![](/html/70/702c/702c82f4cb8fcc6485fc99c242d9ebc420bbeca505862220d2157ebdf7d40abd/bg1.png)
Last Information Update: 05 / 2013 - V 1.1
Introduction
Thank you for purchasing a Miomare product. The Miomare
shower thermometer (A) allows you to adjust the water
temperature in the shower to meet your needs exactly due to
the large, easily readable LCD display (3). The alarm LED (2),
which is activated at temperatures above 41°C, increases
safety, especially for babies, children and seniors. The shower
thermometer (A) is suitable for all standard showers and is
easy to install. It also helps you to save energy.
Intended use
This shower thermometer (A) is not designed for commercial
use or installation and operation in a company. This shower
thermometer (A) may only be used for private purposes, and
any other use is not as intended.
This shower thermometer (A) meets all relevant norms and
standards related to CE conformity. In the event of any
modification to the shower thermometer (A) that was not
approved by the manufacturer, compliance with these
standards is no longer guaranteed. The manufacturer does not
accept any liability for any resulting damage or faults in such
cases. Please observe the regulations and laws in the country
of use.
Supplied items
A Shower thermometer
B 2 x 1.5V batteries LR44
C Rubber inlet seal (1mm)
D Rubber outlet seal (2.1mm)
E These operating instructions (symbolic representation)
Technical data
Power supply 2 x 1.5V batteries LR44
LCD display area 0°C – 69°C
Connection standard thread 1/2 inch
Measuring accuracy
Operating temperature 0°C to +50°C
Storage temperature 0°C to +50°C
Alarm function
Energy-saving mode
Protection class IPX7
Dimensions (W x H x D) approx. 2.8 x 7.0 x 2.9 cm
Weight (without batteries) approx. 31g
The technical data and design may be changed without
notification.
+/- 1°C (in the measuring
range from 25°C to 50°C)
+/- 1.5°C (in the measuring
range from 0°C to 24°C
and from 51°C to 69°C)
alarm LED (2) flashes at
temperatures >41°
display auto-off after 60
minutes +/- 5 minutes
Safety instructions
Before using the shower thermometer (A) for the first time,
please read the following instructions carefully even if you are
familiar with using electronic devices. Store these operating
instructions in a safe place for future reference. If you pass on
the shower thermometer (A) to someone else, be sure to
always include these operating instructions.
This symbol indicates important information for safe
operation of the shower thermometer (A) and the
safety of the user.
Copyright
All information contained in these instructions is subject to
copyright and is provided for information purposes only. It is
only permitted to copy or duplicate data and information with
the express and written consent of the author. This also
includes commercial use of the content and data. The text and
illustrations are based on the state of the art at the time of
printing.
Operating environment
This shower thermometer (A) must not be
connected to a low-pressure boiler. Before
connecting, contact your plumber if necessary.
The shower thermometer (A) is suitable for use in all standard
showers with a ½ inch connection. It is designed for use in
rooms with a high temperature or humidity.
Ensure that
no direct heat sources (e.g. heating) can affect the shower
thermometer (A) because it may be damaged otherwise.
the shower thermometer (A) is not exposed to direct sunlight
or bright artificial light because it may be damaged
otherwise.
the shower thermometer (A) is not subject to strong vibrations
because it may be damaged otherwise.
no foreign bodies penetrate the shower thermometer (A)
because it may be damaged otherwise.
no fire sources (e.g. burning candles) are placed on or near
the shower thermometer (A) because there is a risk of fire.
contact with corrosive liquids is prevented because the
shower thermometer (A) may be damaged otherwise.
you do not throw batteries into fire, short-circuit or recharge
them. Risk of explosion!
you wear chemical-resistant protective gloves and goggles
when handling leaking batteries as there is a risk of chemical
burns.
Children and persons with
disabilities
Electrical devices do not belong in the hands of children.
Persons with disabilities should also only use electrical devices
appropriately. Never allow children or persons with disabilities
to use electrical devices unsupervised. They may not recognise
potential risks. Batteries and other small parts may cause
choking resulting in death or serious injury. Also always keep
plastic packaging out of reach as it poses a suffocation risk.
Overview
1 Union nut
2
larm LED
3LCD display
4 Shower hose connection
5 Battery compartment cover
6Screw
![](/html/70/702c/702c82f4cb8fcc6485fc99c242d9ebc420bbeca505862220d2157ebdf7d40abd/bg2.png)
First use
Installation
Insert two 1.5V batteries LR44 (B) in the shower thermometer
(A). Note the "Replacing the batteries" section for this
purpose.
Remove the shower head from the shower hose.
Screw the union nut (1) of the shower thermometer with the
inserted rubber outlet seal (D) on the thread of the shower
head.
