Mighty Mule MM571W, MM572W Installation Manual

MM571W MM572W
Installation Manual
(For a single or dual gate installation)
Single gate installation [MM571W]
Post Bracket
Gate Swings Evenly and Freely Hung Firmly and Plumb
Secondary Opener
Power Cable
Fence Post Set in Concrete Fence Post Set in Concrete
Warning Sign
Gate Bracket
PVC conduit (not included) to run second opener power cable under driveway.
Warning Sign
Gate Bracket
Dual gate installation MM572W]
Example of Dual Gate nished installation
(Installations vary slightly on different types of gates)
Post Bracket
Primary Gate Opener
PVC conduit (not included) to protect wire from lawn mowers and weed eaters.
Control Box
120 Volt indoor Transformer
(surge protector
not supplied)
Run 1000' (max.) of low voltage wire to control box from transformer (wire not included).
This product meets the requirements of UL325, the standard for gate operator safety.
Mighty Mule® is the retail brand of Nortek Security and Control, LLC.
Copyright© 2019 Nortek Security and Control, LLC. 10022116 A
WARNING
This equipment meets Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions. Failure to follow installation and safety instructions can result in hazards developing due to improper assembly. You agree to properly install this product and that if you fail to do so Nortek Security and Control, LLC, shall in
no event be liable for direct, indirect, incidental, special or consequential damages or loss of prots
whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter. The installer and/or user agree to assume responsibility for all liability and use of this product releasing Nortek Security and Control, LLC, from any and all liability. If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value.
READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to install and use this automatic gate operator. This gate operator produces a high level of force. Stay clear of the unit while it is operating and exercise caution at all times.
ALL AUTOMATIC GATE OPERATORS ARE INTENDED FOR USE ON VEHICULAR GATES ONLY.
Product Usage
The Mighty Mule Gate Operator meets all of the safety requirements of a Class I Residential Vehicular Gate Operator and is intended for use solely with vehicular swing gates in single-family residential applications that meet the Class I category listed in the table below.
Vehicular Gate Operator Class Categories
Residential Vehicular Gate Operator-Class I:
A vehicular gate operator (or system) intended for use in garages or parking areas associated with a residence of one-to-four single families.
Commercial/General Access Vehicular Gate Operator-Class II:
A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (ve or more single family units), hotel, garages, retail store, or other buildings accessible by or servicing the general public.
Industrial/Limited Access Vehicular Gate Operator–Class III:
A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other
locations not accessible by or intended to service the general public.
Restricted Access Vehicular Gate Operator – Class IV:
A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not accessible by or intended to service the general public.
Table of Contents
Please Read This First! .......................................................................................................................... ii
Important Safety Information ................................................................................................................ iii
Manually Opening and Closing Gate ................................................................................................................................................ iii
For the Installer and End User .......................................................................................................................................................... iv
Installing Warning Signs and Pedestrian Gates ...............................................................................................................................viii
Required Safety Precautions for Gates ............................................................................................................................................. ix
Technical Specications ........................................................................................................................ x
Mighty Mule 571W/572W Gate Opener ............................................................................................................................................. x
Powering Options ............................................................................................................................................................................ xi
Solar Panel and Gate Activity Chart .................................................................................................................................................. xi
Before You Begin ................................................................................................................................... xi
Check Existing Gate Size and Material ............................................................................................................................................ xii
IMPORTANT: Check for Proper Gate Installation ............................................................................................................................... xii
Items Included for Primary Gate Opener Installation (MM571W) ......................................................................................................xiii
Items Included for Secondary Opener Installation (MM572W) .........................................................................................................xiii
Tools Needed .................................................................................................................................................................................xiv
Items Not Included .........................................................................................................................................................................xiv
Check Direction of Gate Swing .......................................................................................................................................................xiv
Mechanical Installation .......................................................................................................................... 1
Assessing the Gate for Installation ................................................................................................................................................... 1
Pull-to-Open Operator Mounting (Most Common
Installing the Closed Position Stop Plate / Pull-to-Open ..................................................................................................................... 7
Push-to-Open Operator Mounting ..................................................................................................................................................... 8
Installing the Closed Position Stop Plate / Push-to-Open ................................................................................................................. 13
