Mitsubishi Electric NZ2EX2B-60AD4, NZ2GF2BN-60AD4 User Manual

CC-Link IE Field Network Analog-Digital Converter Module User's Manual
-NZ2GF2BN-60AD4
-NZ2EX2B-60AD4

SAFETY PRECAUTIONS

(Read these precautions before using this product.)
In this manual, the safety precautions are classified into two levels: " WARNING" and " CAUTION".
WARNING
CAUTION
Under some circumstances, failure to observe the precautions given under " CAUTION" may lead to
serious consequences. Observe the precautions of both levels because they are important for personal and system safety.
Make sure that the end users read this manual and then keep the manual in a safe place for future reference.
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in minor or moderate injury or property damage.
[Design Precautions]
WARNING
When a communication failure occurs in the network, data in the master module are held. Check Data link status (each station) (SW00B0 to SW00B7) and configure an interlock circuit in the program to ensure that the entire system will operate safely.
Do not use any "use prohibited" signals as a remote input or output signal. Do not write any data to the "use prohibited" areas in the remote register. If these operations are performed, correct operation of the module cannot be guaranteed.
[Design Precautions]
CAUTION
Do not install the control lines or communication cables together with the main circuit lines or power cables. Keep a distance of 100mm or more between them. Failure to do so may result in malfunction due to noise.
1
[Installation Precautions]
WARNING
Shut off the external power supply (all phases) used in the system before mounting or removing a module. Failure to do so may result in electric shock or cause the module to fail or malfunction.
[Installation Precautions]
CAUTION
Use the module in an environment that meets the general specifications in this manual. Failure to do so may result in electric shock, fire, malfunction, or damage to or deterioration of the product.
Do not directly touch any conductive parts and electronic components of the module. Doing so can cause malfunction or failure of the module.
After the first use of the product, do not connect/remove the extension module more than 50 times (IEC 61131-2 compliant). Exceeding the limit may cause malfunction.
To connect an extension module to a main module, engage the respective connectors and securely lock the module joint levers. Incorrect connection may cause malfunction, failure, or drop of the module.
Securely connect the cable connectors. Poor contact may cause malfunction.
2
[Wiring Precautions]
WARNING
Shut off the external power supply (all phases) used in the system before wiring. Failure to do so may result in electric shock or cause the module to fail or malfunction.
[Wiring Precautions]
CAUTION
Individually ground the FG terminal of the programmable controller with a ground resistance of 100 ohms or less. Failure to do so may result in electric shock or malfunction.
Tighten any unused terminal screws within the specified torque range. Undertightening can cause a short circuit due to contact with a solderless terminal.
Use applicable solderless terminals and tighten them within the specified torque range. If any spade solderless terminal is used, it may be disconnected when a terminal block screw comes loose, resulting in failure.
Check the rated voltage and terminal layout before wiring to the module, and connect the cables correctly. Connecting a power supply with a different voltage rating or incorrect wiring may cause a fire or failure.
Tighten the terminal block screws within the specified torque range. Undertightening can cause short circuit, fire, or malfunction. Overtightening can damage the screw and/or module, resulting in drop, short circuit, fire, or malfunction.
Prevent foreign matter such as dust or wire chips from entering the module. Such foreign matter can cause a fire, failure, or malfunction.
Place the cables in a duct or clamp them. If not, dangling cable may swing or inadvertently be pulled, resulting in damage to the module or cables or malfunction due to poor contact.
Do not install the control lines or communication cables together with the main circuit lines or power cables. Keep a distance of 100mm or more between them. Failure to do so may result in malfunction due to noise.
When disconnecting the cable from the module, do not pull the cable by the cable part. For the cable with connector, hold the connector part of the cable. For the cable connected to the terminal block, loosen the terminal screw. Pulling the cable connected to the module may result in malfunction or damage to the module or cable.
When an overcurrent caused by an error of an external device or a failure of the programmable controller flows for a long time, it may cause smoke and fire. To prevent this, configure an external safety circuit, such as a fuse.
Mitsubishi Electric programmable controllers must be installed in control panels. Wiring and replacement of a module must be performed by qualified maintenance personnel with knowledge of protection against electric shock. For wiring methods, refer to "INSTALLATION AND WIRING" in this manual.
3
[Startup and Maintenance Precautions]
WARNING
Do not touch any terminal while power is on. Doing so will cause electric shock or malfunction.
Shut off the external power supply (all phases) used in the system before cleaning the module or
retightening the terminal block screws or connector screws. Failure to do so may cause the module to fail or malfunction.
[Startup and Maintenance Precautions]
CAUTION
Do not disassemble or modify the module. Doing so may cause failure, malfunction, injury, or a fire.
Do not drop or apply strong shock to the module. Doing so may damage the module.
Shut off the external power supply (all phases) used in the system before mounting or removing a
module. Failure to do so may cause the module to fail or malfunction.
After the first use of the product, do not connect/remove the terminal block more than 50 times (IEC 61131-2 compliant). Exceeding the limit may cause malfunction.
Before handling the module or connection cables, touch a conducting object such as a grounded metal to discharge the static electricity from the human body. Failure to do so may cause the module to fail or malfunction.
Startup and maintenance of a control panel must be performed by qualified maintenance personnel with knowledge of protection against electric shock. Lock the control panel so that only qualified maintenance personnel can operate it.
[Disposal Precautions]
CAUTION
When disposing of this product, treat it as industrial waste.
4