Then screw the union nut of the shower hose with the
inserted rubber inlet seal (C) on the shower hose connection
(4) of the shower thermometer (A).
The shower thermometer (A) is then ready for operation.
Application
The response time for a reliable temperature
measurement is up to 4 seconds.
The water temperature is indicated in °C on the LCD display
(3) while showering.
From a water temperature of 41°C, the alarm LED (2)
flashes red above the display. At the same time, " "
flashes on the LCD display (3).
If the temperature of the running water increases to over
69°C, " " is indicated on the LCD display (3) because
the measuring range of the shower thermometer (A) is
exceeded.
Energy-saving mode
The display is switched off when not in use.
To deactivate the energy-saving mode, move the shower
thermometer (A) slightly. The display then indicates the
current temperature again.
Replacing the batteries
If it is necessary to change the two 1.5V
batteries LR44 (B), you must ensure that only
batteries of the same type are used (see
technical data).
If the LCD display (3) becomes weaker, the two 1.5V batteries
LR44 (B) must be replaced. In this case, proceed as follows:
Open the battery compartment on the back of the shower
thermometer (A) by removing the screw (6) using a size 0
Phillips screwdriver.
Remove the battery compartment cover (5) by inserting a
thin, pointed object (e.g. a paper clip) in the available screw
hole and removing the battery compartment cover (5) on this
side.
In the battery compartment, there are markings (+ and -)
next to the battery contact springs for inserting the batteries
with the correct polarity.
Then insert two new 1.5V batteries LR44 (B). You must
ensure that the batteries are inserted with the correct
polarity:
The "+" marking in the battery compartment indicates that
the plus pole of the battery must be inserted downwards.
The "-" marking in the
battery compartment indicates that the minus pole of the
battery must be inserted downwards.
Then replace the battery compartment cover (5) and tighten
the screw (6) again.
Replace weak batteries as soon as possible to
avoid leakage. Never use old and new batteries
or batteries of different types at the same time.
Cleaning / maintenance
The shower thermometer (A) does not contain any parts that
require servicing or cleaning. Ensure that the shower
thermometer (A) does not become dirty.
Clean the shower thermometer (A) with a damp
cloth if it becomes dirty. Do not use any solvents,
corrosive or gaseous cleaning agents. The
shower thermometer (A) may be damaged
otherwise.
Environmental and disposal information
When the crossed out wheelie bin symbol
appears on a product, this indicates that the
product is subject to the European Directive
2002/96/EC.
All old electrical and electronic devices must be separated
from normal household waste and disposed of at designated
state facilities. The proper disposal of the old device helps to
avoid environmental damage and personal health hazards.
For further information about proper disposal, contact your
local authorities, waste disposal office or the shop where you
bought the device.
Disposal of the packaging
Dispose of the packaging in an environmentally compatible
manner. Cardboard can be put out for municipal paper
collections or brought to public collection points for recycling.
Films and plastic used for packaging the device are collected
by your local disposal services and disposed of in an
environmentally compatible manner.
Disposal of batteries
Remember to protect the environment. Used batteries should
not be disposed of in domestic waste. They must be taken to a
collection point for old batteries. Please note that only
discharged batteries may be deposited in collection bins for
portable batteries. Care must be taken to ensure that batteries
that are not fully discharged do not short circuit.
Conformity information
This shower thermometer (A) meets the basic
requirements and other relevant regulations of
the EMC Directive 2004/108/EC as well as the
RoHS Directive 2011/65/EU.
Warranty and servicing advice
Warranty of TARGA GmbH
This device is sold with three years warranty from the date of
purchase. Please keep the original receipt in a safe place as
proof of purchase. Before using your product for the first time,
please read the enclosed documentation or online help.
Should any problems arise which cannot be solved in this way,
please call our hotline. Please have the article number and, if
available, the serial number to hand for all enquiries. If it is not
possible to solve the problem on the phone, our hotline support
staff will initiate further servicing procedures depending on the
fault. Within the warranty period the product will be repaired
or replaced free of charge as we deem appropriate. No new
warranty period commences if the product is repaired or
replaced. Consumables such as batteries, rechargeable
batteries and lamps are not covered by the warranty.
Your statutory rights towards the seller are not affected or
restricted by this warranty.
Service
Phone: 0207 – 36 50 744
E-Mail: service.GB@targa-online.com
Phone: 01 – 242 15 83
E-Mail: service.IE@targa-online.com
Phone: 800 – 62 175
E-Mail: service.MT@targa-online.com
Phone: 800 – 92 496
E-Mail: service.CY@targa-online.com
IAN: 91063
Manufacturer
TARGA GmbH
Coesterweg 45
59494 SOEST
GERMANY