MITSUMI
Remaining Battery Power Display MM1206
Electrical Characteristics
(Unless otherwise specified Ta=25°C, SW1=SW2=open)
Item Symbol Measurement Conditions Min. Typ. Max. Unit.
Current consumption II
CC VCC=3.0V 0.75 1.1 mA
Detection voltage IV
TH1VCC=H L 2.4 2.5 2.6 V
Detection voltage II V
TH2VCC=H L 2.16 2.25 2.34 V
Detection voltage difference V
T VT=VTH1
-
VTH2 210 250 290 mV
Detection voltage temperature factor V
TH/ T ±200
ppm/°C
Detection voltage I, Adjustment 1 + VT1 SW1=GND 70 100 130 mV
Detection voltage I, Adjustment 2
-
VT1 SW1=VCC
-
70-100-130 mV
Detection voltage II , Adjustment 1 + V
T2 SW2=GND 70 100 130 mV
Detection voltage II , Adjustment 2
-
VT2 SW2=VCC
-
70-100-130 mV
Output sink current II
S1VCC=2.7V, VCE=0.5V 5 10 mA
Output sink current II I
S2VCC=2.38V, VCE=0.5V 5 10 mA
Output sink current III I
S3VCC=2.0V, VCE=0.5V 5 10 mA
Output saturation voltage IV
CE1VCC=2.7V, ISINK=1mA 100 150 mV
Output saturation voltage II V
CE2VCC=2.38V, ISINK=1mA 100 150 mV
Output saturation voltage III V
CE3VCC=2.0V, ISINK=1mA 50 80 mV
Output leak voltage II
LE1VCC=2.3V, VCE=1.5V 1 µA
Output leak voltage II I
LE2VCC=2.7V, VCE=1.5V 1 µA
Output leak voltage II I
LE2' VCC=2.0V, VCE=1.5V 1 µA
Output leak voltage III I
LE3VCC=2.5V, VCE=1.5V 1 µA
Block Diagram, Example of Application Circuit
2.50V 2.25V
LED1 ON OFF OFF
LED2 OFF ON OFF
LED3 OFF OFF ON
Timing Chart