CONDITIONS OF USE FOR THE PRODUCT

i) where any problem, fault or failure occurring in the PRODUCT, if any, shall not lead to any major or serious accident;
and
ii) where the backup and fail-safe function are systematically or automatically provided outside of the PRODUCT for the
case of any problem, fault or failure occurring in the PRODUCT.
MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY (INCLUDING, BUT NOT LIMITED TO ANY AND ALL
RESPONSIBILITY OR LIABILITY BASED ON CONTRACT, WARRANTY, TORT, PRODUCT LIABILITY) FOR ANY
INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE
OPERATED OR USED IN APPLICATION NOT INTENDED OR EXCLUDED BY INSTRUCTIONS, PRECAUTIONS, OR
WARNING CONTAINED IN MITSUBISHI'S USER, INSTRUCTION AND/OR SAFETY MANUALS, TECHNICAL
BULLETINS AND GUIDELINES FOR the PRODUCT.
("Prohibited Application")
Prohibited Applications include, but not limited to, the use of the PRODUCT in;
• Nuclear Power Plants and any other power plants operated by Power companies, and/or any other cases in which the
public could be affected if any problem or fault occurs in the PRODUCT.
• Railway companies or Public service purposes, and/or any other cases in which establishment of a special quality
assurance system is required by the Purchaser or End User.
• Aircraft or Aerospace, Medical applications, Train equipment, transport equipment such as Elevator and Escalator,
Incineration and Fuel devices, Vehicles, Manned transportation, Equipment for Recreation and Amusement, and
Safety devices, handling of Nuclear or Hazardous Materials or Chemicals, Mining and Drilling, and/or other
applications where there is a significant risk of injury to the public or property.
Notwithstanding the above, restrictions Mitsubishi may in its sole discretion, authorize use of the PRODUCT in one or
more of the Prohibited Applications, provided that the usage of the PRODUCT is limited only for the specific
applications agreed to by Mitsubishi and provided further that no special quality assurance or fail-safe, redundant or
other safety features which exceed the general specifications of the PRODUCTs are required. For details, please
contact the Mitsubishi representative in your region.
5

INTRODUCTION

Remark
Thank you for purchasing the CC-Link IE Field Network analog-digital converter module (hereafter abbreviated as A/D
converter module).
This manual describes the operating procedure, system configuration, parameter settings, functions, and
troubleshooting of the A/D converter module.
Before using this product, please read this manual and the relevant manuals carefully and develop familiarity with the
functions and performance of the A/D converter module to handle the product correctly.
When applying the program examples introduced in this manual to an actual system, ensure the applicability and
confirm that it will not cause system control problems.
Relevant modules: NZ2GF2BN-60AD4, NZ2EX2B-60AD4
Unless otherwise specified, this manual describes the program examples in which the remote I/O signals and remote registers are assigned for an A/D converter module as follows.
• Remote input signal: RX0 to RX1F (main A/D converter module), RX20 to RX2F (extension A/D converter module)
• Remote output signal: RY0 to RY1F (main A/D converter module), RY20 to RY2F (extension A/D converter module)
• Remote register (RWr): RWr0 to RWrF (main A/D converter module), RWr10 to RWr1F (extension A/D converter module)
• Remote register (RWw): RWw0 to RWwF (main A/D converter module), RWw10 to RWw1F (extension A/D converter module)
For the assignment of remote I/O signals and remote registers, refer to the following. User's manual for the master/local module used
6

RELEVANT MANUALS

(1) CC-Link IE Field Network (relevant) manuals
When using the CC-Link IE Field Network for the first time, refer to CC-Link IE Field Network Master/Local
Module User's Manual or Simple Motion Module User's Manual first. The following shows the structure of the CC-
Link IE Field Network manuals.
Manual name
<manual number (model code)>
MELSEC-Q CC-Link IE Field Network Master/Local Module User's Manual [SH-080917ENG, 13JZ47]
MELSEC-L CC-Link IE Field Network Master/Local Module User's Manual [SH-080972ENG, 13JZ54]
MELSEC iQ-R Ethernet/CC-Link IE User's Manual (Startup) [SH-081256ENG, 13JX09]
MELSEC iQ-R CC-Link IE Field Network User's Manual (Application) [SH-081259ENG, 13JX18]
MELSEC iQ-R Inter-Module Synchronization Function Reference Manual [SH-081401ENG]
MELSEC-Q QD77GF Simple Motion Module User's Manual (Network) [IB-0300203, 1XB957]
MELSEC-Q QD77GF Simple Motion Module User's Manual (Positioning Control) [IB-0300202, 1XB956]
CC-Link IE Field Network Remote I/O Module User's Manual [SH-081114ENG, 13JZ82]
CC-Link IE Field Network Digital-Analog Converter Module User's Manual [SH-081453ENG, 13JX27]
Description
Overview of the CC-Link IE Field Network, and specifications, procedures before operation, system configuration, installation, wiring, settings, functions, programming, and troubleshooting of the QJ71GF11-T2
Overview of the CC-Link IE Field Network, and specifications, procedures before operation, system configuration, installation, wiring, settings, functions, programming, and troubleshooting of the LJ71GF11-T2
Specifications, procedures before operation, system configuration, wiring, and communication examples of Ethernet, CC-Link IE Controller Network, and CC-Link IE Field Network
Functions, parameter settings, programming, troubleshooting, I/O signals, and buffer memory of CC-Link IE Field Network
Inter-module synchronization function, which controls multiple modules synchronously
Functions, programming, and troubleshooting for CC-Link IE Field Network of the QD77GF16
Specifications of the QD77GF16 and information on how to establish a system, maintenance and inspection, and troubleshooting. Also included are functions, programming and buffer memory for the positioning control of the QD77GF16.
Specifications, procedures before operation, system configuration, installation, wiring, various settings, functions, programming, and troubleshooting of the CC-Link IE Field Network remote I/O module
Specifications, procedures before operation, system configuration, installation, wiring, various settings, functions, programming, and troubleshooting of the CC-Link IE Field Network digital-analog converter module
(2) Operating manual
Manual name
<manual number (model code)>
GX Works2 Version 1 Operating Manual (Common) [SH-080779ENG, 13JU63]
GX Works3 Operating Manual [SH-081215ENG]
Description
System configuration, parameter settings, and online operations of GX Works2, which are common to Simple projects and Structured projects
System configuration, parameter settings, and online operations of GX Works3
7

