Minuteman UPS ALLIANCE User Manual

ALLIANCE SERIES
OWNER'S MANUAL
TABLE OF CONTENTS
1. INTRODUCTION ……………………………………………………………....
1
2. RECEIVING INSPECTION …………………………………………………. 1
3. WARRANTY REGISTRATION ……………………………………………... 1
4. IMPORTANT SAFETY INSTRUCTIONS …………………………………... 1
5. ELECTRICAL SPECIFICATIONS …………………………………………… 3
6. TYPICAL RUN TIME VERSUS LOAD ……………………………………… 5
7. PHYSICAL SPECIFICATIONS ……………………………………………… 5
8. UNIT DESCRIPTION ………………………………………………………… 6
9. INSTALLATION AND TEST ………………………………………………… 7
10. OPERATION …………………………………………………………………... 8
11. SYSTEM BATTERIES ……………………………………………………...… 8
12. BATTERY/SYSTEM CHECKOUT …………………………………………... 9
13. UPS MONITORING CONFIGURATIONS ………………………………….. 9
14. UPS DB9 PIN OUT ……………………………………………………………. 9
15. SERVICE ……………………………………………………………………….. 10
16. UPS PROBLEM CHART ……………………………………………………… 10
17. POLICY AND INSTRUCTIONS FOR RETURN OF PRODUCT …………. 11
INTRODUCTION
The MINUTEMAN ALLIANCE Series Uninterruptible Power Supply (UPS) has been designed to be maintenance-free, and to provide years of excellent service. It will provide superior power protection for personal computers, telephone systems and other critical electronic equipment against all commercial power anomalies. Output waveform is a synchronized, simulated sinewave. Both LED and audible alarms indicate UPS and commercial power status at all times. Other features include:
Light weight and small footprint.
Quiet operation.
Excellent non-linear current capability.
LAN communications port (except A300).
Automatic UPS test at turn-on.
Site wiring fault indication (120 VAC models).
Low voltage boost to facilitate low commercial voltage operation without battery utilization (except A300/A425).
Transfer voltage adjustment switches (except A300/A425).
RECEIVING INSPECTION
SAVE THE PACKING MATERIALS!
Remove and inspect the unit for shipping damage. If damage is found, immediately notify the carrier and your dealer. If no damage is found, save both the shipping container and the packing foam in case of a later need to return the unit to the factory, or ship it to another location.
WARRANTY REGISTRATION
Complete the warranty registration card provided in the back of this manual and mail it within ten days of receipt to register your warranty.
Failure to register your warranty renders it non-valid.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Read this manual carefully before operating the UPS. All instructions should be followed during installation and maintenance of the UPS and batteries.
1
These UPS units are intended for use in a temperature-controlled, indoor area free of conductive contaminants. Select a location, which will provide good air circulation for the UPS at all, times. Avoid locations near heating devices, water or excessive humidity, or where unit is exposed to direct sunlight. Route power cords so they cannot be walked on or damaged.
CAUTION
may be electrically hot even when the UPS is not connected to commercial power. Trained service personnel should perform all repairs, since an electrical shock hazard exists.
CAUTION
-- The UPS uses batteries for generating AC voltages, so output receptacles
-- Do not remove the cover -- there are no user-serviceable parts inside.
CAUTION
chassis. Plug the UPS into a 3-wire grounding type, commercial receptacle with the grounding conductor connected to earth ground at the service equipment. Removal of the ground pin from the plug or use of a 3-wire-to-2-wire adapter will defeat this safety feature and may result in a shock hazard. Additionally, if the plug is removed to simulate a power failure (not recommended), do not touch the plug conductors or the chassis while the plug is removed. On 120-volt models, improperly connected power will indicate a Site Wiring Fault.
CAUTION
immediately turn the unit power switch off and unplug the MINUTEMAN from the commercial receptacle.
Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from the batteries.
When replacing UPS batteries, use the same number of sealed lead-calcium rechargeable batteries with the same voltage and ampere-hour ratings as those in the UPS. These batteries have pressure operated safety vents.
CAUTION
CAUTION
and eyes and may be toxic.
-- To prevent electrical shock, the 3-wire plug provides earth ground for the UPS
-- Do not allow water or any foreign object to enter the UPS. In case this occurs,
-- Do not dispose of batteries in a fire. They may explode.
-- Do not open or mutilate batteries. Release electrolyte is harmful to the skin
CAUTION
battery system can still present a risk. The current capability of a battery is sufficient to burn wire or tools very rapidly, producing molten metal. Observe these precautions when working on batteries:
-- Although battery system voltages are only 12 VDC, 24 VDC and 36 VDC, the
1. Turn the UPS off and disconnect it form the wall outlet prior to connecting or disconnecting battery terminals;
2. Remove watches, rings or other metal objects;
3. Use tools with insulated handles;
4. Wear protective gloves and eyewear;
5. Do not lay tools or other metal parts on top of batteries.
2
ELECTRICAL SPECIFICATIONS
MAX. HEAT
DISSIPATION
BATTERY
RATED
MODEL #
A300 300 190 60 120/2.6 120/2.5 12 160 10
A300/2 300 190 50 220/1.5 220/1.4 12 160 10
A425 425 275 60 120/3.6 120/3.5 12 235 10
A425/2 425 275 50 220/2.0 220/1.9 12 235 10
A500 500 325 60 120/4.3 120/4.2 12 275 65*
A500/2 500 325 50 220/2.6 220/2.3 12 275 65*
A750 750 500 60 120/6.5 120/6.3 24 425 105*
A750/2 750 500 50 220/3.4 220/3.4 24 425 105*
A900 900 630 60 120/8.8 120/7.5 24 540 130*
A900/2 900 630 50 220/4.2 220/4.1 24 540 130*
A1250 1250 900 60 120/12.1 120/10.4 24 770 185*
A1250/2 1250 900 50 220/5.8 220/5.7 24 770 185*
A2000 1440 1400 60 120/12 120/12 36 1200 300* A2000-41 1900 1400 60 120/16 120/15.8 36 1200 300* A2000-43 1900 1400 60 120/16 120/15.8 36 1200 300* A2000-44 2000 1400 60 120/20 120/16.7 36 1200 300*
A2000/2 2000 1400 50 220/10 220/9.1 36 1200 300*
VA
OUTPUT
WATTS
FREQ
Hz
INPUT VAC/A
OUTPUT
VAC/A
SYSTEM
VDC
BTU/Hr
INVERTER
MODE
AC
MODE
* With maximum boost and maximum charge current.
NOTE:
compatible with 220VAC, 230VAC and 240VAC utility systems. UPS inverter output supplies 225 VAC. Other output voltages can be factory-set on a special-order basis.
220VAC, 50 Hz models supply an output voltage of 220VAC, making them
3