Control Box Installation ...................................................................................................................................................................14
Connecting the Operator(s) and battery ......................................................................................................................................... 16
Connecting the Operator(s) and battery ......................................................................................................................................... 17
Transformer or Solar panel wiring Installation ................................................................................................................................. 18
Transformer or Solar panel wiring Installation ................................................................................................................................. 19
) .............................................................................................................................2
Electrical Installation and Setup .......................................................................................................... 21
Dip Switches settings ..................................................................................................................................................................... 21
Transmitter Programming ............................................................................................................................................................... 22
Operator Limit Setting .................................................................................................................................................................... 23
Auto Close Setting .......................................................................................................................................................................... 24
Optional Smart Control Setup .............................................................................................................. 24
Connecting Additional Devices ........................................................................................................... 25
Control Board Connections ............................................................................................................................................................. 26
Connecting Accessories .................................................................................................................................................................27
Maintenance ......................................................................................................................................... 28
Troubleshooting Guide - Audible Feedback ....................................................................................... 29
Troubleshooting Guide - Visual Feedback .......................................................................................... 31
For Your Records .................................................................................................................................. 33
Repair Service ...................................................................................................................................... 34
Accessories .......................................................................................................................................... 35
Appendix A ........................................................................................................................................ 37
Accessory Installation Instructions ..................................................................................................................................................37
Gate Operator Installation Checklist ................................................................................................... 38
Please Read This First!
Thank you for purchasing a Mighty Mule Gate Operator— Nortek Security and Control's "do-it-yourself" automatic gate operator! When correctly installed and properly used, your Mighty Mule Gate Operator will give you many years of reliable service. Please read the following information to ensure you have the correct system for your particular needs. If so, this manual and will enable you to properly install your Mighty Mule Gate Operator.
The Mighty Mule Gate Operator is designed for installation for single or dual gates. The gate(s) must not exceed 18 feet in length or weigh more than 850 pounds (please see Technical Specications on page x). The Mighty Mule Gate Operator can be used on vinyl, aluminum, chain link, farm tube, and wrought iron gates.
Not rated for use on solid surface gates due to the
potential to damage the operator and/or injure someone.
The Mighty Mule Gate Operator accommodates extra transmitters, digital keypads, solar panels, push buttons, automatic gate locks, and other access control products. These optional accessories (see the Mighty Mule Accessory Catalog) are available at most stores. Your store should be able to special order any accessory not in stock.
The Mighty Mule Gate Operator also has an adjustable auto-close feature. After the gate reaches the fully open position, it can be set to remain open up to 120 seconds before automatically closing. Pressing the transmitter button at any time after the gate opens fully will cause it to close immediately. OFF is the factory setting; meaning the gate will stay open until you press the transmitter (or keypad, etc.) again.
NOTE—If your application requires any of the following:
Swing gates longer than 18 feet or weighing more than 850 pounds
Slide gates
Heavy duty or commercial uses
Professional installation
Go to www.linearproaccess.com for a dealer or retailer near you or call (800) 543-4283 for information about our Linear professional line of gate operators and accessories. Our Sales Department will be glad to give you the name and phone number of a Linear dealer near you.
If your store cannot special order accessories, please call the Mighty Mule Sales Department (800-543-4283).
The Mighty Mule Gate Operator features Dual Sense Technology™. This feature makes the gate stop and reverse direction when it comes in contact with an obstruction.
BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPERATOR:
Read these instructions carefully to become familiar with all parts and installation steps.
The video is only designed as an overview of the installation procedure.
You must read the installation manual for detailed instructions
on gate operator safety and proper use of the gate operator.
NOT FOR THE CONTAINMENT OF ANIMALS.
ii MM571W / MM572W Installation Instructions
Important Safety Information
Because automatic gate operators produce high levels of force, consumers need to know the potential hazards associated with improperly designed, installed, and maintained automated gate operator systems. Keep in
mind that the gate operator is just one component of the total gate operating system. Each component must
work in unison to provide the end user with convenience, security, and safety.