CONTENTS

CONTENTS
SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
CONDITIONS OF USE FOR THE PRODUCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
RELEVANT MANUALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
MANUAL PAGE ORGANIZATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
TERMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
PACKING LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
CHAPTER 1 A/D CONVERTER MODULE 15
1.1 Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
CHAPTER 2 PART NAMES 20
2.1 Main A/D Converter Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2.2 Extension A/D Converter Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
CHAPTER 3 SPECIFICATIONS 24
3.1 General Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3.2 Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.2.1 Main A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
3.2.2 Extension A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
3.3 How to Calculate Current Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.4 Function List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
3.5 List of Remote I/O Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
3.5.1 Main A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
3.5.2 Extension A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
3.6 List of Remote Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
3.6.1 Main A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
3.6.2 Extension A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
3.7 List of Remote Buffer Memory Areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
3.7.1 Main A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
3.7.2 Extension A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
CHAPTER 4 PROCEDURES BEFORE OPERATION 46
CHAPTER 5 SYSTEM CONFIGURATION 48
5.1 System Configuration with A/D Converter Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
5.2 Applicable Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
CHAPTER 6 INSTALLATION AND WIRING 50
6.1 Station Number Setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
6.2 Installation Environment and Installation Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
6.2.1 Installation environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
6.2.2 Installation position. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
8
6.2.3 Installation direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
6.3 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
6.3.1 How to connect an extension module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
6.3.2 How to mount modules on a DIN rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
6.4 Wiring to Terminal Block for Module Power Supply and FG. . . . . . . . . . . . . . . . . . . . . . . . . . . 58
6.5 Wiring of Ethernet Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
6.6 Wiring of Terminal Block and External Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
CHAPTER 7 VARIOUS SETTINGS 69
7.1 Parameter Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
7.2 How to Change the Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
7.2.1 Changing the network configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76
7.2.2 Changing the parameters without changing the network configuration . . . . . . . . . . . . . . . . . .80
7.3 Offset/Gain Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
CHAPTER 8 FUNCTIONS 85
8.1 Mode Shift at Power-On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
8.2 Drive Mode Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
8.3 Each Function in the Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
8.4 A/D Conversion Enable/Disable Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
8.5 Conversion Speed Switch Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
8.5.1 Conversion speed and sampling period. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
8.6 A/D Conversion Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
8.7 Range Switching Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8.8 Maximum Value/Minimum Value Hold Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
8.9 Input Signal Error Detection Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
8.10 Alert Output Function (Process Alarm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
8.11 Scaling Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
8.12 Shift Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
8.13 Digital Clipping Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
8.14 Difference Conversion Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
8.15 Trigger Conversion Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
8.16 CC-Link IE Field Network Synchronous Communication Function. . . . . . . . . . . . . . . . . . . . . 135
8.17 Error Notification Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
8.18 Functions with an Extension Module Connected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
8.18.1 Functions with an extension I/O module connected. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
8.18.2 Functions with the extension A/D converter module connected. . . . . . . . . . . . . . . . . . . . . . .150
8.18.3 Functions with the extension D/A converter module connected. . . . . . . . . . . . . . . . . . . . . . .151
8.19 CC-Link IE Field Network Diagnostic Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
CHAPTER 9 PROGRAMMING 155
9.1 Precautions for Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
9.2 Programming Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156
9.3 Program Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
9
CHAPTER 10 MAINTENANCE AND INSPECTION 166
CHAPTER 11 TROUBLESHOOTING 168
11.1 How to Check Error Codes and Alarm Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
11.2 Error Code List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
11.2.1 Main A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .173
11.2.2 Extension A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178
11.3 Alarm Code List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
11.3.1 Main A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180
11.3.2 Extension A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180
11.4 Checking the LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
11.4.1 Main A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181
11.4.2 Extension A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184
11.5 Unit Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
11.6 Troubleshooting by Symptom . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
11.6.1 Main A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186
11.6.2 Extension A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .188
APPENDICES 189
Appendix 1 Details of Remote I/O Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
Appendix 1.1 Remote input signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189
Appendix 1.2 Remote output signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198
Appendix 2 Details of Remote Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
Appendix 3 Details of Remote Buffer Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Appendix 4 I/O Conversion Characteristics of A/D Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
Appendix 5 Accuracy of A/D Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
Appendix 6 Processing Time of CC-Link IE Field Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
Appendix 7 EMC and Low Voltage Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
Appendix 7.1 Measures to comply with the EMC Directive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234
Appendix 7.2 Requirements to compliance with the Low Voltage Directive . . . . . . . . . . . . . . . . . .240
Appendix 8 How to Check Serial Number and Function Version . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
Appendix 9 Comparison with NZ2GF2B-60AD4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
Appendix 9.1 Comparison of performance specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
Appendix 9.2 Functional comparison. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242
Appendix 9.3 About replacement from NZ2GF2B-60AD4 to NZ2GF2BN-60AD4 . . . . . . . . . . . . . .243
Appendix 10 External Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
Appendix 10.1 Main A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244
Appendix 10.2 Extension A/D converter module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244
INDEX 245
REVISIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
TRADEMARKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
10

