Mitsubishi GT1662-VNBA, GT1675-VNBA, GT1675M-STBD, GT1695M-XTBD, GT1675-VNBD General Description Manual

...
GT16 General Description
WARNING
CAUTION
WAR NI NG
WAR NI NG
CAUTION
WAR NI NG
CAUTION
CAUTION
WARNING
CAUTION
WARNING
WARNING
CAUTION
CAUTION
WAR NI NG
CAUTION
CAUTION
CAUTION
Unit:mm (inch)
397(15.6) 320(12.6)
296(11.7)
320(12.6)
6(0.24)
61(2.40)
10 382(15.0) 10
281(11.1)
(0.39) (0.39)
GT1695
10(0.39)
10(0.39)
GT1695M-XTBA GT1675M-STBA GT1675-VNBA GT1665M-STBA GT1662-VNBA
Thank you for purchasing the GOT1000 Series.
Prior to use, please read both this manual and the detailed manual thoroughly to fully understand the product.
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this prod­uct. In this manual, the safety precautions are ranked as "WARNING" and "CAUTION".
Note that the CAUTION level may lead to a serious accident according to the circumstances. Always follow the instructions of both levels because they are impor­tant to personal safety. Please save this manual to make it accessible when required and always forward it to the end user.
[DESIGN PRECAUTIONS]
Some failures of the GOT, communication unit or cable may keep the outputs
on or off. Some failures of a touch panel may cause malf unction of the input objects such as a touch switch. An external monitoring circuit should be provided to check for output signals which may lead to a serious accident. Not doing so can cause an accident due to false outp ut or malfunction.
If a communication fault (including cable disconnection) occ urs during
monitoring on the GOT, communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative. For bus connection : The CPU becomes faulty and the GOT becomes inoperative. For other than bus connection : The GOT becom es inoperative. A system where the GOT is used should be confi gured to perform any significant operation to the system by using the switc hes of a device other than the GOT on the assumption that a GOT communi cation fault will occur. Not doing so can cause an accident due to false outp ut or malfunction.
Do not use the GOT as the warning device that may cause a ser ious
accident. An independent and redundant hardware or mechanic al interlock is required to configure the device that displays and outputs se rious warning. Failure to observe this instruction may result in an accident due to incorrect output or malfunction.
GT1695M-XTBD GT1675M-STBD GT1675-VNBD GT1665M-STBD GT1662-VNBD
GT1685M-STBA GT1675M-VTBA GT1672-VNBA GT1665M-VTBA GT1655-VTBD
GT1685M-STBD GT1675M-VTBD GT1672-VNBD GT1665M-VTBD
MODEL GT16-U-GD-E
Model
code
1D7MP6
IB(NA)-0800544ENG-A(1410)MEE
SAFETY PRECAUTIONS
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
[DESIGN PRECAUTIONS]
1
2
Incorrect operation of the touch switch(s) may lead to a serious accident if the
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
GOT backlight is gone out. When the GOT backlight goes out, although the POWER LE D blinks (green/ orange) and the display section dims, the input of the touch switc h(s) remains active. This may confuse an operator in thinking that the GOT is in "screensaver" mode, who then tries to release the GOT from this mode by touching the display section, which may cause a tou ch switch to operate. Note that the following occurs on the GOT when the b acklight goes out.
• GT1655-V: The POWER LED blinks (green/orange) and the monitor screen appears blank.
• Models other than GT1655-V: The POWER LED blinks ( green/orange) and the monitor screen appears dimmed.
The display section of the GT16 is an analog-resistive t ype touch panel.
If you touch the display section simultaneously in 2 points or mor e, the switch that is located around the center of the touched poin t, if any, may operate. Do not touch the display section in 2 points or more simultaneously. Doing so may cause an accident due to incorrect o utput or malfunction.
When programs or parameters of the controller (such as a PLC) that is
monitored by the GOT are changed, be sure to reset the GOT or shut off the power of the GOT at the same time. Not doing so can cause an accident due to false outp ut or malfunction.
[DESIGN PRECAUTIONS]
Do not bundle the control and communication cables with main-circui t, power
or other wiring. Run the above cables separately from such wiring and kee p them a minimum of 100mm apart. Not doing so noise can cause a malfunction.
Do not press the GOT display section with a pointed material a s a pen or
driver. Doing so can result in a damage or failure of the dis play section.
When the GOT is connected to the Ethernet network, the available IP
address is restricted according to the system configuration.
• When multiple GOTs are connected to the Ethernet network: Do not set the IP address (192.168.0.18) for the GOTs and the controllers in the network.
• When a single GOT is connected to the Ethernet n etwork: Do not set the IP address (192.168.0.18) for th e controllers except the GOT in the network. Doing so can cause the IP address duplication. The duplication can negatively affect the communication of the device with th e IP address (192.168.0.18). The operation at the IP address duplication depe nds on the devices and the system.
Turn on the controllers and the network devices to be ready for
communication before they communicate with the GOT. Failure to do so can cause a communication err or on the GOT.
[MOUNTING PRECAUTIONS]
Be sure to shut off all phases of the external power supply used by the
system before mounting or removing the GOT main un it to/from the panel. Not doing so can cause the unit to fail or malfunction.
Be sure to shut off all phases of the external power supply used by the
system before mounting or removing the communicati on unit, option function board onto/from the GOT. Not doing so can cause the unit to fail or malfunction.
When installing the option function board, wear an earth band etc. to avoid
the static electricity. Not doing so can cause a unit corruption.
Use the GOT in the environment that satisfies the general speci fications
described in this manual. Not doing so can cause an electric shock, fire, mal function or product damage or deterioration.
When mounting the GOT to the control panel, tighten the mounting screws in
the specified torque range (0.36 to 0.48 N•m) with a Phillips-head screwdriver No.2. Undertightening can cause the GOT to drop, short circuit or malfunction. Overtightening can cause a drop, short circuit or malf unction due to the damage of the screws or the GOT.
When loading the communication unit to the GOT, fit it to the connection
interface of the GOT and tighten the mounting screws in the specified torque range (0.36 to 0.48 N•m) with a Phillips-head screwdriver No.2. Under tightening can cause the GOT to drop, short circuit or malfunction. Overtightening can cause a drop, failure or malfu nction due to the damage of the screws or unit.
When mounting the option function board onto the GOT, connect it to the
corresponding connector securely and tighten the mounting screws within the specified torque range (0.25 to 0.35 N•m) with a Phillips-head screwdriver No.1. Undertightening can cause malfunction due to po or contact. Overtightening can cause malfunction due to scr ew or unit damage.
When inserting a CF card into the GOT, push it into the insertion slot until the
CF card eject button will pop out. If not properly inserted, a bad connection may caus e a malfunction.
