Mitsubishi Electric MU-GD08ND, MU-GD10ND, MU-GD12ND Service Manual

CONTENTS
1. TECHNICAL CHANGES
····································
2
2. PART NAMES AND FUNCTIONS
······················
3
3. SPECIFICATION
4
4. OUTLINES AND DIMENSIONS
·························
5
5. WIRING DIAGRAM
············································
6
6. REFRIGERANT SYSTEM DIAGRAM
················
7
7. PERFORMANCE CURVES
································
9
8. TROUBLESHOOTING
······································
11
9. DISASSEMBLY INSTRUCTIONS
····················
12
SPLIT-TYPE, AIR CONDITIONERS
MU-GD08ND­MU-GD10ND­MU-GD12ND-
C1
C1
C1
TM
Indoor unit service manual
MS-GD•ND Series (TBH014)
No. TBH016
SERVICE MANUAL
Wireless type Models
OUTDOOR UNIT
NOTE:
• RoHS compliant products have <G> mark on the spec name plate.
PARTS CATALOG (TBB016)
MU-GD08ND-
C1
2
TECHNICAL CHANGES1
MU-A08ND-
C2
= MU-GD08ND-
C1
1. Compressor has been changed. (2R10S3R236A-6B = KS-098NARC)
2. Outdoor fan motor has been changed. (RA6N33-AA = RA6V21-BE)
3. Outdoor heat exchanger has been changed.
4. Compressor capacitor has been changed.
5. Fan motor capacitor has been changed.
MU-A12ND- C1 = MU-GD12ND-
C1
1. Compressor has been changed. (RH174NHNT = RH189NRAT)
2. Outdoor fan motor has been changed. (RA6N30-BA = RA6V33-MC)
3. Compressor capacitor has been changed.
4. Fan motor capacitor has been changed.
MU-A10ND-
C2
= MU-GD10ND-
C1
1. Model name changed.
3
2
PART NAMES AND FUNCTIONS
Air outlet
Drain outlet
Piping
Drain hose
Air inlet (back and side)
MU-C08VC MU-C10VC MU-C13VC
MU-C18VC
Air inlet (back and side)
Piping
Drain hose
Air outlet
Drain outlet
MU-GD08ND
MU-GD10ND MU-GD12ND
4
SPECIFICATION
3
Outdoor model
MU-GD08ND -
C1
MU-GD10ND -
C1
MU-GD12ND -
C1
Function Cooling
Power supply
Single phase
220-230V, 60Hz
Capacity
Capacity kW 2.2-2.2 2.9-2.9 3.6-3.6
Dehumidifi cation R/h 0.1 0.45 1.1
Air fl ow K /h 1896-1962 1452-1524 2106-2124
Electrical data
Power outlet A 10 10 10
Running current (Total) A 3.19-3.24 4.31-4.31 5.7-5.7
Power input (Total) W 680-685 930-930 1210-1210
Power factor (Total) % 97-92 98-94 96-92
Starting current A 19 26 40
Compressor motor current A 2.67-2.71 3.86-3.85 5.14-5.13
Fan motor current A 0.330-0.340 0.260-0.270 0.370-0.380
Coeffi cient of performance (C.O.P) 3.24-3.21 3.12-3.12 2.98-2.98
Compressor
Model KS098NARC RH145NHNT RH189NRAT
Output W 500 700 900
Winding resistance (at 20:)
Ω
C-R 3.54 C-S 4.90
C-R 2.74 C-S 3.78
C-R 1.50 C-S 2.33
Fan
motor
Model RA6V21-BE RA6N21-AB RA6V33-MC
Winding resistance (at 20:)
Ω
WHT-BLK 252 BLK-RED 278
WHT-BLK 384 BLK-RED 259
WHT-BLK 141 BLK-RED 175
Dimensions WxHxD mm 684x540x255 800x550x285
Weight kg 22 34 35
Special
remarks
Sound level dB 46-47 46-46 50-51
Fan speed rpm 820-830 690-720 980-990
Fan speed regulator 1
Refrigerant fi lling capacity (R22) kg 0.55 1.10
Refrigeration oil (Model) cc 300(NM56) 520(NM56)
NOTE: Test conditions are based on CNS 14464 Cooling : Indoor Dry-bulb temperature 27°C Wet-bulb temperature 19°C Outdoor Dry-bulb temperature 35°C Wet-bulb temperature 24°C Refrigerant piping length (one way) 7.5 m
5
4
OUTLINES AND DIMENSIONS
20.8
6.441 6
. 98
255
145.5
Service panel
Service port
Air out
Liquid refrigerant pipe joint Refrigerant pipe (flared) ;6.35
Gas refrigerant pipe joint Refrigerant pipe (flared) ;9.52
34
04
REQUIRED SPACE
Basically open 100mm or more without any obstruction in front and on both sides of the unit.
ero
m
r
o m
m0
5
3
ero
m
ro
mm0
01
erom ro
m
m00
1
erom
ro mm001
Open two sides of left, right, or rear side.
Air in
Air in
381.5
Drain hole
;33
ro f
hct ip t
loB
noitalla
tsni
082~462
0 03
045
072
0 1
5.74
5. 22
17.5
243
Bolt pitch for installation
500
684
61
105
Handle
2 holes 10'16
40
Unit : mm
Unit : mm
0 1
69
800
302.5
500 Bolt pitch for installation
150
22.3
Handle
055
0 82
5. 46
1
5.9 9
170.5
23
Service panel
Service port
582
5.44
3
44
400
Air in
Air out
5.7 1
r o
f hct
i p tlo
B
no ital
lats
n
i
52 3
~ 4 03
40
Liquid refrigerant pipe joint Refrigerant pipe (flared) ;6.35
Gas refrigerant pipe joint Refrigerant pipe (flared)
34
53
2 holes 10'21
REQUIRED SPACE
Basically open 100mm or more without any obstruction in front and on both sides of the unit.
erom ro m
m053
erom
ro mm002
erom ro
mm
00
1
e
rom ro mm001
Open two sides of left, right, or rear side.
Drain hole ;42
Air in
;9.52 (MU-GD10ND) ;12.7 (MU-GD12ND)
MU-GD08ND
MU-GD10ND MU-GD12ND
6
WIRING DIAGRAM
5
MU-C08VC MU-C10VC
MU-C13VC
MU-GD08ND
MU-GD10ND
Loading...