Mitsubishi GT2512-STBA, GT2510-VTBD, GT2508-VTBD, GT2512-STBD, GT2510-VTWD General Description Manual

...
GT25 General Description
WARNING
CAUTION
WAR NI NG
WAR NI NG
CAUTION
WAR NI NG
CAUTION
CAUTION
WARNING
CAUTION
CAUTION
WARNING
WARNING
CAUTION
CAUTION
CAUTION
WAR NI NG
CAUTION
CAUTION
CAUTION
GT2512
1)2)
5)
22)
17)7)16)
8)
9)
10)
11)
12)
13)
14)
21)20) 19)
6) 6)
6) 6)
3)4)
15)
18)
GT2512-STBA GT2510-VTBD GT2508-VTBD
Thank you for purchasing the GOT2000 Series.
Prior to use, please read both this manual and the detailed manual thoroughly to fully understand the product.
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this prod­uct. In this manual, the safety precautions are ranked as "WARNING" and "CAUTION".
Note that the CAUTION level may lead to a serious accident according to the circumstances. Always follow the instructions of both levels because they are impor­tant to personal safety. Please save this manual to make it accessible when required and always forward it to the end user.
[DESIGN PRECAUTIONS]
Some failures of the GOT, communication unit or cable may keep the outputs
on or off. Some failures of a touch panel may cause malf unction of the input objects such as a touch switch. An external monitoring circuit should be provided to check for output signals which may lead to a serious accident. Not doing so can cause an accident due to false outp ut or malfunction.
Do not use the GOT as the warning device that may cause a ser ious
accident. An independent and redundant hardware or mechanic al interlock is required to configure the device that displays and outputs se rious warning. Failure to observe this instruction may result in an accident due to incorrect output or malfunction.
The GOT backlight failure disables the operation on the touch s witch(s).
When the GOT backlight has a fail ure, the POWER LED blinks (orange/blue) and the display section dims. In such a case, the input by the touch switch(s) is disabled.
The display section of the GOT is an analog-resisti ve type touch panel.
When multiple points of the display section are touche d simultaneously, an accident may occur due to incorrect output or ma lfunction. Do not touch the display section in 2 points or more simultaneously. If you touch the display section simultaneously in 2 points or mor e, the switch that is located around the center of the touched poin t, if any, may operate. Doing so may cause an accident due to incorrect ou tput or malfunction.
When programs or parameters of the controller (such as a PLC) that is
monitored by the GOT are changed, be sure to reset the GO T, or turn on the unit again after shutting off the power as soon as possible. Not doing so can cause an accident due to false outp ut or malfunction.
If a communication fault (including cable disconnection) occ urs during
monitoring on the GOT, communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative. For bus connection : The CPU becomes faulty and the GOT becomes inoperative. For other than bus connection : The GOT becom es inoperative. A system where the GOT is used should be confi gured to perform any significant operation to the system by using the switc hes of a device other than the GOT on the assumption that a GOT communi cation fault will occur. Not doing so can cause an accident due to false outp ut or malfunction.
GT2512-STBD GT2510-VTWD GT2508-VTWD
GT2510-VTBA GT2508-VTBA
MODEL GT25-U-GD-E
Model
code
1D7MN4
IB(NA)-0800537ENG-B(1410)MEE
SAFETY PRECAUTIONS
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
1
2
3
Products with the Cl.I, DIV.2 mark on the rating plate are suitable for use in
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
Class I, Division 2, Groups A, B, C and D hazardous locations, or nonhazardous locations only. This mark indicates that the product is certifie d for use in the Class I, Division2 environment where flammable gase s, vapors, or liquids are not likely to exist under normal conditions. When using the products in the Class I, Division 2 e nvironment, observe the following to reduce the risk of explosion.
• This device is open-type and is to be install ed in an enclosure suitable for the environment and require a tool or key to open.
• Warning - Explosion Hazard - Substitution of any com ponent may impair suitability for Class I, Division 2.
• Warning - Explosion Hazard - Do not disconnect equipment unle ss power has been removed or the area is known to be non- hazardous.
• The side interface and extension interface of this equipment cann ot be used in Class I, Division 2 environments.
Les produits marqués Cl.I, DIV.2 sur la plaque signalétique peuvent être utilisés en Class I, Division 2, local dangereux de groupe A, B, C et D, ou uniquement en local non dangereux. Ce logo indique que le produit est homologué pour utilisation en environnement de Class I, Division 2 où, dans des circonstances anormales, il peut y avoir présence de gaz, vapeurs ou liquides inflammables. Si le produit est utilisé en environnement de Clas s I, Division 2, observer les précautions suivantes pour réduire le risque d 'explosion.
Cet appareil est de type ouvert et il doit être installé dans une enceinte appropriée à l'environnement et ne pouvant être o uverte qu'au moyen d'une clé ou d'un outil.
Avertissement - Danger d'explosion - Toute substitution de composant peut compromettre l'aptitude à l'utilisation en Cla ss I, Division 2.
Avertissement - Danger d'explosion - Ne pas déconnecter l'équipement quand le circuit est sous tension, ni avant de d'êtr e assuré de l'absence d'atmosphère inflammable.
L’interface latérale et l’interface d’extension de cet équipemen t ne peuvent être utilisées dans les environnements de Classe I, Division 2.
Do not bundle the control and communication cables with main-circui t, power
or other wiring. Run the above cables separately from such wiring and kee p them a minimum of 100mm apart. Not doing so noise can cause a malfunction.
Do not press the GOT display section with a pointed material a s a pen or
driver. Doing so can result in a damage or failure of the dis play section.
When the GOT is connected to the Ethernet network, the available IP
address is restricted according to the system configuration.
• When multiple GOTs are connected to the Ethernet network : Do not set the IP address (192.168.3.18) for the GOTs and the controllers in the network.
• When a single GOT is connected to the Ethernet n etwork : Do not set the IP address (192.168.3.18 ) for the controllers except the GOT in the network. Doing so can cause the IP address duplication. The duplication can negatively affect the communication of the device with th e IP address (192.168.3.18). The operation at the IP address duplication depe nds on the devices and the system.
Turn on the controllers and the network devices to be ready for
communication before they communicate with the GOT. Failure to do so can cause a communication error on the GOT.
When the GOT is subject to shock or vibration, or some colors appear on the
screen of the GOT, the screen of the GOT might flicker.