This manual contains various safety precautions and warnings for the installer and end user. Because there are many possible applications of the gate operator, the safety precautions and warnings contained in this manual cannot
Because Mighty Mule automatic gate operators are only part of the total gate operating system, it is the responsibility of the installer and end user to ensure that the total system is safe for its intended use.
be completely exhaustive in nature. It does, however, provide an overview of the safe design, installation, and use of this product. CAREFULLY READ AND FOLLOW ALL
SAFETY PRECAUTIONS, WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE SYSTEM DESIGN, INSTALLATION, AND USE OF THIS PRODUCT.
Warnings in this manual are identied with this warning symbol. The symbol identies conditions that can result in damage to the operator or its components, serious injury, or death.
MANUALLY OPENING AND CLOSING GATE
CAUTION
The gate will move freely and uncontrolled when the gate operator is removed from the gate.
ONLY disconnect the operator when the control box power switch is OFF and the gate is NOT moving.
Disconnecting the Operator
1. Turn control box power switch OFF.
2. Remove the hairpin clip and clevis pin.
3. Remove the operator’s front mount from the gate bracket.
The gate can be opened and closed manually when the operator is disconnected.
NOTE: Substitute a Pin Lock for the clevis pin on the front mount of the gate operator to prevent theft of the operator from the gate (see accessory pages in back of this book).
Front Mount
Clevis Pin
Gate Bracket
Hairpin Clip
Part #: FM133
MM571W / MM572W Installation Instructions iii
Important Safety Information
FOR THE INSTALLER AND END USER
WARNING
To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Never let children operate or play with gate controls. Keep the remote control
away from children.
3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death.
5. Use the manual/emergency release only when the gate is not moving.
6. KEEP GATES PROPERLY MAINTAINED. Read the user’s manual. Have
a qualied service person make repairs to gate hardware.
7. The entrance is for vehicles only. Pedestrians must use separate entrance.
8. The gate must be installed in a location that provides adequate clearance between it and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates must not open into public access areas.
9. SAVE THESE INSTRUCTIONS.
I. Before Installation
1. Verify this operator is proper for the type and size of gate, frequency of use
and class of the gate system.
2. Make sure the gate has been properly installed and swings freely in both directions. Repair or replace all worn or damaged gate hardware prior to installation. A freely moving gate will require less force to operate and will enhance the performance of the entrapment protection devices used with the system (see page xii).
3. Review the operation of the system to become familiar with its safety features. Understand how to disconnect the operator for manual gate operation (see page iii).
4. The gate and operator installation must comply with any applicable local codes.
5. This gate operator is intended for vehicular gates only. A separate entrance or gate must be installed for pedestrian use (see page viii).
6. Always keep people and objects away from the gate and its area of travel. No one should cross the path of a moving gate.
7. Identify all of the entrapment zones for the type of installation. An entrapment zone is an area around the automatic gate system where a person or object could be caught that increase the risk of injury. Entrapment zones should be eliminated, guarded or protected.
ZONE 2
8. When designing a system that will be entered from a highway or main thoroughfare, make sure the gate system is placed far enough from the road to prevent trafc congestion.
ZONE 1
Entrapment Zones for a Pull-To-Open Application
ZONE 1
ZONE 3
Driveway
MM571W
ZONE 2
ZONE 5
ZONE 4
Gate in the Open Position
ZONE 2
iv MM571W / MM572W Installation Instructions
ZONE 5
ZONE 4
Gate in the Open Position
ZONE 3
Driveway
Entrapment Zones for a Pull-To-Open Application
MM572W
ZONE 3
ZONE 5
ZONE 4
Gate in the Open Position
Important Safety Information
FOR THE INSTALLER AND END USER
Typical Entrapment Zones are shown in the diagrams on page iv:
Zone 1 – leading edge of the gate and the fence post.
Zone 2 – between the gate and the gate post.
Zone 3 – the path of the gate.
Zone 4 – the space between the gate in the open position and any object such as a wall, fence, tree, etc.
Zone 5 – pinch points between the operator and gate.
II. During Installation
1. Install the gate operator on the inside of the property and
fence line. DO NOT install an operator on the outside of the gate where the public has access to it.
