Cleaning the casing................................................16
Grease filter and air intake panel......................................17
Changing the light bulbs ............................................19
After Sales Service
Installation instructions
Caring for the environment
Installation accessories
Plywood backing
Electrical data
Appliance dimensions
Installation
Read these Operating Instructions carefully before installing or
using the Ventilation System.
This appliance is designed to vent
This appliance is intended for
residential use only. Use the
appliance only for its intended
purpose. The manufacturer cannot
be held responsible for damages
caused by improper use of the
hood.
This appliance complies with current
safety requirements. Improper use
of the appliance can lead to
personal injury and material
damage.
READ AND SAVE THESE
INSTRUCTIONS
CAUTION
Use only for general ventilation.
Do not use to exhaust hazardous or
explosive materials and vapors.
~
cooking smoke and odors only.
Be certain your appliance is
~
properly installed and grounded by a
qualified technician.
To guarantee the electrical safety of this
appliance, continuity must exist
between the appliance and an effective
grounding system. It is imperative that
this basic safety requirement be met. If
there is any doubt, have the electrical
system of the house checked by a
qualified electrician. The manufacturer
can not be held responsible for
damages caused by the lack, or
inadequacy, of an effective grounding
system.
Before connecting the appliance to
~
the power supply make sure that the
voltage and frequency listed on the
data plate correspond with the
household electrical supply. This data
must correspond to prevent machine
damage. If in doubt consult a qualified
electrician.
Installation work and repairs should
~
only be performed by a qualified
technician in accordance with all
applicable codes and standards.
Repairs and other work by unqualified
persons could be dangerous and the
manufacturer will not be held
responsible.
3
IMPORTANT SAFETY INSTRUCTIONS
This equipment is not designed for
~
maritime use or for use in mobile
installations such as recreational
vehicles or aircraft. However, under
certain conditions it may be possible for
an installation in these applications.
Please contact the nearest Miele dealer
or the Miele Technical Service
Department with specific requirements.
Before servicing or cleaning the unit,
~
switch power off at the service panel
and lock the service disconnecting
means to prevent power from being
switched on accidentally. If the service
disconnecting means cannot be
locked, securely fasten a prominent
warning device, such as a tag, to the
service panel.
Before discarding an old appliance,
~
unplug it from the power supply and
remove the power cord and any doors
to prevent hazards.
Use
Do not allow children to play with or
~
operate the appliance or its controls.
Supervise its use by the elderly or
infirm.
Do not flambé or grill with an open
~
flame beneath the hood.
Flames could be drawn up into the
hood by the suction and the grease
filters may catch fire.
Never operate gas burners without
~
cookware. Turn the burner off when not
in use. Adjust the burner so that the
flames do not extend beneath the
cookware. Do not overheat the
cookware, e.g. when using a wok. The
hood can be damaged due to
excessive heat from the burners and
the cookware.
Do not use the hood without the
~
grease filters in place.
Clean the grease filters regularly.
~
Dirty filters are a fire hazard.
Do not use a steam cleaner to clean
~
the hood. Steam could penetrate
electrical components and cause a
short circuit.
Always turn on the hood when using
~
the cooktop to prevent damage from
condensation.
4
IMPORTANT SAFETY INSTRUCTIONS
, WARNING - TO REDUCE
THE RISK OF A COOKTOP
GREASE FIRE:
Never leave surface units
~
unattended at high settings. Boilovers
cause smoking and greasy spillovers
may ignite. Heat oils slowly on low or
medium settings.
Always turn the hood on when
~
cooking at high heat.
Clean ventilating fans frequently.
~
Grease should not be allowed to
accumulate on fan or filter.
Use proper pan size. Always use
~
cookware appropriate for the size of the
surface element.
, WARNING
TO REDUCE THE RISK OF INJURY
TO PERSONS IN THE EVENT OF A
RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING:
SMOTHER FLAMES with a close
~
fitting lid, cookie sheet, or metal tray
then turn off the burner.
BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE
DEPARTMENT.
NEVER PICK UP A FLAMING PAN
~
- You may be burned.
DO NOT USE WATER, including
~
wet dishcloths or towels - a violent
steam explosion will result.
Use a fire extinguisher
~
ONLY if:
– You have a Class ABC extinguisher,
and you know how to operate it.
