This equipment is similar to other gate or door equipment and meets or exceeds
Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has
hazards associated with its use and therefore by installing this product the installer
and user accept full responsibility for following and noting the installation and safety
instructions. Failure to follow installation and safety instructions can result in hazards
developing due to improper assembly. You agree to properly install this product and
that if you fail to do so Gates That Open, LLC, shall in no event be liable for direct,
indirect, incidental, special or consequential damages or loss of profits whether based
in contract tort or any other legal theory during the course of the warranty or at any
time thereafter. The installer and/or user agree to assume responsibility for all liability
and use of this product releasing Gates That Open, LLC, from any and all liability.
If you are not in agreement with this disclaimer or do not feel capable of properly
following all installation and safety instructions you may return this product for full
replacement value.
READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to
install and use this automatic gate opener. This gate opener produces a high level of
force. Stay clear of the unit while it is operating and exercise caution at all times.
All automatic gate openers are intended for use on vehicular gates only.
This product meets and exceeds the requirements of UL 325, the standard which regulates gate
opener safety, as established and made effective March 1, 2000, by Underwriters Laboratories Inc.
GTO Sales: 850-575-0176 • Fax 850-575-8912
GTO Technical Service 850-575-4144
For 24 hour/day, 7 day/week Technical Service visit http://support.gtoinc.com
For more information on Mighty Mule’s full line of Automatic Gate Openers and Access Controls visit www.mightymule.com
Printed in China for Gates That Open, LLC.
rev 07.12.12
Class Rating
The Mighty Mule Gate Opener is intended for use with vehicular swing gates in single family
residential applications. The opener is system certified to be in compliance with UL 325, current
edition, as of publication date.
Vehicular Gate Opener Class Categories:
Residential Vehicular Gate Opener—Class I: A vehicular gate opener (or system) intended for use in
a home of one-to-four single family dwellings, or a garage or parking area associated therewith.
Commercial/General Access Vehicular Gate Opener—Class II: A vehicular gate opener (or system)
intended for use in a commercial location or building such as a multifamily housing unit (five or more
single family units), hotel, garages, retail store, or other building servicing the general public.
Industrial/Limited Access Vehicular Gate Opener—Class III: A vehicular gate opener (or system)
intended for use in an industrial location or building such as a factory or loading dock area or other
locations not intended to service the general public.
Restricted Access Vehicular Gate Opener—Class IV: A vehicular gate opener (or system) intended
for use in a guarded industrial location or building such as an airport security area or other restricted
access locations not servicing the general public, in which unauthorized access is prevented via
supervision by security personnel.
Converting Metric Units to English Equivalents
When You Know Multiply By To Find Symbol
centimeters 0.3937 inches in. (or ")
meters 3.2808 feet ft. (or ')
kilograms 2.2046 pounds lb. (or #)
Converting English Units to Metric Equivalents
When You Know Multiply By To Find Symbol
inches 2.5400 centimeters cm
feet 0.3048 meters m
pounds 0.4535 kilograms kg
Converting Temperature
deg. Celsius (°C x 1.8) + 32 deg. Fahrenheit °F
deg. Fahrenheit (°F-32) ÷ 1.8 deg. Celsius °C
FOR YOUR RECORDS
Please record the following information product serial number (located under rear mount on arm), be sure to
keep all receipts for proof of purchase. Refer to this information when calling GTO for service or assistance
with your automatic gate opener.
Serial Number: ___________________________________ Date of Purchase: ________________
Place of Purchase: ___________________________________________________________________
ii
rev 07.12.12
Table of Contents
Gate Opener Class Categories ..................................................................... inside cover
Units and Standards Conversion Chart ........................................................ inside cover
PLEASE READ THIS FIRST! .................................................................... page iv
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Important Safety Instructions ......................................................................... 1
Disconnecting the Opener ........................................................................................1
Important Safety Instructions for the Consumer ......................................................2
Required Safety Precautions for Gates ....................................................................4
Secondary Means of Protection Against Entrapment ..............................................5
Warning Signs and Labels ........................................................................................6
Thank you for purchasing a Mighty Mule Gate Opener — GTO's “do-it-yourself” automatic gate opener! When
correctly installed and properly used, your Mighty Mule Gate Opener will give you many years of reliable service.
