MITEL MH88422-1, MH88422S-1, MH88422S-2, MH88422S-3, MH88422-3 Datasheet

2-21
Features
FAX and Modem interf ace (V 29/V2 2 bis)
Variants mat ch Germ an, UK & 600
network
impedance s
Provides reinforced barrier to interna tional PTT requiremen ts
Transformerless 2-4 W ire conversion
Loop star t oper ation
Pulse and DT MF ope rati on
Accommo date s extern al mo nitor ph one
Line state detec tion out put s:
-loo p curr ent/ri nging outp uts
Single +5V operat ion, l ow idle po wer (5 mW)
Full Duplex
Suitable for p ower dow n ap plica tions
Applications
Interface to Central Office for:
•DAA
Modem
•FAX
Answering M achi ne
Terminal Equip men t
Description
The Mitel MH88422 Line Interface Circuit provides a complete audio and signalling link between audio equipment and central office. The functions provided by the MH88422 include 2-4 Wire conversion, loop seizure, ring voltage and loop current detection. The device is fabricated as thick film hybrid which incorporates various technologies for optimum circuit design, high voltage isolation and very high reliability.
Variants are provided to meet German (-1) and UK (-3) line impedance (see section on Line Impedances), as well as a 600 variants (-2).
ISSUE 5 April 1995
Ordering Information
MH88422 -1 14 Pin DIL Pac kage MH88422 -2 14 Pin DIL Packag e MH88422 -3 14 Pin DIL Packag e
Surface Mount Options are available by adding the
Suffix “S”
Power
Supply
Opto-
Isolation
Logic Inp ut
Buffer
Opto-
Isolation
Opto-
Isolation
Opto-
Isolation
Audio
Buffer
Audio Buffer
Ring &
Loop
Buffer
Transhybrid
Loss
Cancellat io n
Circuit
Active
Termina tio n
Audio Input
Buffer
Input Buffer
Isolation Barrier
VDD AGND
LC
VR
VX
RVLC
TIP
RING
TXIN
TF
RLS
USER CONNECTIONS
NETWORK CONNECTIONS
Figure 1 - Functional Block Diagram
MH88422
Line Interface Circuit
Preliminary Information
2-22
MH88422 Preliminary Information
Figure 2 - Pin Connections
Pin Description
Pin # Name Description
1VDDPositive Pow er Su pp ly Voltage. +5V. 2AGNDAnalog Ground. 4-Wire Ground. Normally connect ed to System Ground. 3LC
Loop Control (Input). A logic low activates internal circuitr y which provides a dc termination across Tip and Ring. Used for seizing the line and dial pulsing.
4RVLCRin g Voltage and Current Detect (Output). A logic low indicates that loop current is
detected. The loop current can be due to the external monitor phone or the MH88422 in the off-hook mode. The RVLC output pulses when the external monitor phone is dial pulsing or when the MH88422 is dial pulsing via the LC
input. In addition, when the MH88422 is on the on-hook mode, a pulsing output indicates ringing voltage across the Tip and Ring leads. The pulsing output frequency is twice the ringing frequency.
5NCNo Connection sho uld be mad e to this pin. 6VXTransmit (Outp ut ). 4-Wire ground (AGND) referenced audio out put , biased at 2.5V.
Outputs in off-h ook mode only.
7VRRecei ve (In pu t). 4-Wire ground (AG ND) referenced audio input , biased at 2.5V. LC
must be activated low and loop current must be flowing .
8NCNo Connection sho uld be mad e to this pin. 9 RING Ring Lead. Connects to the “Ring” lead of the central office through an opt iona l relay
contact. The central office “Tip” and “Ring” leads may be interchanged.
10 TXIN Transmit (Input). Connects to the “Ring” lead of the central offi ce through a coupli ng
capacitor.
11 TF Tip Feed. Connects to the “Tip” lead of the central office through an internal resistor and
an optional external resistor.
12 NC No Connection sho uld be made to thi s pin. 13 RLS Ring Loop Sense (Input). Sense node for ringing voltage detector and the loop current
detector.
14 TIP Tip Lead. Connects to the “Tip” lead of the central office through an optional relay
contact. The central office “Tip” and “Ring” leads may be interchanged.
RLS NC TF TXIN
LC
NC
TIP
AGND
RING
RVLC
NC
VX
VR
VDD
1 2 3 4 5
6 78
9
10
11
12
13
14
Preliminary Information MH88422
2-23
Functional Description
The MH88422 Line Interface Circuit is a COIC (Central Office Interface Circuit) used to interface FAX’s Modems or user defined equipment to Central Office 2-Wire Analog Trunks.
Opto-Isolation
The isolation barrier is designed to meet regulatory requirements for a reinforced barrier of 3kVac. It provides full isolation of mains voltages up to 250V RMS and all telecom voltages.