– The fire is small and contained in the
area where it started.
–
The fire department is being called.
–
You can fight the fire with your back
to an exit.
5
IMPORTANT SAFETY INSTRUCTIONS
Installation
, WARNING
~
To reduce the risk of fire only use
metal ductwork.
Provided a larger distance is not
~
given by the manufacturer of the
cooktop, follow the recommended
minimum safety distances between a
cooktop and the bottom of the grease
filter of 30" (762 mm).
See "Appliance Dimensions" for more
information on optimum installation
heights.
If local building codes require a greater
safety distance, follow their
requirement.
If there is more than one appliance
beneath the hood and they have
different minimum safety distances
always select the greater distance.
Be careful not to damage hidden
~
electrical wiring or plumbing when
cutting or drilling into the wall or ceiling.
Do not use an extension cord to
~
connect the appliance to electricity.
Extension cords do not guarantee the
required safety of the appliance,
(e.g. danger of overheating).
Any fittings, sealant, or materials
~
used to install the ductwork must be
made of approved non-flammable
materials.
Never connect an exhaust hood to
~
an active chimney, dryer vent, vent flue,
or room ventilating ductwork. Seek
professional advice before connecting
an exhaust hood vent to an existing,
inactive chimney or vent flue.
Ducted fans must always be vented
~
outdoors.
Make sure that the airflow in the
~
room is sufficient for combustion and
exhausting of all non-electric heating
appliances (water heaters, gas
cooktops, gas ovens, etc.), otherwise
backdrafts may occur. Follow the
heating manufacturer’s guidelines and
safety standards or those published by
the National Fire Protection Association
(NFPA) or the American Society for
Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE).
If in doubt, consult an experienced
professional.
Do not install this hood over
~
cooktops burning solid fuel.
6
The ventilation hood works by airextraction. The air is drawn in and
cleaned by the grease filter and
directed outside.
The hood comes equipped with a
non-return flap. This flap automatically
closes when the hood is turned off so
that no exchange of outside air and
room air can occur. When the hood is
turned on, the air pressure of the
exhaust fan automatically opens the
flap blowing the inside air and cooking
odors outside.
Functional description
7
Guide to the hood
8
Guide to the hood
aChimney extension
bChimney
cCanopy
dControl panel
eOverhead lighting
fGrease filter
gAir intake panel
hLight button
This button dims the light or turns it on
and off.
The lighting can be used independently
of the fan.
iOn/Off button
jFan power selection
Four fan speed selection
kDelayed Shut Down
This button activates the Delayed Shut
Down feature. The fan can be set to
turn off automatically after either 5 or 15
minutes.
lGrease filter button
The indicator next the grease filter
button lights when the grease filter and
air intake panel need to be cleaned.
This button is also used:
–
to reset the grease filter timer after
cleaning the grease filter and air
intake panel (see "Cleaning and
Care").
–
to show how long the grease filter
has been in use (see "Operation /
Filter timers").
–
to change the number of hours
counted by the grease filter timer
(see "Operation / Reprogramming the
grease filter timer").
9
Operation
Turning on the fan
Press the On/Off button.
^
Selecting the power level
Use the "–/+" controls to select the
^
desired power level.
+ = increases the fan speed
– = decreases the fan speed
Levels "1" to "3" (green indicators) are
usually sufficient for normal cooking.
Intensive setting
Level "4" (yellow indicator) should be
used for a short period when frying or
cooking food with a strong aroma.
Automatically switching back the
intensive power level
The intensive level "4" can be
programmed to automatically switch
back to level "3" after 10 minutes.
Turn the fan and the lights off.
^
Press and hold the "Delay Shut down"
^
button for 10 secs. The first indicator
lights.
^ Press the following buttons one after
another,
– light
10
–
the "–" button, and
–
the light button again.
If the power level indicators "1" and "4"
flash the automatic switch back is not
activated.
To activate the automatic switch back
^
press the "+" button.
The power level indicators "1" and "4"
light continuously.
^ To save the setting press the "Delay
Shut Down" button.
If the procedure is not stored within
4 minutes of programming, the hood
will automatically default to the "old"
data.
Operation
Fan performance
The maximum air flow capacity is
625 cfm. Factors such as narrow duct
diameter and bends will affect this
value.
