1. Indication of capacity has been changed.(BTU base ➔kW base)
2. Control method between indoor and outdoor has been changed.
3. Power supply method has been changed (change to supply from outdoor unit).
4. Power supply cord has been removed.
5. Indoor electronic control P.C. board has been changed.
6. Position of terminal block has been changed.
7. Indoor fan motor has been changed. ( AC ➔ DC)
8. Indoor heat exchanger has been changed.
9. The horizontal vane motor unit has been changed.
An external gear is added to the generalized
stepping motor.
The unit is structured so that the driving torque and
stopping torque would increase.
10. Air cleaning filer has been removed (available as an optional part).
11. Signal of remote controller has been changed. ( It is not available for the conventional models.)
12. Symbol on terminal block has been changed (to S1/S2/S3).
TECHNICAL CHANGES
E1E1
E1E1
E1E1
NOTE:
Do not remove the vane motor
from the motor unit.
Do not disassemble the horizontal
vane motor unit.
1. The operation of thermo-off-unit has been changed. (When 2 or more indoor units are connected with a multi type outdoor
unit, and operated in heat mode.)
E2E1
<,> Indoor fan operates with very Low speed or stops.
E3
<> Indoor fan operates intermittently with very Low speed or stops.
MSZ-GA25VA-➔MSZ-GA25VA-
1. Indoor fan speed has been changed.
E2E1
E2E1
E2E1
E3E2
E3E2
E3E2
E3E2
2
2
Line flow fan
Air outlet
Vertical vane
Air inlet
Display section
Front panel
Panel
Heat exchanger
Horizontal vane
Operation section
(When the front panel is opened)
Remote controller
Remote control
receiving section
Catechin air filter
Air cleaning filter
(Optional parts,AntiAllergy Enzyme Filter,
Blue bellows type)
Emergency operation switch
Fan guard
Operation Indicator
lamp
PART NAMES AND FUNCTIONS
MSZ-GA22VA
MSZ-GA25VA
MSZ-GA35VA
3
1
2
3
4
5
6
7
Installation plate
Installation plate fixing screw 4 o 25 mm
Remote controller holder
Fixing screw for 3 3.5 o 1.6 mm (Black)
Battery (AAA) for remote controller
Wireless remote controller
Felt tape (Used for left or left-rear piping)
1
5
1
2
2
1
1
MSZ-GA22VA
ON-TIMER button
CLOCK SET button
TIME SET buttons
FORWARD button
BACKWARD button
OFF-TIMER button
(This diagram shows an overall view.)
Open the front lid.
RESET button
VANE CONTROL button
Signal transmitting section
Operation display section
Temperature buttons
OPERATE/STOP
(ON/OFF) button
FAN SPEED CONTROL button
OPERATION SELECT button
ECONO COOL button
Indication of
remote controller
model is on back
MSZ-GA25VA
MSZ-GA35VA
ACCESSORIES
REMOTE CONTROLLER
4
3
T3.15AL 250V
MSBPC20M16 12V DC 250" (at 25˚C)
ERZV14D471
3P
INDOOR UNIT
Item
Fuse
Horizontal vane motor
Varistor
Terminal block
(F11)
(MV)
(NR11)
(TB)
MSZ-GA25VA MSZ-GA22VA MSZ-GA35VA
Indoor model
Function
Power supply
1
Single phase
230V,50Hz
630/504
384/258
10
0.25
33
57
0.25
RC0J30-CC
780O298O210
9
4
43
36/29/21
1,250/1,040
830/620
4
KM05B
Single phase
230V,50Hz
10
0.25
33
57
0.25
RC0J30-CC
780O298O210
9
4
43
36/29/21
4
KM05B
43
36/29/21
1,100
43
36/29/22
Cooling
600/480
366/234
1,200/1,000
800/580
2
486/408
336/258
1,010/880
750/620
Cooling
600/480
366/234
1,200/1,000
800/580
Heating
630/504
384/258
1,250/1,040
830/620
Single phase
230V,50Hz
10
0.25
33
57
0.25
RC0J30-CC
780O298O210
9
4
43
36/29/22
4
KM05B
Cooling
600/480
366/246
1,200/1,000
800/600
Heating
630/504
384/270
1,250/1,040
830/640
Air flow(Super High/High)
Air flow(Med./Low)
Power outlet
Running current ✽1
Power input ✽1
Power factor ✽1
Fan motor current ✽1