2. Be careful with moving parts and avoid close proximity to areas where ngers or hands could be pinched.
3. Devices such as contact sensors (sensing edges) and non contact sensors (photo beams) provide
additional protection against vehicular damage.
4. If push buttons or key switches are installed, they should be within sight of the gate, located at least 10 feet from any moving part of the gate (see diagram below).
Never install any control device where a user will be tempted to reach through the gate to activate the gate operator.
5. Secure outdoor or easily accessed gate operator controls in order to prohibit unauthorized use of the gate.
NEVER install any control device
within the indicated area
MM571W
10'
Moving Gate
Area
Driveway
Pull-To-Open Application
10'
10'
10'
MM572W
Pull-To-Open Application
Moving Gate
Area
Driveway
NEVER INSTALL
any control device
within the indicated area
Pull-To-Open Application
Moving Gate
Area
MM571W / MM572W Installation Instructions v
10'10'
10'10'
10'10'
Important Safety Information
FOR THE INSTALLER AND END USER
III. After Installation
1. Attach the warning signs (included) to each side of the
gate to alert the public of automatic gate operation. It is your responsibility to post warning signs on both sides of your gate. If any of these signs or warning decals becomes damaged, illegible, or missing, replace them immediately. Contact Nortek Security and Control for free replacements.
2. The gate is automatic and could move at any time, posing serious risk of entrapment. No one should be in contact with the gate when it is moving or stationary.
3. Do not attempt to drive into the gate area while the gate is moving; wait until the gate comes to a complete stop.
4. Do not attempt to “beat the gate” while the gate is closing. This is extremely dangerous.
5. Do not allow children or pets near your gate. Never let children operate or play with gate controls. Keep the remote control away from children and unauthorized users; store controls where children and unauthorized users do not have access to them.
11. IMPORTANT: Save these safety instructions. Make sure
everyone who is using or will be around the gate and gate operator are aware of the dangers associated with automated gate systems. In the event you sell the property with the gate operator or sell the gate operator, provide a copy of these safety instructions to the new owner.
Should you need a replacement manual, a copy can be obtained by downloading one from the Mighty Mule web site (www.mightymule.com), by contacting Nortek Security and Control by calling 1-800-543-4283 and requesting a duplicate copy.
6. KEEP GATE SYSTEMS MAINTAINED. Always turn power to operator OFF before performing any maintenance. See
page 28 for maintenance procedures.
7. To operate this equipment safely, YOU must know how to disconnect the operator for manual gate operation (see
page iii). If you have read the instructions and still do not
understand how to disconnect the operator, contact the Mighty Mule Service Department.
8. Disconnect the operator ONLY when the power is TURNED OFF and the gate is NOT moving.
9. Make arrangements with local re and law enforcement for emergency access.
10. Distribute and discuss copies of the IMPORTANT SAFETY INFORMATION section of this manual with all persons authorized to use your gate.
vi MM571W / MM572W Installation Instructions
(recommended, not included)
Leading Edges
Important Safety Information
FOR THE INSTALLER AND END USER
Mighty Mule gate operators utilize Dual Sense Technology entrapment protection. Dual Sense Technology
is built
into every Mighty Mule and provides redundant methods of entrapment protection for open and close gate directions.
In addition to Dual Sense Technology, every Mighty Mule gate controller has provisions for the connection of additional obstruction detection devices such as sensing edges and photo beams.
These devices may be located where there is an increased risk of obstruction. Refer to the diagram below.
Control Box
NOTE: Photo beams should always be located on the non-travel side of the gate.
Photo Beam
(recommended, not included)
Example of MM571W Installation
(Installations vary slightly on different types of gates)
One or more edge sensors may be located at the leading edge, bottom edge, and post edge, both inside and outside of a vehicular swing gate system.
Wiring to sensors must be located and arranged so the wiring between the sensor and the gate operator is not subjected to mechanical damage.
A wireless sensor such as one that transmits radio frequency (RF) signals that promote safety shall be located where the transmission of the signals is not obstructed or impeded by building structures, natural landscaping or similar objects.