Level 1 operates at 40% capacity
Level 2 operates at 60% capacity
Level 3 operates at 80% capacity
Level 4 operates at 100% capacity
11
Operation
Delayed Shut Down
If odors or smoke remain in the kitchen
after cooking has been completed, the
Delayed Shut Down feature can be
selected to allow the hood to continue
running for either 5 or 15 minutes.
Press the Delayed Shut Down button
^
while the fan is still running.
Press once = 5 minute delay
(left indicator lights)
Press twice = 15 minute delay
(right indicator lights)
To cancel the Delayed Shut Down
feature press the button again.
Turning off the fan
Press the On/Off button to turn the
^
fan off.
The indicator goes out.
Automatic Safety Shut Off
The fan will turn off automatically 10
hours after the last button was activated.
The lighting however will remain on.
^ Press the On/Off button to turn the
fan back on again.
12
Operation
Turning the lighting on/off
The overhead lighting can be turned on
and off independently of the fan.
Press the light button briefly to turn
^
on the lighting.
The light button indicator illuminates.
Press the light button briefly again to
^
turn off the lighting.
The light button indicator will go out.
Dimming the lighting
The brightness of the lighting can be
adjusted.
While the lighting is turned on, press
^
the light button.
The lighting will dim until the button is
released.
If the button is pressed again, the
^
lighting will brighten until the button is
released.
If the button is pressed continuously,
the light will cycle between bright and
dark.
^ Press the light button again to turn off
the lighting.
13
Operation
Grease filter timer
A timer monitors the hours of fan
operation. The indicator for the grease
filter will light after 30 hours of
operation. The grease filter and air
intake panel must then be cleaned.
After the grease filter has been cleaned
and put in place, the grease filter timer
must be reset.
^ To do this, press the grease filter
button for about 3 seconds.
The indicator will go out.
Checking the grease filter timer
To check the percentage of time
already used:
Press the On/Off button to turn the
^
fan on.
^ Press the grease filter button.
The number of flashing "–/+" indicators
show the percentage of programmed
hours that have been used.
1 indicator = less than 25 %
2 indicators = less than 50 %
3 indicators = less than 75 %
4 indicators = less than 100 %
14
This information will remain stored in
memory in the event of a power failure.
Reprogramming the grease filter
timer
The grease filter timer is preset to 30
hours. This time can be lengthened or
shortened to 20, 30, 40 or 50 hours.
A time of 20 hours should be
–
programmed in kitchens with
frequent pan or deep frying.
A time of 20 hours should also be
–
programmed if the kitchen is only
used occasionally to prevent grease
which has accumulated over a long
period of time from hardening on the
filters, making cleaning more difficult.
Operation
The indicator for the grease filter and
one of the "–/+" indicators will flash.
The lit "–/+" indicator shows the
programmed time:
1st indicator from the left= 20 hours
2nd indicator from the left= 30 hours
3rd indicator from the left= 40 hours
4th indicator from the left= 50 hours
Use the "–/+" button to select the
^
desired time.
^ Press the On/Off button to turn off the
fan.
^
Press the Delayed Shut Down and
grease filter buttons at the same time.
^ Store the selection by pressing the
grease filter button.
If the procedure is not stored within
4 minutes of programming the hood
will automatically default to the "old"
data.
15
Cleaning and care
Before cleaning or servicing the
hood, disconnect it from the power
supply by either removing the fuse,
unplugging it from the outlet or
manually "tripping" the circuit
breaker.
Cleaning the casing
Never use abrasive cleaners,
,
scouring pads, steel wool or caustic
(oven) cleaners on the hood. They
will damage the surface.
^ The air intake panel, exterior surfaces
and controls can be cleaned with
warm water and liquid dish soap
applied with a soft sponge.
^ Wipe dry using a soft cloth.
Only use a slightly damp sponge
when cleaning the controls. Water
could penetrate into the electronics
and cause damage.
Stainless steel
Stainless steel surfaces can be cleaned
using a non-abrasive stainless steel
cleaner.
To help prevent resoiling, a conditioner
for stainless steel can also be used.
Apply sparingly with even pressure.
Stainless steel colored controls
These controls may become dis
colored or damaged if not cleaned
regularly.