Please read the following information and watch the enclosed video to ensure you have the correct system for
your particular needs. Furthermore, this manual and the video will enable you to properly install your Mighty
Mule Gate Opener.
The Mighty Mule Gate Opener is designed for installation on a Pull-To-Open single leaf gate (gate that
opens into the property). By purchasing an accessory bracket [FM148], the Mighty Mule Gate Opener can
accommodate a Push-To-Open single leaf gate (gate that opens out from the property). Please see Pull-To-
Open/Push-To-Open diagram on page 9. The gate must not exceed 8 ft. or 550 lbs or exceed 16 ft. and 150 lbs.
(see Technical Specications on page 7). The Mighty Mule Gate Opener can be used on vinyl, aluminum, chain
link, farm tube, and wrought iron gates.
Use on solid (surface) gates is not recommended. Solid surface gates have a high resistance
to the wind. If the wind is strong enough, the opener will obstruct and stop, blow fuses, or may
damage the equipment.
The Mighty Mule Gate Opener features an adjustable stall force setting. This safety feature makes the gate
stop and reverse direction within 2 seconds when it comes in contact with an obstruction. The MIN setting
means the gate will exert the minimum force on an obstruction before it stops and reverses direction. You will need to adjust the stall force for your particular application.
The Mighty Mule Gate Opener also has an adjustable auto-close feature. After the gate reaches the fully
open position, it can be set for OFF, or to remain open up from 3 to 120 seconds before automatically closing.
Pressing the transmitter button at any time after the gate opens fully will cause it to close immediately. The autoclose factory setting is OFF, meaning the gate will stay open until you press the transmitter (or keypad, etc.)
again.
The Mighty Mule Gate Opener accommodates extra transmitters, digital keypads, solar panels, and other
access control products.
PLEASE NOTE—If your application requires any of the following:
Column Mounting
Slide gates
Swing gates longer than 16 feet or weighing more than 550 pounds
Professional installation
Please call GTO at 800-543-4283 or 850-575-0176 for information about our GTO/ACCESS SYSTEMS
professional line of gate openers and accessories. Our Sales Department will be glad to give you the
name and phone number of a GTO/ACCESS SYSTEMS dealer near you.
BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPENER:
Read these instructions carefully and completely to become familiar with all parts and installation
steps. The video is only designed as an overview of the installation procedure. You must read the
installation manual for detailed instructions on gate opener safety and proper use of the gate opener
All Mighty Mule Gate Openers run off of 12 volt battery power. This installation requires the battery
charge to be maintained by either a 18 volt transformer OR an optional solar panel connected by 16
gauge, low voltage, stranded, dual conductor, direct burial wire.
NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME!
iv
It will damage the control board
rev 07.12.12
IMPORTANT SAFETY INSTRUCTIONS
Because automatic gate openers produce high levels of force, consumers need to know the potential
hazards associated with improperly designed, installed, and maintained automated gate opener
systems. Keep in mind that the gate opener is just one component of the total gate operating system.
Each component must work in unison to provide the consumer with convenience, security, and safety.
This manual contains various safety precautions and warnings for the consumer. Because there are
many possible applications of the gate opener, the safety precautions and warnings contained in this
manual cannot be completely exhaustive in nature. They do, however, provide an overview of the
safe design, installation, and use of this product. CAREFULLY READ AND FOLLOW ALL SAFETY
PRECAUTIONS, WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE
SYSTEM DESIGN, INSTALLATION, AND USE OF THIS PRODUCT.
Precautions and warnings in this manual are identified with this
identifies conditions that can result in damage to the opener or its components, serious injury, or
death.
Because automatic gate openers are only part of the total gate operating system, it is the
responsibility of the consumer to ensure that the total system is safe for its intended use.
warning symbol. The symbol
How To Manually Open and Close the Gate:
CAUTION: The gate can be opened and closed manually when the opener is disconnected.
ONLY disconnect the opener when the opener power switch is OFF and the gate is NOT moving.
