Milwaukee M18 FFSDC16 Operator's Manual

Cat. No.
M18 FFSDC16
M18™ FUEL™ SWITCH PACK™ SECTIONAL DRUM SYSTEM
OPERATOR'S MANUAL
To reduce the risk of injury, user must read and understand operator's manual.
WARNING
GENERAL POWER TOOL
SAFETY WARNINGS
WARNING
Read all safety warnings, instruc­tions, illustrations and specifica-
tions provided with this power tool. Failure to follow
all instructions listed below may result in electric shock,
Save all warnings and in-
structions for future reference. The term "power tool"
in the warnings refers to your mains-operated (corded) power tool or battery-operated (cordless) power tool.
WORK AREA SAFETY
Keep work area clean and well lit. Cluttered or dark
areas invite accidents.
Do not operate power tools in explosive atmo-
liquids, gases or dust. Power tools create sparks
which may ignite the dust or fumes.
Keep children and bystanders away while operat-
ing a power tool. Distractions can cause you to lose
control.
ELECTRICAL SAFETY
Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any adapter plugs with earthed (grounded) power tools. Un-
of electric shock.
Avoid body contact with earthed or grounded
surfaces, such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric
shock if your body is earthed or grounded.
Do not expose power tools to rain or wet condi-
tions. Water entering a power tool will increase the
risk of electric shock.
Do not abuse the cord. Never use the cord for car-
rying, pulling or unplugging the power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk
of electric shock.
When operating a power tool outdoors, use an
extension cord suitable for outdoor use. Use of a
cord suitable for outdoor use reduces the risk of electric shock.
If operating a power tool in a damp location is
unavoidable, use a ground fault circuit interrupter (GFCI) protected supply. Use of an GFCI reduces
the risk of electric shock.
PERSONAL SAFETY
Stay alert, watch what you are doing and use com-
mon sense when operating a power tool. Do not use a power tool while you are tired or under the
A moment of inattention while operating power tools may result in serious personal injury.
Use personal protective equipment. Always wear
eye protection. Protective equipment such as a dust
mask, non-skid safety shoes, hard hat or hearing protection used for appropriate conditions will reduce personal injuries.
Prevent unintentional starting. Ensure the switch
is in the off-position before connecting to power source and/or battery pack, picking up or carrying the tool.
switch or energising power tools that have the switch on invites accidents.
Remove any adjusting key or wrench before turn-
ing the power tool on. A wrench or a key left attached
to a rotating part of the power tool may result in per­sonal injury.
Do not overreach. Keep proper footing and balance
at all times. This enables better control of the power
tool in unexpected situations.
Dress properly. Do not wear loose clothing or
jewelry. Keep your hair and clothing away from moving parts. Loose clothes, jewelry or long hair can
be caught in moving parts.
If devices are provided for the connection of dust
extraction and collection facilities, ensure these are connected and properly used. Use of dust col-
lection can reduce dust-related hazards.
Do not let familiarity gained from frequent use
of tools allow you to become complacent and ignore tool safety principles. A careless action can
cause severe injury within a fraction of a second.
POWER TOOL USE AND CARE
Do not force the power tool. Use the correct power
tool for your application. The correct power tool will
do the job better and safer at the rate for which it was designed.
Do not use the power tool if the switch does not turn
it on and off. Any power tool that cannot be controlled
with the switch is dangerous and must be repaired.
Disconnect the plug from the power source and/
or remove the battery pack, if detachable, from the power tool before making any adjustments, changing accessories, or storing power tools. Such
preventive safety measures reduce the risk of starting the power tool accidentally.
Store idle power tools out of the reach of children
and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool.
Power tools are dangerous in the hands of untrained users.
Maintain power tools and accessories. Check for
misalignment or binding of moving parts, breakage of parts and any other condition that may affect the power tool’s operation. If damaged, have the power tool repaired before use. Many accidents are caused
by poorly maintained power tools.
Keep cutting tools sharp and clean. Properly main-
tained cutting tools with sharp cutting edges are less likely to bind and are easier to control.
Use the power tool, accessories and tool bits etc.
in accordance with these instructions, taking into account the working conditions and the work to be performed. Use of the power tool for operations
different from those intended could result in a hazard­ous situation.
Keep handles and grasping surfaces dry, clean
and free from oil and grease. Slippery handles
and grasping surfaces do not allow for safe handling and control of the tool in unexpected situations.