When inserting/removing a CF card into/from the GOT, turn the CF card
access switch off in advance. Failure to do so may corrupt data within the CF card.
When removing a CF card from the GOT, make sure to support the CF card
by hand, as it may pop out. Failure to do so may cause the CF card to drop from the GOT and break.
[MOUNTING PRECAUTIONS]
When installing a USB memory to the GOT, make sure to install the USB
memory to the USB interface firmly. Failure to do so may cause a malfunction due to poor contact.
Before removing the USB memory from the GOT, operate the utility screen
for removal. After the successful completion dialog box is displayed, remove the memory by hand carefully. Failure to do so may cause the USB memory to drop , resulting in a damage or failure of the memory.
For closing the USB environmental protection cover, fix the cover by pushing
the mark on the latch firmly to comply with the protective structure.
Remove the protective film of the GOT.
When the user continues using the GOT with the protective film, the film may not be removed.
Operate and store the GOT in environments without direct sunlig ht, high
temperature, dust, humidity, and vibrations.
When using the GOT in the environment of oil or chemicals, u se the
protective cover for oil. Failure to do so may cause failure or malfuncti on due to the oil or chemical entering into the GOT.
[WIRING PRECAUTIONS]
Be sure to shut off all phases of the external power supply used by the
system before wiring. Failure to do so may result in an electric shoc k, product damage or malfunctions.
Always ground the FG terminal, LG terminal, and Functional ground terminal
of the GOT power to the protective ground conductors dedicated to the GOT. Not doing so may cause an electric shock or malfunc tion.
When tightening the terminal screws, use a Phillips-head screwd river No.2. Terminal screws which are not to be used must be tightened always at torque
0.5 to 0.8 N•m. Otherwise there will be a danger of short circuit agai nst the solderless terminals.
Use applicable solderless terminals and tighten them with the specified
torque. If any solderless spade terminal is used, it may be disconnected when the terminal screw comes loose, resulting in fail ure.
Correctly wire the GOT power supply section after confirming the rated
voltage and terminal arrangement of the product. Not doing so can cause a fire or failure.
Tighten the terminal screws of the GOT power supply section i n the specified
torque range (0.5 to 0.8 N•m). Undertightening can caus e a short circuit or malfunction. Overtightening can cause a short circuit or mal function due to the damage of the screws or the GOT.
Exercise care to avoid foreign matter such as chips and wire offcuts entering
the GOT. Not doing so can cause a fire, failure or malfunction.
The module has an ingress prevention label on its top to preven t foreign
matter, such as wire offcuts, from entering the module during wiring. Do not peel this label during wiring. Before starting system operation, be sure to peel this label because of heat dissipation.
Plug the communication cable into the connector of the connected unit and
tighten the mounting and terminal screws in the specified torque range. Undertightening can cause a short circuit or ma lfunction. Overtightening can cause a short circuit or mal function due to the damage of the screws or unit.
Plug the QnA/ACPU/Motion controller(A series) bus connec tion cable by
inserting it into the connector of the connected u nit until it "clicks". After plugging, check that it has been inserted snug ly. Not doing so can cause a malfunction due to a contact faul t.
[TEST OPERATION PRECAUTIONS]
Before performing the test operations of the user creation monito r screen
(such as turning ON or OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter, and changing the buffer memory current value), read through th e manual carefully and make yourself familiar with the oper ation method. During test operation, never change the data of the devices which are used to perform significant operation for the system. False output or malfunction can cause an accident.
[STARTUP/MAINTENANCE PRECAUTIONS]
When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfuncti on.
Correctly connect the battery connector.
Do not perform the following actions to the battery.
• Charging, disassembling, heating, short-circuiting, or s oldering the battery, or throwing it into the fire Doing so will cause the battery to produce heat, explode, or ignite, resulting in injury and fire.
Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases. Not switching the power off in all phases can cause a uni t failure or malfunction. Undertightening can cause a short circuit or ma lfunction. Overtightening can cause a short circuit or mal function due to the damage of the screws or unit.
[STARTUP/MAINTENANCE PRECAUTIONS]
Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunct ion due to a cable connection fault.
When unplugging the cable connected to the unit, do not hold and pul l the
cable portion. Doing so can cause the unit or cable to be damaged o r can cause a malfunction due to a cable connection fault.
Do not drop the module or subject it to strong shock. A module damage ma y
result.
Do not drop or give an impact to the battery mounted to the unit.
Doing so may damage the battery, causing the battery fluid to leak inside the battery. If the battery is dropped or given an impact, dispose of it without using.
Before touching the unit, always touch grounded metals, etc. to dis charge
static electricity from human body, etc. Not doing so can cause the unit to fail or malfunction.
Replace battery with GT15-BAT or GT11-50BAT by Mitsubishi electric
Co.only. Use of another battery may present a risk of fire or exp losion.
Dispose of used battery promptly.
Keep away from children.Do not disassemble and do not dispose of in fire.
[TOUCH PANEL PRECAUTIONS]
For the analog-resistive film type touch panels, normally the adjustment is not
required. However, the difference between a touched position and the object position may occur as the period of use elapses. When any difference b etween a touched position and the object positio n occurs,execute the touch panel calibration.
When any difference between a touched position and the object pos ition
occurs, other object may be activated. This may c ause an unexpected operation due to incorrect output or malfunction.
[BACKLIGHT CHANGING PRECAUTIONS]
Before changing the backlight, always switch off the GOT power externally in
all phases (when the GOT is connected to the bus, the PLC CPU power must also be switched off externally in all phases) an d remove the GOT from the control panel. Not switching the power off in all phases may cau se an electric shock. Not removing the unit from the control panel can cause in jury due to a drop.
When replacing the backlight, use the gloves.
Otherwise, it may cause you to be injur ed.
Start changing the backlight more than 5 minutes after switching the GOT
power off. Not doing so can cause a burn due to the heat of the back light.
[DISPOSAL PRECAUTIONS]
When disposing of this product, treat it as industrial waste .
When disposing of batteries, separate them from other wastes according to the local regulations. (Refer to the User's Manual for the GOT you are usin g for details of the battery directive in the EU member states.)
[TRANSPORTATION PRECAUTIONS]
When transporting lithium batteries, make sure to treat them based on the
transport regulations. (Refer to the User's Manual for the GOT you are usin g for details of the regurated models.)
Make sure to transport the GOT main unit and/or relevant unit(s ) in the
manner they will not be exposed to the impact exceedin g the impact resistance described in the general specifications of t he User's Manual, as they are precision devices. Failure to do so may cause the unit to fail. Check if the unit operates correctly after transportation.
When fumigants that contain halogen materials such as fluorine, chlori ne,
bromine, and iodine are used for disinfecting and p rotecting wooden packaging from insects, they cause malfunction when ent ering our products. Please take necessary precautions to ensure that rem aining materials from fumigant do not enter our products, or treat packaging with methods oth er than fumigation (heat method). Additionally, disinfect and protect wood from insects before packing products.
