Miller Electric 4500, Blu-Fab 3500 User Manual

Page 1
OM-221 677C 200607
Effective with serial number 222 842
Processes
MIG (GMAW) Welding Flux Cored (FCAW)
Description
Blu-Fab 3500
and 4500 Series
OWNER’S MANUAL
Page 2
From Miller to You
Thank you and congratulations on choosing Miller. Now you can get the job done and get it done right. We know you don’t have time to do it any other way.
That’s why when Niels Miller first started building arc welders in 1929, he made sure his products offered long-lasting value and superior quality. Like you, his customers couldn’t afford anything less. Miller products had to be more than the best they could be. They had to be the best you could buy.
Today, the people that build and sell Miller products continue the tradition. They’re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929.
This Owner’s Manual is designed to help you get the most out of your Miller products. Please take time to read the Safety precautions. They will help you protect yourself against potential hazards on the worksite. We’ve made installation and operation quick and easy. With Miller you can count on years of reliable service with proper maintenance. And if for some reason the unit needs repair, there’s a Troubleshooting section that will help you figure out what the problem is. The parts list will then help you to decide which exact part you may need to fix the problem. Warranty and service information for your particular model are also provided.
Working as hard as you do
every power source from Miller is backed by the most hassle-free warranty in the business.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets.
Page 3
TABLE OF CONTENTS
SECTION 1 − SAFETY PRECAUTIONS−READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols for Installation, Operation, and Maintenance 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. EMF Information 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 DEFINITIONS 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 INTRODUCTION 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Included with Your Unit 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Specifications 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3. Duty Cycle Chart 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4. Volt-Ampere Curves 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 INSTALLATION 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Selecting a Location 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Typical MIG Connections 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Electrical Service Guide 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Connecting Input Power 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Remote 14 Receptacle RC1 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6. Connecting Welding Gun And Weld Cable 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. Installing Wire Guide And Drive Roll 9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 OPERATION 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Controls 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Panel Controls 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Run-In Control and Burnback Control 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 MAINTENANCE AND TROUBLESHOOTING 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1. Routine Maintenance 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Troubleshooting 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 - ELECTRICAL DIAGRAM 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 8 - PARTS LIST 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARRANTY
Page 4
Declaration of Conformity for
European Community (CE) Products
NOTE
Manufacturer: European Contact:
ITW Welding Products Italy S.r.l. Mr. Danilo Fedolfi, Via Privata Iseo 6/E Managing Director 20098 San Giuliano ITW Welding Products Italy S.r.l. Milanese, Italy Via Privata Iseo 6/E Phone: 39(02)98290-1 20098 San Giuliano
European Contact Signature:
Declares that this product: Blu-Fab 3500/4500
conforms to the following Directives and Standards:
This information is provided for units with CE certification (see rating label on unit).
Milanese, Italy Phone: 39(02)98290-1 Fax: 39(02)98290203
Directives
Electromagnetic Compatibility Directives: 89/336/EEC
Low Voltage: 73/23/EEC
Machinery Directives: 98/37/EEC
And their amendments 91/368/EEC, 92/31/EEC, 93/44/EEC, 93/68/EEC
Standards
Electromagnetic compatibility (EMC) Product standard for arc welding equipment: EN50199: August 1995
Safety Requirements for Arc Welding Equipment Part 1: EN 60974-1: 1989
The product technical file is maintained by the responsible Business Unit(s) located at the manufacturing facility.
dec_stat_Milan_6/05
Page 5
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING
eng_som_woPPS_3/05
Y Warning: Protect yourself and others from injury — read and follow these precautions.
1-1. Symbol Usage
Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.
Y Marks a special safety message.
. Means “Note”; not safety related.
1-2. Arc Welding Hazards
Y The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see the symbol, watch out, and follow the related instructions to avoid the hazard. The safety information given below is only a summary of the more complete safety information found in the Safety Standards listed in Section 1-4. Read and follow all Safety Standards.
Y Only qualified persons should install, operate, maintain, and
repair this unit.
Y During operation, keep everybody, especially children, away.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks or severe burns. The electrode and work circuit is electrically live whenever the output is on. The input
live when power is on. In semiautomatic or automatic wire welding, the wire, wire reel, drive roll housing, and all metal parts touching the welding wire are electrically live. Incorrectly installed or improperly grounded equipment is a hazard.
D Do not touch live electrical parts. D Wear dry, hole-free insulating gloves and body protection. D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process. D If AC output is required, use remote output control if present on
unit.
