipment.
The AC power cord should be UL or CSA approved and consist of type SJT, size 16 or 18AWG, length 2.5m or shorter cord with IEC320/C13 type, 250V 10A or higher rating connector and IEC320-2.2/E type, 250V 10A or higher rating plug.
NOTE:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communica­tions. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interfer­ence at his or her own expense.
Information:
This class A digital apparatus complies with Canadian ICES-003.
"CLASSIFIED BY UNDERWRITERS LABORATORIES INC.® WITH RESPECT TO ELECTRIC SHOCK, FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL2601-1 AND CAN/CSA C22.2 No. 601.1"
CAUTION:
RISK OF ELECTRIC SHOCK DO NOT OPEN.
TO REDUCE THE RISK OF ELECTRIC SHOCK,DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
When you dispose of the unit or accessories, you must obey the law in the relative area or country and/or regulation in the relative hospital.
WARNING:
Install and use this appliance in accordance with the opration manual for safety and EMC (Electromagnetic Compatibility). If it is not installed and used in accordance with the operation manual, it may cause interference to other eequipment and/or other risk.
To prevent fire or shock hazard, do not expose this appliance to rain or moisture.
This appliance must be earthed.
In Europe, use the AC power cord acording to the recommendations as below, in order to comply with EN60601-1 and EN60950. Connect to the 230V receptacle of the room or the host equipment. The AC power cord should be VDE approved and consist of core size 1mm length 2.5m or shorter cord with IEC320/C13 type, 250V 10A or higher rating connector and CEE(7)VII type or IEC 320-2.2/E type, 250V 10A or higher rating plug.
Use the USB cable according to the recommendations as below, in order to comply with EN60601-1-2. The USB cable with appropriate plug should be 2m long or shorter, comply with USB 2.0 standard High speed requirements and USB IF (USB Implementers Forum) approved.
This product is to be employed with medical equipment, just for reference purpose, not for medical diagnostic purpose.
2
or bigger,
Information:
This equipment complies with EN55011, class B, group 1.
CONTENTS
1
11
1
CONTENTS................................................................. 1
11 22
2
PRECAUTIONS ..................................................... 2 - 4
22 33
3
UNPACKING ............................................................... 5
33 44
4
FEATURES AND FUNCTIONS
44
Front Panel .............................................................. 6
Rear Panel ............................................................... 7
55
5
INSTALLATION OF PAPER .................................. 8 - 9
55 66
6
EXAMPLE OF CONNECTION .................................. 10
66 77
7
PRINTING .......................................................... 11 - 12
77 88
8
ADJUSTMENT OF PRINT PICTURE
88
Selection of Gamma (γ) Curve ............................. 13
99
9
SETTING OF FUNCTION MODE ...................... 14 - 15
99 AA
A
ERROR DISPLAY .............................................. 16 - 17
AA BB
B
STATUS AND MODES .............................................. 18
BB CC
C
USE OF CLEANING PAPER .................................... 19
CC DD
D
MAINTENANCE ........................................................ 20
DD EE
E
SPECIFICATIONS .................................................... 21
EE
1
PRECAUTIONS
2
In the interest of safety, please observe the following pre­cautions:
POWER REQUIREMENT
This Digital monochrome printer is designed for opera­tion on 120/220-240V AC 50/60Hz in U.S.A and Canada, 220-240V AC 50/60Hz in Europe. Never connect to any outlet or power supply having a different voltage or fre-
PROTECTIVE MEASURES
IF ABNORMALITIES ARISE, . . .
Use of the unit during emission of smoke or abnormal sounds (without adopting countermeasures) is dangerous. In such a case, unplug the power cord from the source outlet immediately, and request maintenance services from the sales dealer.
NEVER INSERT ANY OBJECT INTO THE UNIT
Foreign objects of any kind inserted into this unit consti­tute a safety hazard and can cause extensive damage. If any object should be inserted into the unit, unplug the power cord, then contact the sales dealer.
DO NOT PLACE ANYTHING ON THE UNIT
Heavy objects placed on the unit can cause damage or obstruct proper ventilation.
