This manual contains text, diagrams and explanations which will guide the reader in the correct
installation, safe use and operation of the F94*GOT-*WD-E and should be read and understood before
attempting to install or use the unit. Further information can be found in the associated manuals list below.
Specifications are subject to change without notice
Guidelines for the Safety of the User and Protection of the
F94*GOT-*WD-E
This manual has been written to be used by trained and competent personnel. The definition of such a
person or persons is as follows:
a) Any engineer using the product associated with this manual, should be of a competent nature,
trained and qualified to the local and national standards. These engineers should be fully aware of
all aspects of safety with regards to automated equipment.
b) Any commissioning or service engineer must be of a competent nature, trained and qualified to
the local and national standards.
c) All operators of the completed equipment should be trained to use that product in a safe and
co-ordinated manner in compliance to established safety practices.
The term ‘completed equipment’ refers to a third party constructed device which contains or uses
Note:
the product associated with this manual.
Note’s on the Symbols Used in this Manual
At various times through out this manual certain symbols will be used to highlight points of information
which are intended to ensure the users personal safety and protect the integrity of equipment.
1) Indicates that the identified danger
cause physical and property damage.
WILL
2) Indicates that the identified danger could
damage.
•Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage
that may arise as a result of the installation or use of this equipment.
•All examples and diagrams shown in this manual are intended only as an aid to understanding the
text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the
product based on these illustrative examples.
•Owing to the very great variety in possible application of this equipment, you must satisfy yourself as
to its suitability for your specific application.
POSSIBLY
cause physical and property
Associated Manuals
Manual NameManual NumberDescription
F940GOT Series
|
(F94*GOT-*WD-E)
Installation Manual
GOT-F900
~
OPERATION MANUAL
(describes GT Designer2)
GOT-F900 Series
~
Operation Manual
GOT-F900 Series
~
Hardware Manual
(connection diagram)
GT Designer2 Version1
|
Operating Manual
GT Designer2 Version1
|
Reference Manual
GT Designer
|
Operating Manual
FX-PCS-DU/WIN-E
|
SOFTWARE MANUAL
F9GT-40FMB
User’s Manual
JY997D94201
JY992D09101
(separate volume)
JY992D94701
(separate volume)
JY992D94801
(separate volume)
(PDF files on CD-ROM
included with product)
(PDF files on CD-ROM
included with product)
Included with the screen
creation software
JY992D68301
(included with the screen
creation software)
JY992D98601
Describes the specifications, wiring, and
installation of F940GOT Series graphic
operation terminal. (hardware)
Describes the operation and use of the GOTF900 Series graphic operation terminals and
GT Designer2.
Describes the operation and use of the GOTF900 Series graphic operation terminals, GT
Designer and FX-PCS-DU/WIN-E.
Describes wiring and installation of the GOTF900 Series graphic operation terminals.
Describes the operation of GT Designer2
(SW*D5C-GTD2-E) and data transfer to the
GOT-900 Series.
Describes the specifications and setting of
object functions in GT Designer2 (SW*D5CGTD2-E).
Describes the operation of GT Designer
(SW*D5C-GOTR-PACKE) and data transfer to
the GOT-900 Series. (Refer to the help file)
Describes the operation of FX-PCS-DU/WINE screen creation software.
This manual contains explanations for
installation and operating procedure of F9GT40FMB data transfer adapter.
Manual NameManual NumberDescription
F9GT-40UMB
Manual
~
Indispensable manual
|
Either manual is necessary.
Refer if necessary, please.
JY992D74101
This manual contains explanations for
installation and operating procedure of F9GT40UMB data transfer adapter.
Refer to the manual of the connected programmable controller for details concerning that unit.
1. Introduction
The F940GOT-*WD-E (hereafter called “GOT” or “F940GOT”) is
to be mounted on the face of a control panel or operations panel,
and connected to the programming port (CPU port) or the
communication port (communication port) of a PLC.
Various devices can be monitored and PLC data changed via the
GOT screens. Several display screens are built-in to the GOT,
and additional personalized screens can be created by the user.
1) The GOT can connect to MELSEC FX, A, QnA and Q PLCs
as well as a host of third party manufactured units. Further
information can be found in GOT-F900 Series Hardware
Manual.
2) PLC user programs can be downloaded, uploaded and
monitored using programming software GX-Developer or FX-PCS/WIN-E on a personal computer via
the GOT. Further information can be found in the GOT-F900 Series Operation Manual.
3) Display screens are created using the following software.
Software NameVersion
GT Designer2
SWD5C-GTD2-E
GOT-F900 and GOT-A900 Series (for Windows) screen creation software.
