Midas Consoles MIDAS XL42 User Manual

Page 1
XL42
OPERATORS MANUAL
Telex Communications (UK) Ltd.
Klark Teknik Building
Walter Nash Road
Kidderminster
Worcestershire
DY11 7HJ
Tel: +44 1562 741515
Fax: +44 1562 745371
Website: www.midasconsoles.com
XL42 Dual Channel Strip Operators Manual
DOC02-XL42 Issue B - December 2005
© Telex Communications (UK) Ltd.
In line with the company’s policy of continual improvement, specifications and
function may be subject to change without notice. E&OE.
Page 2
Page 3
IMPORTANT SAFETY INSTRUCTIONS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE
AVIS: RISQUE DE CHOC ELECTRIQUE. NE PAS OUVRIR
These symbols are internationally accepted symbols that warn of potential hazards with electrical products.
The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a drycloth.
7. Do not block any of the ventilation openings. Install in accordance with the manufacturers instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult anelectrician for replacement ofthe obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments / accessoriesspecified by the manufacturer.
12. Unplug this apparatus during lightning storms or whenunused for long periods of time.
13. Refer all servicing to qualified personnel. Servicing is required when the apparatus is damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Page 4
Page 5
Klark Teknik Group (UK) Plc, Klark Teknik Building, Walter Nash Road, Kidderminster. Worcs. DY11 7HJ. England Tel:+44 1562 741515 Fax:+44 1562 745371 www.midasconsoles.com www.klarkteknik.com
DECLARATION OF CONFORMITY
We,
Klark Teknik Group (UK) PLC
of, Klark Teknik Building, Walter Nash Road, Kidderminster, Worcestershire, DY11 7HJ
Declare that a sample of the following product:-
Product Type Number Product Description Nominal Voltage (s) Current Freq
XL42 Dual Channel Strip 230V/115V 70mA / 50/60Hz
140mA
to which this declaration refers, is in conformity with the following directives and/or standards:-
Directive(s) Test Standard(s)
89/336/EEC Electromagnetic Compatibility Directive amended by 92/31/EEC & 93/68/EEC 73/23/EEC Low Voltage Directive amended by 93/68/EEC Generic Emissions Standard EN55013:1990 Generic Immunity Standard EN50082:1992 Electrical Safety UL6500-03
Signed:............................
Name: Simon Harrison
Date: 7th May 2004
(Pending at time of publication)
E60065-03
(Pending at time of publication)
EN60065:2002
(Pending at time of publication)
Authority: Research & Development Director, Klark Teknik Group (UK) PLC
Attention! Where applicable, the attention of the specifier, purchaser, installer or user is drawn to special limitations of use which must be observed when these products are taken into service to maintain compliance with the above directives. Details of these special measures and limitations to use are available on request and are available in product manuals.
A Subsidiary of Telex communications, Inc.
Page 6
Page 7
Contents
Thank you for using a Midas XL42 dual channel creative equaliser. The XL42 has been developed to meet the needs of demanding live sound engineers and meets the quality of build and performance that you would expect from a Midas product.
The XL42 is backed up by the standard Midas Three Year Warranty.
Contents
Please take the time to complete and return the registration card. spend a little time reading through this operators' manual, as this will allow you to obtain the best results from your XL42 with a minimum of effort.
Finally, enjoy your new Midas XL42!
In view of this flexibility, we hope that you will
Contents
Introduction
Before You Start
Installation Precautions 2 Voltage Selection and Power Connection 2 Safety Warning 2 Attention! Cables 2 Electric Fields 2
After You Have Unpacked the Unit
Front Panel
Input section 6 EQ section 7 Output section 8
Rear Panel
1
2
3
5
9
System Connection
Auto-mute Operation
Daisy Chain Operation
Technical Specification
13
14
15
17
XL42 Operators Manual - Page i
Page 8
Contents
Contents
XL42 Operators Manual - Page ii
Page 9
Introduction
The Midas XL42 is a 1U rack mounting, dual channel creative equaliser incorporating the XL4 four-band
parametric equalisation and XL4 mic/line pre-amplifiers with +48V phantom power.
Each channel has input gain, output level and pan rotary controls, 10-segment LED metering plus a switchable
insert send and return point. The XL42 also features Automute scene control from the Automute masters of XL
consoles, which are enabled by DIP switches on the rear of the unit.