[MOUNTING PRECAUTIONS]
Be sure to shut off all phases of the external power supply used by the
system before mounting or removing the GOT main un it to/from the panel. Not doing so can cause the unit to fail or malfunction.
Be sure to shut off all phases of the external power supply used by the
system before mounting or removing the option unit o nto/from the GOT.
Use the GOT in the environment that satisfies the general speci fications
described in this manual. Not doing so can cause an electric shock, fire, mal function or product damage or deterioration.
When mounting the GOT to the control panel, tighten the mounting screws in
the specified torque range (0.36 N•m to 0.48 N• m) with a Phillips-head screwdriver No.2. Undertightening can cause the GOT to drop, short circuit or malfunction. Overtightening can cause a drop, short circuit or malf unction due to the damage of the screws or the GOT.
When mounting a unit on the GOT, tighten the mounting screws in the
following specified torque range. When loading the communication unit or option unit other than wireless LAN unit to the GOT, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range (0 .36 N•m to 0.48 N•m) with a Phillips-head screwdriver No.2. When loading the wireless LAN unit to the GOT, fit it to the side interface of GOT and tighten the mounting screws in the specif ied torque range (0.10 N•m to 0.14 N•m) with a Phillips-head screwdriver No.1. When the GOT is installed vertically, its side interface is positioned o n the bottom.To prevent the falling of the wireless LAN communication unit from the side interface, install or remove the unit while holding it with hands. Under tightening can cause the GOT to drop, short circuit or malfunction. Overtightening can cause a drop, failure or malfu nction due to the damage of the screws or unit.
When closing the USB environmental protection cover, fix the cover to the
GOT by pushing the [PUSH] mark on the latch firmly to comply with the protective structure.
Remove the protective film of the GOT.
When the user continues using the GOT with the protective film, the film may not be removed.
Operate and store the GOT in environments without direct sunlig ht, high
temperature, dust, humidity, and vibrations.
When using the GOT in the environment of oil or chemicals, u se the
protective cover for oil.Failure to do so may cause failure or malfunction due to the oil or chemical entering into the GOT.
[WIRING PRECAUTIONS]
Be sure to shut off all phases of the external power supply used by the
system before wiring. Failure to do so may result in an electric shoc k, product damage or malfunctions.
Make sure to ground the FG terminal and LG terminal of the GOT p ower
supply section to the protective ground conductors de dicated to the GOT with a ground resistance of 100 or less.
When tightening the terminal screws, use a Phillips-head screwd river No.2. Terminal screws which are not to be used must be tightened always at torque
0.5 N•m to 0.8 N•m. Otherwise there will be a danger of short circuit agai nst the solderless terminals.
Use applicable solderless terminals and tighten them with the specified
torque. If any solderless spade terminal is used, i t may be disconnected when the terminal screw comes loose, resulting in failu re.
Correctly wire the GOT power supply section after confirming the rated
voltage and terminal arrangement of the product. Not doing so can cause a fire or failure
[WIRING PRECAUTIONS]
Tighten the terminal screws of the GOT power supply section i n the specified
torque range (0.5 N•m to 0.8 N•m). Undertighten ing can cause a short circuit or malfunction.Overtightening can cause a short circu it or malfunction due to the damage of the screws or the GOT.
Exercise care to avoid foreign matter such as chips and wire offcuts entering
the GOT. Not doing so can cause a fire, failure or malfunction.
The module has an ingress prevention label on its top to preven t foreign
matter, such as wire offcuts, from entering the module during wiring. Do not peel this label during wiring.Before starting system operation, be sure to peel this label because of heat dissipation.
Plug the communication cable into the GOT interface or the connecto r of the
connected unit, and tighten the mounting screws and the terminal screws in the specified torque range.Undertightening ca n cause a short circuit or malfunction.Overtightening can cause a short c ircuit or malfunction due to the damage of the screws or unit.
Plug the QnA/ACPU/Motion controller(A series) bus connec tion cable by
inserting it into the connector of the connected u nit until it "clicks". After plugging, check that it has been inserted snug ly. Not doing so can cause a malfunction due to a contact faul t.
[TEST OPERATION PRECAUTIONS]
Before performing the test operations of the user creation monito r screen
(such as turning ON or OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter, and changing the buffer memory current value), read through th e manual carefully and make yourself familiar with the oper ation method. During test operation, never change the data of the devices which are used to perform significant operation for the system. False output or malfunction can cause an accident.
[STARTUP/MAINTENANCE PRECAUTIONS]
When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfuncti on.
Correctly connect the battery connector.Do not charge, disassemble, heat,
short-circuit, solder, or throw the battery into the fire.Doing so will cause the battery to produce heat, explode, or ignite, resulti ng in injury and fire.
Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases.Not switching the p ower off in all phases can cause a unit failure or malfunction.Undertighten ing can cause a short circuit or malfunction.Overtightening can cause a short circu it or malfunction due to the damage of the screws or unit.
Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunct ion due to a cable connection fault.
When unplugging the cable connected to the unit, do not hold and pul l from
the cable portion.Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection faul t.
Do not drop the module or subject it to strong shock. A module damage ma y
result.
Do not drop or give an impact to the battery mounted to the unit.
Doing so may damage the battery, causing the battery fluid to leak inside the battery.If the battery is dropped or given an impact, dispose of it without using.
Before touching the unit, always touch grounded metals, etc. to dis charge
static electricity from human body, etc. Not doing so can cause the unit to fail or malfunction.
Use the battery manufactured by Mitsubishi Electric Corporation.
Use of other batteries may cause a risk of fire or expl osion.
Dispose of used battery promptly.
Keep away from children.Do not disassemble and do not dispose of in fire.
Be sure to shut off all phases of the external power supply before r eplacing
the battery or using the dip switch of the te rminating resistor.Not doing so can cause the unit to fail or malfunction by static electricity.
[TOUCH PANEL PRECAUTIONS]
For the analog-resistive film type touch panels, normally the adjustment is not
required. However, the difference between a touched position and the object position may occur as the period of use elapses. When any difference between a touched position and the object position occurs, execute the touch panel calibration.
When any difference between a touched position and the object pos ition
occurs, other object may be activated. This may cause an unexpected operation due to incorrect output or malfunction.
