Miele DAR 1230, DAR 1130, DAR 1250, DAR 1150, DAR 1220 User Manual

...
Installation Instructions
DAR 1120, DAR 1130 en - CA DAR 1150, DAR 1220 DAR 1230, DAR 1250
Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations and the provided installation instructions.
Caring for the environment
The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle.
DANGER
,
Ensure that any plastic wrappings, bags, etc., are disposed of safely and kept out of the reach of babies and young children. Danger of suffocation!
Disposal of an old appliance
Old appliances may contain materials that can be recycled. Please contact your local recycling center about the possibility of recycling these materials.
Before discarding an old appliance, disconnect it from the electrical supply and cut off the power cord to prevent it from becoming a hazard.
18
Appliance dimensions
19
Appliance dimensions
20
Appliance dimensions
a The hood with exhaust collar is only used in air venting mode with an internal or external blower.
b Installation area; Wall/ceiling area respectively for vent hole and outlet installation. For recirculation mode only the outlet installation is required.
21
Appliance dimensions
a The hood with exhaust collar is only used in air venting mode with an internal or external blower.
b Installation area; Wall/ceiling area respectively for vent hole and outlet installation. For recirculation mode only the outlet installation is required.
22
Appliance dimensions
a Installation area; Wall/ceiling area respectively for vent hole and outlet installation.
23
Appliance dimensions
Distance between cooktop and hood (S)
Do not install this exhaust hood over cooktops burning solid fuel.
Observe the cooktop manufacturer's instructions when determining the distance between cooktop and lower edge of the hood. Unless the instructions require a greater distance, the adjacent minimum safety distances apply for Miele cooktops.
– If several gas surfaces are installed under the hood, the total output must be
considered when determining the minimum safety distance.
– Be sure to follow the minimum safety distances given by the gas cooktop
manufacturer to easily flammable materials e.g. upper cabinets.
– If local building codes require a greater safety distance, follow their requirement.
– If there is more than one appliance beneath the hood and they have different
minimum safety distances always select the greater distance.
See "Important Safety Instructions" for further information.
– To ensure free access to work under the ventilation hood, a distance of a
minimum of 26" (660 mm) above the electric cooktop is also recommended.
– Take the user's body height into consideration when selecting the installation
height. Adequate work space at the cooktop and optimal operation of the ventilation system should be ensured.
– However, the greater the distance from the cooktop, the less effectively cooking
odors are drawn in.
24
Miele Range Wall / Insert Hood
Internal / External blowers
Miele Electric Cooktops
Miele Electric Barbeques and Fryers
Miele Multiburner Gas cooktops <
43,000 BTU/hr (12.6 kW) and no burner >19,800 BTU/hr (5.8 kW)
Miele Multiburner Gas cooktops > 43,000 BTU/hr (12.6 kW) <
92,200 BTU/hr (27 kW) and no burner >19,800 BTU/hr (5.8 kW)
Miele Multiburner Gas cooktops > 92,200 BTU/hr (27 kW) <
112,600 BTU/hr (33 kW) and no burner >19,800 BTU/hr (5.8 kW)
Miele Multiburner Gas cooktops > 112,600 BTU/hr (33 kW) <
142,600 BTU/hr (41.8 kW) and no burner >19,800 BTU/hr (5.8 kW)
Miele Multiburner Gas cooktops > 142,600 BTU/hr (41.8 kW)
Miele Multiburner Gas cooktops one of the burners >19,800 BTU/hr (5.8 kW)
Miele Single burner (Wok) <
20,500 BTU/hr (6 kW)
Miele Single burner (Wok) > 20,500 BTU/hr (6 kW) <
27,600 BTU/hr (8.1 kW)
Miele Single burner (Wok) > 27,600 BTU/hr (8.1 kW)
Distance between cooktop and hood (S)
DAR 1120,
DAR 1220
(30")
DRIB/DREB
XL
(700 cfm)
not
possible
Appliance dimensions
DAR 1130, DAR 1230
DRIB/DREB
(700 cfm)
36" (910 mm) 30" (760 mm)
not
possible
(36")
XL
24" (610 mm)
26" (660 mm)
26" (660 mm)
30" (760 mm)
not possible
not possible
26" (660 mm)
30" (760 mm)
not possible
DRIB/DREB
XXL
(1100 cfm)
DAR 1150,
DAR 1250
(48")
DRIB/DREB
XXL
(1100 cfm)
36" (910 mm)
25
Plywood backing
The majority of the weight of the installed ventilation system will be supported by the retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. ½" (13 mm) thick) spanning at least two studs must be installed. Failure to adequately support the weight as stated may result in the ventilation system falling off the wall, causing personal injury and property damage.
(If plywood backing is not needed, proceed to the included "Installation diagram".)
To install a plywood backing
^ Find the studs to the left and right of
the mounting location by tapping the wall or using a stud finder.
