• To use this unit correctly and safely, be sure to read these operating in­structions before use.
En-1
● OPERATING INSTRUCTIONS ●
WARNING
Do not connect the power cord to an intermediate point, use an extension cord, or connect multiple devices to a single AC outlet.
• This may cause overheating, fi re, or electric shock.
Make sure the power plug is free of dirt and insert it se­curely into the outlet.
• A dirty plug may cause fi re or electric shock.
Do not bundle, pull, or modify the power cord, and do not apply heat or place heavy objects on it.
• This may cause fi re or electric shock.
Do not turn the breaker OFF/ON or disconnect/connect the power plug during operation.
• This may create sparks, which can cause fi re.
• After the indoor unit is switched OFF with the remote con­troller, make sure to turn the breaker OFF or disconnect the power plug.
Do not expose your body directly to cool air for a prolonged length of time.
• This could be detrimental to your health.
The unit should not be installed, relocated, or repaired by the user.
• An improperly handled air conditioner may cause fi re or electric shock.
This appliance is not intended for use by persons (includ­ing children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concern­ing use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
• Since rotating parts and parts which could cause an electric shock are used
in this product, be sure to read these “Safety Precautions” before use.
• Since the cautionary items shown here are important for safety, be sure to
observe them.
• After reading this manual, keep it together with the installation manual in a
handy place for easy reference.
• Be sure to receive a guarantee card from your dealer and check that the
purchased date and shop name, etc. are entered correctly.
Marks and their meanings
WARNING :
Incorrect handling could cause serious hazard, such as
death, serious injury, etc. with a high probability.
CAUTION :
Incorrect handling could cause serious hazard depending on the conditions.
Do not insert your fi nger, a stick, or other objects into the
air inlet or outlet.
• This may cause injury, since the fan inside rotates at high speeds during operation.
In case of an abnormal condition (such as a burning smell), stop the air conditioner and disconnect the power plug or turn the breaker OFF.
• A continued operation in the abnormal state may cause a
malfunction, fi re, or electric shock. In this case, consult your
dealer.
When the air conditioner does not cool or heat, there is a possibility of refrigerant leakage. In this case, consult your dealer. If a repair involves recharging the unit with refrigerant, ask the service technician for details.
• The refrigerant used in the air conditioner is safe. Normally,
it does not leak. However, if refrigerant leaks and comes in contact with a heat source such as a fan heater, kerosene heater, or cooking stove, it will create a harmful gas.
CAUTION
Do not touch the air inlet or the aluminum fi ns of the
indoor/outdoor unit.
• This may cause injury.
Do not use insecticides or fl ammable sprays on the unit.
• This may cause a fi re or deformation of the unit.
Do not expose pets or houseplants to direct airfl ow.
• This may cause injury to the pets or plants.
Do not place other electric appliances or furniture under the indoor/outdoor unit.
• Water may drip down from the unit, which may cause damage
or malfunction.
Do not leave the unit on a damaged installation stand.
• The unit may fall and cause injury.
Meanings of symbols used in this manual
: Be sure not to do.
: Be sure to follow the instruction.
: Never insert your fi nger or stick, etc.
:
Never step onto the indoor/outdoor unit and do not put anything on them.
: Danger of electric shock. Be careful.
: Be sure to disconnect the power supply plug from the power outlet.
: Be sure to shut off the power.
SAFETY PRECAUTIONS
CONTENTS
SAFETY PRECAUTIONS 1
NAME OF EACH PART 3
PREPARATION BEFORE OPERATION 3
AREA SETTING 4
SELECTING OPERATION MODES 5
FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 6
ECONO COOL OPERATION 7
TIMER OPERATION (ON/OFF TIMER) 7
PLASMA OPERATION 7
CLEAN OPERATION 7
CLEANING 8
WHEN YOU THINK THAT TROUBLE HAS OCCURRED 9
WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 10
INSTALLATION PLACE AND ELECTRICAL WORK 10
SPECIFICATIONS 10
En-2
CAUTION
Do not step on an unstable bench to operate or clean the unit.
• This may cause injury if you fall down.
Do not pull the power cord.
• This may cause a portion of the core wire to break, which may cause overheating or fi re.
Do not charge or disassemble the batteries, and do not
throw them into a fi re.
• This may cause the batteries to leak, or cause a fi re or explo-
sion.
Do not operate the unit for a long time at high humidity (80% RH or more), such as with a door or window left open.
• The water condensation in the air conditioner may drip down, wetting or damaging the furniture.
Do not use the unit for special purposes, such as storing food, raising animals, growing plants, or preserving preci­sion devices or art objects.
• This may cause deterioration of quality, or harm to animals and plants.
Do not expose combustion appliances to direct airfl ow.
• This may cause incomplete combustion.
Before cleaning the unit, switch it OFF and disconnect the power plug or turn the breaker OFF.