Do not use a stainless steel cleaner
on these controls.
-
^
Glass surfaces can be cleaned using
glass cleaner.
Avoid:
–
cleaning agents containing soda,
acids or chlorides,
–
abrasive cleaning agents
e.g. powder or cream cleansers,
–
abrasive sponges, e.g. pot scourers
or sponges which have been
previously used with abrasive
cleaning agents,
–
limescale removers.
These will damage the surface.
16
Cleaning and care
Grease filter and air intake
panel
The reusable metal grease filter
removes solid particles from the vented
kitchen air (grease, dust, etc).
The grease filter and the air intake
panel should be cleaned every3-4
weeks or whenever the grease filter
indicator lights.
Keep the grease filter clean to
prevent a fire hazard.
Removing the air intake panel
To remove the air intake panel gently
^
pull out and downward, shifting the
lower part a bit to the right. Lift it out
of the latches.
Support the air intake panel so that it
does not fall onto the cooktop.
Removing the grease filter
^
To remove the grease filter, pull on
the lever. Support the grease filter so
that it does not fall onto the cooktop.
17
Cleaning and care
Cleaning the grease filters
By hand: use a scrub brush with a
^
solution of warm water and mild
detergent.
Do not use the pure detergent,
aggressive all purpose cleaners,
oven sprays or limescale removers.
They could destroy the filters.
In a dishwasher: place the filters
^
vertically in the lower basket, making
sure that the spray arm is not
blocked.
Use a hot temperature program, e.g.
"Heavy Soil" or "Pots and pans".
Use the recommended amount of
dishwasher detergent. Overuse could
destroy the filter.
Push the grease filter back in place.
^
Hook the air intake panel on the
^
latches and push a little to the left.
Push it toward the unit so that it clicks
in place.
Depending on the detergent,
cleaning the grease filter in a
dishwasher may cause permanent
discoloration of the filter surface.
Performance of the filter will not be
affected by this discoloration.
^
After cleaning, the filter can be
placed on a towel to air dry.
^
Clean the air intake panel according
to "Cleaning the casing".
^
While the filter and the air intake
panel are removed, clean any dirt or
grease from the interior casing to
prevent the risk of fire.
^ After returning the grease filter, press
the grease filter button for 3 seconds
to reset the timer.
The indicator light will go out.
^ If the grease filter and air intake
panel are cleaned before the grease
filter timer has reached its maximum,
the grease filter button should be
pressed for 6 seconds to reset the
counter to zero.
18
Changing the light bulbs
Before changing the light bulbs,
disconnect the hood from the power
supply by either removing the fuse,
unplugging it, or manually "tripping"
the circuit breaker.
When in use halogen bulbs become
extremely hot, and they can burn
your hands. Do not attempt to
change the bulbs until they have
had sufficient time to cool.
Do not touch the bulb surface.
Fingerprints or body oils deposited
on the bulb will decrease its life.
Please follow the bulb
manufacturer’s instructions.
Cleaning and care
Pull the old bulb out of its socket
^
using the enclosed lever. Replace it
with a new one. Be careful not to
drop the bulb on the cooktop.
Replacement bulbs may be ordered
from Miele’s Technical Service
Department.
See the phone numbers on the back
of this booklet.
19
After Sales Service
Repairs
In the event of a fault which you cannot
easily fix yourself, please contact the
Miele Technical Service Department.
When contacting the Technical
^
Service Department, please quote
the model and serial number of your
appliance.
These are shown on the data plate
which is visible when the grease filters
are removed.
MieleCare
MieleCare, our Extended Service
Contract program, gives you the
assurance of knowing that your
appliance investment is covered by
5 years of worry free ownership.
MieleCare is the only Extended Service
Contract in the industry that guarantees
repairs by a Miele Authorized Service
Provider using genuine Miele parts.
Only genuine Miele parts installed by
factory trained professionals can
guarantee the safety, reliability, and
longevity of your Miele appliance.
Please note that unless expressly
approved in writing by Miele’s Service
department, Extended Service
Contracts offered by other providers for
Miele products will not be recognized
by Miele. Our goal is to prevent
unauthorized (and untrained) service
personnel from working on your Miele
products, possibly doing further
damage to them, you and/or your
home.