BATTERY TOOL USE AND CARE
manufacturer. A charger that is suitable for one type
another battery pack.
battery packs. Use of any other battery packs may
When battery pack is not in use, keep it away from
other metal objects, like paper clips, coins, keys, nails, screws or other small metal objects, that can make a connection from one terminal to another.
Shorting the battery terminals together may cause
Under abusive conditions, liquid may be ejected
from the battery; avoid contact. If contact ac-
Place the drain cleaner at a distance no greater
cleaner cannot be placed within 610mm from the drain opening, the drain opening will need to be
Greater distances can cause control problems leading to twisting, kinking, breaking or whipping of the cable.
One person must control both the trigger switch
and cable. If the tool stops rotating, the user must be
able to turn the tool off to prevent twisting, kinking, breaking or whipping of the cable.
Do not operate the drain cleaner in reverse rotation
except as described in this manual. Running the tool
in reverse for extended periods can cause damage to the cable and accessories.
WARNING
-
jury, and product damage due to a
short circuit, never immerse your tool, battery pack or
certain industrial chemicals, and bleach or bleach containing products, etc., can cause a short circuit.
Maintain labels and nameplates. These carry im-
portant information. If unreadable or missing, contact
a MILWAUKEE service facility for a replacement.
WARNING
Some dust created by power sanding,
sawing, grinding, drilling, and other construction activities contains chemicals known to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are:
lead from lead-based paint crystalline silica from bricks and cement and other
masonry products, and
arsenic and chromium from chemically-treated lumber. Your risk from these exposures varies, depending on
how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to
SPECIFICATIONS
Cat. No. ...............................................M18 FFSDC16
Volts ...................................................................18 DC
No Load RPM ........................................................ 250
Battery Type ..................................................... M18™
Charger Type .................................................... M18™
Drain Line Capacity..................................Up to 30.5m
Cable Range..........................8mm-16mm (5/16"-5/8")
Tool Weight (With Battery)..................................7.8kg
SYMBOLOGY
Volts
V
Direct Current
No-Load Revolutions per Minute (RPM)
Do not allow battery to contact corrosive
Only wear leather gloves
Do not transport this tool when the drum and backpack are connected
-
tacts eyes, additionally seek medical help. Liquid
ejected from the battery may cause irritation or burns.
Do not use a battery pack or tool that is damaged or
risk of injury.
-
cessive temperature.
above 130°C (265°F) may cause explosion.
Follow all charging instructions and do not charge
the battery pack or tool outside the temperature
Charging im-
SERVICE
person using only identical replacement parts.
This will ensure that the safety of the power tool is maintained.
Never service damaged battery packs. Service of
battery packs should only be performed by the manu­facturer or authorised service providers.
SPECIFIC SAFETY RULES
Only grasp the rotating cable with gloves recom-
mended by the manufacturer.
gloves or rags can become wrapped around the cable and may result in serious personal injury.
Do not allow the cutter to stop turning while the
cable is turning. This can overstress the cable and
may cause twisting, kinking or breaking of the cable and may result in serious personal injury.
Use latex or rubber gloves inside the gloves rec-
ommended by the manufacturer, goggles, face shields, protective clothing, and respirator when chemicals, bacteria or other toxic or infectious sub­stances are suspected to be in a drain line. Drains
may contain chemicals, bacteria and other substances that may cause burns, be toxic or infectious or may result in other serious personal injury.
Practice good hygiene. Do not eat or smoke while
handling or operating the tool. After handling or operating drain cleaning equipment, use hot, soapy water to wash hands and other body parts exposed to drain contents. This will help reduce the risk of health
hazards due to exposure to toxic or infectious material.
Only use the drain cleaner for the recommended
drain sizes. Using the wrong size drain cleaner can
lead to twisting, kinking or breaking of the cable and may result in personal injury.
Inspect cable for wear and damage before use.
Replace a worn or damaged cable before using the drain cleaner.
Do not twist, kink or over bend cables. Breaking of
the cable may result in serious personal injury.
Inspect the drain to be cleaned before use. If pos-
sible, determine the access point(s) to the drain, the size(s) and length(s) of the drain, distance to mainlines, the nature of the blockage, presence of drain clean­ing chemicals or other chemicals, etc. If chemicals are present in the drain, it is important to understand
those chemicals. Contact the chemical manufacturer for required information.
If needed, place protective covers in the work area.
The drain cleaning process can be messy.
Make sure cable is fully retracted inside of the drain
cleaner. This will prevent whipping at start up.
than 610mm from drain opening. If the drain
®
noxxxxmin.
-1
Regulatory Compliance mark (RCM). This product meets applicable regulatory requirements.
Loading...