The following shows manuals relevant to this product.
Manual
Detailed Manual
Manual name
GT16 User's Manual (Hardware) (Sold separately)
GT16 User's Manual (Basic Utility) (Sold separately)
For detailed manuals, refer to the PDF manuals stored in the DVD-ROM for the drawing software used.
Manual number
(Model code)
SH-080928ENG
(1D7MD3)
SH-080929ENG
(1D7MD4)
Relevant Manuals
For relevant manuals, refer to the Help or the PDF m anuals stored in the DVD­ROM for the drawing software used.
The latest manuals are also available from MITS UBISHI ELECTRIC FA Global Website (http://www.MitsubishiElectric.co.jp/fa/).
Before using the GOT
Connect the connector of the GOT to the connector of t he battery. For details on GT16 specifications, installing proce dure, EMC Directive, wiring, maintenance and inspection, or checking method f or the version and the compatible standard, refer to GT16 User's Manual (Hardware).
Packing List
The GOT product package includes the following:
© 2014MITSUBISHI ELECTRIC CORPORATION
Model name Product Quantity
GT1695M-X
GT1685M-S GT1675M-S GT1675M-V GT1675-VN GT1672-VN GT1665M-S GT1665M-V
GT1655-V
GOT 1
Battery (GT15-BAT) 1
Installation fitting 8
GT16 General Discription 1
GT16本体概要説明書
GOT 1
Battery (GT15-BAT) 1
Installation fitting 4
GT16 General Discription 1
GT16本体概要説明書
GOT 1
Battery (GT11-50BAT) 1
Installation fitting 4
GT16 General Discription 1
GT16本体概要説明書
1. FEATURES
(1) Improved monitoring performance and connectivity to FA devices
• GT1695M-X, GT1685 M-S, GT1675M-S, GT1675M-V, GT1665M-S, GT1665M-V, GT1655-V: The TFT color liquid crystal display (high intensity, wide angle view, and high definition type) provides clear full-color display and displays small characters clearly. (Displays digital images of BMP and other for mats in 65536 colors.) GT1675-VN, GT1672-VN, GT1662-VN: The TFT color liquid crystal display provides 4096 or 16 colors to offer a wide range of models that meet user requirements.
• Provides multi-l anguage display function based on Unicode2.1 True Type font and high-speed drawing of beautiful text.
• High speed monitori ng through high speed communication at maximum of
115.2kbps.
• High speed displ ay and high speed touch switch response.
• The operation per formance is improved by the analog touch panel.
• GT1695M-X, GT1685 M-S, GT1675M-S, GT1675M-V, GT1665M-S, GT1665M-V: Applicable to a video/RGB unit and a multimedia u nit
(2) More efficient GOT operations including screen design, s tartup, adjustment,
management and maintenance works
• GT1695M-X, GT1685 M-S, GT1675M-S, GT1675M-V, GT1665M-S, GT1665M-V, GT1655-V: 15MB user memory is included as standard. GT1675-VN, GT1672-VN, GT1662-VN: 11MB user memory is included as standard.
• Interfaces are included as standard. (Ethernet, RS-232, RS-422/485, CF card, and USB)
• Font installation is available to increase the system fonts.
• Combined use of 4 ty pes of alarms (system alarm, user alarm, alarm history, alarm popup display) realizes more efficient alarm notification.
• Maintenance timing r eport function is available that measures the ba cklight energization time and notifies of maintenance time .
• The USB interface is positioned on the GOT front. This enables the system startup to be performed more efficiently using FA device startup tool, and eliminates the necessity of indirect wor ks (opening and closing the control panel, cable replacement, cable rewiring) in order to imp rove the working efficiency.
• The blown backl ight bulb can be confirmed even during screen saving, with the blinked POWER LED at backlight shutoff detection.
(3) Enhanced support of FA device setup tools
• Transferring and monitoring sequence programs with the personal computer connected to the GOT can be executed when connectin g to a PLC CPU with the direct CPU connection or bus connection. (FA transparent function)
2. Part Names and Settings
Part Names and Settings of the GT16
Example)
21)
GT1695
2),3)
1)
4)
5)
19)
19)
6) 7) 8)
No. Name Description
1) POWER LED
2) Display screen Displays the Utility and the user creation sc reen.
3) Touch key
1
1
1
4) USB interface (Device)
5) USB interface (Host)
6) RS-232 interface
7) Ethernet interface
8) RS-422/485 interface
9) Power terminal
10) Extension interfac e1 For installing an exten sion unit (I/F-1)
11) Extension interface2
12) CF card interface For installing a CF card
13) CF card access LED Lit : CF card accessed , Not lit : CF card not accessed
14) CF card access switch
15) Video/RGB interface
Terminating resistor
16) setting switch
Optional function
17) board interface
18) Reset switch
Hole for unit
19) installation fitting
20) Battely cover
21) Human sensor
22) Installation switch Used for OS installations at the GOT startup
*1: No video/RGB interface on the GT1675-VN, G T1672-VN, GT1662-VN, and
GT1655-V. *2: Battery holder for the GT1665 and GT16 62. *3: No extension interface 2 on the GT16 55. *4: Located on the extension interface 2 o n the GT1655. *5:Integral with the CF card interface cover for t he GT1655. *6:No human sensor on the GT1675, GT1672, GT1665, GT 1662, and GT1655. *7:No LG terminal on the GT1655. *8:On the rear face of the GT1655, the functional grou nd terminal is located on the
left side of the FG terminal.
Lit in green : Power is correctly supplied , Lit in orange : Screen saving Blinks in orange/green : Blown back light bulb , Not lit : Power is not supplied
For operating touch switches in the Utility and the user creation screen
For connecting a persona l computer (Connector type: Mini­B)
For USB mouse/keyboard ,dat a transfer and storage (Connector type: TYPE-A)
For communicating with a co ntroller or connecting a personal computer(Connec tor type: D sub 9-pin)
For communicating with a controller or using the gateway function (Connector ty pe: RJ-45 (modular jack))
For communicating with a controller (Connector type: 14-pin (female))
*8
Power input terminal, LG terminal*7, FG terminal
*3
For installing an exten sion unit (I/F-2)
Used for accepting or stopping the access to the CF card before removing the CF card from the GOT ON :CF card being accessed (CF card removal
OFF :CF card not accessed (CF card removal possible)
For mounting the video input unit, RGB input unit, video/
*1
RGB input unit, RGB output unit, or multimedia unit
For switching on and off of the terminating resistor for the RS-422/485 communication port
For installing the opti onal function board
*4
Hardware reset switch (Inoperative in the bus connection or with the bus connection unit installed)
Hole for inserting the unit installation fitting
*2*5
Houses the battery
*6
Sensor that detects human movement
9)
prohibited)
GOT Rear face
19)
17) 16)
10) 11)
22)
12)
13)
14)
20)
15)
18)
3. Specifications
3.1 General Specifications
Item Specifications
Display section
Operating
Zone
ambient
d'affichage
temperature
*1
Other than the display
Température ambiante de
section
fonctionnem
Autre que la
*1
ent
zone d'affichage
Storage ambient temperature
Operating ambient humidity
Storage ambient humidity 10 to 90% RH, non-condensing
Compliant with JIS B
intermittent
Vibration resistance
Shock resistance
Operating atmosphere
Operating altitude Installation location Inside control panel Overvoltage category Pollution degree Cooling method Self-cooling Grounding Grounding with a resistan ce of 100 or less
*1: When mounting a multimedia unit (GT 16M-MMR), MELSECNET/H
communication unit (GT15-J71LP23-25, GT15-J7 1BR13), or CC-Link communication unit (GT15-J61BT13), the operating ambient temp erature must be reduced 5 °C against the maximum values describe d in general specifications.