GOT-F900 and GOT-A900 Series (for Windows) screen creation software.
SW1-A edition of SW1D5C-GOTR-PACKE or later
GOT-F900 Series (for Windows) screen creation software.
SW0PC-FXDU/WIN-E version 2.00 or later
1.1 Product Lists
Production NameDescription
F940GOT-SWD-EGraphic operation terminal main unit
F940GOT-LWD-E
SWD: 8 colors
LWD: White and black
Communication cable (GOT ↔ CPU port in FX
2NC
FX-50DU-CAB0
or FX
The connector on the GOT side is wired straight.
series PLC)
Cable length is 3m (9' 10").
Communication cable (GOT ↔ CPU port in FX
2NC
FX-50DU-CAB0/EN
or FX
series PLC)
The connector on the GOT side is wired straight. Cable length is 3m (9' 10").
Communication cable (GOT ↔ CPU port in FX
FX-50DU-CAB0-**M
or FX
The connector on the GOT side is wired straight.
series PLC)
2NC
** M is cable length. 1M: 1m (3' 3"), 10M: 10m (32' 9"), 20M: 20m (65' 7"),
30M: 30m (98' 5")
FX-40DU-CAB
Communication cable (GOT ↔ CPU port in FX, FX
The connector on the GOT side is wired straight. Cable length is 3m (9' 10").
Communication cable (GOT ↔ CPU port in FX, FX
FX-40DU-CAB-**M
The connector on the GOT side is wired straight.
** M is cable length. 10M: 10m (32' 9"), 20M: 20m (65' 7"), 30M: 30m (98' 5")
QC30R2
Communication cable (GOT ↔ CPU port in Q series PLC)
The connector on the GOT side is wired straight. Cable length is 3m (9' 10").
FX-232CAB-1Data exchange cable (GOT ↔ Personal computer <9-pin D-sub>)
PM-20BLBattery for Alarm history, sampling and current time data reter tion.
F9GT-40PSCTransparent protection sheet for F940GOT (5 pieces)
F9GT-40LTSBacklight for F940GOT
F9GT-40UMBData transfer adapter
F9GT-40FMBData transfer adapter (Flash memory built in)
Caution
During abnormal communication (including cable breakages) when monitor is executed within
the GOT, communication between the GOT and programmable controller CPU is interrupted.
It is then impossible to operate switches or devices in the PLC through the GOT.
Communication and normal operation resumes when the GOT system is correctly configured.
DO NOT configure emergency stop or safety features to operate through the GOT, and be
sure that there is no adverse consequences in the event of a GOT - PLC communications
malfunction.
P L C
P r o g r a m m i n g
p o r t
G O T
0
, FX0S, FX1S, FX0N, FX1N, FX2N
0
, FX0S, FX1S, FX0N, FX1N, FX2N
0
, FX0S, FX1S, FX0N, FX1N, FX2N
2C
, A or QnA series PLC)
2C
, A or QnA series PLC)
Note;
•Do not lay signal cables near high voltage power cables or allow them to share the same
trunking duct, otherwise, effects of noise or surge induction are likely to take please. Keep
a safe distance of more than 100 mm from these wires.
•Operate touch switches on the display screen by hand.
DO NOT use excessive force, or attempt operate them with hard or pointed objects.
The tip of a screw driver, pen or similar object for example may break the screen.
1.2 Dimensions and Each Part Name
Dimensions: mm (inches)MASS (Weight): 1 kg (2.2 lbs)
Dielectric Withstand Voltage 500 V AC > 1 min, tested between power terminals and ground
Insulation Resistance5 MΩ > at 500 V DC, tested between power terminals and ground
GroundGrounding resistance of 100 Ω or less. (class D)
ProtectionIP 65F
0 ~ 50 °C (32 ~ 122 °F)
[With expansion module: 0 ~ 40 °C (32 ~ 104 °F)]
Must be free of lamp black, corrosive gas, flammable gas, or excessive
amount of electroconductive dust particles and must be no direct
sunlight. (Same as for saving)
10 ~ 57 Hz: 0.075 mm Half Amplitude
57 ~ 150 Hz: 9.8 m/s
2
Acceleration
Sweep Count for X, Y, Z: 10 times (80 min. in each direction)
10 ~ 57 Hz: 0.035 mm Half Amplitude
57 ~ 150 Hz: 4.9 m/s
2
Acceleration
Sweep Count for X, Y, Z: 10 times (80 min in each direction)
2
Acceleration,
147m/s
3 times in each direction X, Y, and Z