[PRECAUTIONS WHEN THE DATA STORAGE IS IN USE]
If the SD card is removed from drive A of the GOT while being a ccessed by
the GOT, the GOT may stop processing data for about 20 seconds.The GOT cannot be operated during this period. The function s that run in the background including a screen updating, alarm, l ogging, scripts, and others are also interrupted.Since this interruption makes an impact to the system operation, it might cause failure.After checking th e light off of SD card access LED, remove the SD card.
If the data storage is removed from the GOT while being accessed by th e
GOT, the data storage and files may be damaged.Before removing the data storage from the GOT, check the SD card access LED, system signal, or others to make sure that the data storage is not accessed.
When inserting a SD card into the GOT, make sure to close the SD card
cover. Failure to do so causes the data not to be read or written.
When removing the SD card from the GOT, make sure to support the SD card
by hand as it may pop out.Failure to do so may c ause the SD card to drop from the GOT, resulting in a failure or break.
When inserting a USB device into a USB interface of the GO T, make sure to
insert the device into the interface firmly.Failure to do so may cause the USB device to drop from the GOT, resulting in a failure or break
Before removing the USB device from the GOT, follow the procedure for
removal on the utility screen of the GOT. After the successful completion dialog is displayed, remove the USB dev ice by hand carefully.Failure to do so may cause the USB device to drop from the GO T, resulting in a failure or break.
[DISPOSAL PRECAUTIONS]
When disposing of this product, treat it as industrial waste .
When disposing of batteries, separate them from other wastes according to the local regulations. (Refer to the GOT2000 Series User’s Manual (Hardware) for details of the battery directive in the EU member states.)
[TRANSPORTATION PRECAUTIONS]
When transporting lithium batteries, make sure to treat them based on the
transport regulations. (Refer to the GOT2000 Series User’s Manual (Ha rdware) for details of the regulated models.)
Make sure to transport the GOT main unit and/or relevant unit(s ) in the
manner they will not be exposed to the impact exceedin g the impact resistance described in the general specifications of this manual, as they are precision devices. Failure to do so may cause the unit to fail. Check if the unit operates correctly after transportation.
When fumigants that contain halogen materials such as fluorine, chlori ne,
bromine, and iodine are used for disinfecting and p rotecting wooden packaging from insects, they cause malfunction when ent ering our products. Please take necessary precautions to ensure that rem aining materials from fumigant do not enter our products, or treat packaging with methods oth er than fumigation (heat method). Additionally, disinfect and protect wood from insects before packing products.
The following shows manuals relevant to this product.
Manual
Detailed Manual
Manual name
GOT2000 Series User’s Manual (Hardware)
GOT2000 Series User’s Manual (Utility)
For detailed manuals, refer to the PDF manuals stored in the DVD-ROM for the drawing software used.
Manual number
(Model code)
SH-081194ENG
(1D7MJ5)
SH-081195ENG
(1D7MJ6)
Relevant Manuals
For relevant manuals, refer to the Help or the PDF m anuals stored in the DVD­ROM for the drawing software used.
The latest manuals are also available from MITS UBISHI ELECTRIC FA Global Website (http://www.MitsubishiElectric.co.jp/fa/).
© 2014MITSUBISHI ELECTRIC CORPORATION
Before using the GOT
Connect the connector of the GOT to the connector of t he battery. Refer to the GOT2000 Series User’s Ma nual (Hardware) for the connection instructions.
For details on the GOT specifications, installing ins tructions, wiring, maintenance and inspection, or checking procedure for the versi on and the compatible standard, refer to the GOT2000 Series User’s Manual (Hardwa re).
Packing List
The GOT product package includes the following:
Battery (GT11-50BAT) (Attached to the GOT) 1
Description Quantity
GT25 1
Installation fitting 4
GT25 General Description (This manual) 1
GT25 本体概要説明書
1. FEATURES
(1) Abundant standard equipment
• Variety of connection with FA devices
• SD card interface compatible with the S DHC card having a large capacity and allowing high-speed communication
• Connection with va rious peripheral devices with the USB host
(2) Improved usability
• Abundant troublesho oting
• Easy and clear s creen creation
• PC-like operation s creen
• Support for the v ertical installation
(3) Enhanced compatibility with Mitsubishi FA devices (4) Easy replacement] (5) LED backlight (6) Various extended functions supported
2. Part Names and Settings
The following shows the part names for GT2512, GT2510 a nd GT2508.
GT2510
1)2)
6) 6)
18)
3)4)
6)6)17)
22)21)20) 19)
23)
7)
GT2508
5)
1)2)
6) 6)
18)
3)4)
6) 6)17)
22)21)20) 19)
23)
15)
No. Name Description
1) Display screen Displays the utility and the user-created screen.
2) Touch Pane
USB interface
3) (Host/Front face)
USB interface (Device
4) /Front face)
5) POWER LED
6) Unit installation fitting Mounting fixtures for fixing the GOT to the control panel
1
7) Reset switch Hardware reset switch
8) Installation switch Used for OS installations at the GOT startup
9) SD card access LED
10) SD card interface For installing a SD card
11) SD card cover
12) Battery holder Houses the battery
13) Side interface For installing a communic ation unit
USB interface
14) (Host/Back face)
Hole for attaching a
15) cable clamp
Terminating resistor
16)
setting switch (Inside cover)
17) Extension interface For installing a communic ation unit or an option unit Vertical installation
18) arrow mark
19) Power terminal Power input terminal, LG terminal, FG terminal
20) Ethernet interface
21) RS-232 interface
22) RS-422/485 interface
USB interface (Device/
23) Back face)
For operating the touch switches in the utility and the user­created screen
For connecting a USB mou se, connecting a USB keyboard, data transfer, and data storage (connector type: TYPE-A) (Only GT2512-STBA/D, GT2510-VTBA/D VTBA/D)
For connecting a personal computer (connector type: Mini­B) (Only GT2512-STBA/D, GT2510-VTBA/D VTBA/D)
Lit in blue : Power is properly supplied. Lit in orange : Screen saving Blinks in orange/blu e : Backlight failure Not lit : Power is not supplied
Lit: SD card mounted Blinking: SC card accessed No lit: SD card not mounted or SD card mounted (removable)
With a switching function for accepting and stopping the access to the SD card When the cover is opened : Acc ess is prohibited When the cover is closed : Access is allowed
For connecting a USB mou se, connecting a USB keyboard, data transfer, and data storage (connector type: TYPE-A)
Hole for attaching a cab le clamp for preventing USB cable from being pulled out (Recommended product: RSG-1 30-V0 made by KITAGAWA INDUSTRIES CO.,LTD)
For switching on and off of the terminating resistor for the RS-422/485 communication port (Default (Off))
For the vertical installation, install the GOT so that the arrow points upward.