MANUAL PAGE ORGANIZATION

The section of the current page is shown.
The chapter of the current page is shown.
"" is used for window names and items.
[ ] is used for items in the menu bar and the project window.
shows operating procedures.
shows reference manuals.
shows notes that require attention.
shows mouse operations.
*1
shows reference pages.
shows setting or operating examples.
Ex.
shows useful information.
A window selected in the view selection area is displayed.
View selection area
[Online] [Write to PLC...]
Select [Online] on the menu bar, and then select [Write to PLC...].
Project window
[Parameter]
[PLC Parameter]
Select [Project] from the view selection area to open the Project window.
Menu bar
Ex.
Ex.
In the Project window, expand [Parameter] and select [PLC Parameter].
In this manual, pages are organized and the symbols are used as shown below.
The following illustration is for explanation purpose only, and should not be referred to as an actual documentation.
*1 The mouse operation example is provided below.
11

TERMS

Unless otherwise specified, this manual uses the following terms.
Ter m Description
A/D converter module A generic term for the main A/D converter module and extension A/D converter module
Buffer memory
CC-Link IE Field Network A high-speed and large-capacity open field network that is based on Ethernet (1000BASE-T)
Cyclic transmission
Data link A generic term for cyclic transmission and transient transmission
Dedicated instruction An instruction that simplifies programming for using functions of intelligent function modules
Disconnection A process of stopping data link if a data link error occurs
Extension A/D converter module
Extension analog module A generic term for the extension A/D converter module and extension D/A converter module
Extension D/A converter module
Extension I/O module A generic term for the extension input module and extension output module
Extension input module A generic term for extension modules where digital signals can be input
Extension module
Extension output module A generic term for extension modules where digital signals can be output
GX Works2
GX Works3
I/O module Another term for the CC-Link IE Field Network remote I/O module
Intelligent device station
Link device A device (RX, RY, RWr, or RWw) in a module on CC-Link IE Field Network
Link special register (SW) Word data that indicates the operating status and data link status of a module on CC-Link IE Field Network
Link special relay (SB) Bit data that indicates the operating status and data link status of a module on CC-Link IE Field Network
Local station
Main A/D converter module The abbreviation for the NZ2GF2BN-60AD4 CC-Link IE Field Network main analog-digital converter module
Main analog module A generic term for the main A/D converter module and main D/A converter module
Main D/A converter module The abbreviation for the NZ2GF2BN-60DA4 CC-Link IE Field Network main digital-analog converter module
Main module
Master station
Master/local module A generic term for the CC-Link IE Field Network master/local module
Network module
Relay station
REMFR The abbreviation for ZP.REMFR.
Remote buffer memory Buffer memory in a remote device station
Remote device station
Remote I/O station A station that exchanges I/O signals (bit data) with the master station by cyclic transmission
A memory in an intelligent function module, where data (such as setting values and monitoring values) exchanged with a CPU module are stored
A function by which data are periodically exchanged among stations on the same network using link devices (RX, RY, RWw, and RWr)
The abbreviation for the NZ2EX2B-60AD4 CC-Link IE Field Network extension analog-digital converter module
The abbreviation for the NZ2EX2BN-60DA4 CC-Link IE Field Network extension digital-analog converter module
A remote module with no CC-Link IE Field Network communication function. This module cannot be used as a single module. However, connecting the module to the main module will increase the number of I/O points per station.
The product name of the software package for the MELSEC programmable controllers
A station that exchanges I/O signals (bit data) and I/O data (word data) with another station by cyclic transmission. This station responds to a transient transmission request from another station and also issues a transient transmission request to another station.
A station that performs cyclic transmission and transient transmission with the master station and other local stations. The station is controlled by programs in the CPU module or other equivalent modules on the station.
A module with the CC-Link IE Field Network communication function, which can be used as a single remote module.
A station that controls the entire network. This station can perform cyclic transmission and transient transmission with all stations. Only one master station can be used in a network.
A generic term for the following modules:
• CC-Link IE Field Network module
• CC-Link IE Controller Network module
• Ethernet interface module
• MELSECNET/H module
• MELSECNET/10 module
A station that includes two or more network modules. Data are passed through this station to stations on other networks
A station that exchanges I/O signals (bit data) and I/O data (word data) with another station by cyclic transmission. This station responds to a transient transmission request from another station.
12
Ter m Description
Remote input (RX)
Remote output (RY)
Remote register (RWr)
Remote register (RWw)
REMTO The abbreviation for ZP.REMTO.
Reserved station A station reserved for future use. This station is not actually connected, but counted as a connected station
Return A process of restarting data link when a station recovers from an error
Simple motion module The abbreviation for the QD77GF CC-Link IE Field Network simple motion module
Slave station
Transient transmission
Bit data input from a slave station to the master station (For some areas in a local station, data are input in the opposite direction.) User's manual for the master/local module used
Bit data output from the master station to a slave station (For some areas in a local station, data are output in the opposite direction.) User's manual for the master/local module used
Word data input from a slave station to the master station (For some areas in a local station, data are input in the opposite direction.) User's manual for the master/local module used
Word data output from the master station to a slave station (For some areas in a local station, data are output in the opposite direction.) User's manual for the master/local module used
A generic term for stations other than a master station: local station, remote I/O station, remote device station, and intelligent device station
A function of communication with another station, which is used when requested by a dedicated instruction or GX Works2
13

