Mitsubishi GOT2000, GT2710-VTWD, GT2712-STWD, GT2508-VTWD, GT2510-VTWD Supplementary Description

GOT2000 Series Supplementary
DANGER
DANGER
DANGER
DANGER
DANGER
For GT2712-STWD (8 fittings)
a
a
a
b
a
b
a: Use the Installation fitting (4 fittings) b: Use GT25-12FIT-EXS (separately sold product). (4 fittings) In the middle (b
*1
) of the top, attach a large metal fittings
b
*1
b
Battery cover
Description
(Compliance with the ATEX Directive)
GT2712-STWD GT2710-VTWD GT2510-VTWD GT2508-VTWD
Thank you for purchasing the GOT2000 Series.
Prior to use, please read both this manual and the detailed manual thoroughly to fully understand the product.
MODEL GOT2000-U-ATEX-EK
Model
code
IB(NA)-0800551ENG-B(1609)MEE
(Always read these precautions before using this equipment.)
The GOT that complies with the ATEX Directive 94/9/EC of the EU Directives is in compliance with IECEx Scheme IEC 60079/0/15/31 standards has the Ex marking on its rating plate. To use the ATEX­compliant GOT in explosive atmospheres, thoroughly read this man­ual, the GOT2000 Series User's Manual (Hardware), and other rele­vant manuals introduced therein. Make sure to pay full attention to safety and handle the product correctly. The precautions given in this manual are concerned with the ATEX­compliant GOT to be used specifically in explosive atmospheres. In this manual, the safety precautions are ranked as "DANGER".
Always follow the instructions because they are important to per­sonal safety. Please save this manual to make it accessible when required and always forward it to the end user.
SAFETY PRECAUTIONS
Indicates that incorrect handling may cause hazardous conditions, resulting in death or serious injury.
[INSTALLATION PRECAUTIONS]
When conducting work (such as installing, operating, or maintaining the product) in an explosive atmosphere, conform to the following standards, laws, and regulations. Not doing so results in death or serious injury.
• Standard IEC 60079-14: Explosive atmospheres - Part 14: Electrical installations design, selection and erection
• Standard EN 60079-17: Explosive atmospheres - Part 17: Inspection and maintenance of electrical installations in hazardous areas
• Regional laws and regulations, etc.
Use both the fittings included with the GOT and separately sold special fittings (*1) to install the GOT to the control panel.
*1 When purchasing special fittings, consult your local Mitsubishi representative or branch office.
GOT GT2712-STWD GT2710-VTWD GT2510-VTWD
GT2508-VTWD does not require special fittings.
Special fitting name GT25-12FIT-EXS GT25-10FIT-EXS
1D7MQ3
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
a: Use the Installation fitting (4 fittings) b: Use GT25-10FIT-EXS (separately sold product). (2 fittings)
a: Use the Installation fitting (4 fittings) b: Use GT25-12FIT-EXS (separately sold product). (4 fittings) In the middle (b
• Press "b" (GT25-12FIT-EXS, GT25-10FIT-EXS) by hand and attach it.
Sold separately Protective sheet(*2) is attached on the GOT surface.
*2 For the Protective sheet sold separately, contact your local sales office.
GOT GT2712-STWD GT2710-VTWD GT2510-VTWD GT2508-VTWD
If the protective sheet without the hole for the USB environmental protection cover is attached, position the sheet from the upper left of the GOT.
For GT2508-VTWD (4 fittings)
a
a
a: Use the Installation fitting (4 fittings)
For GT2710-VTWD, GT2510-VTWD (6 fittings)
a
b
a
For GT2712-STWD (8 fittings)
a
b
a
b
*1
a
a
a
b
a
*1
b
a
b
a
) of the top, attach a large metal fittings
Protective sheet name GT25-12PSCC-UC GT25-10PSCC-UC
GT25-08PSCC-UC
To attach the protective sheet, attach it from one direction gradually. Make sure to fit the protective sheet onto the joining surface closely without leaving any air between them.
Attach the protective sheet with adding additional pressure sufficiently to the adhesive side of the outer circumference. To hold adequate strength of the adhesive joining, use the GOT after a lapse of about 24 hours.
