[8]
[1]
[8]
[9]
[3]
[4]
[2]
[7]
[5]
[6]
Side
B
Side
A
Side
B
JAPANESE ENGLISH
JY997D51701E
FX3S-30M/E-2AD
HARDWARE MANUAL
Manual Number JY997D51701
Revision E
Date December 2017
This manual describes the part names, dimensions, mounting, cabling and
specifications of the product. Before use, read this manual and the manuals of
all relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration: Phillips is a registered trademark of Phillips Screw Company.
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective December 2017
Specifications are subject to change without notice.
Safety Precaution (Read these precautions before use.)
If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
This manual classifies the safety precautions into two categories:
Depending on the circumstances, procedures indicated by may
also cause severe injury.
It is important to follow all precautions for personal safety.
and .
STARTUP AND MAINTENANCE
PRECAUTIONS
• Do not touch any terminal while the PLC's power is on.
Doing so may cause electric shock or malfunctions.
• Before cleaning or retightening terminals, cut off all phases of the power
supply externally. Failure to do so may cause electric shock.
• Before modifying or disrupting the program in operation or running the
PLC, carefully read through this manual and the associated manuals and
ensure the safety of the operation.
An operation error may damage the machinery or cause accidents.
STARTUP AND MAINTENANCE
PRECAUTIONS
• Turn off the power to the PLC before attaching or detaching the memory
cassette. If the memory cassette is attached or detached while the PLC's
power is on, the data in the me mory may be destroyed, or th e memory
cassette may be damaged.
• Do not disassemble or modify the PLC.
Doing so may cause fire, equipment failures, or malfunctions.
For repair, contact your local Mitsubishi Electric representative.
• Turn off the power to the PLC before connecting or disconnecting any
connection cable.
Failure to do so may cause equipment failures or malfunctions.
© 2013 MITSUBISHI ELECTRIC CORPORATION
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
STARTUP AND MAINTENANCE
PRECAUTIONS
• Turn off the power to the PLC before attaching or detaching the following
devices. Failure to do so may cause equipment failures or malfunctions.
- P eripheral devices, display module, expansion boards, special
adapters and memory cassette
• Do not use the chemicals for cleaning.
• If there is the possibility of touching the PLC inside a control panel in
maintenance, make sure to discharge to avoid the influence of static
electricity.
DISPOSAL PRECAUTIONS
• Please contact a certified electronic waste disposal company for the
environmentally safe recycling and disposal of your device.
TRANSPORTATION AND
STORAGE PRECAUTIONS
• The PLC is a precision instrument. During transportation, avoid impacts
larger than those specified in section 3.1 by usi ng dedicated packaging
boxes and shock-absorbing palettes.
Failure to do so may cause failures in the PLC.
After transportation, verify operation of the PLC and check for damage of
the mounting part, etc.
Associated manuals
How to obtain manuals
For the necessary product manuals or documents, consult with your local
Mitsubishi Electric representative.
Associated manuals
FX
3S-30M/E-2AD comes with this document (hardware manual).
For a detailed explanation of the FX
instructions for PLC programming, refer to the relevant documents.
Specifications not described in this manual are same as FX
refer to the following manual.
3S Series User's Manual
FX
- Hardware Edition
3S/FX3G/FX3GC/FX3U/
FX
3UC Series Programming
FX
Manual - Basic & Applied
Instruction Edition
MELSEC-Q/L/F Structured
Programming Manual
(Fundamentals)
FXCPU Structured
Programming Manual
[Device & Common]
FXCPU Structured
Programming Manual
[Basic & Applied Instruction]
FXCPU Structured
Programming Manual
[Application Functions]
FX Series User’s Manual
- Data Communication
Edition
3S/FX3G/FX3GC/FX3U/
FX
3UC Series User's Manual
FX
- Analog Control Edition
3S/FX3G/FX3GC/FX3U/
FX
3UC Series User's Manual
FX
- Positioning Control Edition
→ Refer to FX
Manual name Manual No. Description
3S Series hardware and information on
3S PLC. For details,
3S Series User's Manual - Hardware Edition.
3S Series PLC
JY997D48601
MODEL CODE:
09R535
JY997D16601
MODEL CODE:
09R517
SH-080782
MODEL CODE:
13JW06
JY997D26001
MODEL CODE:
09R925
JY997D34701
MODEL CODE:
09R926
JY997D34801
MODEL CODE:
09R927
JY997D16901
MODEL CODE:
09R715
JY997D16701
MODEL CODE:
09R619
JY997D16801
MODEL CODE:
09R620
Explains FX
specification details for I/O,
wiring, installation, and
maintenance.
Describes PLC programming
for basic/applied instructions
STL/SFC programming and
devices.