For communicating with a co ntroller or connecting a personal computer (conne ctor type: RJ-45 (modular jack))
For communicating with a controller (Connector type: D s ub 9-pin (male))
For communicating with a controller (Connector type: D s ub 9-pin (female))
For connecting personal co mputers (connector type: Mini-B) (Only GT2510-VTWA/D, GT2508-VTWA/D)
16)
7)
16)
8)
9)
10)11)12)
13)
14)
and GT2508-
and GT2508-
8)
9)
10)
11)
12)
13)
14)
15)
3. Specifications
3.1 General Specifications
Item Specifications
Operating ambient
*1
temperature
Température ambiante de fonctionnement
Storage ambient temperature
Operating ambient humidity
Storage ambient humidity
Vibration resistance
Shock resistance
Operating atmosphere
Operating altitude Installation location Inside control panel Overvoltage
category Pollution degree Cooling method Self-cooling
Grounding
*1: The operating ambient temperature incl udes the temperature inside the
*2: When mounting a MELSECNET/H communic ation unit (GT15-J71LP23-25,
*3: Do not use or store the GOT under pr essure higher than the atmospheric
*4: This indicates the section of the power supply to which the equipment is
*5: This index indicates the degree to which conductive material is generated in the
*1
10 to 90% RH, non-condensing
10 to 90% RH, non-condensing
Complian t with JIS
B 3502 and IEC 61131-2
Compliant with JIS B 3502 and IEC 61131-2 147 m/s
No greasy fumes, corrosive gas, flammable gas, excessive
conductive dust, and dire ct sunlight (Same as storage atmosphere)
*3
*4
*5
enclosure of the control panel to which the GOT is installed.
La température ambiante de fonctionnement inclut la te mpérature à l'intérieur du boîtier du tableau de commande sur lequel le GOT est installé.
GT15-J71BR13), or CC-Link communication unit (GT1 5-J61BT13), the operating ambient temperature must be reduced values described in general specifications.
Lors du montage d'un module communication MELSECNET/H (GT15­J71LP23-25, GT15-J71BR13) ou du module de communication CC-Link (GT15-J61BT13), la température ambiante de fonctionnem ent doit être réduite de 5 par rapport aux valeurs maximales décrites dans les spécifications générales.
pressure of altitude 0m (0ft.). Failure to observe this instruction may c ause a malfunction. When an air purge is made inside the control panel by adding pressure, there may be a clearance between the surface sheet and the screen making it difficult to use the touch panel, or the sheet may come off.
assumed to be connected between the public electric al power distribution network and the machinery within the premises. Category II applies to equipment for which electrical powe r is supplied from fixed facilities. The surge voltage withstand level for up to the rated voltage of 300 V is 2500 V.
environment where the equipment is used. In pollution degree 2, only non-conductive pollu tion occurs but temporary conductivity may be produced due to condensa tion.
Point
Refer to the GOT2000 Series User’s Manual (Hardware) for details on the performance specifications of each GOT.
Frequency Acceleration
Under
intermitten
t vibration
Under
continuou
8.4
s vibration
3 times each in X, Y and Z direct ions
Type D grounding (100 or l ess).
Connect to panel if unable to ground.
*2
0 to 55
*2
0 à 55
-20 to 60
5 to 8.4Hz
8.4
5 to 8.4Hz
2000 m (6562 ft) max.
-
to150Hz
9.8m/s
-
to 150Hz
4.9m/s
II or less
2 or less
5 against the maximum
2
2
Half-
amplitude
3.5mm
-
1.75mm
-
Sweep
10 times
each in X,
Y and Z
directions
2
(15G),
count
-
3.2 Power Supply Specifications
The following indicates the power supply s pecifications for GT25.
Note
Operation at momentary failure
• If an instantaneous power failure occurs in the power supply and continues for more than the permissible period, the GOT will be reset.
• Make sure to power on the unit more than 5 seconds after power-off.
3.2.1 For GOTs powered from the 100 to 240VAC power supply
Item
Power supply voltage Power supply voltage AC100 to 240VAC (+10%, -15%) Power frequency 50/60Hz 5% Max. apparent power 80VA 80VA 70VA
maximum load 35W or less 34W or less 31W or less
Power
Stand alone 14W 12W 11W
consum
Stand alone with
ption
backlight off
Inrush current
Allowable momentary power failure time
Noise immunity
Dielectric wit hstand voltage 1500VAC for 1 minute across po wer terminals and earth
Insulation resistance
Applicable wire size 0.75[mm
Applicable solderless terminal
Applicable tightening torque (Terminal block terminal screw)
GT2512-STBA
60A or less (2ms, operating ambient temperature 25,
1,500Vp-p noise voltag e, 1 s noise width (when measuring with a noise si mulator under 25 to 60Hz noise frequency)
10M or more across powe r terminals and earth by a 500V DC insulation resistance te ster
Solderless terminal for M3 screw RAV1.25-3, V2-S3.3,
Specifications
GT2510-VTBA, GT2510-VTWA
7W 7W 7W
maximum load)
20 ms or less (100VAC or more)
V2-N3A, FV2-N3A
0.5[N•m] to 0.8[N•m]
2
] to 2[mm2]
GT2508-VTBA, GT2508-VTWA
3.2.2 For GOTs powered from the 24VDC power supply
Item
Power supply voltage DC24V (+25%, -20%)
maximum load 37W or less 33W or less 31W or less
Power
Stand alone 13W 10W 8W
consum
Stand alone with
ption
backlight off
Inrush current
Allowable momentary power failure time
Noise immunity
Dielectric withstand voltage 350VAC for 1 minute across power terminals and earth
Insulation resistance
Applicable wire size 0.75[mm
Applicable solderless terminal
Applicable tightening torque (Terminal block terminal screw)
GT2512-STBD
5A or less (20ms, operati ng ambient temperature 25,
500Vp-p noise voltage, 1 s noise width (when measuring with a noise si mulator under 25 to 60Hz noise frequency)
10M or more across powe r terminals and earth by a 500V DC insulation resistance te ster
Solderless terminal for M3 screw RAV1.25-3, V2-S3.3,