If any of the fittings is out of place, the GOT installed to the control panel does not comply with the ATEX Directive. (The GOT cannot be used in explosive atmospheres.)
[PRECAUTIONS FOR INSTALLATION, REMOVAL, OPERATION, AND MAINTENANCE]
The ATEX-compliant GOT is usable in Zone 2 or Zone 22 explosive atmospheres.
• Low mechanical impact: This equipment is to be installed in an area of low mechanical impact.
• Electrostatic charging: Wipe the front panel with a damp cloth before turning on the equipment.
• Extension and auxiliary extension interfaces : Extension and auxiliary extension interfaces cannot be used in explosive atmospheres.
• Before mounting or demounting, replacing, or wiring the GOT, make sure that there is no explosive gas or dust around the product.
• The ambient temperature of the protective enclosure must be 55°C or less.
• Make sure that each interface, the terminal block, an SD card, and the battery cover are secured firmly into place.
• The USB cable must be clamped appropriately at the USB interface (Host/Device). (Figure 1 is an example of clamping a cable at the USB interface (Host).)
• The GOT must be installed in a protective enclosure with the following protective structure rating.
- IP54 for use in gas atmospheres
- IP6X for use in dust atmospheres
• The protective enclosure cannot be opened while the system is energized.
• Make sure to turn off the GOT, and then conduct work (such as wiring or installing the GOT and inserting or removing an SD card).
• Make sure that the FG terminal of the power supply is grounded.
• Make sure that the GOT is screwed firmly into place.
• Do not use any damaged equipment.
Figure 1
The following shows manuals relevant to this product.
GOT2000 Series User’s Manual (Hardware) SH-081194ENG (1D7MJ5)
For detailed manuals and relevant manuals, refer to the Help or the PDF manuals stored in the DVD-ROM for the screen design software used.
The latest manuals are also available from MITSUBISHI ELECTRIC FA Global Website (http://www.MitsubishiElectric.com/ fa/).
Before using the GOT
Connect the GOT to the battery. Refer to the GOT2000 Series User ’s Manual (Hardware) for the connection instructions. For details on the GOT specifications, installing instructions, wiring, maintenance and inspection, or checking procedure for the version and the compatible standard, refer to the GOT2000 Series User’s Manual (Hardware).
Manual name Manual number (Model code)
© 2016MITSUBISHI ELECTRIC CORPORATION
1. CONFORMING STANDARDS
The GOT with the Ex marking on its rating plate complies with the following standards.
- Standard EN 60079-0: Explosive atmospheres - Part 0: Equipment - General requirements
- Standard EN 60079-15: Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
- Standard EN 60079-31: Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
2. Ex MARKING
The ATEX-compliant GOT has the Ex marking on its rating plate as shown below.
The following shows the meaning of the Ex marking. (1) II 3G Ex nA IIC T5 Gc
(2) II 3D Ex tc IIIC T100°C Dc
(3) Tamb 0°C to +55°C
(4) TUV 15 ATEX 7585 X
(5) IECEx TUR 15.0030 X
|| 3 G Ex nA ||C T5 Gc || 3 D Ex tc |||C T100°C Dc Tamb 0°C to +55°C TUV 15 ATEX 7585 X IECEx TUR 15.0030 X
II: Product group (non-mining) 3G: Product category (Zone 2, gases/vapors) Ex: Explosion proof nA: Type of protection (Non-sparking equipment) IIC: Gas atmosphere (Typical gas: hydrogen) T5: Temperature class (Highest surface temperature: 100°C) Gc: Equipment protection level (Non-sparking equipment during normal operation)
II: Product group (non-mining) 3D: Product category (Zone 22, dusts) Ex: Explosion proof Tc: Type of protection (Dust ignition protection) IIIC: Dust atmosphere (Conductive dust) T100°C: Highest surface temperature 100°C Dc: Equipment protection level (Dust ignition protection by enclosure)
Operating ambient temperature ranging from 0°C to 55°C
Certificate number
Certificate number
Manual
3. INSTALLING AND REMOVING THE GOT
3.1 Installing the GOT
Install the GOT in the following procedure. For the panel cutting dimensions for the GOT, refer to the following. The following shows an installation example for the horizontal direction. For the vertical installation, install the GOT so that the vertical installation arrow printed on the GOT rear face points upward.
