Type B, Applied PartDangerous voltage / shock hazard
Protective earth groundDuty Cycle (motor run time):
[ATTENTION: Refer to
This product is Listed by Underwriters
Laboratories, Inc. Representative samples
of this product have been evaluated by UL
and meet the applicable U.S. safety
507U
requirements.
This product has been evaluated
with respect to electrical shock, fire,
& mechanical hazards only, in accordance
with CAN/CSA C22.2, No. 601.1.
94XM
2
Regulatory Compliance Chart
94XM
MODEL: 304-017
MIDMARK
CORPORATION
(palletted units)
1 min
9 min
1 minute ON, 9 minutes OFF
to verify UL compliance for specific models]
This product has been evaluated with
respect to electric shock, fire, & mechanical hazards
only, in accordance with UL60601-1, IEC60601-1,
CAN/CSA C22.2, No. 601.1.
This component
by Underwriters Laboratories, Inc.
Representative samples of this component
have been evaluated by UL and meet the
applicable U.S. safety requirements.
This product is intended to be used as a chair / table to provide positioning and support of
patients during bariatric procedures conducted by qualified medical professionals.
Patient Positioning
The table is designed to accommodate the following examination positions:
• Prone
• SupineCaution
• Lateral SimsNever seat a patient on the back section of the table.
Doing so may cause table to tip.
Electrical Requirements
Caution
Most exposed metal parts of the table are electrically grounded.
When performing a cauterization or similar treatment, the patient must be
insulated from the metal portions of the table by nonconductive material.
Failure to do so could result in electric shock or burns to patient.
Electromagnetic Interference
Thistable is designed and built to minimize electromagnetic interference with other devices.
However, if interference is noticed between another device and this table, remove interfering
device from room and/or plug table into an isolated circuit.
Transportation / Storage Conditions
Ambient Temperature Range: .............................. -5°C to +38°C (+23°F to 100°F)
Relative Humidity .................................................10% to 90% (non-condensing)
Atmospheric Pressure.......................................... 500hPa to 1060hPa (0.49atm to 1.05atm)
Paper Roll Size (max.) ........................................... 24 in. wide x 6 in. diameter
(61 cm x 15.2 cm)
Warning
To avoid injury, do not put head or
extremities under the paper tear strap.
003-1456-99
To install the paper roll...
A. Install paper roll, onto dowel rod.
B. Insert one end of dowel rod into bracket.
C. Press button on other end of dowel rod,
then insert rod into other bracket.
Wash your upholstery weekly with a mild liquid soap and water mixture, rinse with clear water
and dry completely to remove disinfection cleaner build-up.
Disinfect your upholstery with a solution of standard bleach and water mixed 1 in 10 (10%) or
chlorine based cleaners. Follow this with a clear water rinse and thorough drying of material.
See current CDC Guideline for Disinfection & Sterilization in Healthcare Facilities.
To minimize damage caused by disinfectant cleaner residue build-up, do not allow
disinfectants to pool on the upholstery surface. Once the approved contact time has been
obtained, remove and dry excess liquid remaining on the surface.
Detailed care and maintenance instructions are included with your product. This
information is also available on www.midmark.com in the Technical library under the User
Information tab for your product.
Painted Metal / Plastic Surfaces
Clean the painted metal and plastic surfaces weekly using a clean soft cloth, and mild cleaner.
Periodic applications of common furniture wax will ease cleaning, and maintain the finished
luster of the surfaces.
Preventive Maintenance
Periodically inspect the following areas:
•Power cord should be free of cuts or other visible damage.
•All fasteners should be present and tightened securely.
•All mechanical functions should operate properly.
Have a qualified service technician inspect your table every six months.
Calling For Service
Note
Model / Serial Number information is required when calling for service.