D Additional safety precautions are required when any of the follow-
ing electrically hazardous conditions are present: in damp locations or while wearing wet clothing; on metal structures such as floors, gratings, or scaffolds; when in cramped positions such as sitting, kneeling, or lying; or when there is a high risk of unavoid­able or accidental contact with the workpiece or ground. For these conditions, use the following equipment in order presented: 1) a semiautomatic DC constant voltage (wire) welder, 2) a DC manual (stick) welder, or 3) an AC welder with reduced open-circuit volt­age. In most situations, use of a DC, constant voltage wire welder is recommended. And, do not work alone!
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D Always verify the supply ground − check and be sure that input
power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet.
D When making input connections, attach proper grounding conduc-
tor first double-check connections.
D Frequently inspect input power cord for damage or bare wiring
replace cord immediately if damaged bare wiring can kill.
power circuit and machine internal circuits are also
This group of symbols means Warning! Watch Out! possible ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the hazards.
D Turn off all equipment when not in use. D Do not use worn, damaged, undersized, or poorly spliced cables. D Do not drape cables over your body. D If earth grounding of the workpiece is required, ground it directly
with a separate cable.
D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Do not touch electrode holders connected to two welding ma-
chines at the same time since double open-circuit voltage will be present.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D Wear a safety harness if working above floor level. D Keep all panels and covers securely in place. D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal.
SIGNIFICANT DC VOLTAGE exists in inverter-type welding power sources after removal of input power.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section before touching any parts.
FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health.
D Keep your head out of the fumes. Do not breathe the fumes. D If inside, ventilate the area and/or use local forced ventilation at the
arc to remove welding fumes and gases.
D If ventilation is poor, wear an approved air-supplied respirator. D Read and understand the Material Safety Data Sheets (MSDSs)
and the manufacturer’s instructions for metals, consumables, coatings, cleaners, and degreasers.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watch­person nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breath­ing air is safe.
D Do not weld in locations near degreasing, cleaning, or spraying op-
erations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases.
D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded.
OM-221 677 Page 1
Page 6
ARC RAYS can burn eyes and skin.
BUILDUP OF GAS can injure or kill.
Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld.
D Wear an approved welding helmet fitted with a proper shade of fil-
ter lenses to protect your face and eyes when welding or watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash,
glare and sparks; warn others not to watch the arc.
D Wear protective clothing made from durable, flame-resistant mate-
rial (leather, heavy cotton, or wool) and foot protection.
WELDING can cause fire or explosion.
Welding on closed containers, such as tanks, drums, or pipes, can cause them to blow up. Sparks can fly off from the welding arc. The flying sparks, hot
burns. Accidental contact of electrode to metal objects can cause sparks, explosion, overheating, or fire. Check and be sure the area is safe before doing any welding.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Do not weld where flying sparks can strike flammable material. D Protect yourself and others from flying sparks and hot metal. D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby. D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see Safety Standards).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly unknown paths and causing electric shock, sparks, and fire hazards.
D Do not use welder to thaw frozen pipes. D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
D Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B
for hot work and have a fire watcher and extinguisher nearby.
workpiece, and hot equipment can cause fires and
FLYING METAL can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool, they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.
D Shut off shielding gas supply when not in use. D Always ventilate confined spaces or use
approved air-supplied respirator.
HOT PARTS can cause severe burns.
D Do not touch hot parts bare handed. D Allow cooling period before working on gun or
torch.
D To handle hot parts, use proper tools and/or
wear heavy, insulated welding gloves and clothing to prevent burns.
MAGNETIC FIELDS can affect pacemakers.
D Pacemaker wearers keep away. D Wearers should consult their doctor before
going near arc welding, gouging, or spot welding operations.
NOISE can damage hearing.
Noise from some processes or equipment can damage hearing.
D Wear approved ear protection if noise level is
high.
CYLINDERS can explode if damaged.
Shielding gas cylinders contain gas under high pressure. If damaged, a cylinder can explode. Since gas cylinders are normally part of the welding process, be sure to treat them carefully.
D Protect compressed gas cylinders from excessive heat, mechani-
cal shocks, physical damage, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits. D Never drape a welding torch over a gas cylinder. D Never allow a welding electrode to touch any cylinder. D Never weld on a pressurized cylinder explosion will result. D Use only correct shielding gas cylinders, regulators, hoses, and fit-
tings designed for the specific application; maintain them and associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve. D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Use the right equipment, correct procedures, and sufficient num-
ber of persons to lift and move cylinders.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and Compressed Gas Association (CGA) publication P-1 listed in Safety Standards.