Step1. Insert the GOT rear face into the panel opening.
GOT
Panel opening
Step2. While positioning a fitting on the mounting hole of the GOT,
tighten a screw within the specified torque range (0.42 N·m to 0.48 N·m). Tightening the screw with a torque exceeding the specified torque range may deform the GOT front panel, causing the protective sheet to become crinkled.
For GT2508-VTWD (4 fittings)
a
a
3.2 Removing the GOT
Step1. Remove the screws from the GOT.
Remove the fittings from the GOT.
For GT2508-VTWD (4 fittings)
For GT2710-VTWD, GT2510-VTWD (6 fittings)
For GT2712-STWD (8 fittings)
4. INSTALLING AND REMOVING THE BATTERY
Install a battery to the GOT before the first startup. GT27 and GT25 come with a battery in the battery holder. Before using GT27 and GT25, connect the battery connector to the GOT connector. To replace the battery, leave the GOT on for more than 10 minutes before replacing the battery.Replace the battery within 5 minutes. The following shows the procedure for installing and removing a battery.(Described with the GOT rear face facing up.)
4.1 Installing the Battery
4.1.1 Installing the battery to GT2712-STWD, GT2710­VTWD or GT2510-VTWD
Step1. Make sure that the GOT power is off. Step2. Install the battery to the GOT rear face.
Open the battery cover as shown below.
Step3. Insert the battery connector to the GOT connector.
Battery cover
4.1.2 Installing the battery to GT2508-VTWD
Step1. Make sure that the GOT power is off. Step2. Install the battery inside the SD card cover on the side of the
GOT.Open the SD card cover as shown in the following fig­ure.
SD card cover
Step3. Insert the battery connector to the GOT connector.
SD card cover
Connector
Battery
Step4. After installing the battery to the battery holder of the GOT,
close the SD card cover until it clicks.
Black cable
Red cable
SD card coverBattery
a
a
a: Use the Installation fitting (4 fittings)
For GT2710-VTWD, GT2510-VTWD (6 fittings)
a
b
a
a: Use the Installation fitting (4 fittings) b: Use GT25-10FIT-EXS (separately sold product). (2 fittings)
a
Step2. Remove the GOT from the panel opening.
GOT
Battery
Without a battery extension cable
Step4. After installing the battery to the battery holder of the GOT,
Panel opening
b
a
close the battery cover until it clicks.
Step5. Turn on the GOT. Step6. Check that the battery condition is normal with the utility.
Connector
Battery coverBattery
Black cable
Red cable
Connector
Connector
Step5. Turn on the GOT. Step6. Check that the battery condition is normal with the utility. For
the details of the battery condition display, refer to the follow­ing.
4.2 Removing the Battery
4.2.1 Removing the battery to GT2712-STWD, GT2710­VTWD or GT2510-VTWD
Step1. Make sure that the GOT power is off. Step2. The battery is stored in the GOT rear face. Open the battery
cover as shown below.
Battery coverBattery
Connector
Step3. Unplug the battery connector from the GOT connector.
Battery cover
4.2.2 Removing the battery to GT2508-VTWD
Step1. Make sure that the GOT power is off. Step2. The battery is stored inside the SD card cover on the side of
the GOT. Open the SD card cover as shown in the following figure.
SD card coverBattery
Connector
Step3. After removing the battery from the battery holder of the GOT,
unplug the battery connector from the GOT connector.
SD card cover
Connector
5. EC DECLARATION OF CONFORMITY
Black cable
Red cable
Battery Connector
Without a battery extension cable
Step4. Push and close the battery cover until it clicks.
Battery cover
Battery
Step4. Close the SD card cover until it clicks.
SD card cover
Black cable
Red cable
Warra nty
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties.
For safe use
• This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.
• Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
Country/Region Sales office/Tel
USA
Brazil
Mexico
Germany
UK
Italy
Spain
France
Czech
Turkey
Poland
Russia
South Africa
China
Taiwan
Korea
Singapore
Thailand
Indonesia
Vietnam
India
Australia
Mitsubishi Electric Automation, Inc. 500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A. Tel: +1-847-478-2100 Mitsubishi Electric do Brasil Comercio e Servicos Ltda. Rua Jussara, 1750- Bloco B Anexo, Jardim Santa Cecilia, CEP 06465-070, Barueri - SP, Brasil Tel: +55-11-4689-3000 Mitsubishi Electric Automation, Inc. Mexico Branch Mariano Escobedo #69, Col. Zona Industrial, Tlalnepantla Edo. Mexico, C.P.54030 Tel: +52-55-3067-7511 Mitsubishi Electric Europe B.V. German Branch Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany Tel: +49-2102-486-0 Mitsubishi Electric Europe B.V. UK Branch Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, U.K. Tel: +44-1707-28-8780 Mitsubishi Electric Europe B.V. Italian Branch Centro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, 20864 Agrate Brianza (Milano), Italy Tel: +39-039-60531 Mitsubishi Electric Europe B.V. Spanish Branch Carretera de Rubi 76-80-Apdo.420, 08190 Sant Cugat del Valles (Barcelona), Spain Tel: +34-935-65-3131 Mitsubishi Electric Europe B.V. French Branch 25, Boulevard des Bouvets, 92741 Nanterre Cedex, France Tel: +33-1-55-68-55-68 Mitsubishi Electric Europe B.V. Czech Branch Avenir Business Park, Radlicka 751/113e, 158 00 Praha 5, Czech Republic Tel: +420-251-551-470 Mitsubishi Electric Turkey A.S. Umraniye Branch Serifali Mahallesi Nutuk Sokak No:5, TR-34775 Umraniye / Istanbul, Turkey Tel: +90-216-526-3990 Mitsubishi Electric Europe B.V. Polish Branch ul. Krakowska 50, 32-083 Balice, Poland Tel: +48-12-347-65-00 Mitsubishi Electric (Russia) LLC St. Petersburg Branch Piskarevsky pr. 2, bld 2, lit “Sch”, BC “Benua”, office 720; RU-195027 St. Petersburg, Russia Tel: +7-812-633-3497 Adroit Technologies 20 Waterford Office Park, 189 Witkoppen Road, Fourways, Johannesburg, South Africa Tel: +27-11-658-8100 Mitsubishi Electric Automation (China) Ltd. No.1386 Hongqiao Road, Mitsubishi Electric Automation Center, Shanghai, China Tel: +86-21-2322-3030 SETSUYO ENTERPRISE CO., LTD. 6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan Tel: +886-2-2299-2499 Mitsubishi Electric Automation Korea Co., Ltd. 7F-9F, Gangseo Hangang Xi-tower A, 401, Yangcheon Gangseo-Gu, Seoul 07528, Korea Tel: +82-2-3660-9530 Mitsubishi Electric Asia Pte. Ltd. 307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943 Tel: +65-6473-2308 Mitsubishi Electric Factory Automation (Thailand) Co., Ltd. 12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand Tel: +66-2682-6522 to 31 PT. Mitsubishi Electric Indonesia Gedung Jaya 11th Floor, JL. MH. Thamrin No.12, Jakarta Pusat 10340, Indonesia Tel: +62-21-3192-6461 Mitsubishi Electric Vietnam Co., LTD. Ho Chi Minh Head Office Unit 01-04, 10th Floor, Vincom Center, 72 Le Thanh Ton Street, District 1, Ho Chi Minh City, Vietnam Tel: +84-8-3910-5945 Mitsubishi Electric India Pvt. Ltd. Pune Branch Emerald House, EL -3, J Block, M.I.D.C., Bhosari, Pune - 411026, Maharashtra, India Tel: +91-20-2710-2000 Mitsubishi Electric Australia Pty. Ltd. 348 Victoria Road, P.O. Box 11, Rydalmere, N.S.W. 2116, Australia Tel: +61-2-9684-7777
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice. Printed in Japan, September 2016.
Loading...