The purpose of this unit is threefold:
1. To improve the audio quality of an inferior console by adding a Midas mic pre-amp and EQ.
2. To create custom mixing consoles through the ability to daisy chain multiple units. When linked together, the combined outputs will sum, producing discrete L&R channels.
3. If a production requires, for example, 10 channels more than the input capacity of the master console, five XL42s can be fitted in a standard rack together with any required dynamic processing, which can be inserted via the XL42's insert points; thus creating a custom 10 into 2 mixer via the output daisy chain feature. The resulting L and R outputs may then be routed to the master console via any convenient point, such as, a pair of aux returns, group inputs, matrix inputs etc.
As a stand-alone unit, the XL42 is ideally suited to applications requiring a high quality front end, such as stereo recording etc.
XL42 Operators Manual - Page 1
Page 10
Before You StartBefore You Start
Installation Precautions
Do not install this unit in a location subjected to excessive heat, dust or mechanical vibration. Allow for adequate ventilation around the unit, making sure the unit's vents are not obstructed. To avoid excessive heating of the unit, avoid mounting the unit directly above power amplifiers or other devices that radiate significant amounts of heat. Where necessary, use fan-cooled racks.
Voltage Selection and Power Connection
Mains power to the XL42 is supplied by means of a standard fused IEC power socket. The XL42 is designed to operate at nominal mains voltages of 115V and 230V AC at either 50 or 60 Hz, however, upon first use (and whenever the mains supply is changed) the input voltage selector on the rear of the unit must be set to reflect the local power supply. This information is also printed on the rear of the unit, below the mains inlet socket.
This device must be earthed and must use an approved mains fuse. Before connecting to the mains supply, ensure the fuse fitted is the correct type and rating as indicated on the rear panel (adjacent to fuse holder) and that the correct mains supply voltage is selected.
Safety Warning
To completely disconnect this equipment from the AC mains, set the power switch to the off position. The power switch shall remain readily operable.
Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the equipment.
For safety reasons the earth lead for this unit should never be disconnected. In the event of ground loop problems, under no circumstances must the mains earth be removed. Instead, disconnect the signal screen at one end of the connecting cables. Please note that this can only be done when the unit is being used within a balanced system.
To prevent shock or fire hazard, do not expose the unit to rain or moisture. To avoid electrical shock do not remove covers. Refer servicing to qualified personnel only.
Attention! Cables
The inputs and outputs are balanced on conventionally wired XLRs (pin 1 screen, pin 2 hot and pin 3 cold). This product should only be used with high quality, screened twisted pair audio cables, terminated with metal-bodied 3-pin XLR connectors. Any other cable type or configuration for the audio signals may result in degraded performance due to electromagnetic interference.
Note:
The +48V phantom power can only be used with balanced cables.
Electric Fields
Should this product be used in an electromagnetic field that is amplitude modulated by an audio frequency signal (20Hz to 20kHz), the signal to noise ratio may be degraded. Degradation of up to 60dB at a frequency corresponding to the modulation signal may be experienced under extreme conditions (3V/m, 90% modulation).
No permanent damage or degradation of performance will be caused by these conditions.
XL42 Operators Manual - Page 2
Page 11
After You Have Unpacked the UnitAfter You Have Unpacked the Unit
Before unpacking the XL42, check packaging for signs of damage, as this could be an indication of damage to the unit inside.
After unpacking the XL42, check the unit for signs of damage to the casing. Damage to consignments must usually be reported to the courier within 24 hours in order for a claim to be made.
Please retain the packaging for your XL42, as it will prove useful if you need to transport the unit.
Please also retain the XL42's Operators Manual (this document) and any other associated documentation.
XL42 Operators Manual - Page 3
Page 12
After You Have Unpacked the UnitAfter You Have Unpacked the Unit
XL42 Operators Manual - Page 4
Page 13
Front PanelFront Panel
The XL42 is a highly featured 1U 19” rackmount, dual channel strip. The unit is split into two identical channel strips, each with identical functionality but having independent inputs and outputs.
Power On/Off switch: Conventional latching type switch, which is on when in its fully in position and off when fully out. The action of the switch is firm but does not require excessive force, which may damage the unit. A red LED, to the left of the power switch, illuminates to indicate that the XL42 is receiving mains power.
Output section
EQ section
Input section
XL42 Operators Manual - Page 5
Page 14
Input section
mic/line gain control knob: Gives a continuously
variable input gain control depending upon the input selected, where:
Mic: +15dB to +70dB gain Mic (PAD enabled): -10dB to +45dB
Front PanelFront Panel
Ø switch: Phase switch inverts the input signal by applying a 180° phase shift.