OM-221 677 Page 2
Page 7
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING UNIT can cause injury.
D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of unit.
OVERUSE can cause OVERHEATING
D Allow cooling period; follow rated duty cycle. D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.
STATIC (ESD) can damage PC boards.
READ INSTRUCTIONS.
D Read Owner’s Manual before using or servic-
ing unit.
D Use only genuine Miller/Hobart replacement
parts.
H.F. RADIATION can cause interference.
D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
D The user is responsible for having a qualified electrician prompt-
ly correct any interference problem resulting from the installa­tion.
D If notified by the FCC about interference, stop using the
equipment at once.
D Have the installation regularly checked and maintained. D Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to minimize the possibility of interference.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.
MOVING PARTS can cause injury.
D Keep away from moving parts. D Keep away from pinch points such as drive
rolls.
WELDING WIRE can cause injury.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading welding wire.
MOVING PARTS can cause injury.
D Keep away from moving parts such as fans. D Keep all doors, panels, covers, and guards
closed and securely in place.
D Have only qualified persons remove doors,
panels, covers, or guards for maintenance as necessary.
D Reinstall doors, panels, covers, or guards
when maintenance is finished and before re­connecting input power.
ARC WELDING can cause interference.
D Electromagnetic energy can interfere with
sensitive electronic equipment such as computers and computer-driven equipment such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
D To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
D Locate welding operation 100 meters from any sensitive elec-
tronic equipment.
D Be sure this welding machine is installed and grounded
according to this manual.
D If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables, using line filters, or shielding the work area.
For Gasoline Engines: Y Engine exhaust contains chemicals known to the State of
California to cause cancer, birth defects, or other reproductive harm.
For Diesel Engines: Y Diesel engine exhaust and some of its constituents are known
to the State of California to cause cancer, birth defects, and other reproductive harm.
OM-221 677 Page 3
Page 8
1-4. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).
Recommended Safe Practices for the Preparation for Welding and Cut­ting of Containers and Piping, American Welding Society Standard
AWS F4.1 from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).
National Electrical Code, NFPA Standard 70, from National Fire Protec­tion Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA 022699101 (phone: 6177703000, website: www.nfpa.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 1735 Jefferson Davis Highway, Suite 1004, Arlington, VA 222024102 (phone: 7034120900, web­site: www.cganet.com).
Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 178 Rexdale
1-5. EMF Information
Considerations About Welding And The Effects Of Low Frequency Electric And Magnetic Fields
Welding current, as it flows through welding cables, will cause electro­magnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to power­frequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting.
To reduce magnetic fields in the workplace, use the following procedures:
Boulevard, Rexdale, Ontario, Canada M9W 1R3 (phone: 8004636727 or in Toronto 416−747−4044, website: www.csa−in- ternational.org).
Practice For Occupational And Educational Eye And Face Protection,
ANSI Standard Z87.1, from American National Standards Institute, 11 West 42nd Street, New York, NY 10036−8002 (phone: 212−6424900, website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, NFPA Standard 51B, from National Fire Protection Association,
P.O. Box 9101, 1 Battery March Park, Quincy, MA 022699101 (phone: 6177703000, website: www.nfpa.org).
OSHA, Occupational Safety and Health Standards for General Indus­try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and Part 1926, Subpart J, from U.S. Government Printing Office, Super­intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (there are 10 Regional Offices−−phone for Region 5, Chicago, is 3123532220, website: www.osha.gov).
1. Keep cables close together by twisting or taping them.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
4. Keep welding power source and cables as far away from opera­tor as practical.
5. Connect work clamp to workpiece as close to the weld as possi­ble.
About Pacemakers:
Pacemaker wearers consult your doctor before welding or going near welding operations. If cleared by your doctor, then following the above procedures is recommended.
OM-221 677 Page 4
Page 9
SECTION 2 − DEFINITIONS
Warning! Watch Out! There are possible hazards as shown by the symbols.
1 Electric shock can kill.
1.1 Wear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves.
1.2 Protect yourself from electric shock by insulating yourself from work and ground.
1.3 Disconnect input plug or power before working on machine.
2 Breathing welding fumes can be
hazardous to your health.
2.1 Keep your head out of the fumes.
2.2 Use forced ventilation or local exhaust to remove the fumes.
2.3 Use ventilating fan to remove fumes.
3 Welding sparks can cause explosion
or fire.
