PT 8303 SL EL (Electrically Heated)
16.15
M.-Nr. 10 007 270 / 02

U.S.A.
Miele, Inc.
National Headquarters
9 Independence Way
Princeton, NJ 08540
Phone:
Fax:
800-991-9380
609-419-4241
www.mieleusa.com
Technical Service & Support
Nationwide
Phone:
Fax:
800-991-9380
800-220-1348
proservice@mieleusa.com
It is essential to read the operating and installation instructions before
installing, commissioning or using the machine.
This avoids the risk of accidents or damage.
2

28
PT 8303 SL EL - measurements in inches
3/4
70 7/8
27 7/8 3/4
20 1/2
31 7/8
70 7/8
2 1/2
39 1/2
42 7/8
39 3/8
25 5/8
24 3/4
1
29 3/4
3/4
59

42 7/8
PT 8303 SL EL - measurements in inches
27 7/8
28
39 3/8
59
2
5 7/8
6 1/4
6 3/8

24 3/8 3 1/2
PT 8303 SL EL - measurements in inches
66 7/8
5 1/4
10 1/8
13 3/8
9 1/4
12 1/4
66 7/8
10 1/8

70 7/8
PT 8303 SL EL - measurements in inches
5 1/8
3/4
59
1 3/8
39 3/8
25 1/4
27 7/8
1 3/8
12 5/8
19 1/8
39 7/8
2
2
3/8

PT 8303 SL EL - measurements in millimeters

PT 8303 SL EL - measurements in millimeters

PT 8303 SL EL - measurements in millimeters

PT 8303 SL EL - measurements in millimeters

Abbreviations in bold type:
Connection required
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Machine connections:
Electrical
connection
Vented
Air intake
Standard voltage 3 AC 220 - 240 V
Frequency 60 Hz
Rated load 15.4 kW
Fuse rating 3 x 40 A
Supply lead cross-section 4 x 6 mm² 4 × 10 AWG
Convertible to 3 AC 208 V
Frequency 60 Hz
Rated load 11.7 kW
Fuse rating 3 x 35 A
Supply lead cross-section 4 x 6 mm² 4 x 10 AWG
Convertible to 2 AC 208 V
Frequency 60 Hz
Rated load 8.1 kW
Fuse rating 2 x 40 A
Supply lead cross-section 3 x 6 mm² 3 x 10 AWG
Electrical connection must comply with national regulations.
A wall socket or main isolator must be easily accessible after
installation.
Reinstallation of the supply point, changes to the equipment
or checks on the protective conductor, including determination
of correct fuse rating, should only be performed by a trained
electrician.
Nominal air throughput in vented mode
Max. permissible pressure loss
Waste air/gas temperature, max.
Connector on machine (int. diameter)
Connection pipe provided on site (ext. diameter)
As relative humidity inside the vent ducting can be as high as
100%, suitable measures must be taken to prevent a backflow of condensate into the machine.
Standard Connection:
Air intake from installation site
Min. air intake cross-section
(to prevent draughts in room)
A sufficient supply of fresh air should be ensured to replace
the air extracted.
821 m³/h
300 Pa
80 °C
150 mm
150 mm
531 cm²
28993 cfh
0.0435 psi
176 °F
5 15/16“
5 15/16“
82.305 in²
Alternative connection:
ing)
buildConnect
or on machine (int. diameter)
Connection pipe provided on site (int. diameter)
Lid removal exposes live components! For safety reasons,
the pipe connected for central air intake should be at least
900 mm long and secured using two screws.
Technical datasheet: PT 8303 SL EL
Date: 24-Jun-2014
Ducted air intake (from outside
161 mm
160 mm
6 5/16”
6 5/16”
9

Fittings
(supplied)
Machine data
Installation should only be carried out by authorized installers in accordance with national regulations! Follow installation
instructions when installing machine!
Without base
2 x clamps
4 × screws DIN 571 (Ø × length) 6 mm x 40 mm
4 × rawl plugs (Ø × length) 10 mm x 50 mm
The machine should be bolted to the floor.
Fixing materials for a floating screed floor are to be provided
on site.
Width 711 mm 28“
Depth 1088 mm 42 7/8“
Height 1800 mm 70 7/8“
Casing width 708 mm 27 7/8“
Casing depth 999 mm 39 5/16“
Minimum width of delivery access to installation site 725 mm 28 9/16“
Minimum rear wall gap (measured to front of machine) 1500 mm 59 1/16“
Wall gap (to front of machine)
Minimum gap ensures sufficient space for maintenance and
servicing.
Net weight 139 kg 306.4 lbs
Dynamic floor load, max. 1584 N
Average heat dissipation
(dependent on ambient room temperature and programme
selected)
Noise level 68.9dB (A)
Sound pressure (re 20 mPA),
workplace-related (at distance of 1 m and height of 1.6 m)
500 mm 19 11/16“
473 W 1615 BTU/h
56 dB (A)
1/4” x 1 9/16”
3/8” x 2”
Technical datasheet: PT 8303 SL EL
Date: 24-Jun-2014
10