Because the Mighty Mule gate opener is battery powered, disconnect the opener ONLY when the
power switch on the control box is turned OFF. Unplugging the transformer does not turn power to the
opener OFF.
Front Mount
Clevis Pin
Gate Bracket
Disconnecting the Opener
1. Turn opener power switch (Control Box) OFF.
2. Remove hairpin clip, clevis pin, and bushing
from the front mounting point.
3. Remove the opener from the mount
NOTE: Substitute a Pin Lock [FM133] for the clevis pin on
the front mount of the gate opener to prevent unauthorized
removal of the opener from the gate.
(See accessories on pg. 38)
rev 07.12.12
1
Bushing
Hairpin Clip
IMPORTANT SAFETY INSTRUCTIONS
Gate in the
Open Position
ZONE 2
ZONE 3
ZONE 4
ZONE 5
Driveway
ZONE 1
For The Consumer
WARNING: To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS. Failure to meet the requirements set forth in the instruction manual
could cause severe injury or death, for which the manufacturer cannot be held responsible.
2. When designing a system that will be entered from a highway or main thoroughfare, make sure the system is
placed far enough from the road to prevent trafc congestion.
3. The gate must be installed in a location that provides adequate clearance between it and adjacent structures when
opening and closing to reduce the risk of entrapment. Swinging gates must not open into public access areas.
4. The gate and gate opener installation must comply with any applicable local codes.
I. Before Installation
1. Verify this opener is proper for the type and size of gate, its frequency of use, and the proper class rating.
2. Make sure the gate has been properly installed and swings freely in both directions. Repair or replace all worn
or damaged gate hardware prior to installation. A freely moving gate will require less force to operate and will
enhance the performance of the opener and safety devices used with the system.
3. Review the operation of the system to become familiar with its safety features. Understand how to disconnect the
opener for manual gate operation (page 1).
4. This gate opener is intended for vehicular gates ONLY. A separate entrance or gate must be installed for
pedestrian use (page 4).
5. Always keep people and objects away from the gate and its area of travel. NO ONE SHOULD CROSS THE
PATH OF A MOVING GATE.
6. Pay close attention to the diagram below and be aware of these areas at all times.
Entrapment Zones for a proper Pull-To-Open installation:
Zone 1 – leading edge of the gate.
Zone 2 – between the gate and the gate post.
Zone 3 – the path of the gate.
Zone 4 – the space between the gate in the open position and any object such as a wall, fence, etc.
Zone 5 – pinch points between the opener and gate.
2
rev 07.12.12
IMPORTANT SAFETY INSTRUCTIONS
Moving Gate
Area
Driveway
10'
10'
10'
10'
NEVER INSTALL
any control device
within gray area
II. During Installation
1. Install the gate opener on the inside of the property and fence line. DO NOT install an opener on the outside of the
gate where the public has access to it.
2. Be careful with moving parts and avoid close proximity to areas where ngers or hands could be pinched.
3. Devices such as contact sensors (safety edges) and non contact sensors (photo beams) provide additional
protection against entrapment.
4. If push buttons or keypads are installed, they should be within sight of the gate, yet located at least 10 feet from
any moving part of the gate (see diagram below). Never install any control device where a user will be
tempted to reach through the gate to activate the gate opener.
5. Do not activate your gate opener unless you can see it and can determine that its area of travel is clear of people,
pets, or other obstructions. Watch the gate through its entire movement.
6. Secure outdoor or easily accessed gate opener controls in order to prohibit unauthorized use of the gate.
III. After Installation
1. Attach the warning signs (included) to each side of the gate to alert the public of auto matic gate operation. It
is your responsibility to post warning signs on both sides of your gate. If any of these signs or warning decals
become damaged, illegible or missing, replace them immediately. Contact GTO for free replacements.
2. The gate is automatic and could move at any time, posing a serious risk of entrapment. No one should be in
contact with an activated gate when it is moving or stationary.
3. Do not attempt to drive into the gate area while the gate is moving; wait until the gate comes to a complete stop.
4. Do not attempt to “beat the gate” (drive through) while the gate is closing. This is extremely dangerous.
5. Do not allow children or pets near your gate. Never let children operate or play with gate controls. Keep ALL
gate controls away from children and unauthorized users; store controls where children and unauthorized users do
not have access to them.
