GU-C40
MITSUBISHI GATE DRIVER FOR GCT THYRISTOR
GU-C40
High Power Inverter Use
APPLICATION
Inverters, Converters, DC choppers, Induction heating, DC to DC converters.
OUTLINE DRAWING & CIRCUIT DIAGRAM Dimensions in mm
OPTICAL RECEIVER
HFBR-2522
(HP:BLUE TERMINAL)
CONNECTOR FOR
DC POWER SUPPLY
B9PS-VH
(JST)
EXPLANATION OF
TERMINAL NUMBERS
+
+
5 ± 0.5V
20 ± 1V
PCDφ134
(12.5)
(29)
10
40
987654321
PC BOARD SIDE
GATE ATTACHMENT
φ128
6.5
φ148
38
78.5
133
169
NAME
PLATE
229
369
A PARTIAL
SECTIONAL VIEW
449
3.2
φ134
8.5
φ148
16-M3+0.5 SCREW
φ124
11.25°
11.25°
15.3
8.5
A
CATHODE BLOCK
THICKNESS
2.0
Aug.1998
MITSUBISHI GATE DRIVER FOR GCT THYRISTOR
GU-C40
High Power Inverter Use
CHARACTERISTICS
4.5
19
—
—
28
44
—
10
—
—
—
Limits
5.0
20
—
—
30
50
7
5
8
6
—
200
—
5
—
6000
—
—
—
0.012
5.5
21
—
500
32
52
—
—
—
—
—
50
+60
Unit
V
V
—
Hz
µs
µs
9
µs
7
µs
A/µs
A
µs
A
A/µs
%
°C
°C/W
Symbol
+V
C
–VC
–
f
ton min
toff min
t
fd
trd
diG/dt
IGM
tw
IG
diGQ/dt
Dmax
Ta
R
th
Note 1. In case of DC power supply which has no current control, please be careful that rush current (peak value 140A, width 2ms) flows at the turn on of
Power supply (+)
Power supply (–)
Control signal
Frequency
Turn-on minimum
Turn-off minimum
Delay time of on gate current
Delay time of off gate current
Critical rate of rise of on gate current
Peak on gate current
Width of on high gate current
On gate current
Critical rate of rise of off gate current
Maximum duty
Temperature
Thermal resistance
(Junction to Fin)
power supply in 1m cable for power supply.
2. In case of DC power supply which has no current control, please be careful that rush current (peak value 140A, width 2ms) flows at the turn on of
power supply in 1m cable for power supply.
3. Main current condition of GCT Thyristor is 1500Arms and duty 50%.
4. If input turn-on signal is shorter than ton (min) protection operates and turn on width is 28µs min and 32µs max.
5. If turn-on signal is input during toff (min) protection operates and turn off width is 44µs min and 52µs max.
6. If GU-C40 and FGC4000BX-90DS are used together, Rth (j-f) is becomes 0.012°C/W.
(Only FGC4000BX-90DS is used. R
Parameter Test conditions
DC power supply 10A (Note 1, 3)
DC power supply 6A (Note 2, 3)
Optical fiber data link
Receiver: HFBR-2522 (HP)
1500Arms Duty 50%
Protection is 28µs min and 32µs max. (Note 4)
Protection is 44µs min and 52µs max. (Note 5)
V
RG = 20V
GU-C40 and FGC4000BX-90DS
th(j-f) becomes 0.011°C/W)
Min Typ Max
100
–10
(Note 6)
Aug.1998