Lors du montage d'un module multimédia (GT16M-MMR), du module de
communication MELSECNET/H (GT15-J71LP23-25, GT15-J71BR13) ou du module de communication CC-Link (GT15-J61BT13), la température ambiante de fonctionnement doit être réduite de 5°C par rapport aux valeurs maximales décrites dans les spécifications générales.
*2: Do not use or store the GOT under pr essure higher than the atmospheric
pressure of altitude 0m (0ft.). Failure to observe this instruction may cause a malfunction. When an air purge is made inside the control panel by adding pressure, there may be a clearance between the surface sheet and the screen making it difficult to use the touch panel, or the sheet may come off.
*3: This indicates the section of the power supply to which the equipment is
assumed to be connected between the public electric al power distribution network and the machinery within the premises. Category II applies to equipment for which electrical powe r is supplied from fixed facilities. The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.
*4: This index indicates the degree to which conductive material is generated in the
environment where the equipment is used. In pollution degree 2, only non-conductive pollu tion occurs but temporary conductivity may be produced due to condensa tion.
Point
Refer to GT16 User's Manual for details of the performance specifications of each GOT.
3502 and
vibration
IEC 61131-
2
continuous
vibration
Compliant with JIS B 3502 and IEC 61131-2 147 m/s2(15G),
No greasy fumes, corrosive gas, flammable gas, excessive
conductive dust, and direct sunlight (Same as storage
*2
*3
*4
3.2 Power Supply Specifications
The following indicates the power supply s pecifications for GT16.
Note
Operation at momentary failure
• If an instantaneous power failure occurs in the power supply and continues for more than the permissible period, the GOT will be reset.
• Make sure to power on the unit more than 5 seconds after power-off.
3.2.1 For GOTs powered from the 100 to 240VAC power supply
Item
Input power supply volta ge 100 to 240VAC (+10%, -15%) Input frequency 50/60Hz 5%
Input max. apparent power
Power consumption 64W or less 46W or less 39W or less
At backlight off 38W or less 32W or less 30W or less
Inrush current 28A or less (4ms) (maximum load)
GT1695M-XTBA GT1685M-STBA
(maximum load)
0 to 50
0 à 50
0 to 55
0 à 55
-20 to 60
10 to 90% RH, non-condensing
Frequency Accelera tion
5 to 8.4Hz - 3.5mm
Under
8.4
to150Hz
Under
3 times each in X, Y and Z direct ions
150VA
9.8m/s2-
5 to 8.4Hz - 1.75mm
to 150Hz
4.9m/s2-
8.4
atmosphere)
2000 m (6562 ft) max.
II or less 2 or less
Specifications
110VA
(maximum load)
Half-
Sweep
amplitude
count
10 times
each in X,
Y and Z
directions
GT1675M-STBA GT1675M-VTBA
GT1675-VNBA
GT1672-VNBA GT1665M-STBA GT1665M-VTBA
GT1662-VNBA
100VA
(maximum load)
-
Item
Allowable momentary power failure time
Noise immunity
Dielectric withstand voltage 1500VAC for 1 minute across power terminals and earth
Insulation resistance
Applicable wire size 0.75 to 2[mm
Applicable solderless terminal
Applicable tightening torque (Terminal block terminal screw)
GT1695M-XTBA GT1685M-STBA
1,500Vp-p noise voltag e, 1 s noise width (when measuring with a noise si mulator under 25 to 60Hz noise frequency)
10M or more across power termin als and earth by a 500V DC insulation resistance te ster
Solderless terminal for M3 screw RAV1.25-3, V2-S3.3,
3.2.2 For GOTs powered from the 24VDC power supply
Item
Input power supply voltage
Power consumption
At backlight off 30W or less 26W or less 27W or less 14W or less
Inrush current
Allowable momentary power failure time
Noise immunity
Dielectric withstand voltage Insulation resistance
Applicable wire size 0.75 to 2[mm
Applicable solderless terminal
Applicable tightening torque (Terminal block terminal screw)
GT1695M-
XTBD
60W or less 40W or less 38W or less 16W or less
12A or less
(75ms)
(maximum
load)
500Vp-p noise voltage, 1 s nois e width (when measuring with a noise simulator under 25 to 60Hz noise frequency)
500VDC for 1 minute across power terminals and earth
10M or more across power terminals and earth by a 500V DC insulation resistance test er
Solderess terminal for M3 screw RAV1.25-3, V2-S3.3, V2-N3A, FV2-
3.3 External Dimensions
GT1675,GT1672
10(0.39)
199 (7.83)
6(0.24)
10(0.39)
GT1655
10(0.39)10(0.39)
120(4.72)
56 (2.20)
6
(0.24)
214 (8.43)
135(5.31)
60(2.36)
303 (11.93)
252 (9.92)
222 (8.74)
288 (11.34)
167(6.57) 116(4.57)
116(4.57)
152(5.98)
49
Unit: mm (inch)
Unit: mm (inch)
Specifications
20 ms or less (100VAC or more)
V2-N3A, FV2-N3A
0.5 to 0.8[N•m]
Specifications
GT1675M-STBD GT1675M-VTBD
GT1685M-
12A or less (55ms) (maximum
GT1685
10(0.39)
227(8.94)
10(0.39)
GT1665,GT1662
(1.93)
GT1675-VNBD GT1672-VNBD
STBD
GT1665M-STBD GT1665M-VTBD
GT1662-VNBD
DC24V (+25%, -20%)
load)
10 ms or less
N3A
0.5 to 0.8[N•m]
242(9.53)
6(0.24)
56(2.20)
10(0.39)175 (6.89)
190 (7.48)
6(0.24)
10(0.39)
56 (2.20)
316(12.44) 240(10.35)
240(9.84)
301(11.85)
175.5 (6.91)
175.5 (6.91)
2
]
Unit: mm (inch)
241 (9.49)
226 (8.90)
GT1675M-STBA GT1675M-VTBA
GT1675-VNBA
GT1672-VNBA GT1665M-STBA GT1665M-VTBA
GT1662-VNBA
2
]
GT1655-VTBD
67A or less (1ms) (maximum load)
52(2.05)
Unit: mm (inch)
52
(2.05)
4. EMC AND LOW VOLTAGE DIRECTIVE
For the products sold in European countries, the conformance to the EMC Directive, which is one of the European Directives, has been a legal obligation since 1996. Also, conformance to the Low Voltage. Directive, another European Directives, has been a legal obligation since
1997. Manufacturers who recognize their products must conform to the EMC and Low Voltage Directive are required to declare that their products conform to these Directives and put a "CE mark" on their products.