Model
Dimensions WOHOD
Weight
Air direction
Sound level(Super High)
Sound level(High/Med./Low)
Fan speed(Super High/High)
Fan speed(Med./Low)
Fan speed regulator
Remote controller model
K /h
A
A
W
%
A
mm
kg
dB(A)
dB(A)
rpm
Electrical
data
Fan motor
Special
remarks
Capacity
MSZ-GA25VA MSZ-GA22VA MSZ-GA35VA
Indoor model
Function
Cooling
528
432/336/234
930/760/580
Heating
540
420/366/258
900/800/620
Cooling
528
432/336/234
930/760/580
Heating
540
420/366/258
900/800/620
Cooling
582
468/354/246
1,200
1,000/800/600
Heating
618
504/390/270
1,230
1,040/850/640
Air flow(Super High)
Air flow(High/Med./Low)
Sound level(Super High)
Sound level(High/Med./Low)
Fan speed(Super High)
Fan speed(High/Med./Low)
K /h
K /h
dB(A)
dB(A)
rpm
rpm
Special
remarks
Capacity
43
36/29/21
1,100
Heating
1 :
E1 , E2 (serial number : ~ 6024700)
2 :
E2 (serial number : 6024701 ~) , E3
SPECIFICATION
When outdoor unit is MXZ-8A140VA
NOTE : Test conditions are based on ISO 5151
Specifications and rating conditions of main electric parts
Cooling : IndoorDry-bulb temperature 27:Wet-bulb temperature 19:
Heating : IndoorDry-bulb temperature 20:Wet-bulb temperature 15:
Refrigerant piping length (one way): 5m
✽1 Measured under rated operating frequency.
Outdoor Dry-bulb temperature 35:Wet-bulb temperature 24:
Outdoor Dry-bulb temperature 7:Wet-bulb temperature 6:
1.
5
4
90
80
70
60
50
40
30
20
10
63125250500100020004000 8000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
Test conditions
Cooling : Dry-bulb temperature 27: Wet-bulb temperature 19:
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
COOLING
FUNCTION
43
43
SPL(dB(A))
LINE
Super High
FAN SPEED
HEATING
Heating : Dry-bulb temperature 20: Wet-bulb temperature 15:
INDOOR UNIT
WALL
MICROPHONE
0.8m
1m
90
80
70
60
50
40
30
20
10
6312525050010002000 40008000
NC-60
NC-50
NC-40
NC-30
NC-20
NC-70
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
BAND CENTER FREQUENCIES, Hz
Test conditions
Cooling : Dry-bulb temperature 27: Wet-bulb temperature 19:
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
COOLING
FUNCTION
43
43
SPL(dB(A))
LINE
Super High
FAN SPEED
HEATING
Heating : Dry-bulb temperature 20: Wet-bulb temperature 15:
NOISE CRITERIA CURVES
MSZ-GA22VA
MSZ-GA25VA
MSZ-GA35VA
6
5
155155
335320
41.5215
42.5
214
3
287.5
7055
5555225225
or more7
100
90
106
298
102624.5
780
2105
53.5
19
159
58
14273.5
234
Air in
Air out
Wall hole [65
Indoor unit
Installation plate
Installation plate
11X20 Oblong hole
11X26 Oblong hole
10 or more
75 or more
66 or more
W
75 or more
W
In case of left, left back, or
left under piping (using spacer),
115 or more
Insulation [28
Drain hose [16
(Connected part O.D)
Liquid line [6.35-0.5m
Gas line [9.52-0.43m
Insulation [35 O.D
[19 I.D
{
Required space (Indoor unit)
OUTLINES AND DIMENSIONS
MSZ-GA22VA
MSZ-GA25VA
MSZ-GA35VA
Unit : mm
7
6
Indoor
heat
exchanger
Flared connection
Room temperature
thermistor
RT11
Indoor coil
thermistor
RT13(sub)
Flared connection
Refrigerant flow in cooling
Refrigerant flow in heating
Refrigerant pipe [9.52
(with heat insulator)
Refrigerant pipe [6.35
(with heat insulator)
Indoor coil
thermistor
RT12(main)
SYMBOL
DB111
F11
MF
MV
NR11
SYMBOL
RT11
RT12
RT13
T111
TB
NAME
DIODE STACK
FUSE (T3.15AL250V)
INDOOR FAN MOTOR
VANE MOTOR (HORIZONTAL)
VARISTOR
NAME
ROOM TEMPERATURE THERMIST OR
INDOOR COIL THERMISTOR (MAIN)
INDOOR COIL THERMISTOR (SUB)
TRANSFORMER
TERMINAL BLOCK
4
3
2
1
S2
POWER MONITOR
RECEIVER P.C.BOARD
2
6
230V~
BLU
INDOOR ELECTRONIC
CONTROL P.C. BOARD
SW P.C.