3.1 Keep flammables away from welding. Do not weld near flammables.
3.2 Welding sparks can cause fires. Have a fire extinguisher nearby, and have a watchperson ready to use it.
3.3 Do not weld on drums or any closed containers.
4 Arc rays can burn eyes and injure
skin.
4.1 Wear hat and safety glasses. Use ear protection and button shirt collar. Use welding helmet with correct shade of filter. Wear complete body protection.
5 Become trained and read the
instructions before working on the machine or welding.
6 Do not remove or paint over (cover)
the label.
Do not discard this product with general waste.
Reuse or recycle Waste Electrical and Electronic Equipment (WEEE) by disposing at a designated collec­tion facility.
Contact your local recycling office or your local distributor for further information.
OM-221 677 Page 5
Page 10
Warning! Watch Out! There are possible hazards as shown by the symbols.
Electric shock from wiring can kill.
Disconnect input plug or power before working on machine.
Read the Owner’s Manual before working on this machine.
1 Consult rating label for input
power requirements, and check power available at the job site they must match.
2 Read Owner’s Manual and
inside labels for connection points and procedures.
3 Move jumper links as shown
on inside label to match voltage at job site.
4 Having a loop of extra length,
connect grounding conductor first.
5 Connect line input conductors
as shown on inside label double-check all connections, jumper link positions, and input voltage before applying power.
1
1 Warning! Watch Out! There
are possible hazards as shown by the symbols.
2 Moving parts, such as fans,
can cut fingers and hands and cause injury. Keep away from moving parts.
2
S-176 106
1
1 Warning! Watch Out! There
are possible hazards as
1
shown by the symbols.
2 Falling unit can cause injury.
Do not move or operate unit where it could tip.
3 Cylinders can expolde if
damaged. Protect compressed gas cylinders from excessive heat, mechanical shock, slag, open flames, sparks, and arcs.
OM-221 677 Page 6
23
Page 11
SECTION 3 − INTRODUCTION
3-1. Included with Your Unit
1
1 Power Source 2 Power Cord (4m) 3 Work Cable and Clamp (4m) 4 Running Gear
3-2. Specifications
Rated Output
at 45% Duty
Cycle
Blu-Fab 3500 350 A 32 V 16-32 38 40018A 11.8 KVA Length: 1040mm
Blu-Fab 4500 450 A 37 V 14-37 47 400-27A 17.7 KVA Length: 1040mm
Welding
Range
Max. OVC Input Rating KVA Dimensions Net Weight
2
4
Height: 760mm
Width: 435mm
Height: 760mm
Width: 435mm
3
146 kg
156 kg
3-3. Duty Cycle Chart
Duty cycle is percentage of 10 minutes that unit can weld at rated load without overheating.
Y Exceeding duty cycle can
damage unit and void warranty.
3-4. Volt-Ampere Curves
Blu-Fab 3500 Blu-Fab 4500
800 700 600 500
400
300
WELDING AMPERES
200
20 25 30 40 50 60 70809010035
% DUTY CYCLE
Blu-Fab 3500: 45% Duty Cycle at 32V, 350A Blu-Fab 4500: 45% Duty Cycle at 37V, 450A
450
350
4.5 Minutes Welding
5.5 Minutes Resting
OM-221 677 Page 7
Page 12
SECTION 4 INSTALLATION
4-1. Selecting a Location
Position unit so air can circulate.
4-2. Typical MIG Connections
1 Power source 2 Work clamp (connect to receptacle as shown) 3 Cylinder (chain to running gear) 4 Cylinder valve Open valve slightly so gas flow blows dirt from valve.
Close valve. 5 Regulator/Flow gauge Install so face is vertical. 6 Flow adjust 7 Gas supply line 8 Wire feeder 9 MIG torch
500 mm
7
500 mm
500 mm
5
6
3
4
9
OM-221 677 Page 8
8
1
2
Page 13
4-3. Electrical Service Guide
24 VOLTS AC
OUTPUT
I
115 volts AC, protected by fuse
Blu-Fab 3500 Blu-Fab 4500
Input Voltage 400 400
Input amperes at rated output 21A 30A Fuse or circuit breaker rating (max. rec) 21A 30A Input conductor size 6 mm Grounding conductor size** 6 mm ** Larger power cord may be required for cable length greater than 3 meters. Consult national or local regulations.
2
2
6 mm
6 mm
4-4. Connecting Input Power
GND/PE
Y Have only qualified persons
make this installation.
Y Special installation may be
required where gasoline or volatile liquids are present consult national or local reg­ulations.