PACKING LIST

The following items are included in the package of this product. Before use, check that all the items are included.
A/D converter module
Module (The figure above shows the main A/D converter module.) Before Using the Product
14

CHAPTER 1 A/D CONVERTER MODULE

Master station
CC-Link IE Field Network
Main A/D converter module
Control valve
Flow control
Tank
CHAPTER 1 A/D CONVERTER MODULE
This chapter describes the application and the features of the A/D converter module.
1.1 Application
The A/D converter module converts analog values that are input from external devices to digital operation values.
A/D conversion
Analog signal as a continuous amount
The converted digital operation value can be checked in the master station.
Using the A/D converter module allows the flow or temperature measured by the A/D converter module to be checked
through the master station.
Digital signal as a discrete sequence
1
Master station

1.1 Application

CC-Link IE Field Network
Power conditioner
Heater
Main A/D converter module
15

1.2 Features

(1) Flexible system configuration
The employed connection block type provides the combined use of a main module and an extension module.
A flexible configuration can be achieved because various extension modules can be connected.
In addition, the main module always monitors the connection status of the extension module, leading to an early
detection of connection failure.
Various extension modules can be connected according to the application. No wiring of wires and Ethernet cables is required.
Extension moduleMain module
Main A/D converter module
The flexible combination is possible.
Extension input module
Extension output module (sink type)
Extension output module (source type)
Extension A/D converter module
Extension D/A converter module
(2) Easy setting of station numbers
Station numbers are set with the rotary switch on the front of the module, where setting and checking the station
numbers are easy.
(3) Selectable conversion speed
A/D conversion at 100μs/channel meets the need of a high-speed conversion.
Under the environment in which noise is likely to occur, switching the conversion speed to 400μs/channel or
1ms/channel minimizes the effect of noise on the digital operation value, the stability of which is improved.
16
CHAPTER 1 A/D CONVERTER MODULE
(4) A/D conversion at any desired timing
A/D conversion is performed once immediately after the input of a trigger conversion request to obtain the digital
operation value.
The combination with the external signal assignment function allows direct input of a trigger conversion request
from the extension input module, with the following advantages:
• Being free from the effect of the sequence scan and link scan, digital operation values can be constantly
obtained at a given timing, which leads to the improvement of the reliability.
• Digital operation values can be obtained without any program, which leads to a reduction in the cost of
creating a program.
Analog input signals (CH1 to CH4)
Displacement sensor
Extension input module
1
Main A/D converter module
Trigger conversion request by the external
signal assignment function
(5) Change to any scale
A/D conversion values can be converted to be within any scale, the range of which is determined arbitrarily.
According to the device that handles digital operation values, the scale can be changed without any program,
resulting in cost reduction.
(6) Detection of the disconnection
An input range of 1 to 5V, or 4 to 20mA allows the detection of the disconnection of analog input, facilitating the
diagnosis of the cause at the time of a trouble.
In combination with the external signal assignment function, the extension output module allows a signal (input
signal error detection signal) to be output to the outside without any program upon detection of the disconnection.
At this time, there is no influence of the sequence scan and link scan.
1.2 Features
17
(7) Input and output without an influence of the sequence scan and link scan
Ex.
Main A/D converter module
Extension output module
An error has
occurred.
An error signal occurred in the A/D converter module can be output to the extension output module directly.
Error lamp
(external device)
Programming is not necessary to turn on an error lamp when an error occurs.
Using the external signal assignment function allows a trigger conversion request to be input from the extension
input module. In the event of an error or an alert, an error status or an alert status can be output from the
extension output module.
These input and output are not affected by the sequence scan and link scan.
To turn on the lamp when an error occurs.
(8) Support for the CC-Link IE Field Network synchronous communication
function
A/D conversion can be performed together with the synchronization period of the master station that supports the
CC-Link IE Field Network synchronous communication function.
This enables the A/D converter module to operate at the same timing of other slave stations sharing the same
network.
18
CHAPTER 1 A/D CONVERTER MODULE
Downward installation
DIN rail
Vertical installation Horizontal installation Horizontal installation
(upside down)
Upward installation
(9) Various installation methods
The module can be installed in six directions using a DIN rail.
1
(10)Easy module replacement
The terminal block for module power supply and FG, and the terminal block for analog input signals have a two-
piece structure, where the module can be replaced with the wire connected. In addition, the terminal block for
analog input signals has a lift-up structure, where the terminal block lifts only by loosening the terminal block
mounting screw, enabling it to be removed easily.
(11)Check on the error history
The history of the last 15 errors and occurrence time is stored in the main A/D converter module.
Checking the error information of the past helps to identify the cause at the time of a trouble.
(12)Easy settings by CC IE Field configuration of the engineering tool
The CC IE Field configuration of the engineering tool makes it possible to set parameters on its window, thereby
reducing the programs. In addition, the setting status and the operating status of modules can be checked easily.
1.2 Features
19

CHAPTER 2 PART NAMES

*1
*1
3)
2)
4) 5) 6)
1)
8)
7)