In order that this barrier is not bypassed a creepage/ clearance distance of 6.4mm minimum must be maintained between wiring, pcb tracking, etc., connected to external circuitry on either side of the barrier. To make this requirement simpler, pins on the MH88422 connected to opposite sides of the barrier are on opposite sides of the package.
External Protection Circuit
To meet regulatory high voltage requirement, an external protection circuit is required. The protection circuit shown in Figure 3 (Clamp Diode D1) is recommended.
DC Loop Termination
The DC loop termination circuitry provides the loop with an active DC load termination when a logic low is applied to the LC
(Loop Control) input. The termination is similar to a resistance of approximately 300 (loop current dependent). Internal optically isolated circuitry is used to switch the termination in and out the loop. This is used for both seizing the line as well as generating dial pulses. The MH88422 will not seize the line when powered down.
Supervision Features
The supervision circuitry is capable of detecting ringing voltage and loop current as well as the status of an optional external monitor phone. The RVLC (Ring Voltage Loop Current Detect) output provides a logic low when loop current flows due to the external monitor phone or the MH88422 being in the off-hook mo de .
The RVLC outputs pulses when the external monitor phone is dial pulsing or when the MH88422 is dial pulsing via the LC
mode.
In addition, when the MH88422 is on-hook, a pulsing output indicates that ringing voltage is across the tip and ring leads; the pulsing output frequency is twice the ringing frequency. See Figure 3.
Ringing frequency may require external validation. An RC monostable is usually satisfactory for this purpose or this may also be achieved using software applications.
2-4 Wire Conversion
The 2-4 Wire conversion circuit converts the balanced full duplex signal at Tip and Ring of the central office line into a transmit ground referenced signal at VX (Transmit) of the MH88422. It also converts the receive ground referenced signal at VR (Receive) of the MH88422 into a balanced transmit signal at Tip and Ring of the central office line.
In full duplex transmission, the Tip-Ring signal consists of an audio signal from the central office as well as an audio signal due to the VR input. There is an internal cancellation circuit which prevents the V
R
signal appearing at the VX output. The degree to which the 2-4 wire conver sion circuit min imizes the contribution of the VR signal at the VX output is specified as transhybrid loss (THL).
The MH88422 is suitable to drive a COMBO II codec or a VLSI modem device.
Line Impedance
The MH88422 provides a fixed Tip-ring impedance which conforms to the following PTT requirements.
MH88422-1 Zin = 200 + 820 // 115nF
Germany
MH88422-2 Zin = 600
MH88422-3 Zin = 370 + 620 // 310nF
UK
2-24
MH88422 Preliminary Information
.
* Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied
‡ Typical figures are at 25°C with nom inal +5V suppl y and are for design aid only
Loop Electrical Characteristics*
* Loop Electrical Characteristics are over recommended operating conditions unless otherwise stated. ‡ Typical figures are at 25°C and are for desi gn aid only. Note 1: All of the above characteristics use a test circuit as per Figure 3.
Absolute Maximum Ratings* - All voltages are with respect to AGND unless otherwise specified.
Parameter Symbol Min Max Units
1 DC Supply Voltage V
DD
-0.3 6 V
2 Storage Temperature T
S
-55 +80 °C
3 DC Loop Voltage V
Bat
-100 +100 V
4 Ringing Voltage V
R
- 120 V
RMS
5 Loop Current I
Loop
-90
mA
Recommended Operating Conditions.
Parameters Sym Min Typ
Max Units Test Conditions
1 DC Supply Voltages V
DD
4.5 5.0 5.5 V
2 Operating Temperature T
OP
070°C
3 Ringing Voltage V
R
75 V
RMS
V
Bat
=-48V
Characteristics Sym Min Typ
Max Units Test Conditions
1
Ringing Voltage No Detect
-1 Variant only Detect
VR
27
20 V
RMS
V
RMS
Refer to FT2 1TR2 for test method
Ringing Voltage No Detect All other Variants Detect
VR
14
7V
RMS
V
RMS
Externally Adjustable
2
Ringing Frequency 15 68 Hz
3
On-Hook 2-wire Impedance 40k 1kHz
4
Operating Loop Current 15 80 mA
5
Operating Loop Resista nce 2800 V
Bat
=-48V, I
Loop
=15mA
6
Off-Hook DC -1 Variant Voltage
-2 Variant
-3 Variant
6.0
6.0
4.0
4.0
6.0
6.0
9.6 15
6.0
7.8
9.0
12.5
V V V V V V
I
Loop
=25mA
I
Loop
=42mA
I
Loop
=15-20mA
I
Loop
=26mA
I
Loop
=25mA
I
Loop
=42mA
7
Leakage Current (2-Wire to AGND) 10 µA 100V
DC
8
Leakage Current on Hook (Tip to Ring)
910µAV
Bat
=-50V
9
DC Resistance during dialling
-1 variant only 200 220 I
Loop
=20-40mA
10
Dial Pulse Distort ion ON
-1 Variant OFF All other Variant
0
+6
0
+2 +8 +2
+4
+10
+4
ms ms ms
Loading...