motor overheat protection, encoder error protection, regenerative error protection, undervoltage
protection, instantaneous power failure protection, overspeed protection, error excessive protection,
magnetic pole detection protection, and linear servo control error protection
*4
3-phase
200 V AC
to 240 V
AC, 50
Hz/60 Hz
3-phase
170 V AC
to 264 V
AC
8
1 SPECIFICATIONS
1.3 Servo amplifier standard specifications
*1 This value is applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of I/O points.
*2 When closely mounting the servo amplifiers, operate them at an ambient temperature of 0 ˚C to 45 ˚C or at 75 % or less of the effective
load ratio.
*3 This current value is applicable when a 3-phase power supply is used.
*4 If using 1-phase power supply in combination with the servo motor of 750 W or higher, operate the servo amplifier at 75 % or less of the
effective load ratio.
*5 The command communication cycle depends on the controller specifications and the number of the connected axes.
1
1 SPECIFICATIONS
1.3 Servo amplifier standard specifications
9
MR-J5W2-_G
Model: MR-J5W2-22G44G77G1010G
OutputVoltage3-phase 0 V AC to 240 V AC
Rated current (each axis) [A] 1.82.85.86.0
Main circuit power
supply input
Control circuit power
supply input
Interface power supplyVoltage24 V DC ±10 %
Control methodSine-wave PWM control, current control method
Dynamic brakeBuilt-in
CC-Link IE TSNCommunication cycle
Communication function USBConnection to a personal computer or others (MR Configurator2-compatible)
*1 This value is applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of I/O points.
*2 When closely mounting the servo amplifiers, operate them at an ambient temperature of 0 ˚C to 45 ˚C or at 75 % or less of the effective
load ratio.
*3 This current value is applicable when a 3-phase power supply is used.
*4 The command communication cycle depends on the controller specifications and the number of the connected axes.
Voltage/
Frequency
Rated current [A]
Permissible
voltage
fluctuation
Permissible frequency
fluctuation
Power supply capacity [kVA]Refer to "Power supply capacity and generated loss" in the following manual.
Inrush current [A]Refer to "Inrush currents at power-on of the main circuit and control circuit power supplies" in the
Voltage/
Frequency
Rated current [A]0.4
Permissible
voltage
fluctuation
Permissible frequency
fluctuation
Power consumption [W]55
Inrush current [A]Refer to "Inrush currents at power-on of the main circuit and control circuit power supplies" in the
Current capacity [A]0.35 (including CN8 connector signals)
Authentication class Class B
CE markingLVD: EN 61800-5-1, EMC: EN 61800-3 MD: EN ISO 13849-1, EN 61800-5-2, EN 62061
UL standardUL 61800-5-1
At AC input 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz3-phase 200 V AC to
240 V AC, 50 Hz/60
Hz
At DC input 283 V DC to 340 V DC
*3
At AC input 3-phase or 1-phase 170 V AC to 264 V AC3-phase 170 V AC to
At DC input 241 V DC to 374 V DC
At AC input 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz
At DC input 283 V DC to 340 V DC
At AC input 1-phase 170 V AC to 264 V AC
At DC input 241 V DC to 374 V DC
*4
2.95.27.59.8
264 V AC
Within ±5 %
MR-J5 User's Manual (Hardware)
following manual.
MR-J5 User's Manual (Hardware)
Within ±5 %
following manual.
MR-J5 User's Manual (Hardware)
*1
62.5 μs, 125 μs, 250 μs, 500 μs, 1 ms, 2 ms, 4 ms
motor overheat protection, encoder error protection, regenerative error protection, undervoltage
protection, instantaneous power failure protection, overspeed protection, error excessive protection,
magnetic pole detection protection, and linear servo control error protection
Force cooling, open (IP20)
(IP20)
Possible
10
1 SPECIFICATIONS
1.3 Servo amplifier standard specifications
MR-J5W3-_G
Model: MR-J5W3-222G444G
OutputVoltage3-phase 0 V AC to 240 V AC
Rated current (each axis) [A] 1.82.8
Main circuit power
supply input
Control circuit power
supply input
Interface power supplyVoltage24 V DC ±10 %
Control methodSine-wave PWM control, current control method
Dynamic brakeBuilt-in
CC-Link IE TSNCommunication cycle
Communication function USBConnection to a personal computer or others (MR Configurator2-compatible)
Encoder output pulsesAvailable only on axes A and B (A/B-phase pulse)
Power supply capacity [kVA]Refer to "Power supply capacity and generated loss" in the following manual.