PAD switch: line/padThe switch provides 25dB of attenuation to the input signal and allows the connection of high output microphones or line level signals. If using the XL42's optional transformer­coupled input, the pad greatly reduces the risk of saturation at very low frequencies.
+48 switch: Phantom power +48V switch allows connection of devices that require phantom power, such as, condenser microphones, direct inject (DI) boxes etc.
XL42 Operators Manual - Page 6
Page 15
Front PanelFront Panel
EQ section
The bass, lo-mid, hi-mid and treble bands use dual concentric rotary controls. The outside ring controls the band cut and boost in the range -15dB to +15dB. The inner ring of the dial controls the bandwidth of the filter in the range 0.1 to 2 octaves (with a centre detent at 0.5 octave).
bass dual concentric rotary control knob:
gain/attenuation adjustment is via inner control knob. Bass bandwidth is adjusted using the outer control ring, enabled via switch (immediately below).
freq (lo-cut) control knob:
Lo-cut filter control selects the HPF frequency and is continuously variable from 20Hz to 400Hz. Enabled by
lo-cut
the switch.
Bass band
bell
lo-mid dual concentric rotary control knob: Lo-mid band
gain/attenuation adjustment is via inner control knob. Lo-mid bandwidth is adjusted using outer control ring.
freq (lo-mid) control knob: Lo-mid control
selects frequency at which the lo-mid equaliser band acts and is continuously variable from 100Hz to 2KHz.
treble dual concentric rotary control knob:
gain/attenuation adjustment is via inner control knob. Treble bandwidth is adjusted using outer control ring, activated by
bell
switch (immediately
below).
hi-mid dual concentric rotary control knob: Hi-mid
band gain/attenuation adjustment is via inner control knob. Hi-mid bandwidth is adjusted using outer control ring.
Treble band
lo-cut switch:
Conventional latching switch that enables lo-cut filter when switch is on, that is, in its fully in position.
freq (bass) control:
Selects frequency at which the bass equaliser band acts; continuously variable from 20Hz to 400Hz.
eq switch:
Enables/disables equaliser in the signal path.
freq (hi-mid) control:
Selects frequency at which the hi-mid equaliser band acts; continuously variable from 400Hz to 8kHz.
bell (bass) switch: Conventional latching switch enables/disables parametric EQ for the bass band. When switch is in fully in position, equaliser band will work in full parametric mode. Otherwise, equaliser band acts like a traditional MIDAS shelving response EQ.
XL42 Operators Manual - Page 7
freq (treble) control:
Selects frequency at which the treble equaliser band acts; continuously variable from 1KHz to 20KHz.
bell (treble) switch: Conventional latching switch enables/disables parametric EQ for the treble band. When switch is in fully in position, equaliser band will work in full parametric mode. Otherwise equaliser band acts like a traditional MIDAS shelving response EQ.
Page 16
Output section
Front PanelFront Panel
level/pan dual concentric rotary control knob:
Pan control places the input within a stereo (left/right) mix and has a constant power law such that, at its centre position, each output is attenuated by 3dB. Pan control is enabled by
PAN PAN
the switch (immediately below) and is adjusted using the outer control ring. With switch off, the XL42 is essentially two independent channel strips. With switch on, the output signal from each input strip is distributed between the two outputs.
The output level, adjust by the inner control knob, controls the output level in the range ­(infinity) to +10dB.
Adjusts pan or output level.
PAN
Output peak level meter: Monitors
the level of the channel. By default, this is post-output level and pan, although it may be internally set to be pre-level pan and insert.
¥
INS switch:
circuitry is patched into the audio signal path. When the switch enabled (on, fully in position) then the insert jacks are patched into the audio signal path.
Note:
internally using jumpers to be pre- or post- EQ. The factory default setting is Pre-EQ.
Selects whether the insert
the insert point can be configured
PAN switch: level/pan
Enables the pan control on the
dual concentric rotary control knob.
XL42 Operators Manual - Page 8
MUTE switch: Mutes the channel outputs. Mute may
also be controlled via the Automute link selected via the "REMOTE CONTROL AUTOMUTE ASSIGNS" DIP switches on the rear panel
Page 17
Rear PanelRear Panel
The XL42 rear panel houses both the input and output sockets as well as the insert points, remote control and Automute sockets, and power inlet and selector.