2
2
4-5. Remote 14 Receptacle RC1
Socket Information
OUTPUT
(CONTACTOR)
115 VOLTS AC
GND
OUTPUT
GND/PE
Connect first.
A 24 volts ac. B Contact closure to A completes 24 volts ac contactor control circuit.
I 115 volts AC, protected by fuse.
K G
Chassis common. Circuit common for 24 and 115 volts ac circuits.
.
L1
L3
L2
Tools Needed:
OM-221 677 Page 9
Page 14
4-6. Connecting Welding Gun And Weld Cable
1
2
5
7
3
Euro Torch
US Torch
4
1 Gun Securing Knob 2 Gun Block 3 Gun Outlet Wire Guide Loosen knob, insert gun into block.
Position outlet wire guide as close as possible to drive rolls without touching. Tighten knob.
4 Gun Trigger Plug 5 Gun Trigger Receptacle 6 Weld Cable Terminal
7 Weld Cable From Welding
Power Source
6
4-7. Installing Wire Guide And Drive Roll
Tools Needed:
3/8 in
12
3
Correct Alignment
Incorrect Alignment
1 Inlet Wire Guide 2 Intermediate Wire Guide Install and secure inlet wire guide,
and intermediate wire guide. 3 Drive Roll Install drive rolls and turn drive roll
nut one click. During maintenance intervals,
remove drive rolls, and clean grooves using a wire brush. Check general condition of drive rolls.
Aligning Wire Guide And Drive Rolls:
View is from top of drive rolls looking down with pressure assem­bly open.
Turn screw in or out until drive roll groove lines up with wire guide.
Close pressure roll assembly. Repeat for remaining drive rolls un-
til all drive rolls line up with wire guides as shown.
802 310-A
OM-221 677 Page 10
Page 15
5-1. Controls
SECTION 5 OPERATION
1 Power Switch The power switch is a selector knob
which permits selection of operation on either of the two available ranges (I and II) and the center position is off.
2 Indicator Lamp This lights up when the power switch
is placed in the ON position. 3 Protection Fuse Fuse F protects the control circuit.
Should it become necesary to re­place any fuse in the welding power source, be sure to substitute with one of the same size and rating.
4 Use this control to adjust weld
voltage 10 position switch. 20 weld setting, 10 high range (I), 10 low range (II).
5 High Temperature Shutdown
Light
This lights up when unit overheats and shuts down.
6 Voltage/Amperage Meter. Use toggle switch to select voltage or
amperage. 7 Low Inductance Negative
Output Terminal
Connect work lead here for most “short-arc” applications.
8 High Inductance Negative
Terminal
Connect work lead here for stainless steel and spray arc conditions.
9 115 AC Receptacle (optional) Located on the rear panel is a recep-
tacle which provides power to the gas heater, when welding with CO shielding gas and for the cooling sys­tem.
10 Wire Feeder Power Cable
Receptacle
Located on the rear panel is a recep­tacle used to supply operating power to the wire feed unit.
11 Positive Out Terminal
4
7 8
51 32
6
Front Panel
11109
2
115 VAC
Back Panel
OM-221 677 Page 11
Page 16
5-2. Panel Controls
1 2 3 4 5
1 Voltage Control 2 Purge Control 3 Jog 42T−4T Switch 5 Power ON-OFF 6 Torch Connection 7 Circuit Breaker
7
8
9
8 Gas In Connector 9 Control Cable Connection 10 Weld Cable Connection
6
10
5-3. Run-In Control and Burnback Control
4
2
6
10
Run-In Control
Use control to set wire feed speed before arc initiation
After arc initiation, wire feed speed is controlled by the wire feed speed
8
control on the front control panel.
Burnback Control
Control adjusts the time welding wire is energized after wire feed stops.
OM-221 677 Page 12
4
2
6
8
10
t
Page 17
SECTION 6 − MAINTENANCE AND TROUBLESHOOTING
6-1. Routine Maintenance
Y Disconnect power before maintaining.
. Maintain more often during severe conditions.
3 Months
Replace unreadable labels. Clean and tighten weld terminals.
Repair or replace cracked weld cable.
Replace o-ring in Electrode/Gas Output receptacle if cracked.
6 Months
Blow out or vacuum inside.
6-2. Troubleshooting
Trouble Remedy
No weld output; fan does not run.
Place line disconnect switch in On position (see Section 4-4).
Repair or replace cracked gas hose.
OR
No weld output; fan on.
Fan not operating; weld output available.
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 4-4).
Check for proper input power connections (see Section 4-4).