Inrush current [A]Refer to "Inrush currents at power-on of the main circuit and control circuit power supplies" in the
Voltage/
Frequency
Rated current [A]0.4
Permissible
voltage
fluctuation
Permissible frequency
fluctuation
Power consumption [W]55
Inrush current [A]Refer to "Inrush currents at power-on of the main circuit and control circuit power supplies" in the
Current capacity [A]0.45 (including CN8 connector signals)
Authentication classClass B
CE markingLVD: EN 61800-5-1, EMC: EN 61800-3 MD: EN ISO 13849-1, EN 61800-5-2, EN 62061
UL standardUL 61800-5-1
At AC input 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz
At DC input 283 V DC to 340 V DC
*3
At AC input 3-phase or 1-phase 170 V AC to 264 V AC
At DC input 241 V DC to 374 V DC
At AC input 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz
At DC input 283 V DC to 340 V DC
At AC input 1-phase 170 V AC to 264 V AC
At DC input 241 V DC to 374 V DC
*4
4.37.8
Within ±5 %
MR-J5 User's Manual (Hardware)
following manual.
MR-J5 User's Manual (Hardware)
Within ±5 %
following manual.
MR-J5 User's Manual (Hardware)
*1
125 μs, 250 μs, 500 μs, 1 ms, 2 ms, 4 ms
motor overheat protection, encoder error protection, regenerative error protection, undervoltage
protection, instantaneous power failure protection, overspeed protection, error excessive protection,
magnetic pole detection protection, and linear servo control error protection
Possible
*1 This value is applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of I/O points.
*2 When closely mounting the servo amplifiers, operate them at an ambient temperature of 0 ˚C to 45 ˚C or at 75 % or less of the effective
load ratio.
*3 This current value is applicable when a 3-phase power supply is used.
*4 The command communication cycle depends on the controller specifications and the number of the connected axes.
1
1 SPECIFICATIONS
1.3 Servo amplifier standard specifications
11
Functional safety
• The functional safety is not available for MR-J5W_-_G servo amplifiers.
ItemSpecifications
Functional safetySTO (IEC/EN 61800-5-2)
Safety performanceStandards certified by CBEN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN 62061 SIL CL3, EN 61800-5-2
Response performance8 ms or less (STO input off → energy shut off)
Test pulse input (STO)
Mean time to dangerous
failure (MTTFd)
Diagnostic coverage (DC)DC = Medium, 97.6 [%]
Probability of dangerous
Failure per Hour (PFH)
*1
*1 A test pulse is a signal which instantaneously turns off a signal to the servo amplifier at a constant period for external circuit to self-
diagnose.
Test pulse interval: 1 Hz to 25 Hz, test pulse off time: Up to 1 ms
MTTFd ≥ 100 [years] (314a)
-9
PFH = 6.4 × 10
[1/h]
Environment
ItemOperationTransportationStorage
Ambient
temperature
Ambient humidity5 %RH to 95 %RH (non-condensing)5 %RH to 95 %RH (non-condensing)5 %RH to 95 %RH (non-condensing)
AmbienceIndoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust
Altitude/
atmospheric
pressure
Vibration resistance When there is continuous vibration:
*1 Refer to "Restrictions on using this product at an altitude exceeding 1000 m and up to 2000 m above sea level" in the following manual
for using the product at an altitude exceeding 1000 m above sea level.
MR-J5 User's Manual (Hardware)
0 ˚C to 60 ˚C (non-freezing)
Class 3K3 (IEC 60721-3-3)
Altitude: 2000 m or less
10 Hz to 57 Hz, displacement amplitude
0.075 mm
57 Hz to 150 Hz, acceleration amplitude
2
9.8 m/s
Class 3M1 (IEC 60721-3-3)
When there is continuous vibration:
10 Hz to 55 Hz, acceleration amplitude 5.9
2
m/s
*1
-25 ˚C to 70 ˚C (non-freezing)
Class 2K3 (IEC 60721-3-2)
Transportation conditions: Must be
transported by ground/sea, or air at an
atmospheric pressure of 700 hPa or more.
2 Hz to 8 Hz, displacement amplitude (half
amplitude) 7.5 mm
8 Hz to 200 Hz, acceleration amplitude 20
2
m/s
Class 2M3 (IEC 60721-3-2)
-25 ˚C to 70 ˚C (non-freezing)
Class 1K3 (IEC 60721-3-1)
Atmospheric pressure: 700 hPa to 1060
hPa
(equivalent to the altitude of -400 m to 3000
m.)