6. KEEP GATE AND GATE OPENER PROPERLY MAINTAINED. Always turn power to opener OFF before
performing any maintenance. Regularly grease the gate hinges. Apply silicone spray to a soft, dry cloth and clean
the push-pull tube at least once a month.
rev 07.12.12
3
IMPORTANT SAFETY INSTRUCTIONS
7. To operate this equipment safely, YOU must know how to disconnect the opener for manual gate operation
(page 1). If you have read the instructions and still do not understand how to disconnect the opener, contact the
GTO Service Department.
8. Disconnect the opener ONLY when the power is TURNED OFF and the gate is NOT moving.
9. Make arrangements with local re and law enforcement for emergency access.
10. Distribute and discuss copies of the IMPORTANT SAFETY INSTRUCTIONS section of this manual with all
persons authorized to use your gate.
11. IMPORTANT: Save these safety instructions. Make sure everyone who is using or will be around the gate
and gate opener are aware of the dangers associated with automated gates. In the event you sell the
property with the gate opener or sell the gate opener, provide a copy of these safety instructions to the
new owner.
Should you lose or misplace this manual, a copy can be obtained by downloading one from mightymule.com,
or by contacting Gates That Open, LLC., at 3121 Hartsfield Road, Tallahassee, Florida 32303 or by calling
1-800-543-4283 and requesting a duplicate copy. One will be provided to you free of charge.
Required Safety Precautions for Gates
Install Warning Signs
Warning signs alert people of automatic gate operation and are required when installing the Mighty Mule Gate Opener.
The warning signs included must be installed on both sides of each gate. Furthermore, a walk-through gate must be
installed if pedestrian trafc is expected near the vehicular gate.
Entrapment Protection
GTO’s inherent obstruction settings, even when properly adjusted, may not be sensitive enough to prevent bodily
injury in some circumstances. For this reason, safety devices such as safety edge sensors (or photoelectric sensors),
which stop and reverse gate direction upon sensing an obstruction, are suggested for enhanced protection against
entrapment.
Pedestrian Gate Lock
(recommended, not included)
Pedestrian Gate
Photo Beam (R4222)
(recommended, not included)
Warning labels should be placed at the locations specified.
If any of them are missing, immediately contact GTO for
replacements.
Contact Sensor
(recommended, not included)
Warning Sign
Vehicular Gate
Contact Sensor
(recommended, not included)
Photo Beam (R4222)
(recommended, not included)
4
rev 07.12.12
IMPORTANT SAFETY INSTRUCTIONS
Vehicular Gate
Leading Edge Contact Sensor
on both sides of the gate
Bottom Edge Contact Sensor
on both sides of the
g
ate
Post Edge Contact Sensor
on both sides of the gate
Secondary Means of Protection Against Entrapment
As specied by Gate Opener Safety Standard, UL 325 (30A.1.1), automatic gate openers shall have an inherent
entrapment sensing system, and shall have provisions for, or be supplied with, at least one independent secondary
means to protect against entrapment. The Mighty Mule Gate Opener utilizes Type A, an inherent (i.e., built-in) entrapment
sensing system as the primary type of entrapment protection. Also, the Mighty Mule Gate Opener has provisions for the
connection of Type B2 protection to be used as the secondary type of entrapment protection, if desired.
1. For gate openers utilizing a contact sensor (e.g., safety edge sensor– Type B2) in accordance with UL 325 (51.8.4
[i]):
A. One or more contact sensors shall be located at the leading edge, bottom edge, and post edge, both inside and
outside of a vehicular swing gate system.
B. A hard wired contact sensor shall be located and its wiring arranged so that the communication between the
sensor and the gate opener is not subjected to mechanical damage.
C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate opener for
entrapment protection functions shall be located where the transmission of the signals are not obstructed or
impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall
function under the intended end-use conditions.
You may want to consider adding photo beams (R4222) to your installation. Photo Beams provide a “non contact” means
of entrapment protection. Call 1-800-543-GATE (4283) for more information.