• Authorized representative in Europe Authorized representative in Europe is shown below. Name :Mitsubishi Elec tric Europe BV Address :Gothaer strase 8, 40880 Ratingen, Germany
4.1 Requirements to Meet EMC Directive
EMC Directives are those which require "any strong electromagnetic force is not output to the external.:Emission (electromagnetic interference)" and "It is not influenced by the electromagnetic wave from the external.: Immunity (electromagnetic sensitivity)". Items4.1.1 through4.1.3 summarize the precautions to use GOT and configure the mechanical unit in order to match the EMC directives. Though the data described herein are produced with our best on the
basis of the requirement items and standards of the restrictions gathered by Mitsubishi, they do not completely guaranteed that all mechanical unit manufactured according to the data do not always match the above directives. The manufacturer itself which manufactures the mechanical unit must finally judge the method and others to match the EMC directives.
4.1.1 EMC directive
The standards of the EMC Directive are shown below.
Applied
standard
EN61131-2 : 2007
*1: The GOT is an open type device (device ins talled to another device) and must
Test standard Test details Standard value
Electromagnetic
*1
*1
emissions from the
*1
product are measured.
Electromagnetic emissions from the
*1
product to the power line is measured.
Immunity test in which static electricity is applied to the cabinet of the equipment.
Immunity test in which field is irradiated to the product.
Immunity test in which burst noise is applied to the power line and signal lines.
Immunity test in which lightening
*1
surge is applied to the product.
Immunity test in which a noise inducted on the power and signal lines is applied. Test for checking normal operations under the circumstance exposed to the ferromagnetic field noise of the power supply frequency (50/60Hz).
Test for checking normal operations at instantaneous power failure.
CISPR16-2-3 Radiated noise
CISPR16-2-1 Conducted noise
IEC61000-4-2 Electrostatic immunity
IEC61000-4-3 Radiated electromagnetic field AM modulation
IEC61000-4-4 Fast transient burst
*1
noise
IEC61000-4-5 Surge immunity
IEC61000-4-6 Conducted RF immunity
IEC61000-4-8 Power supply frequency magnetic field immunity
EN61000-4-11 EN61000-4-29 Instantaneous power failure and voltage dips immunity
be installed in a conductive control panel. The above test items are conducted in the condition where the GOT is installed on the conductive control panel and combined with the Mitsubishi PLC.
30M-230MHz QP: 30dB V/m (30m in measurement range) 230M-1000MHz QP: 37dB V/m(30m in measurement range)
150k-500kHz QP:79dB, Mean: 66dB 500k-30MHz QP:73dB, Mean: 60dB
4kV Contact discharge 8kV Aerial discharge
80-1000MHz:10V/m
1.4-2GHz:3V/m
2.0-2.7GHz:1V/m 80%AM modulation@1kHz Power line:2kV Digital I/O(24V or high er): 1kV (Digital I/O(24V or less))> 250V (Analog I/O, signal lines)> 250V AC power type
Power line (between line and ground): 2kV Power line (between lines) : 1kV Data communication port : 1kV
DC power type
Power line (between line and ground) : 0.5kV
Power line (between lines)
: 0.5kV
Data communication port
: 1kV
Power line: 10V Data communication port: 1 0V
30 A/m
AC power type
0.5 cycle 0% (interval 1 to 10s) 250/300 cycle 0% 10/12 cycle 40% 25/30 cycle 70%
*2, *3
*2, *3
*2
*2
*2: QP (Quasi-Peak): Quasi-peak value, Mean: Average value *3: The above test items are conducted in the foll owing conditions.
30M-230MHz QP : 40dB V/m (10m in measurement range) 230M-1000MHz QP : 47dB V/m (10m in measurement range)
4.1.2 Control panel
The GOT is an open type device (device installed to another device) and must be installed in a conductive control panel. It not only assure the safety but also has a large effect to shut down the noise generated from GOT, on the control panel. (1) Control Panel
(a) The control panel must be conductive. (b) When fixing a top or bottom plate of the control panel wit h bolts,
do not coat the plate and bolt surfaces so that they will come into contact. And connect the door and box using a thick grounding cable in order to ensure the low impedance under high frequency.
(c) When using an inner plate to ensure electric conductivity with the
control panel, do not coat the fixing bolt area of the inner plate and control panel to ensure conductivity in the largest area as possible.
(d) Ground the control panel using a thick grounding cable in order to
ensure the low impedance under high frequency.
(e)The diameter of cable holes in the control panel must be 10cm
(3.94in.). In order to reduce the chance of radio waves leaking out, ensure that the space between the control panel and its door is small as possible. Paste the EMI gasket directly on the painted surface to seal the space so that the leak of electric wave can be suppressed.
Manufacturer Series model name
KITAGAWA INDUSTRIES CO., LTD. UC series (Recommended Product)
Our test has been carried out on a panel having the damping characteristics of 37dB max. and 30dB mean (measured by 3m method with 30 to 300MHz).
(2) Connection of power and ground wires
Ground and power supply wires for the GOT must be connected as described below. (a) Provide a grounding point near the GOT. Short-circuit the LG and
FG terminals of the GOT (LG: line ground, FG: frame ground) and ground them with the thickest and shortest wire possible (The wire length must be 30cm (11.81in.) or shorter.) The LG and FG terminals function is to pass the noise generated in the PC system to the ground, so an impedance that is as low as possible must be ensured. As the wires are used to relieve the noise, the wire itself carries a large noise content and thus short wiring means that the wire is prevented from acting as an antenna. Note) A long conductor will become a more efficient antenna at high frequency.
(b) The earth wire led from the earthing point must be twisted with
the power supply wires. By twisting with the earthing wire, noise flowing from the power supply wires can be relieved to the earthing. However, if a filter is installed on the power supply wires, the wires and the earthing wire may not need to be twisted.