2 Hz to 9 Hz, displacement amplitude (half
amplitude) 1.5 mm
9 Hz to 200 Hz, acceleration amplitude 5
2
m/s
Class 1M2 (IEC 60721-3-1)
12
1 SPECIFICATIONS
1.3 Servo amplifier standard specifications
1.4Function block diagram
UU
U
L11
L21
N-CD
L3
L2
L1
MCMCCB
U
V
W
U
V
W
P3P4P+
+
+
B
RAB1
B2
CN4
M
CN2
CN8
*1
CN2L
*3
CN5
USB
USB
CN1A
CN1B
D/A
CN3CN6
Power factor improving
DC reactor
Regenerative
option
Servo amplifierServo motor
Diode stack
Dynamic brake
circuit
Relay
Current
detector
Power
supply
Regenerative
TR
Charge
light
Cooling fan
*2
Electromagnetic
brake
Control
circuit
power supply
STO
circuit
STO
switch
Encoder
Overcurrent
protection
Base
amplifier
Voltage
detection
Current
detection
Stepdown
circuit
Control engine
Battery
*4
I/F control
External encoder
Personal
computer
Analog monitor
(2 channels)
Digital I/O
control
Controller or
servo
amplifier
Controller or
servo
amplifier
24 V DC
The following shows the function block diagram of this servo amplifier.
MR-J5-_G_
1
*1 The built-in regenerative resistor is not provided for MR-J5-10G.
*2 Servo amplifiers with the rated output symbol of 70 (MR-J5-70G) or greater have a cooling fan.
*3 This is for the MR-J5-_G-RJ servo amplifier. MR-J5-_G servo amplifier does not have CN2L connector.
*4 To configure the absolute position detection system by using a direct drive motor, the battery is required. When the absolute position
detection system is to be configured by using the HK series servo motor, the battery is not required.
1 SPECIFICATIONS
1.4 Function block diagram
13
MR-J5W_-_G
U
V
W
U
V
W
U
V
W
M
E
M
E
M
E
CNP1
TRM (A)
CNP2
P+ CD
MCCBMC
CNP2
CNP3A
CN2ACNP3B
CN2B
CNP3CCN2CCN4
CN3CN6CN5
USB
MR-BT6VCASE
L1
L2
L3
L11
L21
CN8CN1ACN1B
+
+
U
U U
*1
CNP1
P4N-
*2
Regenerative option
Diode
stack
Built-in
regenerative
resistor
A-axis
servo motor
Relay
Regenerative
TR
A-axis
output
Current
detector
Power
supply
Charge
light
Dynamic
brake circuit A
A-axis
F/B
Cooling fan
STO circuit
Control
circuit
power
supply
B-axis
servo motor
Base
amplifier
Current
detection A
Overvoltage
Overcurrent
A
B-axis
output
Control engine
STO switch
B-axis
F/B
Controlling B-axis
Controller or
servo amplifier
C-axis
servo motor
Controlling C-axis
C-axis
output
I/F
control
Controller or
servo amplifier
C-axis
F/B
Stepdown
circuit
Battery case
+ battery
Analog
output
Digital I/O
control
Personal
computer
The following is an example using MR-J5W3-_G.
*1 The MR-J5W2-22G has no cooling fan.
*2 To configure the absolute position detection system by using a direct drive motor, the battery is required. When the absolute position
detection system is to be configured by using the HK series servo motor, the battery is not required.
14
1 SPECIFICATIONS
1.4 Function block diagram
1.5Configuration including peripheral equipment
CN5
P+
C
L11
L21
P3
P4
MR Configurator2
CN6
CN8
CN3
CN2
W
V
U
L1
L2
L3
*1
(MC)
CN2L
*2
RS T
(FR-BSF01)
(FR-HEL)
(MCCB)
CN1B
CN1A
Power supply
Controller or
servo amplifier
Molded-case
circuit breaker
Controller or
servo amplifier
Personal
computer
Magnetic
contactor
Line noise filter
Analog monitor
Safety relay
Junction terminal block
Power factor
improving
DC reactor
Servo motor
Regenerative
option
• Do not connect these connectors to other than specified network. Otherwise, a malfunction may occur.
• Equipment other than the servo amplifier and servo motor is optional or recommended products.
The following is an example using MR-J5-20G-RJ.
1
*1 The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
*2 This is for the MR-J5-_G-RJ servo amplifier. MR-J5-_G servo amplifier does not have CN2L connector. If using MR-J5-_G-RJ servo
amplifier in the linear servo system, connect an external encoder to this connector. Refer to the following for the compatible external
encoders.