Leading Edge
Gate Warning Sign
Vehicular Gate
Sensing Edges
(recommended, not included)
of the gate
Photo Beam
(recommended, not included)
Photo Beam
Gate Warning Sign
Sensing Edges
(recommended, not included)
of gates
Gate Warning Sign
Vehicular GateVehicular Gate
Sensing Edges
(recommended, not included)
Control Box
Photo Beam
(recommended, not included)
Example of MM572W Installation
(Installations vary slightly on different types of gates)
Entrapment and Obstruction Protection
Mighty Mules’s Dual Sense Technology provides entrapment protection. Since all installations are different, you may need to add photo beams or sensing edges to help prevent damage to vehicle or other items that could be hit by a moving gate.
Entrapment Alarm
The Mighty Mule Automatic Gate Operator is designed to stop and reverse the gate when the gate comes in contact with an obstruction. Additionally, these operators are equipped with an audio entrapment alarm which will activate if the unit obstructs twice while opening or closing. This alarm will sound for a period of 5 minutes, or until the operator receives an intended signal from a hard wired entry/exit source (e.g. push button control or keypad). Turning the power switch on the control box OFF and back ON will also deactivate the alarm. Wireless controls such as transmitters and wireless keypads will not deactivate the alarm.
MM571W / MM572W Installation Instructions vii
Important Safety Information
INSTALLING WARNING SIGNS AND PEDESTRIAN GATES
Warning signs alert people of automatic gate operation and are required when installing Mighty Mule Automatic Gate Operators. A minimum of two WARNING SIGNS must be installed in the area of the gate. Each sign is to be visible by persons located on the side of the gate on which the placard is installed.
The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.
We recommend using the Bulldog Pedestrian Gate Lock (Call the Nortek Security and Control Sales Department at 800-543-
4283) for controlled access.
Pedestrian Gate Lock
(recommended, not included)
Control Box
Bulldog Pedestrian
Gate Lock
(recommended, not included)
Warning Sign
7 foot
minimum
Vehicular Gate
Example of MM571W Installation
(Installations vary slightly on different types of gates)
7 foot
minimum
Warning SignPedestrian Gate Warning Sign Control Box
Vehicular Gate Vehicular Gate
Pedestrian Gate
Example of MM572W Installation
(Installations vary slightly on different types of gates)
Warning Signs
The gate operator is provided with two safety warning signs (four signs for dual operator installation). The signs MUST be installed on the front and back of the gate where they will be visible in the area of the gate.
Permanently secure each warning sign to the gate.
Immediately replace a damaged, eligible or missing warning sign.
Call Customer Service at 800-543-4283 for a free replacement.
viii MM571W / MM572W Installation Instructions
!
Important Safety Information
REQUIRED SAFETY PRECAUTIONS FOR GATES
These warning labels should be found at the locations specied below. If any of them are missing, immediately contact Nortek Security and Control for replacements.
WARNING
AVERTISSEMENT
Moving gate can cause injury or death!
1. KEEP CLEAR! Gate may move at any time.
2. Read all SAFETY INSTRUCTIONS in the user’s manual.
3. Do not allow children to operate gate or play in gate area.
4. This gate is for vehicles only. Pedestrians must use separate entrance.
La barrière en mouvement peut provoquer des blessures graves ou la mort!
1. TENEZ-VOUS LOIN! La barrière peut se déplacer à tout moment.
2. Lisez toutes les instructions de sécurité dans le manuel de l'utilisateur.
3. Ne laissez pas les enfants utiliser la barrière ou jouer à proximité de la barrière.
4. Cette barrière est uniquement réservée aux véhicules. Les piétons doivent utiliser une autre entrée.
10019674A
Labels (1) installed on the front of control box
MM571W / MM572W Installation Instructions ix
Technical Specifications
MIGHTY MULE 571W/572W GATE OPENER
Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-20 ºC to +71 ºC).
Opener length with push-pull tube fully retracted is 40.25", mounting point to mounting point. Maximum stroke is 20".
Maximum opening arc of 110º. Approximate opening time (90º): 14 seconds, depending on weight of gate.
The system is powered by a 12 Vdc battery (included). Optional automotive or marine battery may be used (not included).
Battery charge is maintained by Mighty Mule transformer or optional Mighty Mule Solar Panels.
The system uses 25 A Mini ATC blade-style fuses.
NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with higher ampere rated
fuses; doing so will void your warranty and may damage your control board.
Adjustable auto-close timer (OFF, 3 to 120 seconds), and Dual Sense Technology Entrapment Protection.
Accessory terminal block fully compatible with all Mighty Mule access controls.
Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.
OPERATIONAL CAPACITY
Maximum Weight (lbs.) Maximum Length (ft.)
850 8
750 10
650 12
550 14
450 16
350 18
NOTE: Ball bearing hinges should be used on all gates weighing over 250 lb.
The Gate Capacity Chart below shows the recommended maximum gate length to weight. The minimum recommended gate length is 5 ft.
x MM571W / MM572W Installation Instructions
Before You Begin
POWERING OPTIONS
1. Determine Charging Option for Battery: Transformer OR Solar
NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT
THE SAME TIME. It will damage the control board.
IMPORTANT:
The transformer is designed for indoor use. If the transformer can be plugged only into an outside electrical outlet, a weatherproof cover/housing (available at local electrical supply stores) must be used.
If your gate is more than 1000 ft. from an AC power source, you will need to use at least 10 watt solar charging power to charge the battery [FM123]. Refer to the Solar Panel and Gate Activity chart below.
All low voltage wire used with the Mighty Mule gate operator must be 16 gauge dual conductor, stranded, direct burial wire [RB509]. Do not run more than 1000 ft. of wire.
* If the gate operator controller is OFF, the system will NOT charge the battery.
SOLAR PANEL AND GATE ACTIVITY CHART
The table and map illustrate the maximum number of gate cycles to expect per day in a particular area when using from 10 to 30 watts of solar
charging power prior to the battery depleting to a state where the unit will not function. The gures shown are for winter (minimum sunlight). Accessories connected to your system will draw additional power from the battery.
Deep cycle marine battery is recommended for solar and/or high trafc applications.
Single Gate Winter Ratings Zone 1 Zone 2 Zone 3
12 v single gate (10 watts) solar charger 8 16 26
12 v single gate (20 watts) solar charger 14 28 38
12 v single gate (30 watts) solar charger 20 44 54
* Power increments are for reference only.
MM571W / MM572W Installation Instructions xi
Metal gate post
Gate Opener Control Box
CHECK EXISTING GATE SIZE AND MATERIAL
A - Level B C D
Concrete
• Gate size: Up to 18 feet and up to 850 lbs. — See Operational Capacity chart on page x.
Not rated for use on solid surface gates.
• Type of gate material: Vinyl, aluminum, chain link, farm tube, wrought iron, wood.
IMPORTANT: CHECK FOR PROPER GATE INSTALLATION
The gate must be plumb, level, and swing freely on its hinges.
The gate must move throughout its arc without binding or dragging on the ground.
Wheels must NOT be attached to the gate.
Gates over 250 lb. should have ball bearing hinges with grease ttings.
Post must be secured in the ground with concrete (minimizes twist/ex when the operator is activated).
Make sure there is a stable area for mounting the gate bracket (this may require the addition of a horizontal or vertical cross member).
We recommend you position the operator near the center-line of a gate to keep the gate from twisting and exing, and to avoid back-splash from rain.
A
F
E
B
- Plumb
- Free Swinging
- Secured Posts in
Gate Grounding
For reference only.
Cooper Clad Ground Rod (not included)
Use an 8 foot, 5/8 inch ground rod, positioned two feet or less from the post and 2 inches or less above the ground. Available at local home center or hardware stores.
NOTE: No grounding system absolutely protects against lightning strikes. If installed correctly, a grounding system will help minimize damage to your gate operator.
