Miele DA6290W User Manual

Product Dimensions Decorator Wall Hood DA6290W
Distance “S” is determined by the cooking surface
Page 1 of 2
Recirculation Vent
1 Air extraction mode 2 Recirculation mode
Location Codes
E - 110 Volt – 15 Amp 3 wire power supply connects through top or rear of chimney.
- Offset from duct center line by 2”
Notes
All installations must be done in accordance with local codes.
6” duct connects to blower system inside chimney.
4, 5 Installation area;
For recirculation mode only 5.
Wall/ceiling area respectively for vent hole and outlet installation.
Drawing is not to scale - Specification Sheets 010411
Product Dimensions Decorator Wall Hood DA6290W Drilling diagram
Page 2 of 2
Notes
Center unit over cooking surface
Distance “S” is determined by the cooking surface
(see hood instructions below for details)
Area behind mounting plates MUST be reinforced using a minimum of ½” plywood. Reinforcing material should be affixed to structural wall members
Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood:
Non-Miele CooktopsMiele Cooktops
24” (610 mm)Electric Cooktops
26” (660 mm)Electric Barbeques and Fryers
Multiburners Gas cooktops 43,00 BTU (12.6 KW) And no burner > 15,000 BTU (6KW)
30” (760 mm)All other gas cooktops
Drawing is not to scale - Specification Sheets 010411
30” (760 mm)26” (660 mm)
30” (760 mm)26” (660 mm)Single burner (Wok) 20,500 BTU (6 KW)
Loading...