4.1.3 Noise filter (power supply line filter)
The noise filter (power supply line filter) is a device effective to reduce conducted noise. Except some models, installation of a noise filter onto the power supply lines is not necessary. However conducted noise can be reduced if it is installed. (The noise filter is generally effective for reducing conducted noise in the band of 10MHz or less.) Usage of the following filters is recommended.
Model name FN343-3/01 FN660-6/06 ZHC2203-11
Manufacturer SCHAFFNER SCHAFFNER TDK
Rated current 3A 6A 3A
Rated voltage 250V
The precautions required when installing a noise filter are described below.
(1) Do not install the input and output cables of the noise filter together
to prevent the output side noise will be inducted into the input side cable where noise has been eliminated by the noise filer.
Input side
(power supply side)
Filter
• I nstalling the input and output cables together will cause noise induction.
Induction
Output side
(device side)
Input side
(power supply side)
Filter
Output side
(device side)
• Separate the input cable from the output cable.
(2) Connect the noise filter's ground terminal to the control panel with
the shortest cable as possible (approx. 10cm (3.94 in.) or less).
4.2 Requirements for Compliance with the Low Voltage Directive
The Low Voltage Directive requires each device which operates with power supply ranging from 50VAC to 1000V and 75VDC to 1500V to satisfy necessary safety items. In the Sections from 4.2.1 to 4.2.5, cautions on installation and wiring of the GOT to conform to the Low Voltage Directive requires are described. We have put the maximum effort to develop this material based on the requirements and standards of the Directive that we have collected. However, compatibility of the devices which are fabricated according to the contents of this manual to the above Directive is not guaranteed. Each manufacturer who fabricates such device should make the final judgement about the application method of the Low Voltage Directive and the product compatibility.
4.2.1 Standard subject to GOT
Standard applied to GOT : EN61131-2 Programmabl e controllers - Equipment
requirements and tests
EN60950-1 Safety of In formation Technology Equipment
4.2.2 Power supply
The insulation specification of the GOT was designed assuming installation category II. Be sure to use the installation category II power supply to the GOT. The installation category indicates the durability level against surge voltage generated by lightning strike. Category I has the lowest durability; category IV has the highest durability.
Category ICategory IICategory IIICategory IV
Category II indicates a power supply whose voltage has been reduced by two or more levels of isolating transformers from the public power distribution.
Installation category
4.2.3 Control panel
Because the GOT is open type equipment (device designed to be stored within another device), be sure to use it only when installed in a control panel.
(1) Shock Protection
In order to prevent those who are unfamiliar with power facility, e.g., an operator, from getting a shock, make sure to take the following measures on the control panel. (a) Store the GOT within the control panel locked, and allow only
those who are familiar with power facility to unlock the panel.
(b) Build the structure in order that the power supply will be shut off
when the control panel is opened.
(2) Dustproof and waterproof features
The control panel also provides protection from dust, water and other substances. Insufficient ingression protection may lower the insulation withstand voltage, resulting in insulation destruction. The insulation in the GOT is designed to cope with the pollution level 2, so use in an environment with pollustion level 2 or better.
Pollution level 1: An environm ent where the air is dry and conductive
Pollution level 2: An environm ent where conductive dust does not
Pollution level 3: An environment where conductive dust exits and
Pollution level 4: Continuous con ductivity may occur due to rain, snow,
dust does not exist.
usually exist, but occasional temporary condu ctivity occurs due to the accumulated dust. Generally, this is the level for inside the control panel equivalent a control room or on the floor of a typical factory.
conductivity may be generated due to t he accumulated dust. An environment for a typical factory floor.
etc. An outdoor environment.
4.2.4 Grounding
The following are applicable ground terminals. Use them in the grounded state. Be sure to ground the GOT for ensuring the safety and complying with the EMC Directive.
Functional grounding : Improves the noise resistance.
4.2.5 External wiring
(1) External devices
When a device with a hazardous voltage circuit is externally connected to the GOT, select a model which complies with the Low Voltage Directive's requirements for isolation between the primary and secondary circuits.
(2) Insulation requirements
Dielectric withstand voltages are shown in the following table. Reinforced Insulation Withstand Voltage (Installation Category II, source : IEC664)
Rated voltage of hazardous
voltage area
150 VAC or below 2500V
300 VAC or below 4000V
Surge withstand voltage (1.2/50 s)
5. INSTALLATION
5.1 Control Panel Inside Dimensions for Mounting GOT
Install the GOT on the control panel out of the way for the equipment inside the control panel. Do not install the GOT and the unit in prohibited areas for the installation.
Point
Applicable cable Some cables may need to be longer than the specified dimensions when connecting to the GOT. Therefore, consider the connector dimensions and bending radius of the cable as well for installation.
5.2 Panel Cutting Dimensions
Make an installation hole on the control panel with the dimensions shown below. Make space of 10mm above and below the hole respectively for the installation fittings.
A
5.3 Mounting Position
When mounting the GOT, the following clearances must be maintained from other structures and devices. Depending on the units and cables connected to the GOT, clearances more than the described dimensions can be required. Therefore, consider the connector dimensions and bending radius of the cable as well for installation. For the lead-in allowance for cables at the bottom of the GOT, refer to the GT16 User’s Manual (Hardware) .
According to the dimensions in the following table, leave clearances between the GOT and the other devices. The values enclosed in square brackets apply to the case where no other equipment generating radiated noise (such as a contactor) or heat is installed near the GOT. However, keep the ambient temperature of the GOT to 55°C or lower.
*Panel thickness : 2 to 4 mm (0.08 to 0.16 inch)
GT1695M-X
B
GT1685M-S
GT1675M-S GT1675M-V GT1675-VN GT1672-VN GT1665M-S GT1665M-V GT1662-VN
GT1655-V
GOT
A[mm] (inch)
383.5 (15.10)
+2 (0.08) 0 (0)
302 (11.89)
+2 (0.08) 0 (0)
289 (11.38)
+2 (0.08) 0 (0)
227 (8.94)
+2 (0.08) 0 (0)
153(6.02)
+2 (0.08) 0 (0)
B
C
DE
A
Panel thickness: 2 to 4mm
(0.08 to 0.16 inch)
B[mm] (inch)
282.5 (11.12)
+2 (0.08) 0 (0)
228 (8.98)
+2 (0.08) 0 (0)
200 (7.87)
+2 (0.08) 0 (0)
176 (6.93)
+2 (0.08) 0 (0)
121(4.76)
+2 (0.08) 0 (0)
GT1665M-S GT1665M-V GT1662-VN
50(1.97) or
more [36(1.42) or more]
73(2.87) or
more
50(1.97) or
more
*1
*2
*3
*2*3
*3
*2
50(1.97) or
more [36(1.42) or more]
Unit : mm(inch)
GT1675M-S
Item
GOT only
Bus connection unit is fitted Serial communication unit fitted RS-422 Conversion unit is fitted CC-Link communication unit (GT15-J61BT13) fitted
MELSECNET/H communication unit (coaxial) fitted
MELSECNET/H communication unit (optical) fitted
CC-Link IE Controller Network communication unit fitted
CC-Link IE Field
A
Network communication unit fitted Video input unit
*4
fitted RGB input unit
*4
fitted Video/RGB input unit
*4
fitted RGB output unit
*4
fitted Multimedia unit
*4
fitted
Printer unit fitted
CF card unit
CF card extension unit
Sound output unit
B
(When the CF card is not used)
C
(When the CF card is used)
D
E
*1: This value differs depending on the cable used.