BOARD
INTERLOCK
SWITCH(FAN)
5
MV
TO OUTDOOR
UNIT
CONNECTING
BLK
RED
S3
TB
TAB3
DB111
NR11
F11
5
6
4
2
2
LD
105(T)
LD
101(A)
12-24V
RT13
1R1
CN
GRN
LD104
CN201
2
1
151
CN
T111
RED
WHT
111
CN
CN
112
CN211
BLU
YLW
BLK
MF
RT11
RT12
1
3
5
S1
WIRING DIAGRAM
MSZ-GA22VA
MSZ-GA25VA
MSZ-GA35VA
NOTE:1. About the outdoor side electric wiring refer to the outdoor unit electric wiring diagram for servicing.
For service, set time can be shortened by short circuit of JPG and JPS the electronic control P.C. board.
The time will be shortened as follows. (Refer to 9-7.)
Set time : 1-minute ➔ 1-second
Set time : 3-minute ➔ 3-second (It takes 3 minutes for the compressor to start operation. However, the starting time is
shortened by short circuit of JPG and JPS.)
8-2. P.C. BOARD MODIFICATION FOR INDIVIDUAL OPERATION
A maximum of 4 indoor units with wireless remote controllers can be used in a room.
In this case, to operate each indoor unit individually by each remote controller, P.C. boards of remote controller must be
modified according to the number of the indoor unit.
How to modify the remote controller P.C. board
Remove batteries before modification.
The board has a print as shown below :
NOTE : For modification, take out
the batteries and press the
OPERATE/STOP(ON/OFF)
button twice or 3 times at
first.
After finish modification,
put back the batteries then
press the RESET button.
J1
The P.C. board has the print “J1” and “J2”. Solder “J1” and “J2” according to the number of indoor unit as shown in Table 1.
After modification, press the RESET button.
J2
Table 1
How to set the remote controller exclusively for particular indoor unit
After you turn the breaker ON, the first remote controller that sends the signal to the indoor unit will be regarded as the remote
controller for the indoor unit.
The indoor unit will only accept the signal from the remote controller that has been assigned to the indoor unit once they are
set.
The setting will be cancelled if the breaker has turned off, or the power supply has shut down.
Please conduct the above setting once again after the power has restored.
9
Housing point
JR07
CN151CN211CN112CN1R1
BZ
8-3. AUTO RESTART FUNCTION
When the indoor unit is controlled with the remote controller, the operation mode, the set temperature, and the fan speed
are memorized by the indoor electronic control P.C. board. The “AUTO RESTART FUNCTION” sets to work the moment
power has restored after power failure. Then, the unit will restart automatically.
Operation
1
If the main power has been cut, the operation settings remain.
2 After the power is restored, the unit restarts automatically according to the memory.
(However, it takes at least 3 minutes for the compressor to start running.)
How to release “AUTO RESTART FUNCTION”
1
Turn OFF the main power for the unit.
2Solder the Jumper wire to JR07 on the indoor electronic control P.C. board. (Refer to 9-7.)
