Miele DA6891EB Specifications

36” Downdraft Hood Flush Mounting
DA 6891 Levantar
Shown: KM 6375 with DA 6891 Flush Mounted Please note: This information is subject to change
Specification Sheets TRS 08122019
8mieleusa.com
36” Downdraft Hood
Flush Installation
SPECIFICATIONS
Overall Unit Dimensions 36” (915 mm) W x 2511/16” (652 mm) H (Unextended) x 43/4” (120 mm) D
Overall Canopy Height 16” (406 mm)
Built-In
Minimum Opening Dimensions 3115/16” (812 mm) W x 2513/16” (656 mm) H (Including Countertop) x 41/4” (108 mm) D
Fan
Fan Speeds 4
Maximum CFM
Duct
Duct Diameter
Electrical
Electrical Requirements 120V, 60Hz,15A
Power Cable Ventilation system must be hard wired
Shipping
Shipping Weight 74 lbs (33.6 kg)
Shipping Dimensions 427/8” W x 305/8” H x 107/8” D
Support
Call Miele (800) 999-1360
Miele Website
20/20 Link
DA 6891 w/DAG 600 g 500 CFM
DA 6891 w/DAG 1000 g 1000 CFM
DAG 600 g 6” (150 mm)
DAG 1000 g 10” (254 mm)
8www.mieleusa.com
82020technologies.com
DA 6891 w/DAG600 Item DA6891+internal
DA 6891 w/DAG1000 Item DA6891+external
Page 2 of 12
STANDARD ACCESSORIES
Two Support Brackets for
One or Two Cutout(s) Instal-
lation
OPTIONAL ACCESSORIES
36” Downdraft Hood
Flush Installation
DAG 600
500 CFM Internal Blower
DAG 1000
1000 CFM External Blower
R2000
DUU 2900
Recirculation kit for use
with DAG 600
DKF18-900
Replacement OdorFree
charcoal lter
(Used with DUU 2900)
DUU 150
Recirculation kit for use with
DAG 600
DUU 151
Recirculation kit for use with
DAG 600
DKF22-900
Reducing collar limits air
ow to less than 300 CFM
with DAG 600
Replacement OdorFree charcoal
lter
(Used with DUU 150 and DUU 151)
Page 3 of 12
PRODUCT SPECIFICATIONS
36” Downdraft Hood
Flush Installation
Page 4 of 12
Loading...
+ 8 hidden pages