Please contact your local Mitsubishi Electr ic System & Service Co., Ltd. The value indicated in the table is a reference value.
*2: This value is for use of the coaxial cable 3C-2V (JIS C 3501).
For specifications of the cable, refer to the GOT1000 Series Connection Manual for GT Works3 and a controller used.
*3: This value differs depending on the cable used .
If the bending radius of the cable used is greater than the value specified above, apply the value of the cable used.
*4: The unit cannot be used for the GT1675-V, GT1672-V, GT1662-V, and
GT1655-V.
*5: Dimension when no battery is used.
If a battery is used, the dimension when a CF card is used is required.
Point
Refer to GT16 User’s Manu al (Hardware) for details of the Control Panel Ins ide Temperature and Mounting Angle, Installation Procedure of each GOT.
GT1695M-X GT1685M-S
50(1.97) or more
[20(0.79) or more]
50(1.97) or
more
50(1.97) or more [20(0.7 9) or more]
50(1.97) or
more [20(0.79) or more]
50(1.97) or more [20(0.79) or more]
50(1.97) or more [20(0.7 9) or more]
50(1.97) or more [20(0.79) or more]
50(1.97) or more [20(0.79) or more]
50(1.97) or more [20(0.79) or more]
50(1.97) or more [20(0.79) or more]
50(1.97) or more [20(0.79) or more]
50(1.97) or more
[20(0.79) or more]
50(1.97) or more [20(0.7 9) or more]
GT1675M-V GT1675-VN GT1672-VN
50(1.97) or
more [26(1.02) or more]
51(2.01) or
63(2.48) or
more
more
50(1.97) or
50(1.97) or
more
more
[24(0.94)
[33(1.30)
or more]
or more]
50(1.97) or
more [26(1.02) or more]
80 (3.15) or more [20 (0.79) or more]
50(1.97) or more [20(0. 79) or more]
100(3.94) or more [20 (0.79) or more]
GT1655-V
61(2.40) or
more
50(1.97) or
more
49(1.93) or
more
-
50(1.97) or
more
[24(0.94)
or more]
64(2.52) or
more
79(3.11) or
more
57(2.24) or
more
-
-
-
-
-
50(1.97) or
more
[29(1.14)
or more]
50(1.97) or
more
[20(0.79)
or more]
50(1.97) or
moreExternal I/O unit
50(1.97) or
more
[20(0.79) or more] 100(3.94)
or more
Unité : mm (pouce)
GT1675M-S
GT1665M-S
GT1675M-V
GT1665M-V
GT1675-VN
GT1662-VN
GT1672-VN
50 (1,97)
50 (1,97)
ou plus
ou plus
[26 (1,02)
[36 (1,42)
ou plus]
ou plus]
51 (2,01)
63 (2,48)
ou plus
50 (1,97)
ou plus
[33 (1,30)
ou plus]
50 (1,97)
ou plus
[26 (1,02)
ou plus]
73 (2,87)
ou plus
50 (1,97)
ou plus
*1
*2
*3
*2*3
*3
*2
50 (1,97)
ou plus
[36 (1,42)
ou plus]
ou plus
50 (1,97)
ou plus
[24 (0,94)
ou plus]
80 (3,15) ou plus [20 (0,7 9) ou plus]
50 (1,97) ou plus [20 (0,7 9) ou plus]
100 (3,94) ou plus [20 (0, 79) ou plus]
GT1655-V
61 (2,40)
ou plus
50 (1,97)
ou plus
49 (1,93)
ou plus
-
50 (1,97)
ou plus
[24 (0,94)
ou plus]
64 (2,52)
ou plus
79 (3,11)
ou plus
57 (2,24)
ou plus
-
-
-
-
-
50 (1,97)
ou plus
[29 (1,14)
ou plus]
50 (1,97)
ou plus
[20 (0,79)
ou plus]
50 (1,97)
ou plus
50 (1,97)
ou plus [20 (0,79) ou plus]
100 (3,94)
ou plus
*5
*4
GT1695M-X GT1685M-S
50 (1,97) ou plus [20
(0,79) ou plus]
50 (1,97)
ou plus
50 (1,97) ou plus [20 (0,79) ou plus]
50 (1,97)
ou plus
[20 (0,79)
ou plus]
50 (1,97) ou plus [20 (0,79) ou plus]
50 (1,97) ou plus [20 (0,79) ou plus]
50 (1,97) ou plus [20 (0,79) ou plus]
50 (1,97) ou plus [20 (0,79) ou plus]
50 (1,97) ou plus [20 (0, 79) ou plus]
50 (1,97) ou plus [20 (0,79) ou plus]
50 (1,97) ou plus [20 (0,79) ou plus]
50 (1,97) ou plus [20
(0,79) ou plus]
50 (1,97) ou plus [20 (0,79) ou plus]
5. INSTALLATION
5.1 Dimensions intérieures du tableau de commande pour le montage du GOT
Installez le GOT sur le tableau de commande en laissant de l'espace pour le dispositif à l'intérieur du tableau de commande. N'installez pas le GOT et le module dans des zones où l'installation est interdite.
Point
Câble applicable Certains câbles peuvent être plus longs que les dimensions spécifiées lors de la connexion au GOT. Par conséquent, prenez également en compte les dimensions du connecteur et le rayon de co urbure du câble pour l'installation.
5.2 Cotes de découpe du panneau
Faites un trou d'installation sur le tableau de commande avec les dimensions indiquées ci-dessous. Laissez un espace de 10mm au-dessus et sous le trou respectivement pour les attaches de montage.
5.3 Position de montage
Lors du montage du GOT, laissez les espaces suivants pour les autres structures et dispositifs. En fonction des modules et des câbles connectés au GOT, il peut être nécessaire de laisser des espaces plus importants que les dimensions indiquées. Par conséquent, prenez également en compte les dimensions du connecteur et le rayon de courbure du câble pour l'installation. Pour connaître l'espace à laisser pour les câbles sous le GOT, référez­vous au manuel GT16 User’s Manual (Hardware).