PUSH
PUSH
PUSH
PUSH
1995
LEFT
INSERTION POINTS
RIGHT
LEFT INPUT
LEFT LINK INPUT
LEFT OUTPUT
RIGHT INPUT
RIGHT LINK INPUT
RIGHT OUTPUT
SEND
RETURN
SEND
RETURN
Left and right inputs
Left and right link inputs
Left and right outputs
Left and right insertion points
AUTOMUTE INPUT
TO REDUCE THE RISK OF FIRE, REPLACE FUSE WITH THE SAME TYPE AND RATING
NRTL/C
WARNING
REMPLACER PAR
UN FUSIBLE DE
REMOTE CONTROL
DO NOT EXPOSE
THIS APPLIANCE TO
CAUTION
ATTENTION RISQUE
MEME TYPE
AUTOMUTE ASSIGNS
SUPPLY
RAIN OR MOiSTURE
THIS
EQUIPMENT
DE CHOC NE
PAS ENLEVER
VOLTAGE
230
115 / 230V~ 50-60Hz 40W
MUST BE
EARTHED
5X20mm
FUSE
115V T315mAL250V
LEFT
Left and right remote control Automute assigns
RIGHT
Automute input and link
AUTOMUTE LINK
Supply voltage selector switch
IEC Power Inlet. Your XL42 should come complete with the correct IEC mains lead for the country in which it was intended for sale. If replacing the mains lead, replace with a recommended part and ensure that the fuse is of the correct type.
The XL42 must be earthed.
230V T160mAL250V
XL42 Operators Manual - Page 9
Page 18
Rear PanelRear Panel
Left and right link inputs: When used in a daisy chain, the link input is summed with the output from the XL42's input channels to the output so that the daisy chain may continue. A much larger console can be created by adding extra XL42s using the output from the last XL42 in the chain as the master output.
Input impedances: 20kOhm Balanced Maximum input level: +21dBu
The Left and Right link inputs may be configured using internal jumpers to sum with the channel input Pre­or Post- Output Level, Pan and Mute. The factory default setting is post Output Level, Pan and Mute.
Left and right inputs: Balanced XLR input to the channel strip from microphones, DI boxes, line etc.
Input impedances: Mic: 2kOhm Balanced
Maximum input level: Mic: +6dBu
Mic (with PAD): 3kOhm Balanced
Mic (with PAD): +31dBu
PUSH
PUSH
PUSH
PUSH
LEFT INPUTRIGHT INPUT LEFT LINK INPUTRIGHT LINK INPUT LEFT OUTPUTRIGHT OUTPUT
Left / Right Output: Balanced XLR output from the channel strip.
The output signal will be a combination of the link input plus the output from the XL42's input channels. If pan is selected on either of the inputs, the outputs will be a stereo combination of the input channels plus the link input. If pan is disabled on the channels, the output will be a combination of the input channel and the link input only.
Please note that if one input channel has pan enabled and one does not, the channel with pan enabled obeys the pan law of the pan pot. However, no signal is introduced into the other output. Only when both channel pan switches are enabled does the unit enter full stereo mode, that is, either output can be a combination of either input.
Maximum output level: +21dBu
The Left and Right Outputs may be internally configured using jumpers to be pin 2 or pin 3 hot. Factory default setting is pin 2 hot.
XL42 Operators Manual - Page 10
Page 19
Rear PanelRear Panel
Supply voltage selector switch:
The supply voltage is switchable between 115VAC and 230VAC, and should be set to the mains power supply available in the country in which the unit is to be used.
Caution! The supply voltage selector switch must be set BEFORE plugging the unit into the mains. UNDER NO CIRCUMSTANCES should the switch be changed whilst the unit is plugged in.
Remote Control Automute Assigns: The 9-pin plug for the
Automute system allows up to 8 Automute channels. The input channels of the XL42 can be set to mute on one of these 8 Automute channels by switching on the corresponding channel number on the DIP switch for the XL42's input channels.
AUTOMUTE INPUT
WARNING
DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOiSTURE
SUPPLY VOLTAGE
230
115 / 230V~ 50-60Hz 40W
AUTOMUTE LINK
REMOTE CONTROL
AUTOMUTE ASSIGNS
RIGHT
NRTL/C
LEFT
1995
INSERTION POINTS
RIGHT
RETURN RETURNSEND SEND
LEFT
Automute link/Automute input: Automute link socket can be used to extend the Automute connection to other XL42s in the daisy chain. Automute input should be wired according to diagram below.
