Product Dimensions
Downdraft Ventilation
DA6480
DA6490
E
Page 1 of 7
Shown with interior-mounted
DAG 500 vent motor
Location Codes
E - 120 Volt – 15 Amp 3 wire power supply
Hard wire connection to terminal
Notes
All electrical work should be performed by a
qualified electrician in strict accordance with
national regulations and local safety
regulations.
Installation, repairs and other work by
unqualified persons could be dangerous.
Ensure that power to the appliance is off
while installation or repair work is performed.
The ventilation system may only be used
with Miele DAG 500 or DAG 1000 blowers.
Drawing is not to scale - Specification Sheets OJS 032111
Downdraft Ventilation
DA6480
DA6490
Cabinet Preparation
Page 2 of 7
D - Feed the power cord
and control cable when
using an external blower
downwards or to the rear.
A-Cooktop overhang
B-Minimum Width
DA6480: 28” (711 mm)
DA6490: 34” (864 mm)
Exhaust air ducting using the DAG 500 internal
blower, installed on the front of the appliance [vent
duct 6” Ø (150 mm): A- to the left or right, Bdownwards, C- to the rear.
E- Using the DAG 1000 external blower, install
exhaust ducting to the rear [vent duct 10” Ø (254 mm)
Ensure clearances for front install.
Drawing is not to scale - Specification Sheets OJS 032111
Product Dimensions
Downdraft Ventilation
Page 3 of 7
DA6480
DA6490 Clearance Dimensions
Drawing is not to scale - Specification Sheets OJS 032111