Contact your Midmark Dealer, or log onto www.midmark.com to locate your nearest
service provider. To contact Midmark directly:
1-800-Midmark (1-800-643-6275) or 937-526-3662
8:00 am until 5:00 pm. Monday through Friday (EST)
SCOPE OF WARRANTY
Midmark Corporation (“Midmark”) warrants to the original retail purchaser that it will repair or replace
components of the domestic and international medical products manufactured by Midmark (except for
components not warranted under “Exclusions”) that are defective in material or workmanship under
normal use and service. Midmark’s obligation under this warranty is limited to the repair orreplacement, at Midmark’s option, of the applicable components. This limited warranty shall only apply to defects
that are reported to Midmark within the applicable warranty period and which, upon examination by
Midmark, prove to be defective. This warranty extends only to the first retail purchaser of a product and is
not transferable or assignable.
APPLICABLE WARRANTY PERIOD
The applicable warranty period, measured from the date of delivery to the original user, shall be one (1)
year for all warranted products and components.
(A) Ultrasonic cleaner products are guaranteed for a period of two (2) years after ship date when used in
accordance with manufacturer’s instructions.
(B) Replacement parts and accessories carry a ninety (90) day warranty.
OBTAINING WARRANTY SERVICE
Warranty service must be obtained through either Midmark or an authorized dealer in the Midmark
product line for which warranty service is requested. Midmark may be contacted for warranty service
inquiries or issues via email at www.midmark.com; by phone at 1-800-MIDMARK; by facsimile at 1-800365-8631; or by mail to Midmark Corporation, 60 Vista Drive, Versailles, Ohio 45380.
It is the retail purchaser’s obligation to arrange for delivery of a product to Midmark or one of its authorized dealers for warranty service, which delivery shall be at retail purchaser’s expense. It is also the retail
purchaser’s obligation to comply with the warranty service instructions provided either by Midmark or its
authorized dealer. The retail purchaser must provide Midmark with completed warranty registration
information within thirty (30) days after purchase in order to obtain the benefits of this warranty.
EXCLUSIONS
This warranty does not cover, and Midmark shall not be liable, for the following:
(1) defects, damage or other conditions caused, in whole or in part, by misuse, abuse, negligence,
alteration, accident, freight damage, tampering or failure to seek and obtain repair or replacement in a
timely manner;
(2) products which are not installed, used, and properly cleaned and maintained as required in the
Midmark “Installation” and/or “Installation/Operation Manual” for the applicable product;
(3) products considered to be of a consumable nature;
(4) accessories or parts not manufactured by Midmark;
(5) charges by anyone for adjustments, repairs, replacement parts, installation or other work performed
upon or in connection with such products which are not expressly authorized in writing in advance by
Midmark;
(6) costs and expenses of routine maintenance and cleaning; and
(7) representations and warranties made by any person or entity other than Midmark.
EXCLUSIVE REMEDY; CONSEQUENTIAL DAMAGES DISCLAIMER:
MIDMARK’S ONLY OBLIGATION UNDER THIS WARRANTY IS THE REPAIR OR REPLACEMENT OF
DEFECTIVE PARTS. MIDMARK SHALL NOT BE LIABLE FOR AND HEREBY DISCLAIMS ANY DIRECT,
SPECIAL, INDIRECT, INCIDENTAL, EXEMPLARY OR CONSEQUENTIAL DAMAGES OR DELAYS,
INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFITS OR INCOME, LOSS OF USE,
DOWNTIME, COVER AND EMPLOYEE OR INDEPENDENT CONTRACTOR WAGES, PAYMENTS AND
BENEFITS.
NO AUTHORIZATION
No person or firm is authorized to create or approve for Midmark any other obligation or liability in
connection with the products.
WARRANTY DISCLAIMER
THIS WARRANTY IS MIDMARK’S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED. MIDMARK MAKES NO IMPLIED WARRANTIES OF ANY KIND INCLUDING ANY
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR APARTICULAR PURPOSE.
THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS.
STATUTE OF LIMITATIONS
No action may be brought against Midmark for breach of this limited warranty, an implied warranty, if any,
or for any other claim arising out of or relating to the products, more than ninety (90) days following
expiration of the limited warranty period.