12345
6789
54321
9876
Pin 1 Automute 1 Pin 2 Automute 2 Pin 3 Automute 3 Pin 4 Automute 4 Pin 5 Automute 5 Pin 6 Automute 6 Pin 7 Automute 7 Pin 8 Automute 8 Pin 9 Common
Left and right insertion points: Insert points can be used to add additional processing into the signal path, for example, Dynamics Processors, Graphic EQ, Effects, etc.
Input impedance: 20kOhm Balanced Maximum input level: +21dBu
The insert send and return are on independent balanced Bantam Jacks.
The insert point can be configured internally using jumpers to be pre- or post- EQ. The factory default setting is Pre-EQ.
XL42 Operators Manual - Page 11
Page 20
Rear PanelRear Panel
XL42 Operators Manual - Page 12
Page 21
System ConnectionSystem Connection
The XL42 is a versatile expansion to any system, or a complete system on its own.
You can use it:
replacement for an inferior mic pre-amp
As a
!
Plug the microphone or DI box into the XL42 and the output into the line input of your console. You can also use the XL42 EQ and bypass your console's EQ. Set PAN to off for mono operation or on for stereo operation.
better EQ
As a section for your console.
!
Plug the XL42 into the insert point of your console (Desk Send to XL42 Input and XL42 Output to Desk Return). Set the switch on the XL42 to the in position in for a line level signal.
As an to your console.
!
Connect your XL42s in a outputs from the last XL42 into a stereo channel ( on your console or into a stereo/effects return.
PAD
expansion
daisy chain configuration. Connect
or two mono channels)
.
As a high quality
!
Plug your microphones, such as a stereo condenser pair for recording, into the XL42 and the outputs into a DAT, CD or hard disk recorder.
The XL42 is the perfect companion for any system and could even be used for computer audio or drum sub-mixing where a high quality pre-amp and EQ is required.
pre-amp and EQ
.
XL42 Operators Manual - Page 13
Page 22
Auto-Mute OperationAuto-Mute Operation
The XL42 can be used within an Automute system. The standard 9-pin plug can control up to eight independent mono channels, each of which can be addressed by the XL42.
To assign an Automute address for each channel, the REMOTE CONTROL AUTOMUTE ASSIGNS should be turned on for the desired Automute address, that is, LEFT ASSIGN 2 would make the left-hand channel of the XL42 mute on channel 2 of the Automute system.
AUTOMUTE INPUT
NRTL/C
REMOTE CONTROL
AUTOMUTE ASSIGNS
AUTOMUTE LINK
Each channel may be assigned to more than one Automute channel by switching each of the required DIP switches.
The Automute plugs are wired as follows:
12345
6789
54321
RIGHT LEFT
Pin 1 Automute 1 Pin 2 Automute 2 Pin 3 Automute 3 Pin 4 Automute 4 Pin 5 Automute 5 Pin 6 Automute 6 Pin 7 Automute 7 Pin 8 Automute 8 Pin 9 Common
9876
The XL42 Automute system is compatible with all MIDAS XL series consoles, hence the XL42 is an ideal expansion to an XL series console when extra channels are required.
XL42 Operators Manual - Page 14
Page 23
Daisy-Chain OperationDaisy-Chain Operation
A number of XL42s can be connected in a daisy chain configuration to form a larger console or to expand an existing console. (32 channels of XL quality EQ and mic pre-'s will fit into a 16U.)
