36” Pearl Wall
Ventilation Hood
DA 6996 W
Specification Sheets TRS 11152016
8mieleusa.com

36” Pearl Wall Ventilation Hood
DA 6996 W
SPECIFICATIONS
DA 6996 W — Item
Overall Unit Width 357/16” (900 mm)
Overall Unit Height 22
Overall Unit Depth 21
Fan
Fan Speeds 4, Including Intensive setting
DA 6996 W
Features:
• LED ClearView Lighting
• Con@ctivity 2.0 - communication
between hood and cooktop
• Dimmable ambient lighting in white
• No chimney (venting to back) but if
needed DADC 6000 in brilliant white
can be purchased
• Vented or recirculating possible
• Side-mounted controls or controllable
via optional remote control accessory
(DARC6)
• Four fan speeds (including intensive)
• Removable dishwasher-safe stainless
steel grease lter and drip tray
• Filter saturation indicator (grease and
charcoal lter)
• Delayed shutdown for 5 or 15 minutes
• Automatic shutdown of intensive level,
programmable for 10 minutes
Maximum CFM
Duct
Recommended Duct Diameter 6” (150 mm)
Electrical
Electrical Requirements 120V, 60Hz,15A
Power Cord Molded NEMA 5-15 plug, 2.5 ft (0.75 m)
Shipping
Shipping Weight 101.5 lbs (46 kg)
Shipping Dimensions 34
Support
Call Miele 800.843.7231
Miele Website
20/20 Link
28699630USA
15
/16” (583 mm)
1
/8” (537 mm)
625 CFM, (Reducing Collar is available to
reduce air flow to less than 400 CFM)
7
/8” W x 25” H x 41” D
8www.mieleusa.com
82020technologies.com
Optional Accessories:
DADC 6000 BRWS
Chimney attachment
Reducing collar
Reducing collar for use
with 5” (125 mm) exhaust
ducting. Lowers air ow to
less than 400 CFM
DKF25-900
OdorFree Charcoal lter
required accessory for
recirculation mode
DARC6
Remote control for
ventilation hood
DA 6996 W
Specification Sheets TRS 11152016
Page 2 of 6

36” Pearl Wall Ventilation Hood
DA 6996 W
INSTALLATION SPECIFICATIONS
DA 6996 W
Specification Sheets TRS 11152016
Page 3 of 6

36” Pearl Wall Ventilation Hood
DA 6996 W
INSTALLATION SPECIFICATIONS
Mounting Details
• Center unit over cooking surface
• Distances “S” is determined by the cooking surface. See “Distance between cooktop and hood (S)”
dimensions.
• If studs are not available in the required locations, a plywood backing (min.
reinforce support. Reinforcing material should be afxed to structural wall members. Failure to adequately
support the weight as stated may result in the ventilation system falling off the wall, causing personal injury
and property damage.
1
/2” (13 mmm)) MUST be used to
Specification Sheets TRS 11152016
DA 6996 W
Page 4 of 6

36” Pearl Wall Ventilation Hood
DA 6996 W
INSTALLATION SPECIFICATIONS
Distance Between Cooktop and
Ventilation Hood (S)
DA 6996 W
Specification Sheets TRS 11152016
Page 5 of 6

36” Pearl Wall Ventilation Hood
DA 6996 W
INSTALLATION SPECIFICATIONS
Optional Chimney Details
DADC 6000 BRWS
DA 6996 W
Specification Sheets TRS 11152016