Specifications
GT2510-VTBD, GT2510-VTWD
6W 6W
maximum load)
10 ms or less
V2-N3A, FV2-N3A
0.5[N•m] to 0.8[N•m]
2
] to 2[mm2]
GT2508-VTBD, GT2508-VTWD
3.3 External Dimensions
GT2512
10
(0.39)
227 (8.94)
10
(0.39)
GT2508
10
(0.39)
175 (6.89)
10
(0.39)
52
52
6
(2.05)
6
(2.05)
246 (9.69)
(0.24)
241 (9.49) 166 (6.54)
194 (7.64)
(0.24)
226 (8.90)
316 (12.44)
241 (9.49)
241 (9.49)
301 (11.85)
171.6 (6.76)
GT2510
10
199 (7.83)
10
37.5
(1.48)
37.5
(1.48)
Unit : mm (inch)
(0.39)
(0.39)
52
218 (8.58)
6
(0.24)
(2.05)
303 (11.93)
208 (8.19)
228 (8.98)
288 (11.34)
4. EMC AND LOW VOLTAGE DIRECTIVE
Unité : mm (pouce)
*Épaisseur du panneau : 1,6 à 4mm (0,06 à 0,16 pouce)
GOT
A
B
GT
2510
GT
2508
289 (11.38)
227 (8.94)
+2 (0.08) 0 (0)
+2 (0.08) 0 (0)
200 (7.87)
176 (6.93)
+2 (0.08) 0 (0)
+2 (0.08) 0 (0)
GT
2512
302 (11.89)
+2 (0.08) 0 (0)
228 (8.98)
+2 (0.08) 0 (0)
B
B
Horizontal
Vertical
A
C
C
C
C
A
C
10 (0.39) ou plus
For the products sold in European countries, the conformance to the EMC Directive, which is one of the European Directives, has been a legal obligation since 1996. Also, conformance to the Low Voltage. Directive, another European Directives, has been a legal obligation since
1997. Manufacturers who recognize their products must conform to the EMC and Low Voltage Directive are required to declare that their products conform to these Directives and put a "CE mark" on their products.
• Authorized representative in Europe Authorized representative in Europe is shown below. Name :Mitsubishi Elec tric Europe BV Address :Gothaer strase 8, 40880 Ratingen, Germany
4.1 Requirements to Meet EMC Directive
EMC Directives are those which require "any strong electromagnetic force is not output to the external.:Emission (electromagnetic interference)" and "It is not influenced by the electromagnetic wave from the external.: Immunity (electromagnetic sensitivity)". Items4.1.1 through4.1.3 summarize the precautions to use GOT and configure the mechanical unit in order to match the EMC directives. Though the data described herein are produced with our best on the basis of the requirement items and standards of the restrictions gathered
by Mitsubishi, they do not completely guaranteed that all mechanical unit manufactured according to the data do not always match the above.
4.1.1 EMC directive
The standards of the EMC Directive are shown below.
Applied
standard
EN61131-2 : 2007
*1: The GOT is an open type device (device ins talled to another device) and must
*2: QP (Quasi-Peak): Quasi-peak value, Mean: Average value
Test standard Test details Standard value
Electromagnetic
*1
*1
emissions from the
*1
product are measured.
Electromagnetic emissions from the
*1
product to the power line is measured.
Immunity test in which static electricity is applied to the cabinet of the equipment.
Immunity test in which field is irradiated to the product.
Immunity test in which burst noise is applied to the power line and signal lines.
Immunity test in which lightening
*1
surge is applied to the product.
Immunity test in which a noise inducted on the power and signal lines is applied. Test for checking normal operations under the circumstance exposed to the ferromagnetic field noise of the power supply frequency (50/60Hz).
Test for checking normal operations at instantaneous power failure.
CISPR16-2-3 Radiated noise
CISPR16-2-1 Conducted noise
IEC61000-4-2 Electrostatic immunity
IEC61000-4-3 Radiated electromagnetic field AM modulation
IEC61000-4-4 Fast transient burst
*1
noise
IEC61000-4-5 Surge immunity
IEC61000-4-6 Conducted RF immunity
IEC61000-4-8 Power supply frequency magnetic field immunity
IEC61000-4-11 Instantaneous power failure and voltage dips immunity
be installed in a conductive control panel. The above test items are conducted in the condition where the GOT is installed on the conductive control panel and combined with the Mitsubishi PLC.
30M-230MHz QP: 30dB V/m (30m in measurement range) 230M-1000MHz QP: 37dB V/m(30m in measurement range)
150k-500kHz QP:79dB, Mean: 66dB 500k-30MHz QP:73dB, Mean: 60dB
4kV Contact discharge 8kV Aerial discharge
80-1000MHz:10V/m
1.4-2GHz:3V/m
2.0-2.7GHz:1V/m 80%AM modulation@1kHz Power line:2kV Digital I/O(24V or high er): 1kV (Digital I/O(24V or less))> 250V (Analog I/O, signal lines)> 250V AC power type
Power line (between line and ground): 2kV Power line (between lines) : 1kV Data communication port : 1kV
DC power type
Power line (between line and ground) : 0.5kV
Power line (between lines)
: 0.5kV
Data communication port
: 1kV
Power line: 10V Data communication port: 1 0V
30 A/m
AC power type
0.5 cycle 0% (interval 1 to 10s) 250/300 cycle 0% 10/12 cycle 40% 25/30 cycle 70%
*2, *3
*2, *3
*2
*2
*3: The above test items are conducted in the foll owing conditions.
30M-230MHz QP : 40dB V/m (10m in measurement range) 230M-1000MHz QP : 47dB V/m (10m in measurement range)
4.1.2 Control panel
The GOT is an open type device (device installed to another device) and must be installed in a conductive control panel. It not only assure the safety but also has a large effect to shut down the noise generated from GOT, on the control panel. (1) Control Panel
(a) The control panel must be conductive. (b) When fixing a top or bottom plate of the control panel wit h bolts,
do not coat the plate and bolt surfaces so that they will come into contact. And connect the door and box using a thick grounding cable in order to ensure the low impedance under high frequency.
(c) When using an inner plate to ensure electric conductivity with the
control panel, do not coat the fixing bolt area of the inner plate and control panel to ensure conductivity in the largest area as possible.
(d) Ground the control panel using a thick grounding cable in order to
ensure the low impedance under high frequency.