ENTRAPMENT ALARM (UL 325; 30A.1.1A)
The Mighty Mule Gate Opener is designed to stop and reverse within 2 seconds when the gate comes
in contact with an obstruction. Additionally, these openers are equipped with an audio entrapment alarm which will activate if the unit obstructs twice while opening or closing. This alarm will sound for a
period of 5 minutes, or until the opener receives an intended signal from a hard wired entry/exit source
(e.g. push button control or keypad) and the gate returns to a fully open or fully closed position. Turning
the power switch on the control box OFF and back ON will also deactivate the alarm. Wireless controls
such as transmitters and wireless keypads will not deactivate the alarm.
rev 07.12.12
5
Warning signs (2 enclosed) to be installed on each side
of the gate (3–5 feet above the bottom of the gate)
Product identification label (1)
installed under rear mount on arm.
Logo and warning labels (2) installed on each side of opener housing
GTO DC SWING SERIES
Conforms to UL325
5th Edition Standards
Serial No.
MM350-
0000000
xxxxxx
Gates That Open, LLC - Tallahassee, Florida USA
!
If any of these signs or warning decals become damaged, illegible or missing, replace them immediately.
Contact GTO at 1-800-543-GATE (4283) for free replacements.
9901178
1-800-543-GATE (4283) • www.mightymule.com
1. KEEP CLEAR! Gate may move at any time.
2. Do not allow children to operate gate or play in gate area.
3. This gate is for vehicles only. Pedestrians must use separate entrance.
Can Cause Injury or Death
MOVING
GATE!
®
E-Z GATE OPENER
UL325 SERIES
®
350
!!
TO MANUALLY OPEN AND CLOSE THE GATE
1. Turn opener power switch OFF.
2. Disconnect front or rear mount from
mounting bracket.
3. Pull opener away from mounting bracket
and move gate.
Disconnect opener ONLY when the power
switch is OFF and the gate is not moving.
Maximum Gate: 550 lbs. (158.8 kg); 16 ft. (4.9 m) • Voltage: 12 Vdc; Frequency: 0Hz; Power: 25W • Class I Vehicular Swing Gate Operator
IMPORTANT SAFETY INSTRUCTIONS
6
rev 07.12.12
Technical Specifications
Gate Weight
Gate Length
Number of Cycles Per Day
Mighty Mule 350 Gate Capacity /Cycle Chart
Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery.
• Low friction screw drive (linear actuator) rated for -5 °F to +160 °F (-20 °C to +71 °C).
• Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 260 rpm.
• Maximum opening arc of 110°. Approximate opening time (90°): 18 seconds, depending on weight of gate.
_____________________________________
POWER
• The system is powered by a 12 Vdc automotive or marine battery.
• Battery charge is maintained by a 120 Vac, 18 Vac output transformer (40 VA) through the GTO control board or
by optional GTO Solar Panels; the panel should generate minimum of 5 Watts at 300 mA. IMPORTANT: Never
use both transformer and solar panel— this will damage the battery and control board.
• One (1) blade-style fuse is rated for 15 A.
NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with
higher ampere rated fuses; doing so will void your warranty and may damage your control board.
_____________________________________
CONTROL
• GTO DIP switches are set for single leaf, pull-to-open gate installations. DIP switches can be adjusted to
accommodate push-to-open gates.
• A circuit on the control board regulates charging. “Sleep draw” is 25 mA; “active draw” is 2 to 5 A.
• Auto-memorization of digital transmitter code.
• GTO RF Receiver tuned to 318 MHz.
• Opener length with push-pull tube fully retracted is 37 1/4", mounting point to mounting point. Maximum stroke
is 19".
• Adjustable auto-close timer (OFF to 3–120 seconds), and obstruction sensitivity (stall force).
• Power terminal block accommodates a transformer or solar panels.
• Accessory terminal block fully compatible with all Mighty Mule access controls.
• Control board allows connection of safety edge sensors and photoelectric sensors.
• Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.
_____________________________________
OPERATIONAL CAPACITY
• The Gate Capacity Chart shows approximate cycles, per day, you can expect from the Mighty Mule Gate Opener
when powered with a transformer. Actual cycles may vary slightly depending upon the type and condition of gate
and installation.