NOTE:
•The operation settings are memorized when 10 seconds have passed after the indoor unit was operated with the
remote controller.
•If main power is turned OFF or a power failure occurs while AUTO START/STOP timer is active, the timer setting is
cancelled.
•If the unit has been off with the remote controller before power failure, the auto restart function does not work as the
power button of the remote controller is off.
•To prevent breaker off due to the rush of starting current, systematize other home appliance not to turn ON at the
same time.
•When some air conditioners are connected to the same supply system, if they are operated before power failure,
the starting current of all the compressors may flow simultaneously at restart.
Therefore, the special counter-measures are required to prevent the main voltage-drop or the rush of the starting
current by adding to the system that allows the units to start one by one.
9
TROUBLESHOOTING
MSZ-GA22VAMSZ-GA25VAMSZ-GA35VA
9-1. Cautions on troubleshooting
1. Before troubleshooting, check the following
1) Check the power supply voltage.
2) Check the indoor/outdoor connecting wire for mis-wiring.
2. Take care of the following during servicing
1) Before servicing the air conditioner, be sure to turn OFF the main unit first with the remote controller, and then after
confirming the horizontal vane is closed, turn OFF the breaker and / or disconnect the power plug.
2) Be sure to turn OFF the power supply before removing the front panel, the cabinet, the top panel, and the
electronic control P.C. board.
3) When removing the electronic control P.C. board, hold the edge of the board with care NOT to apply stress on the
components.
4) When connecting or disconnecting the connectors, hold the housing of the connector. DO NOT pull the lead wires.
Lead wiring
10
3. Troubleshooting procedure
RESET button
Insert the negative pole of the
batteries first. Check if the polarity
of the batteries is correct.
OPERATION INDICATOR
Not lighted
Blinking
Lighted
1) First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate an abnormality.
To make sure, check how many times the abnormality indication is flashing on and off before starting service work.
2) Before servicing, check that the connector and terminal are connected properly.
3) If the electronic control P.C. board is supposed to be defective, check the copper foil pattern for disconnection and the
components for bursting and discoloration.
4) When troubleshooting, refer to 9-2., 9-3. and 9-4.
4. How to replace batteries
Weak batteries may cause the remote controller malfunction.
In this case, replace the batteries to operate the remote controller normally.
1 Remove the front lid and insert batteries.
Then reattach the front lid.
2 Press RESET button with tip end of ball point pen
or the like, and then use the remote controller.
NOTE : 1. If RESET button is not pressed, the remote controller may not operate correctly.
2. This remote controller has a circuit to automatically reset the microcomputer when batteries are replaced.
This function is equipped to prevent the microcomputer from malfunctioning due to the voltage drop caused by
the battery replacement.
5. How to install the horizontal vane
If horizontal vane is not installed correctly, all of the operation indicator lamps will blink.
In this case, install the horizontal vane correctly by following the procedures 1 to 2.
NOTE: Before installation of the horizontal vane, turn OFF the power supply.
Stopper
21
Left
In procedure
stoppers until they click
into place.
Lock.
Insert this end first.
INFORMATION FOR MULTI SYSTEM AIR CONDITIONER
OUTDOOR UNIT : MXZ series
Multi system air conditioner can connect two or more indoor units with one outdoor unit.
•Unit won’t operate in case the total capacity of indoor units exceeds the capacity of outdoor units. Do not
connect indoor units beyond the outdoor unit capacity.
Operation indicator lamp flashes as shown in the figure below.
•When you try to operate two or more indoor units with one outdoor unit simultaneously, one for the cooling and
the other for heating, the operation mode of the indoor unit that operates earlier is selected. The other indoor
units cannot operate, indicating as shown in the figure below. In this case, please set all the indoor units to
the same operation mode.
22
lock the
•When indoor units starts the operation while the defrosting of outdoor unit is being done, it takes a few minutes
(max. 10 minutes) to blow out the warm air.
•In the heating operation, though indoor unit that does not operate may get warm or the sound of refrigerant
flowing may be heard, they are not malfunction. The reason is that the refrigerant continuously flows into it.