(e) The diameter of cable holes in the control panel must be 10cm
(3.94in.). In order to reduce the chance of radio waves leaking out, ensure that the space between the control panel and its door is small as possible. Paste the EMI gasket directly on the painted surface to seal the space so that the leak of electric wave can be suppressed. Our test has been carried out on a panel having the damping characteristics of 37dB max. and 30dB mean (measured by 3m method with 30 to 300MHz).
(2) Connection of power and ground wires
Ground and power supply wires for the GOT must be connected as described below. (a) Provide a grounding point near the GOT. Short-circuit the LG and
FG terminals of the GOT (LG: line ground, FG: frame ground) and ground them with the thickest and shortest wire possible (The wire length must be 30cm (11.81in.) or shorter.) The LG and FG terminals function is to pass the noise generated in the PC system to the ground, so an impedance that is as low as possible must be ensured. As the wires are used to relieve the noise, the wire itself carries a large noise content and thus short wiring means that the wire is prevented from acting as an antenna. Note) A long conductor will become a more efficient antenna at high frequency.
(b) The earth wire led from the earthing point must be twisted with
the power supply wires. By twisting with the earthing wire, noise flowing from the power supply wires can be relieved to the earthing. However, if a filter is installed on the power supply wires, the wires and the earthing wire may not need to be twisted.
4.1.3 Noise filter (power supply line filter)
The noise filter (power supply line filter) is a device effective to reduce conducted noise. Except some models, installation of a noise filter onto the power supply lines is not necessary. However conducted noise can be reduced if it is installed. (The noise filter is generally effective for reducing conducted noise in the band of 10MHz or less.) Usage of the following filters is recommended.
Model name FN343-3/05 FN660-6/06 RSHN-2003
Manufacturer SCHAFFNER SCHAFFNER TDK
Rated current 3A 6A 3A
Rated voltage 250V
The precautions required when installing a noise filter are described below.
(1) Do not install the input and output cables of the noise filter together
to prevent the output side noise will be inducted into the input side cable where noise has been eliminated by the noise filer.
Input side
(power supply side)
Filter
• I nstalling the input and output cables together will cause noise induction.
(2) Connect the noise filter's ground terminal to the control panel with
the shortest cable as possible (approx. 10cm (3.94 in.) or less).
Induction
Output side
(device side)
Input side
(power supply side)
Filter
Output side
(device side)
• Separate the input cable from the output cable.
4.2 Requirements for Compliance with the Low Voltage Directive
The Low Voltage Directive requires each device which operates with power supply ranging from 50VAC to 1000V and 75VDC to 1500V to satisfy necessary safety items. In the Sections from 4.2.1 to 4.2.5, cautions on installation and wiring of the GOT to conform to the Low Voltage Directive requires are described. We have put the maximum effort to develop this material based on the requirements and standards of the Directive that we have collected. However, compatibility of the devices which are fabricated according to the contents of this manual to the above Directive is not guaranteed. Each manufacturer who fabricates such device should make the final judgement about the application method of the Low Voltage Directive and the product compatibility.
4.2.1 Standard subject to GOT
Standard applied to GOT : EN61131-2 Programmable controllers - Equipment
requirements and tests
EN60950-1 Safety of In formation Technology Equipment
4.2.2 Power supply
The insulation specification of the GOT was designed assuming installation category II. Be sure to use the installation category II power supply to the GOT. The installation category indicates the durability level against surge voltage generated by lightning strike. Category I has the lowest durability; category IV has the highest durability.
Category ICategory IICategory IIICategory IV
Category II indicates a power supply whose voltage has been reduced by two or more levels of isolating transformers from the public power distribution.
Installation category
4.2.3 Control panel
Because the GOT is open type equipment (device designed to be stored within another device), be sure to use it only when installed in a control panel.
(1) Shock Protection
In order to prevent those who are unfamiliar with power facility, e.g., an operator, from getting a shock, make sure to take the following measures on the control panel. (a) Store the GOT within the control panel locked, and allow only
those who are familiar with power facility to unlock the panel.
(b) Build the structure in order that the power supply will be shut off
when the control panel is opened.
(2) Dustproof and waterproof features
The control panel also provides protection from dust, water and other substances. Insufficient ingression protection may lower the insulation withstand voltage, resulting in insulation destruction. The insulation in the GOT is designed to cope with the pollution level 2, so use in an environment with pollustion level 2 or better.
Pollution level 1: An env ironment where the air is dry and conductive
Pollution level 2: An env ironment where conductive dust does not
Pollution level 3: An environment where conductive dust exits and
Pollution level 4: Continuo us conductivity may occur due to rain, snow,
dust does not exist.
usually exist, but occasional temporary condu ctivity occurs due to the accumulated dust. Generally, this is the level for inside the control panel equivalent a control room or on the floor of a typical factory.
conductivity may be generated due to t he accumulated dust. An environment for a typical factory floor.
etc. An outdoor environment.
4.2.4 Grounding
The following are applicable ground terminals. Use them in the grounded state. Be sure to ground the GOT for ensuring the safety and complying with the EMC Directive.
Functional grounding : Improves the noise resistance.
4.2.5 External wiring
(1) External devices
When a device with a hazardous voltage circuit is externally connected to the GOT, select a model which complies with the Low Voltage Directive's requirements for isolation between the primary and secondary circuits.
(2) Insulation requirements
Dielectric withstand voltages are shown in the following table. Reinforced Insulation Withstand Voltage (Installation Category II, source : IEC664)
Rated voltage of hazardous
voltage area
150 VAC or below 2 500V
300 VAC or below 4000V
Surge withstand voltage (1.2/50 s)
5. INSTALLATION
5.1 Control Panel Inside Dimensions for Mounting GOT
Install the GOT on the control panel out of the way for the equipment inside the control panel. Do not install the GOT and the unit in prohibited areas for the installation.
Point
Applicable cable Some cables may need to be longer than the specified dimensions when connecting to the GOT. Therefore, consider the connector dimensions and bending radius of the cable as well for installation.
5.2 Panel Cutting Dimensions
C
A
B
C
B
C
Horizontal
Vertical
5.3 Mounting Position
When mounting the GOT, the following clearances must be maintained from other structures and devices. Some cables may need to be longer than the specified dimensions when connecting to the GOT. Therefore, consider the connector dimensions and bending radius of the cable as well for installation. For the lead-in allowance for cables at the bottom of the GOT, refer to the GOT2000 Series User’s Manual (Hardware) . For the vertical installation, install the GOT so that the vertical installation arrow printed on the GOT rear face points upward.