Inputs
Automute input
1 and 2
TO REDUCE THE RISK OF FIRE, REPLACE FUSE WITH THE SAME TYPE AND RATING
REMPLACER PAR UN FUSIBLE DE MEME TYPE ATTENTION RISQUE DE CHOC NE PAS ENLEVER
FUSE 5X20mm 115V T315mAL250V 230V T160mAL250V
TO REDUCE THE RISK OF FIRE, REPLACE FUSE WITH THE SAME TYPE AND RATING
REMPLACER PAR UN FUSIBLE DE MEME TYPE ATTENTION RISQUE DE CHOC NE PAS ENLEVER
FUSE 5X20mm 115V T315mAL250V 230V T160mAL250V
TO REDUCE THE RISK OF FIRE, REPLACE FUSE WITH THE SAME TYPE AND RATING
REMPLACER PAR UN FUSIBLE DE MEME TYPE ATTENTION RISQUE DE CHOC NE PAS ENLEVER
FUSE 5X20mm 115V T315mAL250V 230V T160mAL250V
TO REDUCE THE RISK OF FIRE, REPLACE FUSE WITH THE SAME TYPE AND RATING
REMPLACER PAR UN FUSIBLE DE MEME TYPE ATTENTION RISQUE DE CHOC NE PAS ENLEVER
FUSE 5X20mm 115V T315mAL250V 230V T160mAL250V
WARNING DO NOT EXPOSE THIS APPLIANCE TO
CAUTION
RAIN OR MOiSTURE
THIS EQUIPMENT MUST BE EARTHED
115 / 230V~ 50-60Hz 40W
WARNING DO NOT EXPOSE THIS APPLIANCE TO
CAUTION
RAIN OR MOiSTURE
THIS EQUIPMENT MUST BE EARTHED
115 / 230V~ 50-60Hz 40W
WARNING DO NOT EXPOSE THIS APPLIANCE TO
CAUTION
RAIN OR MOiSTURE
THIS EQUIPMENT MUST BE EARTHED
115 / 230V~ 50-60Hz 40W
WARNING DO NOT EXPOSE THIS APPLIANCE TO
CAUTION
RAIN OR MOiSTURE
THIS EQUIPMENT MUST BE EARTHED
115 / 230V~ 50-60Hz 40W
SUPPLY VOLTAGE
230
SUPPLY VOLTAGE
230
SUPPLY VOLTAGE
230
SUPPLY VOLTAGE
230
AUTOMUTE INPUT
AUTOMUTE LINK
AUTOMUTE INPUT
AUTOMUTE LINK
AUTOMUTE INPUT
AUTOMUTE LINK
AUTOMUTE INPUT
AUTOMUTE LINK
NRTL/C
REMOTE CONTROL
AUTOMUTE ASSIGNS
RIGHT
NRTL/C
REMOTE CONTROL
AUTOMUTE ASSIGNS
RIGHT
NRTL/C
REMOTE CONTROL
AUTOMUTE ASSIGNS
RIGHT
NRTL/C
REMOTE CONTROL
AUTOMUTE ASSIGNS
RIGHT
LEFT
LEFT
LEFT
LEFT
1995
INSERTION POINTS
RIGHT
LEFT
RETURN RETURNSEND SEND
1995
INSERTION POINTS
RIGHT
LEFT
RETURN RETURNSEND SEND
1995
INSERTION POINTS
RIGHT
LEFT
RETURN RETURNSEND SEND
1995
INSERTION POINTS
RIGHT
LEFT
RETURN RETURNSEND SEND
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
“Master” outputs - to
mixer, amplifer or
recording device
PUSH
PUSH
PUSH
PUSH
Inputs
PUSH
LEFT INPUTRIGHT INPUT LEFT LINK INPUTRIGHT LINK INPUT LEFT OUTPUTRIGHT OUTPUT
3 and 4
Inputs
PUSH
LEFT INPUTRIGHT INPUT LEFT LINK INPUTRIGHT LINK INPUT LEFT OUTPUTRIGHT OUTPUT
5 and 6
Inputs
PUSH
LEFT INPUTRIGHT INPUT LEFT LINK INPUTRIGHT LINK INPUT LEFT OUTPUTRIGHT OUTPUT
PUSH
LEFT INPUTRIGHT INPUT LEFT LINK INPUTRIGHT LINK INPUT LEFT OUTPUTRIGHT OUTPUT
7 and 8
As shown in the diagram above, each channel has its own input plus the output from the previous XL42 so that at the last point of the chain, the output is a combination of each input.
Depending on the use of each channel PAN, this may be a stereo image or all the left-hand channels grouped and all the right-hand channels grouped.
Optionally, you may wish to use the Automute feature. Here the output from the master console (any MIDAS XL series) is inserted at the top of the chain and linked into each unit.