20
To learn more about MieleCare
Extended Service Contracts, please
contact your appliance dealer or visit
us online at:
http://store.miele.com
Installation Instructions
22
Caring for the environment
Disposal of packing material
The cardboard box and packing
materials protect the appliance during
shipping. They have been designed to
be biodegradable and recyclable.
Please recycle.
To prevent suffocation of children,
ensure that any plastic wrappings,
bags, etc. are disposed of safely
and kept out of their reach.
Disposal of an old appliance
Old appliances may contain materials
that can be recycled. Please contact
your local recycling center about the
possibility of recycling these materials.
Before discarding an old hood,
unplug it from the outlet and cut off
its power cord to prevent hazards.
23
Installation accessories
24
a3 protective shields
prevent scratches to the chimney
during installation.
bUpper retaining plate secures the
chimney extension.
cMiddle retaining plate for
additional stability of the chimney.
d2 hose clips for securing the
ducting.
e1 reducing collar
for use with 5" (125 mm) exhaust
ducting.
Installation accessories
5 large headed screws 5 x 40 mm
for securing the retaining plates and the
canopy.
(S8 wall anchors included in the
packaging are not for use in USA /
CDN.)
2 screws5x60mmfor securing the
chimney.
Caution: During the installation
process, please be careful of sharp
edges that can cause harm.
6 screws 3.5 x 9.5 mm for securing the
canopy and filter housing
2 screw covers
1 lever for dismantling the chimney and
changing the light bulbs
Installation instruction sheet
25
Plywood backing
The majority of the weight of the
installed ventilation system will be
supported by the lower retaining
plate. It must be firmly attached to
the stud framing behind the drywall.
If studs are not available in the
required locations, a plywood
backing (min. ½" (13 mm) thick)
spanning at least two studs must be
installed. Failure to adequately
support the weight as stated may
result in the ventilation system falling
off the wall, causing personal injury
and property damage.
(If plywood backing is not needed,
proceed to the included installation
sheet.)
To install a plywood backing
Find the studs to the left and right of
^
the mounting location by tapping the
wall or using a stud finder.
Mark a vertical cutting line along the
^
center of each stud.
Be careful not to damage any wiring
or plumbing that may be located
behind the wall. Make sure that the
power supply to the area where this
installation is being performed has
been turned off at the breaker panel
before cutting into the wall.
^ Remove the drywall between the
cutting lines and replace it with
plywood of a matching thickness
(min. ½" (13 mm) thick). Tape the
joints and refinish the wall.
^ Proceed to the included installation
sheet to complete the installation.
^
Determine and mark the location of
the retaining plate for the canopy as
outlined on the installation sheet.
^
Make a cutting line 3" (76 mm) above
and 3" (76 mm) below the outline of
the retaining plate.
26
Electrical data
All electrical work should be
performed by a qualified electrician
in strict accordance with national
and local safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer
cannot be held responsible for
unauthorized work.
Ensure that power to the appliance
is OFF while installation or repair
work is performed.
Verify that the voltage, load and
^
circuit rating information found on the
data plate (located behind the
grease filters), match the household
electrical supply before installing the
hood.
^ Use only with rangehood
cord-connection kits that have been
investigated and found acceptable
for use with this model rangehood.
If there is any question concerning the
electrical connection of this appliance
to your power supply, please consult a
licensed electrician or call Miele’s
Technical Service Department.
U1-800-999-1360
V1-800-565-6435
WARNING:
THIS APPLIANCE MUST BE
GROUNDED
Grounding Instructions
This appliance must be grounded. In
the event of an electrical short circuit,
grounding reduces the risk of electric
shock by providing a path of least
resistance. This appliance is equipped
with a cord having a grounding wire
with a grounding plug. The plug must
be plugged into an outlet that is
properly installed and grounded.
WARNING - Improper grounding can
result in a risk of electric shock.
If there is any doubt, have the electrical
system of the house checked by a
qualified electrician. The manufacturer
cannot be held responsible for
damages caused by the lack, or
inadequacy, of an effective grounding
system.
Do not use an extension cord. If the
power supply cord is too short, have a
qualified electrician install an outlet
near the appliance.