B
A
Horizontal
DE
Panel thickness:
1.6 to 4mm
C
(0.06 to 0.16 inch)
According to the dimensions in the following table, leave clearances between the GOT and the other devices. The values enclosed in square brackets apply to the case where no other equipment generating radiated noise (such as a contactor) or heat is installed near the GOT. However, keep the ambient temperature of the GOT to 55°C or lower.
*Panel thickness : 1.6 to 4 mm (0.06 to 0.16 inch)
GOT A B
C
302 (11.89)
GT
+2 (0.08)
2512
0 (0)
289 (11.38)
GT
+2 (0.08)
A
2510
0 (0)
227 (8.94)
GT
+2 (0.08)
2508
0 (0)
D
B
C
Vertical
(0.06 to 0.16 inch)
228 (8.98)
+2 (0.08) 0 (0)
200 (7.87)
+2 (0.08) 0 (0)
176 (6.93)
+2 (0.08) 0 (0)
Unit: mm (inch)
A
Panel thickness:
1.6 to 4mm
C
10 (0.39) or more
E
more
more]
Unit : mm(inch)
48(1.89) or
more
[29(1.14) or
more]
23(0.91) or
more
[29(1.14) or
more]
67(2.64) or
more
50(1.97)or
more
Item
GOT only
Bus connection unit is fitted
Serial connection unit is fitted
CC-Link communication unit (GT15-J61BT13) fitted
A
MELSECNET/H communica­tion unit (coaxial) fitted
MELSECNET/H communication unit(optical) fitted CC-Link IE Controller Network communication unit fitt ed CC-Link IE Field Network com­munication unit fitted
Printer unit fitted
External I/O unit fitted
Sound output unit fitted
B
When the SD card is used
C
When the SD card is not used
D
*3
E
*1: This value is for use of the coaxial cable 3C-2V (JIS C 3501).
For specifications of the cable, refer to the GOT2000 Series Connection
Manual for a controller used. *2: This value differs depending on the cable used. *3: When opening or closing the battery cover: 72(2 .83) or more
*2
GT2512 GT2510 GT2508
48(1.89) or more
[18(0.71) or more]
48(1.89) or more
[18(0.71) or more]
48(1.89) or more[18(0.71) or more]
48(1.89) or more[18(0.71) or more]
48(1.89) or
*1
more
[38(1.50) or
more]
48(1.89) or more[18(0.71) or more]
48(1.89) or more[18(0.71) or more]
48(1.89) or more[18(0.71) or more]
48(1.89) or more[18(0.71) or more] 48(1.89) or more[18(0.71) or more] 48(1.89) or more[18(0.71) or more]
Horizontal: 78(3.07) or more
Vertical: 48(1.89) or more
50(1.97)or more
[20(0.79) or more]
50(1.97) or more[20(0.79) or more]
Horizontal: 50(1.97) or more
Vertical: 80(3.15) or more
100(3.94) or more[20(0.79) or more]
48(1.89) or
[45(1.77) or
[18(0.71) or more]
[18(0.71) or more]
[20(0.79) or more]
[20(0.79) or more]
5.4 Control Panel Inside Temperature and Installation Angle
When installing the GOT to a panel, set the display section as shown below.Using the GOT with the installation angle other than the following deteriorates the GOT earlier. Installing the GOT horizontally
When installing the GOT with the installation angle between 60 to 105
°, the temperature inside the control panel must be within 55 °C. When installing the GOT with the installation angle other than between 60 to 105 °, the temperature inside the control panel must be within 40 °C.
Installing the GOT vertically
When the GOT is installed a 90° angle , the control panel inside
temperature must be within 55°C. When the GOT is installed at any angle other than 90°, the control panel inside temperature must be within 40°C.
Display section
GOT
Panel or others
Display section
105°
60°
GOT
Panel or others
Horizontal Vertical
5. INSTALLATION
5.1 Dimensions intérieures du tableau de commande pour le montage du GOT
Installez le GOT sur le tableau de commande en laissant de l'espace pour le dispositif à l'intérieur du tableau de commande. N'installez pas le GOT et le module dans des zones où l'installation est interdite.
Point
Câble applicable Certains câbles peuvent être plus longs que les dimensions spécifiées lors de la connexion au GOT. Par conséquent, prenez également en compte les dimensions du connecteur et le rayon de co urbure du câble pour l'installation.
5.2 Cotes de découpe du panneau
5.4 Température intérieure et angle
Lors de l'installation du GOT sur un panneau, réglez la zone d'affichage comme indiqué ci-dessous.
5.3 Position de montage
Lors du montage du GOT, laissez les espaces suivants pour les autres structures et dispositifs.Certains câbles peuvent être plus longs que les dimensions spécifiées lors de la connexion au GOT. Par conséquent, prenez également en compte les dimensions du connecteur et le rayon de courbure du câble pour l'installation. Pour connaître l'espace à laisser pour les câbles sous le GOT, référez­vous au manuel GOT2000 Series User’s Manual (Hardware). Pour l’installation à la verticale, installez le GOT de sorte que la flèche d’installation à la verticale imprimée sur la face arrière du GOT pointe vers le haut.
B
C
Horizontal
Laissez les espaces entre le GOT et les autres dispositifs en fonction des dimensions contenues dans le tableau suivant. Les valeurs entre parenthèses s'appliquent au cas où aucun dispositif générant des émissions sonores (comme un contacteur) ou de la chaleur n'est installé près du GOT. Toutefois, maintenez la température ambiante du GOT à 55°C ou moins.