*5
Laissez les espaces entre le GOT et les autres dispositifs en fonction des dimensions contenues dans le tableau suivant. Les valeurs entre parenthèses s'appliquent au cas où aucun dispositif générant des émissions sonores (comme un contacteur) ou de la chaleur n'est installé près du GOT. Toutefois, maintenez la température ambiante du GOT à 55°C ou moins.
A
*Épaisseur du panneau : 2 à 4mm ou moins
GT1695M-X
B
GT1685M-S
GT1675M-S GT1675M-V GT1675-VN GT1672-VN GT1665M-S GT1665M-V GT1662-VN
GT1655-V
GOT
A [mm] (pouce)
383.5 (15.10)
+2 (0.08) 0 (0)
302 (11.89)
+2 (0.08) 0 (0)
289 (11.38)
+2 (0.08) 0 (0)
227 (8.94)
+2 (0.08) 0 (0)
153(6.02)
+2 (0.08) 0 (0)
B[mm] (pouce)
282.5 (11.12)
+2 (0.08) 0 (0)
228 (8.98)
+2 (0.08) 0 (0)
200 (7.87)
+2 (0.08) 0 (0)
176 (6.93)
+2 (0.08) 0 (0)
121(4.76)
+2 (0.08) 0 (0)
B
C
DE
A
Épaisseur du panneau : 2 à 4mm
(0,08 à 0,16 pouce)
Article
GOT uniquement
Unité de connexion de bus encastrée
Module de communication série encastré
Unité de conversion RS-422 encastrée
Module de communication CC­Link (GT15-J61BT13) encastré
Module de communication MELSECNET/H (coaxial) encastré
Module de communication MELSECNET/H (optique) encastré
Module de communication réseau de contrôleur CC-Link IE encastré
Module de
A
communication réseau de champ CC-Link IE encastré
Module d'entrée vidéo
*4
encastré Module d'entrée RGB
*4
encastré Module d'entrée vidéo/
RGB encastré Module de sortie RGB
*4
encastré Module multimédia
*4
encastré
Imprimante encastrée
Module de carte CF
Module d'extension de carte CF
Module d'E/S externe Module de sortie
acoustique
B
(Quand la carte CF n'est pas utilisée)
C
(Quand la carte CF est utilisée)
D E
*1 : Cette valeur diffère selon le câble utilisé.
Contactez le bureau local Mitsubishi Electric System & Service Co., Ltd. La valeur indiquée dans le tableau est une référence.
*2 : Cette valeur est utilisée pour le câble coaxial 3C-2V (JIS C 3501).
Pour connaître les spécifications du câble , référez-vous au GOT1000 Series Connection Manual for GT Works3 and a controller used.
*3 : Cette valeur diffère selon le câble utilisé.
Si le rayon de courbure du câble utilisé est supérieur à la val eur spécifiée ci-dessus, appliquez la valeur du câble utilisé.
*4 : Le module ne peut pas être utilisé pour les modèles GT1675-V, GT1672-V,
GT1662-V et GT1655-V.
*5 : Dimension quand aucune batterie n'est utilisée.
Si une batterie est utilisée, il est néces saire d'utiliser la dimension quand une carte CF est utilisée.
Point
Référez-vous au manuel GT16 User’s Manual (Hardware) pour obtenir des détails sur la température intérieure et l'angle de m ontage du tableau de commande et sur la procédure d'installation de chaque GOT.
6. MAINTENANCE AND INSPECTION
Refer to the GT16 User's Manual (Hardware) for maintenance and inspection for the GOT.
Warra nty
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties.
For safe use
• This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.
• Before using t he product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
Country/Region Sales office/Tel
U.S.A Mitsubishi Electric Automation Inc. 500 Corporate Woods Parkway Vernon Hills, IL 60061, U.S.A. Tel : +1-847-478-2100 Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda. Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar Paraiso, Sao Paulo, SP Brazil Tel : +55-11-5908-8331 Germany Mitsubishi Electric Europe B.V. German Branch Gothaer Strasse 8 D-40880 Ratingen, GERMANY Tel : +49-2102-486-0 U.K Mitsubishi Electric Europe B.V. UK Branch Travellers Lane, Hatfield, Hertfordshire., AL10 8XB, U.K. Tel : +44-1707-276100 Italy Mitsubishi Electric Europe B.V. Italian Branch Centro Dir. Colleoni, Pal. Perseo-Ingr.2 Via Paracelso 12, I-20041 Agrate Brianza., Milano, Italy Tel : +39-039-60531 Spain Mitsubishi Electric Europe B.V. Spanish Branch Carretera de Rubi 76-80, E-08190 Sant Cugat del Valles, Barcelona, Spain Tel : +34-93-565-3131 France Mitsubishi Electric Europe B.V. French Branch 25, Boulevard des Bouvets, F-92741 Nanterre Cedex, France Tel : +33-1-5568-5568 South Africa Circuit Breaker Industries Ltd. Private Bag 2016, ZA-1600 Isando, South Africa Tel : +27-11-928-2000 Hong Kong Mitsubishi Electric Automation (Hong Kong) Ltd. 10th Floor, Manulife Tower, 169 Electric Road, North Point, Hong Kong Tel : +852-2887-8870 China Mitsubishi Electric Automation (China) Ltd. 4/F Zhi Fu Plazz, No.80 Xin Chang Road, Shanghai 200003, China Tel : +86-21-6120-0808 Taiwan Setsuyo Enterprise Co., Ltd. 6F No.105 Wu-Kung 3rd.Rd, Wu-Ku Hsiang, Taipei Hsine, Taiwan Tel : +886-2-2299-2499 Korea Mitsubishi Electric Automation Korea Co., Ltd. 1480-6, Gayang-dong, Gangseo-ku Seoul 157-200, Korea Tel : +82-2-3660-9552 Singapore Mitsubishi Electric Asia Pte, Ltd. 307 Alexandra Road #05-01/02, Mitsubishi Electric Building, Singapore 159943 Tel : +65-6470-2460 Thailand Mitsubishi Electric Automation (Thailand) Co., Ltd. Bang-Chan Industrial Estate No.111 Moo 4, Serithai Rd, T.Kannayao, A.Kannayao, Bangkok 10230 Thailand Tel : +66-2-517-1326 Indonesia P.T. Autoteknindo Sumber Makmur Muara Karang Selatan, Block A/Utara No.1 Kav. No.11 Kawasan Industri Pergudangan Jakarta - Utara 14440, P.O.Box 5045 Jakarta, 11050 Indonesia Tel : +62-21-6630833 India Messung Systems Pvt, Ltd. Electronic Sadan NO:III Unit No15, M.I.D.C Bhosari, Pune-411026, India Tel : +91-20-2712-3130 Australia Mitsubishi Electric Australia Pty. Ltd. 348 Victoria Road, Rydalmere, N.S.W 2116, Australia Tel : +61-2-9684-7777
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice. Printed in Japan, October 2014.