Programming methods,
specifications, functions, etc.
required to create structured
programs.
Devices, parameters, etc.
provided in structured
projects of GX Works2.
Sequence instructions
provided in structured
projects of GX Works2.
Application functions
provided in structured
projects of GX Works2.
Explains N:N link, parallel
link, computer link, no
protocol communication by
RS instructions/FX
Describes specifications for
analog control and
programming methods for
FX
3S/FX3G/FX3GC/FX3U/
3UC Series PLC.
FX
Explains the specifications
for positioning control of
FX3S/FX3G/FX3GC/FX3U/
3UC Series and
FX
programming procedures.
2N-232IF.
Certification of UL, cUL standards
Please consult with Mitsubishi Electric for information on UL, cUL standard
practices and the corresponding types of equipment.
Compliance with EC directive (CE Marking)
This product complies with EC directive, however, this document does not
guarantee that a mechanical system including this product will comply with EC
directive.
Compliance to EMC directive and LVD directive of the entire mechanical
system should be checked by the user/manufacturer. For more details please
contact the local Mitsubishi Electric sales site.
Caution for compliance with EC Directive
• Please use the FX3S programmable controllers while installed in conductive
shielded control panels under a general industrial environment.
• Programmable controllers are open-type devices that must be installed and
used within conductive control panels. Please secure the control box lid to
the control box (for conduc tion). Installation within a con trol box greatly
affects the safety of the system and aids in shielding noise from the
programmable controller.
• For the control panel, use the product having sufficient strength, fire
protectiveness and shielding property to an installation environment.
• 24 V DC of the power supply must be supplied from the circuit double/
reinforced insulated from the main power supply (MAINS).
Caution for compliance with the LVD directive (EN61010-2-201:2013)
• To an external connection port other than AC power supply terminal and AC
input/output terminal, connect the circuit separated from a dangerous
voltage by a double/reinforced insulation.
• Between the commons having the adjacent relay output terminals, if an
external power supply is higher than 120 V AC, the insulation is basic.
Therefore, when using 120 V AC or higher external power supply and 30 V
DC/AC or lower external power su pply between the adjacent commo ns, do
not handle 30 V DC/AC or lower external power supply as a touchable part,
(When handling 30 V DC/AC or lower external power supply as a touchable
part, add a basic insulation.)
• Do not wire two or more crimp terminals to one terminal. (If the wiring with
two or more wires is needed, take an appropriate actio n such as adding an
external terminal.)
• For crimp terminals to be used for the wiring applied with 30 V AC or higher,
use the products with insulating sleeves.
• Cutoff device such as a breaker or a circuit protector should be installed in
accordance with the following precautions.
- Us e EN60947-1 or EN60947-3 standards.
- Use CP30-BA 2P 1-MD 0.5A or the cutoff device having the cutoff performance
equivalent to CP30-BA 2P 1-MD 0.5A.
- P lace the cutoff device so that it can be operated easily.
- Specify that the cutoff device is for this equipment.
*1 For the time of compliance with the LVD directive (EN61010-2-201:2013),
Analog input/output
The analog input/output have been found to be compliant to the European
standards in the aforesaid manual and directive. However, for the very best
performance from what are in fact delicate measuring and controlled output
devices, Mitsubishi Electric would like to make the following points.
As analog devices are sensitive by nature, their use should be considered
carefully. For users of proprietary cables (integral with sensors or actuators),
these users should follow those manufacturers' installation requirements.
Mitsubishi Electric recommends that shielded cables be used. If NO other EMC
protection is provided, users may experience temporary loss or accuracy
between +10 %/-10 % in very heavy industrial areas.
However, Mitsubishi Electric suggests that adequate EMC precautions be
followed for the users complete control system.
3S Series User's Manual - Hardware Edition.
refer to FX
- S ensitive analog cables should not be laid in the same trunking or cable
conduit as high voltage cabling. Where possible, users should run analog
cables separately.
- Good cable shielding should be used. When terminating the shield at
Earth, ensure that no earth loops are accidentally created.
- W hen reading analog values, EMC accuracy can be improved by
averaging the readings. This can be achieved either through functions on
the analog products or through a user's program in the FX
main unit.
*1
3S Series PLC
Incorporated Items
Check if the following product and items are included in the package:
Included Items
3S-30MR/ES-2AD,
FX
3S-30MT/ES-2AD,
FX
FX
3S-30MT/ESS-2AD
Product 1 unit
Dust proof protection sheet 1 sheet
Manuals [Japanese/English] 1 manual
1. Feature
FX3S-30M/E-2AD is a product based on FX3S PLC, with built-in analog
input in place of variable analog potentiometers.