_____________________________________
_____________________________________
_____________________________________
_____________________________________
An operation cycle is
one full opening and
closing of the gate.
NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LBS.
To determine the number of cycles the gate opener will perform using solar panels, please see the
rev 07.12.12
7
specications listed on page 8.
* These specifications
are subject to change
without notice.
Before You Begin
1. Determine Charging Options for Battery: Transformer OR Solar
NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME!
conductor, stranded, direct burial wire. Do not run more than 1000 ft. of wire.
Solar Panel and Gate Activity Chart
The table and map illustrate the maximum number of gate cycles to expect per day in a particular area
when using from 5 to 30 watts of solar charging power. The gures shown are for winter (minimum sunlight)
and do not account for the use of
any accessory items.
Accessories connected to your
system will draw additional power from
the battery and will require additional solar
panels.
NOTE: UP to 250 ft. of 16 gauge dual
conductor, stranded, direct burial wire may
be used to allow installation of solar panels in
direct sunlight.
Solar Charging Options
• 10 Watt Mighty Mule Solar Panel [FM123]
• 5 Watt Mighty Mule Solar Panel [FM121]
(See accessories on pg. 38)
Single Gate Winter Ratings Zone 1 Zone 2 Zone 3
12 v single gate (5 watts) solar charger 4 8 13
12 v single gate (10 watts) solar charger 8 16 26
12 v single gate (15 watts) solar charger 11 20 30
12 v single gate (20 watts) solar charger 14 28 38
12 v single gate (25 watts) solar charger 17 36 46
12 v single gate (30 watts) solar charger 20 44 54
8
rev 07.12.12
2. Check Direction of Gate Swing
Your PropertyYour Property
The Mighty Mule Gate Opener is designed for PULL-TO-OPEN installations. PUSH-TO-OPEN installations require a
Push-To-Open bracket [FM148]. Push-to-Open Installation Instructions begin on page 31.
Pull-To-Open
(arm retracts to open)
Push-To-Open
(arm extends to open)
3. Prepare the Gate
• The gate must be plumb, level, and swing freely on its hinges.
• Wheels must NOT be attached to the gate.
• The gate must move throughout its arcs without binding or dragging on the ground.
• Note that a gate over 250 lbs. should have ball bearing hinges with grease ttings.
• The gate post should be secured in the ground with concrete so it will minimize twist or ex when the opener is
activated.
• Make sure there is a stable area for mounting the gate bracket (this may require the addition of a horizontal or
vertical cross member).
A
F
E
B
Horizontal Cross Member
C
A – Level D – Posts Secured in Concrete
B – Plumb E – Centerline Mounting
C – Free Swinging F – Good Working Hinges
rev 07.12.12
9
Vertical Cross Member
D
Parts List – Opener and Mounting Hardware
Hairpin Clip (2)
3/8" x 1-1/2" Clevis Pin (2)
5/16" x 1-3/4" Bolt (1)
3/8" x 2" Bolt (1)
3/8" x 2-3/4" Bolt (2)
3/8" x 8" Bolt (4)
8" Nylon Cable Tie (14)
3/8" Washer (9)
3/8" Lock Washer (7)
5/16" Washer (1)
3/8" Nut (7)
5/16" Nut (1)
Hardware Bag Contents
Gate Opener (1)
Gate Bracket (1)
Post Pivot Bracket (1)
3/8" Bushings (2)
Customer Support Card (1)
Post Bracket (2)
Closed Position
Stop Plate (1)
2" Mounting Screw (5)
®
E-Z GATE OPENER
Transformer (1)
10’ Battery Wire
Harness (1)
Warning Signs (2)
Transmitter (1)
1. KEEP CLEAR! Gate may move at any time.
2. Do not allow children to operate gate or
play in gate area.
3. This gate is for vehicles only. Pedestrians
must use a separate entrance.
Moving Gate Can Cause
Injury Or Death
WARNING
!
Receiver (1)
Installation
Video
Installation Overview for the...
10
rev 07.12.12
Loading...
+ 30 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.