Check and replace if necessary.
Tighten wire feeder connection to Remote 14 receptacle.
Unit overheated. Allow unit to cool (see Section 3-3).
Check for and remove anything blocking fan movement.
Have Factory Authorized Service Agent check fan motor.
OM-221 677 Page 13
Page 18
Notes
OM-221 677 Page 14
Page 19
SECTION 7 - ELECTRICAL DIAGRAM
12
12
26
24 Vac
24
4
6
3
5
DIGITAL A-V
RC1
+
31
Z
28 30
Vc
SR1
29
25
SHUNT
B
MT
B
PRI.
XXX
XXX
S2R1 T3
XXX
X
X
XXX
12345678 9101112
X 123456789
B
XXX
XXX
B
XXX
X
XX
XXX
10
POSIZIONI
SEC.
B
B
212121
1234 567 8 9101112
S2
S3
RL 1
TL 3
SL 2
RL 1
W
RRR
TL 3
SL 2
7198
6
2
W
1
3
AT
115V24V
20
OPTIONAL
PL
OL
RC2
CR
CR
R
23
14
13
CR
RC1
w
BG AKI
22 20 21 115
400V
4
S3
W
11
F
5
230V
10
9
RC3
FM
GND
IN RECT.TP
C1 C2 C3
RST
956142300_91004
OM-221 677 Page 15
Page 20
8-1. Main Assembly
1
2
SECTION 8 - PARTS LIST
36
10
26
27
35
43
46
25
24
23
22
47
*
*
18
21
3
4
5
6
4
7
9
10
41
*
31
30
28
29
19
42
11
33
40
32
20
34
44
45
39
14
12
OM-221 677 Page 16
13
15
37
16
17
48
38
9/13/04
Page 21
Item
No.
Dia.
Mkgs.
Part
No.
Description
BF3500 BF4500
8-1. Main Assembly
1 116121119 Wrapper, Top cover 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 156002044 Handle Assy 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 056072075 Power On Indicator light assy 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 056072076 Knob Pointer 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 000046432 Fuse Holder Assy 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 056092039 Fuse, Aux Circuits 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 056072076 Over Temp Indicator light assy 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 116118150 Front Panel 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 056076152 Dinze Output socket 3 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 056076169 Dinze Output socket 3 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11 056067169 *Switch Volt/Ammeter (opt) 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 116005081 Mounting Bracket, Rectifier Assy 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13 056159008 Thermal Cutout switch PCT 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 056050058 Rectifier, Main welding 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 056050017 Rectifier, Main welding 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 056059257 Shunt 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 056059262 Shunt 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 028021447 Main Transformer 400V 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 028021448 Main Transformer 400V 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 027015542 Coil, Primary/Secondary 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 027015541 Coil, Primary/Secondary 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 156031040 Mounting Bracket, Contactor 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19 028038040 Stabilizer Assy 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19 028038041 Stabilizer Assy 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20 156006030 Base 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21 057079032 Contactor 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21 057079033 Contactor 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22 057014030 Primary Cord 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
057024004 Capcitor C1,C2 & C3 Filter 3 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
056059189 Resistor R1,R2 & R3 Filter 3 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23 356078032 Fan Blade 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24 116118151 Rear Panel 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25 000173283 Fan Cowling 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26 056076170 Receptacle, 14 Pin Female 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27 116122277 Wrapper, Left side 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27 116122278 Wrapper, Right side 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28 000124274 Bracket, Mounting, Fan Motor 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29 056126072 Fan Motor 230VAC 50/60Hz 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30 056067196 Switch, 10 position 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30 056067205 Switch, 10 position 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31 056067203 Switch, 3 Position 1
31 067067204 Switch, 3 Position 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32 157095014 PCB, Digital Volt/Ammeter 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
33 058021042 Transformer, Auxiliary 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34 056091041 Clamp, Cable strain relief 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
35 116122280 *Front base plate cover 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
36 000006393 Relay 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37 Bracket, XFM mounting 4 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
38 156085088 “A” Frame upright bracket 2 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39 157029012 “A” Frame cross member 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40 316029695 Name plate, Lexan 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40 316029697 Name plate, Lexan 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
41 056054065 *Castor, Front, swivel 2 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
42 116085123 *Bracket, mounting, front castor 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
43 056054064 *Wheel, Rear 2 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
44 057029005 *Axle assy, Rear 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
45 156009067 *Washer, Plain 2 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
46 156087017 *Pin, Split type 2 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
47 117029005 *Bottle Rack Assy, rear 1 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
48 156085087 “A” Frame Upright 2 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
* Optional, certain markets
OM-221 677 Page 17
Page 22
. Hardware is common and
not available unless listed
OM-221 677 Page 18
April 19, 2006
Figure 8-2. Wire Feed Assembly
Page 23
Item
No.