2.1 Main A/D Converter Module

This section describes part names of the main A/D converter module.
*1 Do not remove this seal because it is used for our maintenance purposes.
No. Name Application
1) Station number setting switch
A rotary switch for the following setting and test.
• Station Number Setting ( Page 50, Section 6.1)
• Offset/Gain Setting ( Page 83, Section 7.3)
• Unit Test ( Page 185, Section 11.5)
When operating the station number setting switch, use a slotted screwdriver with 3.5mm or less width of the tip.
20
No. Name Application
PW LED (green)
RUN LED (green)
MODE LED (green)
D LINK LED (green)
ERR. LED (red)
2)
ALM LED (red)
O/G LED (green)
V LED (green), I LED (green)
CH1 to CH4 LED (green)
OFFSET LED (green), GAIN LED (green)
P1
L ER LED (red)
LINK LED (green)
3)
P2
L ER LED (red)
LINK LED (green)
Terminal block for module
4) power supply and FG
5) DIN rail hook A hook for mounting a module on a DIN rail
Terminal cover Covers for preventing electric shock while the power is on
6)
Terminal block for analog input signals
7) SET/SEL button In offset/gain setting mode, select the set target by pressing button or button.
8) Extension connector cover
Indicates the power supply status of the main A/D converter module.
• On: Power-on
• Off: Power-off
Indicates the operating status of the main A/D converter module.
• On: Operating normally; Writing data to the non-volatile memory (while in offset/gain setting mode)
• Off: Major error occurred
Indicates the mode of the main A/D converter module.
• On: In online mode
• Flashing: In unit test mode
• Off: In offset/gain setting mode
Indicates the data link status of the main A/D converter module.
• On: Data link in operation (cyclic transmission in progress)
• Flashing: Data link in operation (cyclic transmission stopped)
• Off: Data link not performed (disconnected)
Indicates the error status of the main A/D converter module and the extension module.
• On: Moderate error or major error occurred
• Flashing: Warning occurred
• Off: In normal operation
Indicates the alert status of the main A/D converter module and the extension module.
• On: Alert issued
• Flashing: Input signal error detected
• Off: In normal operation
Indicates the module is in offset/gain setting mode.
• On: In offset/gain setting mode
• Off: In a mode other than offset/gain setting mode
Indicates the user range of a set target selected in offset/gain setting mode.
Set target V LED I LED
User range setting 1 (-10 to 10V) On Off
User range setting 2 (-5 to 5V, -20 to 20mA) Off On
Indicates the channel of a set target selected in offset/gain setting mode.
• On: The channel corresponding to the number being on is the set target.
• Off: The channel corresponding to the number being off is not the set target.
Indicates whether the selected setting is offset or gain in the offset/gain setting mode.
Set target OFFSET LED GAIN LED
Offset On Off
Gain Off On
PORT1 connector for the connection to CC-Link IE Field Network (RJ45 connector) Connect an Ethernet cable. ( Page 60, Section 6.5) There are no restrictions on the connection order of the cables for the P1 connector and P2 connector.
• On: Module received abnormal data, or module performing loopback
• Off: Module received normal data, or module not performing loopback
• On: Link-up
• Off: Link-down
PORT2 connector for the connection to CC-Link IE Field Network (RJ45 connector) Connect an Ethernet cable. ( Page 60, Section 6.5) There are no restrictions on the connection order of the cables for the P1 connector and P2 connector.
(same as the LEDs of the P1 connector)
A terminal block for the connection of a module power supply (24VDC) and FG
A two-piece screw terminal block for the connection to an external device
A cover to protect a connector of an extension module. Do not remove the cover if an extension module is not connected to the connector.
CHAPTER 2 PART NAMES
2
2.1 Main A/D Converter Module
21
(1) Module status and LED status
The following table shows how module status and LED status correspond each other.
LED status
Module status Data link status
Disconnecting Disconnection On On On Off Off Off Off
Data link in operation Data link in operation On On On On Off Off Off
Normal mode
Offset/gain setting mode On Off Off Flashing Off
Unit test
Communication error Cyclic stop On On On Flashing Off Off Off
Error
Warning Minor error On On
Alarm
Reserved station specification in progress
Link stop Cyclic stop On On On Flashing Off Off Off
In progress On On Flashing
Completed successfully
Completed with an error
Major error On Off
Moderate error On On
Alert issued On On On
Input signal error occurred
Cyclic stop On On On Flashing Off Off Off
On On Off Off Off Off Off
On On Off Off On Off Off
On On On
PW LED RUN LED
MODE
LED
*2 *1
*2 *1
*2 *1
D LINK
LED
*1
*1 *1
*1 *1
ERR. LED ALM LED O/G LED
*1
Off Off Off
*3 *1
On
On
Flashing
*1
*1
On Off
Flashing Off
On
Off
Off
Off
*1 Either On, Flashing, or Off. *2 Either On or Off. *3 A failure of the module may not allow the LED to turn on.
22
2.2 Extension A/D Converter Module
This section describes part names of the extension A/D converter module.
1)
CHAPTER 2 PART NAMES
2
3) 2) 4)
No. Name Application
Indicates the operating status of the extension A/D converter module.
• On: In normal operation
1) RUN LED (green)
2) DIN rail hook A hook for mounting a module on a DIN rail
Terminal cover Covers for preventing electric shock while the power is on
3) Terminal block for analog input signals A two-piece terminal block for the connection to an external device
4) Terminal block for external power supply and FG A terminal block for the connection of an external power supply (24VDC) and FG
• Flashing: External power supply being off
• Off: Major error occurred; main analog module being in offset/gain setting mode; or main analog module being in unit test mode

2.2 Extension A/D Converter Module

23

CHAPTER 3 SPECIFICATIONS

This chapter describes the specifications of the A/D converter module.