• This may cause injury, since the fan inside rotates at high speeds during operation.
When the unit will be unused for a long time, disconnect the power plug or turn the breaker OFF.
• The unit may accumulate dirt, which may cause overheating or fi re.
Replace all batteries of the remote controller with new ones of the same type.
• Using an old battery together with a new one may cause overheating, leakage, or explosion.
If the battery fl uid comes in contact with your skin or clothes,
wash them thoroughly with clean water.
• If the battery fl uid comes in contact with your eyes, wash them thoroughly with clean water and immediately seek medical
attention.
Ensure that the area is well-ventilated when the unit is oper­ated together with a combustion appliance.
• Inadequate ventilation may cause oxygen starvation.
Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike.
• The unit may be damaged if lightning strikes.
After the air conditioner is used for several seasons, per­form inspection and maintenance in addition to normal cleaning.
• Dirt or dust in the unit may create an unpleasant odor or clog
the drain passage, and cause water to leak from the indoor
unit. Consult your dealer for inspection and maintenance,
which require specialized knowledge and skills.
WARNING
Consult your dealer for installing the air conditioner.
• It should not be installed by the user since installation requires
specialized knowledge and skills. An improperly installed air conditioner may cause water leakage, fi re, or electric shock.
Provide a dedicated power supply for the air conditioner.
• A non-dedicated power supply may cause overheating or fi re.
Do not install the unit where fl ammable gas could leak.
• If gas leaks and accumulates around the outdoor unit, it may cause an explosion.
Earth the unit correctly.
• Do not connect the earth wire to a gas pipe, water pipe, light­ning rod, or a telephone ground wire. Improper earthing may cause electric shock.
CAUTION
Install an earth leakage breaker depending on the installa­tion location of the air conditioner (such as highly humid areas).
• If an earth leakage breaker is not installed, it may cause electric shock.
Ensure that the drain water is properly drained.
• If the drain passage is improper, water may drip down from the indoor/outdoor unit, wetting and damaging the furniture.
In case of an abnormal condition
Immediately stop operating the air conditioner and consult your dealer.
SAFETY PRECAUTIONS
Do not operate switches with wet hands.
• This may cause electric shock.
Do not clean the air conditioner with water or place an object
that contains water, such as a fl ower vase, on it.
• This may cause fi re or electric shock.
Do not step on or place any object on the outdoor unit.
• This may cause injury if you or the object falls down.
For installation
En-3
● OPERATING INSTRUCTIONS ●
• Make sure the polarity of the batteries is correct.
Do not use manganese batteries. The remote controller could malfunction.
• Do not use rechargeable batteries.
• Replace all batteries with new ones of the same type.
• Batteries can be used for approximately 1 year. However, batteries with expired shelf lives last shorter.
• Press RESET gently using a thin instrument.
If the RESET button is not pressed, the remote controller may not operate
correctly.
Before operation: Insert the power supply plug into the power outlet and/or turn the breaker on.
• Press CLOCK gently using a thin instrument.
Display section
Operation
indicator lamp
Remote control receiving section
Emergency operation
switch Page 5
Air inlet (back and side)
Piping Drainage hose
Air outlet
Drain outlet
Remote controller holder
Signal transmitting section Distance of signal : About 6 m
Beep(s) is (are) heard from the indoor unit when
the signal is received.
Operation display
section
ON/OFF (operate/stop)
button
Temperature buttons
Page 5
Operation select
button Page 5
ECONO COOL
button
Page 7
FAN speed control button
Page 6
Off-timer button Page 7 On-timer button Page 7
VANE control button
Page 6
TIME set buttons Pages 3, 7 Increase time Decrease time
CLOCK button Page 3
RESET button Page 3
Lid
Slide down
to open
• Install the remote control-
ler holder in a place where
the signal can be received by the indoor unit.
Only use the remote controller provided with the unit.
Do not use other remote controllers.
Horizontal vane
Vertical vane
Air outlet
Fan
Air fi lter
Air inlet
Heat exchanger
Front panel
Plasma anti-allergy
enzyme fi lter
Fan guard
Outdoor unit
Installing the remote controller batteries Setting current time
NAME OF EACH PART
PREPARATION BEFORE OPERATION
1.
Remove the front lid
2.
Insert AAA
alkaline batteries
3.
Install the front lid
4.
Press RESET
1.
Press CLOCK
3.
Press CLOCK again
2.
Press the TIME buttons to set the
time.
Each press increases/decreases
the time by 1 minute (10 minutes when pressed longer)
Indoor unit Remote controller
Outdoor units may be different in appearance.
Plasma deodorizing
fi lter
CLEAN button
Page 7
WIDE VANE button Page 6
AREA button Page 4
PLASMA
button
Page 7
i-see button Page 4
i-see sensor Page 4
Plasma elec­trode unit
Page 7
Be sure to set the installation position before installing the batteries. Page 4