C
E - Center line Mounting F - Good Working Hinges (ball bearing
hinges are recommended on gates over 250 pounds)
Metal Gate Post
3/16” Drilled
Pilot Hole
Copper Single
Conductor Lug
12awg or Larger
Ground
Copper clad ground rod
2 ft. or Less
from post
Copper ground
rod clamp
D
(not included)
6 ft. deep or more
2 Inches or Less above
ground
Ground
xii MM571W / MM572W Installation Instructions
ITEMS INCLUDED FOR PRIMARY GATE OPENER INSTALLATION (MM571W)
A
Battery Box, Control Box,
Antenna, Battery
& Battery Harness
J
8” Nylon Cable Tie (10)
M
3/8” x 8” Bolt (4)
P
3/8” x 2-3/4” Bolt (2)
Gate Bracket
Post Pivot Bracket
Q
5/16” x 1-1/2” Bolt (1)
B
Operator
Arm
Transformer
C
Closed Position
H
Stop Plate
D
Literature kit
with gate
warning signs
E
G
F
Post Brackets (2)
K
5/16” Clipped Washer (1)
N
Hairpin Clip (2)
R
2” Mounting Screw (4)
I
Transmitter
L
3/8” Washer (9)
O
3/8” x 1-1/2” Bolt (1)
S
3/8” x 1-1/2” Clevis Pin (2)
T
3/8” Nut (7)
U
5/16” Lock Nut (1)
V
3/8” Lock Washer (7)
W
ITEMS INCLUDED FOR SECONDARY OPENER INSTALLATION (MM572W)
B
Operator
Arm
E
Gate Bracket
J K
8” Nylon Cable Tie (10)
M
3/8” x 8” Bolt (4)
Closed Position
Stop Plate
F
Post Pivot Bracket
5/16” Washer (1)
N
Hairpin Clip (2)
H
G
Post Brackets
L
3/8” Washer (9)
O
3/8” x 1-1/2” Bolt (1)
#10-14 x 3/4” Screw (8)
P
3/8” x 2-3/4” Bolt (2)
T
3/8” Nut (7) 5/16” Lock Nut (1)
Q
5/16” x 1-1/2” Bolt (1)
U
R
2” Mounting Screw (4)
V
3/8” Lock Washer (7)
S
3/8” x 1-1/2” Clevis Pin (2)
MM571W / MM572W Installation Instructions xiii
TOOLS NEEDED
7/16” Bit
Drill
Level
1/2” Bit
7/32” Bit
Pliers
Clamps
ITEMS NOT INCLUDED
Low voltage wire will be needed to run from the transformer to the control box; length depends upon the distance between the transformer power supply and the control box. See Transformer/Solar and Battery Power Installation on page 16, and the accessory catalog.
PVC conduit.
If you have thin-walled tube or panel gates, see Reinforcing Gates for the Gate Brackets, next page.
Hack Saw
9/16”
wrench
Adjustable
Wrench
Pen
1/2”
wrench
Philips Head
Screwdriver
Wire
Stripper
Center
Punch
Flat Head
Screwdriver
Small
Flat Head
Surge protection for transformer.
Some types of installations require u-bolts.
Additional washers or a metal plate may be needed for wooden post.
Weatherproof cover for outdoor outlet and transformer.
If the post is larger than 6”, bolts longer than 8” are needed.
Hammer
Tape
Measure
Depending on the type of gate, a horizontal cross member or mounting plate may be needed to mount the front of the operator and gate bracket to the gate. See the Reinforcing Gates for the Gate Brackets examples, next page.
Pull-to-Open Option
Instructions begin on page 2.
xiv MM571W / MM572W Installation Instructions
CHECK DIRECTION OF GATE SWING
(Requires Push-To-Open Bracket
#FM148—NOT INCLUDED)
Your Property Your Property
Push-to-Open Option
Instructions begin on page 8.
Mechanical Installation
Gate Bracket
Panel Gate
1" x 6"
Wood
Reinforcement
Gate Bracket
Wood or Metal Reinforcement
(not supplied)
ASSESSING THE GATE FOR INSTALLATION
Your gate operator can be mounted to a variety of gate types. This section shows some of the most common, along with the reinforcement methods recommended prior to or while mounting your gate operator.
Reinforcing Gates for the Gate Brackets
We recommend using a mufer clamp, wood, or metal, to reinforce thin-walled tube gates, or wood to reinforce panel gates as shown. These reinforcement methods will prevent damage to the opener and gate. Additional hardware may be needed depending on the installation. Additional hardware necessary but not included.
Muffler Clamp (not supplied)
Gate Bracket
Thin Walled Tube Gate
Mufer Clamp for Gate Bracket
Wood or Metal Reinforcement 1” x 6” Reinforcement