3.1 General Specifications

Item Specifications
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Storage ambient humidity
Vibration resistance
Shock resistance Compliant with JIS B 3502 and IEC 61131-2 (147m/, 3 times each in X, Y, and Z directions)
Operating atmosphere
Operating altitude
Installation location
Overvoltage
*3
category
Pollution degree
Equipment class Class
0 to 55
-25 to 75
5 to 95%RH, non-condensing
Compliant with JIS B 3502 and IEC 61131-2
No corrosive gases
*1
0 to 2000m
Inside a control panel
or less
*4
2 or less
Under intermittent vibration
Under continuous vibration
*2
Frequency
5 to 8.4Hz 3.5mm
8.4 to 150Hz 9.8m/
5 to 8.4Hz 1.75mm
8.4 to 150Hz 4.9m/
Constant acceleration
Half amplitude Number of sweeps
10 times each in X, Y, and Z directions
*1 Do not use or store the A/D converter module under pressure higher than the atmospheric pressure at an altitude of 0
meters. Doing so may cause malfunction. When using the A/D converter module under pressure, please consult your local Mitsubishi representative.
*2 If the environment satisfies the operating ambient temperature, operating ambient humidity and other conditions, the
module can be used even outside the control panel.
*3 This indicates the assumption that the equipment is connected to which type of power distribution system, from the
public electrical power distribution network down to machinery within premises. Category applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for the equipment with up to the rated voltage of 300V is 2500V.
*4 This index indicates the degree to which conductive material is generated in terms of the environment in which the
equipment is used. In pollution degree 2, only non-conductive pollution occurs. A temporary conductivity caused by condensation must be expected occasionally.
For compliance with the EMC Directive, refer to "EMC and Low Voltage Directives" in this manual. ( Page 234, Appendix
7)
24
CHAPTER 3 SPECIFICATIONS
3.2 Performance Specifications

3.2.1 Main A/D converter module

Item Description
Station type Remote device station
Number of analog input points 4 points (4 channels)/module
Analog input
Digital output 16-bit signed binary (-16384 to 16383)
I/O characteristics, maximum
resolution
Conversion
accuracy
Conversion speed
Absolute maximum input
Isolation method
Withstand voltage
Noise immunity Noise voltage 500Vp-p, noise width 1μs, noise frequency 25 to 60Hz (noise simulator condition)
External interface
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable wire size
*1
*2
Voltage -10 to 10VDC (input resistance 1MΩ)
Current 0 to 20mADC (input resistance 250Ω)
Input Input range Digital output value Maximum resolution
-10 to 10V
User range setting 1 (-10 to 10V) 0.5mV
Volt age
Current
Ambient temperature (25±5)
Ambient temperature (0 to 55)
*5
Communication part
Module power supply part
I/O part
For power supply Core: 0.5 to 1.5 (20 to 16 AWG)
For I/O Core: 0.3 to 2.0 (22 to 14 AWG)
±0.1%
±0.2%
100μs/channel 400μs/channel 1ms/channel
Voltage: ±15V, Current: ±30mA
Between communication system terminal and all analog input terminals: Photocoupler isolation Between power supply system terminal and all analog input terminals: Transformer isolation Between input channels: Non-isolation
Between all power supply and communication system terminals and all analog input terminals 500VAC for 1 minute
RJ45 connector
Terminal block for module power supply and FG Tightening torque range for terminal screw (M2.5 screw): 0.5 to 0.6N⋅m
18-point two-piece terminal block (M3 screw) Tightening torque range for terminal screw (M3 screw × 5.2): 0.43 to 0.57N⋅m
User range setting 2 (-5 to 5V) 0.25mV
0 to 5V
1 to 5V 0.25mV
0 to 20mA
4 to 20mA 1μA
User range setting 2 (-20 to 20mA) -16000 to 16000 1μA
-16000 to 16000
0 to 16000
0 to 16000
*3
3
0.625mV
0.3125mV
1.25μA