Dia.
Mkgs.
Part No.
Description
Figure 8-2. Wire Feed Assembly
1 000058427 Ring 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 156032128 Spring 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 156018033 Nut 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 156009079 Washer 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 156032064 Spring 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 156009075 Washer, flat 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 000186435 Hub 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 000186436 Washer, plastic 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 156005108 Support spool 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11 056076216 Dinze Socket 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 056076192 Receptacle, 14 pin male 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13 056061042 Gas Solenoid Valve 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 000083432 CB1 Circuit Breaker 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 116118168 Rear Panel, steel 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 117060014 Plate, centre 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 000151187 Latch 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 116122319 Side Panel, steel 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19 156034004 Hinge, Polycarbonate 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20 000208015 Handle 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21 156121022 Cover, steel 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22 000204326 Compartment, accessories 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23 057084110 Circuit Card, control board 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24 056093022 Switch, gas purge 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25 056093022 Switch, wire jog 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26 056067169 Switch, 2T 4T trigger latch 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27 056067194 Switch, power on/off 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28 316029696 Nameplate, upper polycarbonate 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29 000207076 Knob, pointer 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30 *756005024 Flange, euro adapter 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31 316029694 Nameplate, lower polycarbonate 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32 116118167 Front Panel, steel 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
33 056059182 Potentiometer, wire speed control 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34 156005097 Motor Support, steel 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
35 056059277 Potentiometer, 10.Kohm 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
36 +178937A Label, electric shock and pinch 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37 +116006130 Base, steel 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
38 *057052032 Euro torch adapter 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39 Fig 8-3 Wire Drive Assembly 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40 Optional US torch plug connection 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
41 +S178936 Label, general precautionary 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
42 656110012 Foot, rubber 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
43 027112275 Weld cable, w/lugs 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
44 Grommet, blanking plug 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
45 057028075 PCB Run-In Control and Harness. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
46 956142486 Label, Run-In and Burnback. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Qty
* Optional, certain markets
OM-221 677 Page 19
Page 24
. Hardware is common and
not available unless listed
20
19
18
17
Item
No.
12
13
11
4
Dia.
Mkgs.
14
15
16
Part No.
6
7
8
9
10
Figure 8-3. Wire Drive Assembly (All Models)
Description
Figure 8-3. Wire Drive Assembly (All Models)
1
2
3
4
5
9/13/04
Qty
1 057010052 Drive Motor, 24 VDC, 60w 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 187 325 Insulator, drive assembly 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Bolt, Power stud 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 602 213 Washer, locking 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 656005029 Insulator, drive assembly 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 206219 Housing, adapter gun/feeder 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 124778 Knob, T Bar 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 604 673 Screw, hex c/sunk. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 173 618 Drive Gear, central 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 602 239 Washer, central drive gear/shaft 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11 174 609 Screw, central drive gear/shaft 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 602 009 Screw, soc head hex 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13 601 872 Nut, power stud 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 602 213 Washer, plain, power stud 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15 010 224 Pin, tension arm 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 166971 Lever, mtg pressure gear 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 089562 Fastener, pinned 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 196896 Cup, tension arm 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19 196897 Spring, tension 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20 196895 Knob, adjustment tension 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-221 677 Page 20
Page 25
Notes
Page 26
Notes
Page 27
Effective January 1, 2006
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
LIMITED WARRANTY Subject to the terms and conditions below, ITW Welding Products Italy S.r.l., warrants to its original retail purchaser that new Miller equipment sold after the effective date of this limited warranty is free of defects in material and workmanship at the time it is shipped by Miller. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
Within the warranty periods listed below, Miller will repair or replace any warranted parts or components that fail due to such defects in material or workmanship. Miller must be notified in writing within thirty (30) days of such defect or failure, at which time Miller will provide instructions on the warranty claim procedures to be followed.
Miller shall honor warranty claims on warranted equipment listed below in the event of such a failure within the warranty time periods. All warranty time periods start on the date that the equipment was delivered to the original retail purchaser, or one year after the equipment is sent to a European distributor or eighteen months after the equipment is sent to an International distributor.