(Refer to the following figure)
Specifications other than the built-in analog input are the same as FX
For details, refer to FX
For details on the built-in analog input, refer to Chapter 6.
ariable analog potentiometer
3S Series User's Manual - Hardware Edition.
Analog input terminal block
3S PLC.
2. Outline
2.1 Part names
No. Name
[1] Top cover
[2]
[3] Terminal block covers
[4] Input display LEDs (red)
[5] Peripheral device connecting connector cover
[6]
[7] Output display LEDs (red)
[8] The year and month of production
[9] Model name (abbreviation)
[10] DIN rail mounting hooks
When the top covers are open
No. Name
[1] Optional equipment connector
[2] Power supply terminal, Input (X) terminals
[3] Analog input terminal block
[4] RUN/STOP switch
[3]
[2]
[1]
Terminal names
shows a function grounding terminal.
Operation status display LEDs
POW Green On while power is on the PLC.
RUN Green On w hile the PLC is running.
Red Flashing when a program error occurs.
ERR
Red Lights when a CPU error occurs.
[4]
[5]
[6]
[7]
[8][9][10]

No. Name
W
Unit: mm (inches)
75 (2.96″)
8 (0.32″)
90 (3.55″)
W1 (Mounting hole pitches)
Mounting hole pitches
2-4.5 mounting holes
82 (3.23″)
FX3S Series
main unit
FX
3U
-4AD-ADP
FX
3S
-CNV-ADP
A
50 mm (1.97")
A
A
A
A
[5] Peripheral device connecting connector (USB)
[6] Peripheral device connecting connector (RS-422)
[7] Service power supply terminal, Output (Y) terminals
[8] Terminal cover
[9] Optional equipment connecting screw holes
Right side
Genuine product certification label
*1
Nameplate
The authentication label for authorized products is affixed to the right side of the
product to avoid to be forged.
Products that do not have the genuine product certification label or nameplate
are not covered by the warranty.
*1 is a mark that instructs to use the cable with an appropriate
temperature rating (80°C or more) for wiring.
2.2 External dimensions and weight
W1:mm (inches)
Model name
FX
3S-30M/E-2AD 100 (3.94”) 92 (3.63”)
Installation
• 35-mm-wide DIN rail or Direct (screw) mounting (M4×2)
W:
mm (inches)
Direct mounting
hole pitches
3. Installation (generic specifications)
As for installation of the special adapters and ex pansion boards, refer to the
following manual.
INSTALLATION
PRECAUTIONS
• Use the product within the generic environment specifications described in
section 3.1 of this manual.
Never use the product in areas with excessive dust, oily smoke,
conductive dusts, corrosive gas (salt air, Cl
flammable gas, vibration or impacts, or expose it to high temperature,
condensation, or rain and wind.
If the product is used in such conditions, electric shock, fire, malfunctions,
deterioration or damage may occur.
• Do not touch the conductive parts of the product directly.
Doing so may cause device failure or malfunctions.
• Install the product securely using a DIN rail or mounting screws.
• Install the product on a flat surface.
If the mounting surface is rough, undue force will be applied to the PC
board, thereby causing nonconformities.
• When drilling screw holes or wiring, make sure that cutting and wiring
debris do not enter the ventilation slits of the PLC.
Failure to do so may cause fire, equipment failures or malfunctions.
• Be sure to remove the dust proof sheet from the PLC's ventilation port
when installation work is completed. Failure to do so may cause fire,
equipment failures or malfunctions.
• Connect the peripheral device cables securely to their designated
connectors. Loose connections may cause malfunctions.
→ Refer to FX
3S Series User's Manual - Hardware Edition.
2, H2S, SO2 or NO2),
MASS (Weight):
kg (lbs)
Approx. 0.45
(0.99 lbs)
INSTALLATION
PRECAUTIONS
• Turn off the power to the PLC before attaching or detaching the following
devices. Failure to do so may cause device failures or malfunctions.
- P eripheral devices, display module, expansion boards, special
adapters and memory cassette
Notes
• When a dust proof sheet is supplied with units, keep the sheet applied to
the ventilation slits during installation and wiring work.
• To prevent temperature rise, do not install the PLC on a floor, a ceiling or a
vertical surface.
Install it horizontally on a wall as shown in section 3.2.
• Keep a space of 50 mm (1.97”) or more between the unit main body and
another device or structure (part A). Install the unit as far away as possible
from high-voltage lines, high-voltage devices and power equipment.
Failure to do so may cause fire, equipment failures or malfunctions.