^ Mark a vertical cutting line along the
center of each stud.
CAUTION
,
When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities.
^ Remove the drywall between the
cutting lines and replace it with plywood of a matching thickness (min. ½" (13 mm) thick). Tape the joints and refinish the wall.
^ Proceed to the enclosed "Installation
diagram" to complete the installation.
^ Determine and mark the location for
the canopy as outlined in "Appliance dimensions".
^ Make a cutting line 3" (76 mm) above
and 3" (76 mm) below the outline of the retaining plate.
26
Before installation read the information in the "Dimensions" and "Important Safety Instruction" chapters. Under certain conditions, there is a danger of poisonous fumes by when the ventilation system and a furnace drawing interior air run at the same time.
Installation instructions
The individual installation steps are described in the included Installation diagram.
Protective film
(stainless steel units)
The casing is covered with a protective film to prevent scratching during transport.
Installation
Please peel off the film before installing the casing parts. It can be removed without tools.
27
Air venting
WARNING
,
Danger of toxic fumes.
Exhaust ducting and connections
Use smooth or flexible pipework made from approved non-flammable materials for exhaust ducting.
Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only.
Do not vent exhaust air into spaces within walls or ceilings or in attics, crawl spaces or garages.
To reduce the risk of fire, only use metal ductwork.
Please read and follow the
"IMPORTANT SAFETY INSTRUCTIONS" to reduce the risk of
personal injury. Follow all local building codes when installing the hood.
To achieve the most efficient air extraction and quietest noise levels, consider the following:
– The diameter of the ductwork should
not be less than 8" (203 mm) with DRIB/DREB XL and 10" (254 mm) with DRIB/DREB XXL.
– If flat ducting is used, the cross
section must not be smaller than the cross section of the ventilation exhaust.
– The ducting should be as short and
straight as possible.
– Use ductwork with a wide radius.
– The exhaust duct must not be bent
or compressed.
– Make sure all connections are
secure.
– Where the ductwork is horizontal, it
must slope away from the hood at
1
least
/8" per foot (1 cm per meter) to prevent condensation dripping into the appliance.
28
– If the exhaust is ducted into an
inactive flue, the air must be expelled parallel to the flow direction of the flue.
Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue.
Important
Air venting
If the ductwork runs through rooms, ceilings, garages, etc. where temperature variations exist, it may need to be insulated to reduce condensation.
29
Electrical connection
,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
All electrical work should be performed by a qualified electrician in strict accordance with national regulations (for USA: ANSI-NFPA
70) and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. Ensure that power to the appliance is OFF while installation or repair work is performed.
^ Verify that the voltage, load and
circuit rating information found on the data plate (located behind the baffle filters), match the household electrical supply before installing the hood.
^ Use only with ventilation hood
cord-connection kits that have been investigated and found acceptable for use with this model hood.
Grounding Instructions
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing a path of least resistance. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
WARNING - Improper grounding can result in a risk of electric shock.
If there is any doubt, have the electrical system of the house checked by a qualified electrician.
Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.
Important
The hood comes equipped with a power cord with a NEMA 5-15 molded plug for connection to a 120 VAC, 60 Hz, 15 A power outlet.
If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or call Miele’s Technical Service Department.
,WARNING: THIS APPLIANCE MUST BE GROUNDED
30
Technical data
Total connected load
DAR 1120, DAR 1220
with DRIB XL or DREB XL ......621W
DAR 1130, DAR 1230
with DRIB XL or DREB XL ......624W
DAR 1130, DAR 1230
with DRIB XXL or DREB XXL ....809W
DAR 1150, DAR 1250
with DRIB XXL or DREB XXL ....812W
Overhead lights
DAR 1120, DAR 1220 ........2x3W
DAR 1130, DAR 1230 ........3x3W
DAR 1150, DAR 1250 ........4x3W
Power supply voltage ......... 120V
Frequency .................. 60Hz
Circuit rating..................15A
Length of power cord . . . 2.5 ft (0.75 m)
Weight
DAR 1120
with DRIB XL .......59.6 lbs (27.1 kg)
DAR 1220
with DRIB XL .......83.8 lbs (38.1 kg)
DAR 1130
with DRIB XL .......66.2 lbs (30.1 kg)
DAR 1130
with DRIB XXL ......66.7 lbs (30.3 kg)
DAR 1230
with DRIB XL.........97lbs(44.1 kg)
DAR 1230
with DRIB XXL ......97.5 lbs (44.3 kg)
DAR 1150
with DRIB XXL ......79.9 lbs (36.3 kg)
DAR 1250
with DRIB XXL .....130.5 lbs (59.3 kg)
3132333435
DAR 1120, 1130, 1150 DAR 1220, 1230, 1250
M.-Nr. 10 219 920 / 01en - US, CA