Midmark 110-3110-00 Operation Manual

DIGITAL VETERINARY SCALE
Operation Manual
MidMark Corporation
60 Vista Drive
Versailles, Ohio 45380
Phone: 1.800.MIDMARK
INTRODUCTION
TABLE OF CONTENTS
Thank you for purchasing our Digital Veterinary Scale. This manual will guide you through setup and operation of your scale. Please read it thoroughly before attempting to operate this scale and keep it handy for future reference.
DISCLAIMER
While every precaution has been taken in the preparation of this manual, the Seller assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from use of the information contained herein. All instructions and diagrams have been checked for accuracy and ease of application; however, success and safety in working with tools depend to a great extent upon the individual accuracy, skill and caution. For this reason, the Seller is not able to guarantee the result of any procedure contained herein. Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures. Persons engaging the procedures do so entirely at their own risk.
COPYRIGHT
All rights reserved. Reproduction or use, without expressed written permission, of editorial or pictorial content, in any manner, is prohibited. No patent liability is assumed with respect to the use of the information contained herein.
Midmark Product No. 110-3110-00
Serial Number_______________________ Date of Purchase ____________________ Purchased From_____________________
___________________________________ ___________________________________
RETAIN THIS INFORMATION FOR FUTURE USE
Introduction ………………………………….. 1
Specifications ………….………….………… 1
Installation………………………………….… 2
Indicator Functions …..……..…..…………. 3
Key Functions …………...………………….. 4
Operation ……………………………………. 5
Configuration ………………..………………. 6
Display Message …….…..………..……….. 8
Care and Maintenance….…..…………..….. 8
SPECIFICATIONS
Indicator: LCD, 6 Digit, Backlit
Indicator Dimensions:
Platform Dimensions:
Indicator Mount:
Zero: Established on power up routine
Power: 120 VAC 60Hz to 15 VDC 300
Tare: 100% of scale capacity
Temperature: 40 to 105°F (5°to 35°C)
Capacity and Division:
Keys:
Features: Low battery indicator, Power
Before using this instrument, read this manual and pay special attention to all "WARNING" symbols:
6.69" L x 1.57" D x 3.15” H (170 mm x 40 mm x 80 mm)
44" L x 22" W x 2”H (1118 mm x 559 mm x 51 mm)
Wall or Post Mount Post Height 36” (914.5 mm)
and maintained by auto-zero circuitry.
mA wall plug-in UL Listed Power Adapter (included) or 4 AA (1.5 VDC) Alkaline Cells (not included)
330 lb x 0.2 lb 150 kg x 0.1 kg
ON/OFF, UNIT, HOLD, TARE
saving selectable timing auto shut-off
PRECAUTIONS
IMPORTANT ELECTRICAL
WARNING
1
INSTALLATION
UNPACKING
Before beginning installation of your scale, make certain the instrument has been received in good condition. When removing the scale from its packing, inspect it for signs of damage, such as exterior dents and scratches. Keep the carton and packing material for return shipment if it should become necessary. It is the responsibility of the purchaser to file all claims for any damages or loss incurred during transit. Remove all items from the shipping carton to ensure all items are received and inspect for any signs of damage.
Carton Contents:
ScaleBase StainlessSteelPlatform RubberMat ScaleFeet RubberSpacers Indicator IndicatorCable MountingPole IndicatorBracket Hardware ACAdapter
Manual  
POWER
AC Adapter
To apply power to the scale using the supplied 15VDC, 300 mA power supply, insert the plug from the power supply cable into the power jack on the left side of the indicator, then plug power supply into proper electrical outlet.
Battery
To power scale using batteries, install 4 AA Alkaline cells in the battery compartment in back of indicator.
2
INSTALLATION, CONT.
SET-UP
Floor with Post Mounted Indicator
Indicator Pole Mount
With scale base upside down,
install scale foot at each corner of scale base.
Set post to align holes on mounting plate
to holes on scale base.
Attach post to scale base using four screws as shown.
Route indicator cable up through post.
Turn scale upside right and place on floor.
Route indicator cable through indicator bracket
and attach bracket to post using three screws.
Plug Indicator cable into bottom of indicator and
set indicator on bracket.
Attaching Foot to Scale Base Bottom View
Attaching Post to Scale Base Bottom View
3