3.1 Generic specifications
Item Specification
Ambient
temperature
Ambient
humidity
Vibration
resistance
Shock
resistance
Noise
resistance
Dielectric
withstand
voltage
Insulation
resistance
Grounding
Working
atmosphere
Working
altitude
Installation
location
Over
voltage
category
Pollution
degree
0 to 55 °C (32 to 131 °F) when operating and
-25 to 75 °C (-13 to 167 °F) wh en stored
5 to 95 %RH (no condensation) when operating
Frequency
Acceleration
(Hz)
(m/s
When
installed
*1
on DIN rail
When
installed
directly
147 m/s2 Acceleration, Action time: 11 ms, 3 times by half-sine
*1
pulse in each direction X, Y, and Z
By noise simulator at noise voltage of 1,000 Vp-p, noise width of 1
μ
10 to 57 - 0.035
57 to 150 4.9 -
10 to 57 - 0.075
57 to 150 9.8 -
s, rise time of 1 ns and period of 30 to 100 Hz
Half
amplitude
2
)
(mm)
1.5 kV AC for 1 min
*2
500 V AC for 1 min
5 MΩ or higher by 500
V DC insulation
*2
resistance tester
Class D grounding (grounding resistance: 100 Ω or less)
<Common grounding with a heavy electrical system is not
*3
allowed.>
Free from corrosive or flammable gas and excessive conductive
dusts
*4
<2000 m
Inside a control panel
Between each terminals and
ground terminal
*5
*2
ΙΙ or less
2 or less
Sweep
Count
for X, Y, Z:
10 times
(80 min in
each
direction)
*1 The criterion is shown in IEC61131-2.
*2 Dielectric withstand voltage and insulation resistance are shown in the
following table.
Ter min al
Terminals of main units
Between power supply terminal (AC
power) and ground terminal
Between input terminal (24 V DC) and
ground terminal
Between output terminal (relay) and
ground terminal
Between output terminal (transistor) and
ground terminal
Main unit analog input terminal and
ground terminal
Terminals of expansion boards, special adapters
Between terminal of expansion board
3G-4EX-BD and FX3G-2EYT-
(except FX
BD) and ground terminal
3G-4EX-BD input terminal
Between FX
(24 V DC) and ground terminal
Between FX3G-2EYT-BD output
terminal (transistor) and ground terminal
Between terminal of special adapter
and ground terminal
For dielectric with stand voltage test and insulation resistance test of each
product, refer to the following manual.
*3 For common grounding, refer to section 4.3.
*4 The PLC cannot be used at a pressure higher than the atmospheric
*5 The programmable controller is assumed to be installed in an
3.2 Installation location
Install the PLC in an environment conforming to the generic specifications
(section 3.1), installation precautions and notes.
Installation location in enclosure
Space in enclosure
Special adapter can be connected on the left sides of the main unit.
If you intend to add special adapter in the future, keep necessary spaces on the
left sides.
3.2.1 Affixing the dust proof sheet
The dust proof sheet should be affixed to the ventilation port before beginning
the installation and wiring work.
Be sure to remove the dust proof sheet when the installation and wiring work is
completed.
→ Refer to FX
pressure to avoid damage.
environment equivalent to indoor.
→ For the affixing procedure, refer to the instructions on the
3S Series User's Manual - Hardware Edition.
Dielectric
strength
1.5 kV AC
for 1 min
500 V AC
for 1 min
1.5 kV AC
for 1 min
500 V AC
for 1 min
Insulation
resistance
5 MΩ or higher
by 500 V DC
insulation
resistance
tester
Not allowed Not allowed
Not allowed Not allowed
5 MΩ or higher
for 1 min
by 500 V DC
insulation
resistance
tester
500 V AC
dust proof sheet.
3.3 Procedures for installing to DIN rail
The products can be installed on a DIN46277 rail [35 mm (1.38”) wide].
This section explains the installations of the main units.
For the special adapters, refer to the following manual.
3.3.1 Installation
1) Push out all DIN rail mounting hooks (below fig. A).
→ Refer to FX
3S Series User's Manual - Hardware Edition.
B
1)
A
2) Fit the upper edge of the DIN rail
mounting groove (right fig. B) onto
the DIN rail.
1)
A
B
3) Lock the DIN rail mounting hooks
(below fig. C) while pressing the
PLC against the DIN rail.
3.4 Procedures for installing directly (with M4 screws)
The product can be installed directly on the panel (with screws).
This section explains the installation of the main units.
For the special adapters, refer to the following manual.
3.4.1 Mounting hole pitches
Refer to the External Dimensions (section 2.2) for the product's mounting hole
pitch information.
3.4.2 Installation
1) Make mounting holes in the
mounting surface referring to the
external dimensions diagram.
2) Fit the main unit (A in the right
figure) based on the holes, and
secure it with M4 screws (B in the
right figure).
→ Refer to FX
3S Series User's Manual - Hardware Edition.
B
A
B