3.2 Performance Specifications

25
Item Description
TE 0.5-10 (NICHIFU Co., Ltd.) [Applicable wire size: 0.5] TE 0.75-10 (NICHIFU Co., Ltd.) [Applicable wire size: 0.75]
Terminal block for module power
Applicable solderless terminal
Cyclic transmission
Communication cable
Applicability of extension module Connectable (Max. one module)
External power supply
Weight 0.30kg
supply and FG
Terminal block for analog input signals
RX/RY points 32 points + 16 points × Number of extension modules
RWr/RWw points 16 points + Points of each extension module
TE 1.0-10 (NICHIFU Co., Ltd.) [Applicable wire size: 0.9 to 1.0] TE 1.5-10 (NICHIFU Co., Ltd.) [Applicable wire size: 1.25 to 1.5] AI 0.5-10WH (Phoenix Contact Co., Ltd.) [Applicable wire size: 0.5]
*4
AI 0.75-10GY (Phoenix Contact Co., Ltd.) [Applicable wire size: 0.75] AI 1-10RD (Phoenix Contact Co., Ltd.) [Applicable wire size: 1.0] AI 1.5-10BK (Phoenix Contact Co., Ltd.) [Applicable wire size: 1.5]
RAV1.25-3 (compliant with JIS C 2805) [Applicable wire size: 0.3 to 1.25] V2-MS3 (JST Mfg. Co., Ltd) [Applicable wire size: 1.25 to 2.0] RAP2-3SL (Nippon Tanshi Co., Ltd.) [Applicable wire size: 1.25 to 2.0] TGV2-3N (NICHIFU Co., Ltd.) [Applicable wire size: 1.25 to 2.0]
An Ethernet cable that meets the 1000BASE-T standard: Category 5e or higher (double shielded, STP), straight cable
24VDC (20.4 to 28.8VDC) Inrush current: 36.5A, 1ms or lower Current consumption: 210mA
*1 For details on the I/O conversion characteristics, refer to the following:
• I/O Conversion Characteristics of A/D Conversion ( Page 229, Appendix 4)
*2 Except for the conditions under noise influence. *3 This current value is an instantaneous value at which no breakdown occurs in the internal resistance of the module. The
maximum input current value for constant application is 24mA. *4 Do not connect two or more cables to the terminal. *5 The sampling period varies depending on whether an extension analog module is connected or not. For details, refer to
the following:
• Conversion Speed and Sampling Period ( Page 90, Section 8.5.1)
26
CHAPTER 3 SPECIFICATIONS

3.2.2 Extension A/D converter module

Item Description
Number of analog input points 4 points (4 channels)/module
Analog input
Digital output 16-bit signed binary (-16384 to 16383)
I/O characteristics, maximum resolution
Conversion
*2
accuracy
Conversion speed
Absolute maximum input
Isolation method
Withstand voltage
Noise immunity Noise voltage 500Vp-p, noise width 1μs, noise frequency 25 to 60Hz (noise simulator condition)
External interface
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Applicable wire size
Applicable solderless terminal
Cyclic transmission
Module power supply (supplied from a main module)
External power supply
Weight 0.22kg
Voltage -10 to 10VDC (input resistance 1MΩ)
Current 0 to 20mADC (input resistance 250Ω)
Input Input range Digital output value Maximum resolution
-10 to 10V -16000 to 16000 0.625mV
Volt age
*1
Current
Ambient temperature (25±5)
Ambient temperature (0 to 55)
*5
External power supply part
I/O part
For power supply Core: 0.5 to 1.5 (20 to 16 AWG)
For I/O Core: 0.3 to 2.0 (22 to 14 AWG)
Terminal block for external power
supply and FG
Terminal block for analog input signals
RX/RY points 16 points
RWr/RWw points 16 points
Voltage 24VDC (20.4 to 28.8VDC)
Current 90mA
±0.1%
±0.2%
100μs/channel 400μs/channel 1ms/channel
Voltage: ±15V, Current: ±30mA
Between communication system terminal and all analog input terminals: Photocoupler isolation Between power supply system terminal and all analog input terminals: Transformer isolation Between input channels: Non-isolation
Between all power supply and communication system terminals and all analog input terminals 500VDC for 1 minute
Terminal block for external power supply and FG Tightening torque range for terminal screw (M2.5 screw): 0.5 to 0.6N⋅m
18-point two-piece terminal block (M3 screw) Tightening torque range for terminal screw (M3 screw × 5.2): 0.43 to 0.57N⋅m
TE 0.5-10 (NICHIFU Co., Ltd.) [Applicable wire size: 0.5] TE 0.75-10 (NICHIFU Co., Ltd.) [Applicable wire size: 0.75] TE 1.0-10 (NICHIFU Co., Ltd.) [Applicable wire size: 0.9 to 1.0] TE 1.5-10 (NICHIFU Co., Ltd.) [Applicable wire size: 1.25 to 1.5] AI 0.5-10WH (Phoenix Contact Co., Ltd.) [Applicable wire size: 0.5]
*4
AI 0.75-10GY (Phoenix Contact Co., Ltd.) [Applicable wire size: 0.75] AI 1-10RD (Phoenix Contact Co., Ltd.) [Applicable wire size: 1.0] AI 1.5-10BK (Phoenix Contact Co., Ltd.) [Applicable wire size: 1.5]
RAV1.25-3 (compliant with JIS C 2805) [Applicable wire size: 0.3 to 1.25] V2-MS3 (JST Mfg. Co., Ltd) [Applicable wire size: 1.25 to 2.0] RAP2-3SL (Nippon Tanshi Co., Ltd.) [Applicable wire size: 1.25 to 2.0] TGV2-3N (NICHIFU Co., Ltd.) [Applicable wire size: 1.25 to 2.0]
24VDC (20.4 to 28.8VDC) Inrush current: 22.0A, 1ms or lower Current consumption: 45mA
0 to 5V
1 to 5V 0.25mV
0 to 20mA
4 to 20mA 1μA
0 to 16000
0 to 16000
*3
3
0.3125mV
1.25μA
3.2 Performance Specifications
27
*1 For details on the I/O conversion characteristics, refer to the following:
• I/O Conversion Characteristics of A/D Conversion ( Page 229, Appendix 4)
*2 Except for the conditions under noise influence. *3 This current value is an instantaneous value at which no breakdown occurs in the internal resistance of the module. The
maximum input current value for constant application is 24mA. *4 Do not connect two or more wires to the terminal. *5 The module operates at the conversion speed of a main analog module. For details, refer to the following:
• Conversion Speed and Sampling Period ( Page 90, Section 8.5.1)
28