1. 5 Years Parts 3 Years Labor * Original main power rectifiers * Inverters (input and output rectifiers only)
2. 3 Years — Parts and Labor * Transformer/Rectifier Power Sources * Plasma Arc Cutting Power Sources * Semi-Automatic and Automatic Wire Feeders * Inverter Power Sources (unless otherwise stated) * Water Coolant Systems (integrated) * Intellitig * Maxstar 150 * Engine Driven Welding Generators
(NOTE: Engines are warranted separately by the engine manufacturer.)
3. 2 year − Parts and Labor (Panther only) * Hydramate 1&2 Water Cooling Unit
4. 1 year − Parts and Labor unless specified * DC 253 & 403 Rectifier (April 06>) * Migmatic 171 (April 06>) * Motor Driven Guns (w/exception of Spoolguns) * Process Controllers * Positioners and Controllers * Automatic Motion Devices * RFCS Foot Controls * IHPS Power Sources and Coolers * Water Coolant Systems (nonintegrated) * Flowgauge and Flowmeter Regulators (No Labor) * HF Units * Grids * Spot Welders * Load Banks * Arc Stud power sources and Arc Stud guns * Running Gear/Trailers * Plasma Cutting Torches (except APT & SAF
Models)
* Field Options
(NOTE: Field options are covered under True Blue® for the remaining warranty period of the product they are installed in, or for a minimum of one year — whichever is greater.)
5 6 Months — Batteries
6. 90 Days — Parts * MIG Guns/TIG Torches * Induction heating coils and blankets
* APT Model Plasma Cutting Torches * Remote Controls * Accessory Kits * Replacement Parts (No labor) * Spoolmate Spoolguns * Canvas covers
Miller’s True Blue® Limited Warranty shall not apply to:
1. Consumable components; such as contact tips, cutting nozzles, contactors, brushes, slip rings, relays or parts that fail due to normal wear.
2. Items furnished by Miller, but manufactured by others, such as engines or trade accessories. These items are covered by the manufacturer’s warranty, if any.
3. Equipment that has been modified by any party other than Miller, or equipment that has been improperly installed, improperly operated or misused based upon industry standards, or equipment which has not had reasonable and necessary maintenance, or equipment which has been used for operation outside of the specifications for the equipment.
MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS TRAINED AND EXPERIENCED IN THE USE AND MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the exclusive remedies shall be, at Miller’s option: (1) repair; or (2) replacement; or, where authorized in writing by Miller in appropriate cases, (3) the reasonable cost of repair or replacement at an authorized Miller service station; or (4) payment of or credit for the purchase price (less reasonable depreciation based upon actual use) upon return of the goods at customer’s risk and expense. Miller’s option of repair or replacement will be F.O.B., Factory at ITW Welding Products Group Europe, or F.O.B. at a Miller authorized service facility as determined by Miller. Therefore no compensation or reimbursement for transportation costs of any kind will be allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE REMEDIES. IN NO EVENT SHALL Miller BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY OTHER LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY IMPLIED WARRANTY, GUARANTY OR REPRESENTATION AS TO PERFORMANCE, AND ANY REMEDY FOR BREACH OF CONTRACT TORT OR ANY OTHER LEGAL THEORY WHICH, BUT FOR THIS PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED BY MILLER.
Some states in the U.S.A. do not allow limitations of how long an implied warranty lasts, or the exclusion of incidental, indirect, special or consequential damages, so the above limitation or exclusion may not apply to you. This warranty provides specific legal rights, and other rights may be available, but may vary from state to state.
In Canada, legislation in some provinces provides for certain additional warranties or remedies other than as stated herein, and to the extent that they may not be waived, the limitations and exclusions set out above may not apply. This Limited Warranty provides specific legal rights, and other rights may be available, but may vary from province to province.
milan_warr 1/06
Page 28
Owner’s Record
Please complete and retain with your personal records.
Model Name Serial/Style Number
Purchase Date (Date which equipment was delivered to original customer.)
Distributor
Address
Country Zip/Postal Code
For Service
Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Contact the Delivering Carrier to:
Welding Supplies and Consumables Options and Accessories Service and Repair Replacement Parts Owner’s Manuals
File a claim for loss or damage during shipment.
For assistance in filing or settling claims, contact your distributor and/or equipment manufacturer’s Transportation Department.
ITW Welding Products Italy S.r.l.
Via Privata Iseo, 6/E 20098 San Giuliano Milanese, Italy Phone: 39 (0) 2982901 Fax: 39 (0) 298290-203 email: miller@itwwelding.it
PRINTED IN USA © 2006 Miller Electric Mfg. Co. 1/06
Loading...