GOT uniquement
Unité de connexion de bus encastrée
Unité de connexion série encastrée Module de communication CC-
90°
Link (GT15-J61BT13) encastré
Module de communication MELSECNET/H (coaxial)
A
encastré
Module de communication MELSECNET/H (optique) encastré
Module de communication réseau de contrôleur CC-Link I E encastré
Module de communication réseau de champ CC-Link IE encastré
Imprimante encastrée Module d'E/S externe encas tré Module de sortie acoustique
encastré
B
DE
A
Épaisseur du panneau :
(0,06 à 0,16 pouce)
Article
*1
*2
D
B
1,6 à 4mm
GT2512 GT2510 GT2508
48 (1,89) ou plus
[18 (0,71) ou plus]
48 (1,89) ou plus
[18 (0,71) ou plus]
48 (1,89) ou plus[18 (0,71) ou plus]
48 (1,89) ou plus[18 (0,71) ou plus]
48 (1,89) ou
plus
[38(1.50) ou
plus]
48 (1,89) ou plus[18 (0,71) ou plus]
48 (1,89) ou plus[18 (0,71) ou plus]
48 (1,89) ou plus[18 (0,71) ou plus]
48 (1,89) ou plus[18 (0,71) ou plus] 48 (1,89) ou plus[18 (0,71) ou plus]
48 (1,89) ou plus[18 (0,71) ou plus]
Horizontal: 78 (3,07) ou plus
Vertical: 48 (1,89) ou plus
A
C
Vertical
Épaisseur du panneau :
48 (1,89) ou
plus
[45 (1,77) ou
plus]
[18 (0,71) ou plus]
[18 (0,71) ou plus]
E
1,6 à 4mm
(0,06 à 0,16 pouce)
Unité : mm (pouce)
48 (1,89) ou
plus
[29 (1,14) ou
plus]
23 (0,91) ou
plus
[29 (1,14) ou
plus]
67 (2,64) ou
plus
Si l'angle d'installation est différent de celui indiqué, le GOT se détériore plus tôt. Installation du GOT à l’horizontale
Installation du GOT à la verticale
Horizontal Vertical
Refer to the GOT2000 Series User’s Manual (Hardware) for maintenance and inspection for the GOT.
Article
Quand la carte SD est utilis ée
C
Quand la carte SD n'est pas utilisée
D
*3
E
*1 : Cette valeur est utilisée pour le câble coaxial 3C-2V (JIS C 3501).
Pour connaître les spécifications du câble, référez-vous au manuel
GOT2000 Series Connection Manual for a controller used. *2 : Cette valeur diffère selon le câble utilisé. *3 : Pour ouvrir ou fermer le couvercle de la batterie : 72 (2,83) ou plus
d'installation du tableau de commande
Lors de l'installation du GOT avec un angle d'installation compris entre 60 et 105°, la température à l'intérieur du tableau de commande doit être d'environ 55°C. Lors de l'installation du GOT avec un angle d'installation non compris entre 60 et 105°, la température à l'intérieur du tableau de commande doit être d'environ 40°C.
Lors de l’installation du GOT avec un angle de 90°, la température à l’intérieur du panneau de commande ne doit pas dépasser 55°C. Lors de l’installation du GOT avec tout autre angle que 90°, la température à l’intérieur du panneau de commande ne doit pas dépasser 40°C.
Zone d'affichage
GOT
Tableau ou autres
6. MAINTENANCE AND INSPECTION
GT2512 GT2510 GT2508
50 (1,97) ou plus
[20 (0,79) ou plus]
50 (1,97) ou plus[20 (0,79) ou plus]
Horizontal: 50 (1,97) ou plus
[20 (0,79) ou plus]
Vertical: 80 (3,15) ou plus
[20 (0,79) ou plus]
100 (3,94) ou plus[20 (0,79) ou plus]
Zone d'affichage
105°
60°
GOT
Tableau ou autres
50 (1,97) ou
plus
90°
Warra nty
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties.
For safe use
• This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.
• Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
Country/Region Sales office/Tel
U.S.A Mitsubishi Electric Automation Inc. 500 Corporate Woods Parkway Vernon Hills, IL 60061, U.S.A. Tel : +1-847-478-2100 Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda. Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar Paraiso, Sao Paulo, SP Brazil Tel : +55-11-5908-8331 Germany Mitsubishi Electric Europe B.V. German Branch Gothaer Strasse 8 D-40880 Ratingen, GERMANY Tel : +49-2102-486-0 U.K Mitsubishi Electric Europe B.V. UK Branch Travellers Lane, Hatfield, Hertfordshire., AL10 8XB, U.K. Tel : +44-1707-276100 Italy Mitsubishi Electric Europe B.V. Italian Branch Centro Dir. Colleoni, Pal. Perseo-Ingr.2 Via Paracelso 12, I-20041 Agrate Brianza., Milano, Italy Tel : +39-039-60531 Spain Mitsubishi Electric Europe B.V. Spanish Branch Carretera de Rubi 76-80, E-08190 Sant Cugat del Valles, Barcelona, Spain Tel : +34-93-565-3131 France Mitsubishi Electric Europe B.V. French Branch 25, Boulevard des Bouvets, F-92741 Nanterre Cedex, France Tel : +33-1-5568-5568 South Africa Circuit Breaker Industries Ltd. Private Bag 2016, ZA-1600 Isando, South Africa Tel : +27-11-928-2000 Hong Kong Mitsubishi Electric Automation (Hong Kong) Ltd. 10th Floor, Manulife Tower, 169 Electric Road, North Point, Hong Kong Tel : +852-2887-8870 China Mitsubishi Electric Automation (China) Ltd. 4/F Zhi Fu Plazz, No.80 Xin Chang Road, Shanghai 200003, China Tel : +86-21-6120-0808 Taiwan Setsuyo Enterprise Co., Ltd. 6F No.105 Wu-Kung 3rd.Rd, Wu-Ku Hsiang, Taipei Hsine, Taiwan Tel : +886-2-2299-2499 Korea Mitsubishi Electric Automation Korea Co., Ltd. 1480-6, Gayang-dong, Gangseo-ku Seoul 157-200, Korea Tel : +82-2-3660-9552 Singapore Mitsubishi Electric Asia Pte, Ltd. 307 Alexandra Road #05-01/02, Mitsubishi Electric Building, Singapore 159943 Tel : +65-6470-2460 Thailand Mitsubishi Electric Automation (Thailand) Co., Ltd. Bang-Chan Industrial Estate No.111 Moo 4, Serithai Rd, T.Kannayao, A.Kannayao, Bangkok 10230 Thailand Tel : +66-2-517-1326 Indonesia P.T. Autoteknindo Sumber Makmur Muara Karang Selatan, Block A/Utara No.1 Kav. No.11 Kawasan Industri Pergudangan Jakarta - Utara 14440, P.O.Box 5045 Jakarta, 11050 Indonesia Tel : +62-21-6630833 India Messung Systems Pvt, Ltd. Electronic Sadan NO:III Unit No15, M.I.D.C Bhosari, Pune-411026, India Tel : +91-20-2712-3130 Australia Mitsubishi Electric Australia Pty. Ltd. 348 Victoria Road, Rydalmere, N.S.W 2116, Australia Tel : +61-2-9684-7777
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice. Printed in Japan, October 2014.
Loading...