Page 24 Parts identification
1 SPECIFICATIONS
1.5 Configuration including peripheral equipment
15
2FUNCTION
2.1Function list
The following table lists the functions of this servo. For details of the functions, refer to each section indicated in the detailed
Universal driveLinear servo motorThe linear servo system can be configured using a linear
Direct drive motorThe direct drive servo system can be configured to drive
EncoderHigh-resolution encoderHigh-resolution encoder of 67108864 pulses/rev is used
Batteryless absolute position
encoder
servo motor and a linear encoder.
a direct drive motor.
for the encoder of the rotary servo motor.
The rotation position of the servo motor can be backed up
without the battery. Using the servo motor with this
encoder can configure the absolute value detection
system without the battery.
Refer to "When using linear
servo motor" in the following
manual.
MR-J5 User's Manual
(Hardware)
Refer to "When using direct
drive motor" in the following
manual.
MR-J5 User's Manual
(Hardware)
Refer to "Absolute position
detection system" in the
following manual.
MR-J5 User's Manual
(Hardware)
Stop functionQuick StopStops the servo motor with a specified method and
switches to the servo-off status.
HaltStops the servo motor as maintaining the servo-on status. Refer to "Halt" in the following
Stroke limit functionThe travel interval of the servo motor can be limited with
LSP (Forward rotation stroke end) and LSN (Reverse
rotation stroke end).
Travel intervals can be limited with FLS (Upper stroke
limit) and RLS (Lower stroke limit) via a controller.
Software position limitLimits travel intervals by address, using servo
parameters. A function equivalent to the stroke limit
function can be set with the servo parameter.
Command generationRotation/travel direction selectionServo motor rotation direction can be set without
changing the command polarity.
Electronic gearPositioning control is performed with the value obtained
by multiplying the position command from the upper
controller by a set electronic gear ratio.
Acceleration/deceleration functionSet the time constant of acceleration and deceleration.Refer to "Acceleration/
Torque limitLimits the servo motor torque.Refer to "Torque limit" in the
Speed limitServo motor speed in the torque control mode can be
limited to any value.
Refer to "Quick stop" in the
following manual.
MR-J5 User's Manual
(Function)
manual.
MR-J5 User's Manual
(Function)
Refer to "Stroke limit function"
in the following manual.
MR-J5 User's Manual
(Function)
Refer to "Software position
limit" in the following manual.
MR-J5 User's Manual
(Function)
Refer to "Rotation/travel
direction selection" in the
following manual.
MR-J5 User's Manual
(Function)
Refer to "Electronic gear
function" in the following
manual.
MR-J5 User's Manual
(Function)
deceleration function" in the
following manual.
MR-J5 User's Manual
(Function)
following manual.
MR-J5 User's Manual
(Function)
Refer to "Speed limit" in the
following manual.
MR-J5 User's Manual
(Function)
Shaft resonance suppression filterWhen a load is mounted to the servo motor shaft,
Robust filterImproves a disturbance response when a response
Slight vibration suppression controlSuppresses vibration of ±1 pulse generated at each servo
Tracking controlLost motion compensation functionImproves the response delay generated when the
Path tracking model adaptive control Tracking error in a small reciprocating motion can be
This function suppresses vibration and residual vibration
at an arm end.
Decreases the gain of the specific frequency to suppress
the resonance of the mechanical system.
resonance by shaft torsion during driving may generate a
mechanical vibration at high frequency. The shaft
resonance suppression filter suppresses the vibration.
performance cannot be increased because of a large load
to motor inertia ratio, such as a roll feed axis.
motor stop.
machine moving direction is reversed.
reduced.
Refer to "Advanced vibration
suppression control II" in the
following manual.
MR-J5 User's Manual
(Adjustment)
Refer to "Machine resonance
suppression filter" in the
following manual.
MR-J5 User's Manual
(Adjustment)
Refer to "Shaft resonance
suppression filter" in the
following manual.
MR-J5 User's Manual
(Adjustment)
Refer to "Robust filter" in the
following manual.
MR-J5 User's Manual
(Adjustment)
Refer to "Slight vibration
suppression control" in the
following manual.
MR-J5 User's Manual
(Adjustment)
Refer to "Lost motion
compensation function" in the
following manual.
MR-J5 User's Manual
(Adjustment)
Refer to "Path tracking model
adaptive control" in the
following manual.
MR-J5 User's Manual
(Adjustment)
18
2 FUNCTION
2.1 Function list
Loading...
+ 44 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.