PROTECT THE POWER CORD
Damage to the power cord may cause fire or shock haz­ard. When unplugging, hold by the plug only and remove carefully. Never put a heavy thing on the power cord. The cord may be damaged causing a fire or electric shock.
DO NOT PLACE WATER CONTAINERS ON THE UNIT
Do not place flower vases, and other water-holding con­tainers on the unit. If, for some reason, water seeps to the inside of the unit, unplug the power cord from the source outlet, and contact the sales dealer. If used without corrective measures, the unit may be damaged.
quency.
WARNING : THIS APPARATUS MUST BE EARTHED. AVERTISSEMENT : CET APPAREIL DOIT ETRE MIS A LA TERRE.
This equipment is classified as class I, type B according to the type of protection against electric shock.
DO NOT REMOVE THE CABINET
Touching internal parts is dangerous, besides, it may lead to malfunction. Contact the sales dealer to carry out inter­nal checks and/or adjustments. Before opening the cover for eliminating a jammed paper, etc., be sure to discon­nect the power cord plug.
PLACE THE UNIT ON A HORIZONTAL LEVEL
The unit is likely to be affected if it is placed in slanted conditions or in unstable places.
PROTECT AGAINST DEW FORMATION
In extremely cold regions, if the unit is moved quickly from an extremely cold place to a warmer one, dew is likely to be formed. If dew is formed, printing is not possible.
OPERATING AMBIENT TEMPERATURE RANGE
The operating ambient temperature range is 5°C-40°C (41°F-104°F), and humidity of 20-80%.
BE CAREFUL AROUND PRINT PAPER EXIT SLIT
Do not insert your hand or any material into the paper exit slit during printing. Do not touch the cutter blade inside the paper exit slit. Otherwise, your finger will be injured.
DO NOT TOUCH THE THERMAL HEAD AND CUTTER
Do not touch your hand to the thermal head (located in­side the unit) and the cutter blade. The thermal head is heated to high temperature. This may cause injury.
INSTALLATION LOCATIONS
MAINTAIN GOOD VENTILATION
Ventilation slots and holes are provided on sides of this unit. Place the unit on a hard and level surface and locate at least 4" (10cm) from walls to ensure proper ventilation.
UNSUITABLE LOCATIONS
Avoid shaky places or hot-springs areas where hydrogen sulfide and acidic ions are likely to be generated.
PLACES WITH HIGH HUMIDITY AND DUST
Do not place the unit at locations with high humidity and/or dust. They can cause extensive damage. Avoid places where the unit is likely to contact oily fumes and vapors.
PLACES NOT LIKELY TO BE EXTREMELY HOT
Places exposed to direct sunlight, or near heating appliances can attain extremely high temperatures, which may deform the cabinet, or can become a prime cause of damage.
SET THE UNIT ON A FLAT PLACE
Do not use the unit in the state inclined ±20° in vertical or horizontal direction, or in an unstable place. It will disturb paper feeding or ventilation, or affects the set.
2
FOR LONG OPERATING LIFE
UNSUITABLE MATERIALS FOR THE UNIT
Many plastic components are used in the backside. Coat flaking and deformation are likely to occur if the unit is wiped with chemical dusters, benzine, thinner or any other sol­vent, if rubbers or PVC items are left in contact with the unit for extended duration, or if the unit is sprayed with insecticide.
CARE OF THE CABINET
Unplug and clean with a soft cloth slightly moistened with a mild soap and water solution. Allow to dry completely before operating. Never use petroleum base solutions or abrasive cleaners.
HEAD ABRASION
The thermal head, like the video head, wears out. When it is abraded, it becomes hard to print out fine details of the picture. In such a case, it is necessary to replace the thermal head. Consult with the sales dealer for replacing the head.
WHEN A DEFECT IS FOUND
When you detect smoke or smell from the unit, disconnect
THERMAL PAPER
immediately the power cord plug from a wall socket and ask the agent for repair. Dangerous if the unit is operated in that state.
CONNECTION DEVICES
Read thoroughly "Operating Precautions" of the instruc­tion booklets for other devices connected with the Digital monochrome printer. Do not disconnect the power cord during printing.