Important
The hood comes equipped witha4ft
(1.2 m) power cord with a NEMA 5-15
molded plug for connection to a
120 VAC, 60 Hz, 15 A power outlet.
Maximum load ..............390W
Light.....................4x10W
Voltage .....................120V
Frequency ..................60Hz
Circuit rating..................15A
27
Appliance dimensions
28
Appliance dimensions
1) and 2)
Cut out area in wall or ceiling for
entrance of 6" (150 mm)
ductwork or 5" (125 mm) ductwork with
a reducing collar.
Do not install this exhaust hood over
cooktops burning solid fuel.
Provided a larger distance is not
given by the manufacturer of the
cooktop, follow the recommended
minimum safety distances between
a cooktop and the bottom of the
grease filter of 30" (762 mm).
If local building codes require a
greater safety distance, follow their
requirement.
Follow the safety distances
recommended by the cooktop
manufacturer in their installation and
operating instructions.
Distance between cooktop and
hood (S)
To observe the safety distance and
^
ensure an optimum function and use
of the hood, a distance of S=14(365 mm) between the cooktop and
the lower edge of the glass pane is
recommended.
If the hood is fitted flush to the
^
ceiling, the sum of
S+H+Workspace
should not exceed the room height.
Standard unit height H
37 7/8" - 51 7/8"
(960 - 1320 mm)
To fit the lower chimney section, the
distance between the top of the
chimney and the ceiling must be at
7
least
/8" (20 mm).
3
/8"
If there is more than one appliance
beneath the hood and they have
different minimum safety distances
always select the greater distance.
See "IMPORTANT SAFETY
INSTRUCTIONS" for further
information.
29
Installation
Installation instructions
See the enclosed installation
^
instruction sheet.
Please read the "Important Safety
^
Instructions" and Installation
instructions before installing this
hood.
Protective film
The casing is covered with a protective
film to prevent scratching during
transport.
^ Peel off the film before installing the
casing parts.
Dismantling
If the hood needs to be disassembled,
follow the instructions on the installation
sheet in the reverse order.
A lever is enclosed for easier removal
of the chimney extension.
^ After removing the screws from the
chimney, slide the lever between the
chimney and the chimney extension
and gently apply pressure to ease
the chimney from its hooks.
30
WARNING
,
Danger of toxic fumes.
Air extraction
Exhaust ducting and connections
The ducting should be as short and
–
straight as possible, and the number
of sharp bends should be minimized.
Gas cooking appliances release
carbon monoxide that can be
harmful or fatal if inhaled.
The exhaust gases extracted by
the hood should be vented
outside of the building only.
Do not terminate the exhaust
ducts in attics, garages,
crawlspaces, etc.
To reduce the risk of fire, only use
metal ductwork.
Please read and follow the
"IMPORTANT SAFETY
INSTRUCTIONS" to reduce the risk of
personal injury. Follow all local building
codes when installing the hood.
For most efficient air extraction, the
–
diameter of the ductwork should not
be less than 6" (150 mm). Use of flat
ducts also reduces the air extraction
efficiency.
Noise levels of the hood will increase
–
if flat ducts or round ducts of less
than 6" (150 mm) in diameter are
used.
– Use smooth or flexible pipes made
from approved non-flammable
materials for exhaust ducting.
– Where the ductwork is horizontal, it
must slope away from the hood at
1
least
/8" per foot (1 cm per meter) to
prevent condensation dripping into
the appliance.
– If the exhaust is ducted through an
outside wall, a Miele Telescopic Wall
Vent can be used.
31
Air extraction
If the exhaust is ducted into an inactive
flue, the air must be expelled parallel to
the flow direction of the flue.
Never connect an exhaust hood to
an active chimney, dryer vent, vent
flue, or room venting ductwork.
Seek professional advice before
connecting an exhaust hood vent to
an existing, inactive chimney or vent
flue.
Important!
If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature variations exist, it may
need to be insulated to reduce
condensation.
Condensate trap
optional accessory
In some cases, a condensate trap may
also be required to collect and
evaporate any condensation which may
occur. This optional accessory is
available for ducts 5" (125 mm) and
7
5
/8" (150 mm) in diameter.
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outlet. The arrow on the casing
shows the venting direction.
323334
35
Alteration rights reserved / 4607
For most the updated manual see the Miele web site.
M.-Nr. 06 713 760 / 04
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.