CAUTION ON RELOCATING
When transporting this unit, make sure it is not likely to be subjected to impacts. They can be a prime cause for dam­age. Further, make sure to disconnect the power cord from the power outlet, and the cables from the connected de­vices.
UNPLUG THE POWER CORD DURING A LONG ABSENCE
Turn off the MAIN power switch and unplug the power cord during a long absence.
2When the remaining length of the paper is about10"
(25cm), a color belt appears at the paper end. Prepare for replacement of the paper. If the remaining paper length is less than 10" (25cm), printing becomes uneven due to the uneven paper core surface.
2When the Printed paper is touched by wet hand,
the print may be discolored.
2When the paper runs out during printing, the printing
operation stops and "EP" is displayed by the indicator on the front panel. Install new paper at this time.
2Store the printed paper in a place with low humidity
free from a direct sunlight.
2If the paper absorbs nonvolatile organic solvents
(alcohol, ester, ketone, etc.) the print may be discolored. Particularly, if the paper comes in contact with soft vinyl chloride such as a transparent tape, it quickens
discoloration. 2Do not use paper other than the specified one. 2Immediately after the paper is replaced, 2-3 images
may be printed with a blank part due to hand's dust
or oil. 2Avoid a direct sunlight or a place near a heater,
and store the paper in a place with 30°C ( 86°F)
or lower temperature and 35-80% RH.
2When the paper is rapidly transferred from a cool
place to a hot place, a vapor or a dew is generated on the paper surface causing paper jam or degraded printing quality.
2A finger print or dust on the paper surface may
degrade the printing quality.
Note:
Mitsubishi brand thermal paper is specially treated with an antistatic coating against thermal head damage caused by static-electricity discharge. The use of non-treated paper may cause premature head failure in your product.
3
SAFETY TECHNICAL CHECKS
Periods: According to the recommendations of the manufacturer of medical device. Scope: a) Visual check
Housing, cables, operator controls, readout device ( displays, LED etc.), labels, accessories, instruction manual.
b) Function test
Performance check acc. instruction manual, also unity and applicability of set and accessory test.
c) Electrical check
Safety electrical test of the configuration in accordance with EN60601-1.
“ In the interest of safety, avoid the handling of liquids beside the set.”
RESPONSIBILITY OF THE MANUFACTURER
The manufacturer, assembler, installer or importer considers himself responsible for the effects on safety, reliability and performance of the EQUIPMENT only if:
– assembly operations, extensions, readjustments, modifications or repairs are carried out by persons authorized by
him, and – the electrical installation of the relevant room complies with the IEC requirements – the EQUIPMENT is used in accordance with the instructions for use.
• Any service after expiration of the warranty period will be made at cost. Consult our service station in your place.
TECHNICAL DESCRIPTION
The supplier will make available on request such circuit diagrams, component part lists, descriptions, calibration
instructions or other information which will assist the USER's appropriately qualified technical personnel to repair
those parts of the EQUIPMENT which are classified by the manufacturer as repairable.
The use of ACCESSORY equipment not complying with the equivalent safety requirements of this equipment may
lead to a reduced level of safety of the resulting system. Consideration relating to the choice shall include:
– use of the accessory in the PATIENT VICINITY
– evidence that the safety certification of the ACCESSORY has been performed in accordance to the appropriate
EN60601-1 and/or EN60601-1-1 harmonized national standard.
The transportation and storage environmental conditions are:
Temperature : -20°C - +60°C (-4°F - +140°F) Humidity : 90%RH or less at 40°C (104°F) Note : The above transportation environmental conditions indicate the storage environmental conditions during transport.
4
UNPACKING
F U
N C
D O W
N
S E T
U P
G A M M
A
F E E D
COPY
3
Take the unit out of the box by the following procedures. Make sure to check the contents.
11
1
Open the top of the box.
11
33
3
Take the unit out of the box carefully.
33
• Make sure to keep the unit horizontal.
22
Remove
2
22
the cushion above the unit.
44
4 Unwrap the unit.
44
Accessories
Thermal paper
AC power cord
Cleaning paper Operation manual Printer driver (1 floppy disk)
5
Loading...
+ 17 hidden pages