XL42 Operators Manual - Page 15
Page 24
Daisy-Chain OperationDaisy-Chain Operation
XL42 Operators Manual - Page 16
Page 25
Technical SpecificationTechnical Specification
+25
+35
width
1
0.3 +15
mic/line gain
2
0.1
+/-
TO REDUCE THE RISK OF FIRE, REPLACE FUSE WITH THE SAME TYPE AND RATING
REMPLACER PAR UN FUSIBLE DE
MEME TYPE ATTENTION RISQUE DE CHOC NE PAS ENLEVER
FUSE 5X20mm 115V T315mAL250V 230V T160mAL250V
60 160
20
+70
/
+48PAD
O
lo-cut
phaseline/pad
0
6
6
6
+15-15
400
freq
bass
300
60 160
20
freq
1k
100
400
bell
freq
WARNING DO NOT EXPOSE THIS APPLIANCE TO
CAUTION
RAIN OR MOiSTURE
THIS EQUIPMENT MUST BE EARTHED
115 / 230V~ 50-60Hz 40W
2k
lo-mid
eq
230
0
+15-15
1k 3k
400
SUPPLY VOLTAGE
6
freq
6
-15
hi-mid
8k
AUTOMUTE INPUT
AUTOMUTE LINK
0
6
+15
3k 8k
1k
freq
0
6
6
+15-15
treble
20k
bell
0
+10
0
0
level/pan
MUTE
INS PA N
level pan
NRTL/C
REMOTE CONTROL
AUTOMUTE ASSIGNS
RIGHT
+15
+25
+35
+70
/
+48PAD
O
phaseline/pad
1995
INSERTION POINTS
60 160
20
lo-cut
LEFT
+12
+9 +6 +3
0
+15
-3
mic/line gain level/pan
-6
-9
-12
RIGHT
LEFT
RETURN RETURNSEND SEND
0
0
0
+15
3k 8k
1k
PUSH
0
6
6
6
+15-15
treble
20k
bell
freq
6
+15-15
400
freq
bass
300
60 160
100
20
400
freq
bell
freq
1k
lo-mid
2k
6
+15-15
-15
hi-mid
1k 3k
400
8k
eq
freq
PUSH
6
6
6
Input Impedance
Mic 2kOhm Balanced Mic + Pad 3k Balanced Link & Insert 20k Balanced
Ohm
Ohm
Input Gain (all controls at 0dB)
Mic Continuously variable from +15dB to +70dB Mic + Pad Continuously variable from -10dB to +45dB Link & Insert 0dB
Maximum Input Level
Mic +6dBu Mic + Pad +31dBu Link & Insert +21dBu
0
0
INS PA N
level pan
MUTE
+15
0
+12
+9 +6 +3
0
-12
PUSH
XL42
-3
-6
-9
ON
PUSH
LEFT INPUTRIGHT INPUT LEFT LINK INPUTRIGHT LINK INPUT LEFT OUTPUTRIGHT OUTPUT
+10
CMR at 1kHz
Mic (gain + 60dB) >70dB Mic + Pad (gain +35dB) >50dB Link & Insert >60dB
Frequency Response (20Hz to 20kHz)
Any input +0dB to -1dB
Noise (20Hz to 20kHz)
Mic EIN ref. 150 (gain + 60dB) -129dBu Transformer Mic Input EIN ref. 150 (gain + 60dB) -127dBu
Ohm
Ohm
System Noise at 0dB (one channel only) -88dBu
System Noise (20 to 20kHz)
Summing Noise (12 channels routed with faders down) -83dB Line to Mix Noise (12 channels routed at 0dB, pan centre) -81dB Summing Noise (48 channels routed with faders down) -81dB Line to Mix Noise (48 channels routed at 0dB, pan centre) -75dB
Distortion at 1kHz
Mic (+ 40dB gain, 0dBu output) <0.03% Link (0dBu) <0.03%
Output Impedance
All Outputs 50 Balanced Source to drive >600
Ohm Ohm
Maximum Output Level
All Outputs 50 Balanced Source to drive >600
Ohm Ohm
into >600 Ohm +21dBu
XL42 Operators Manual - Page 17
Page 26
Technical SpecificationTechnical Specification
Metering
Type 10 Segment LED Bargraph - Peak Reading
Equaliser
Hi pass slope 12dB/Oct Hi pass frequency Continuously variable -3dB point from 10Hz to 400Hz
Treble Gain Continuously variable +15dB to -15dB
Treble Shelving Freq. Continuously variable - 3dB point from 1kHz to 20kHz Treble Bell Freq. Continuously variable centre from 1kHz to 20kHz Treble Bell Bandwidth Continuously variable 0.1 Oct. to 2 Oct
Hi Mid Gain Continuously variable +15dB to -15dB
Hi Mid Freq. Continuously variable centre from 400Hz to 8kHz Hi Mid Bandwidth Continuously variable 0.1 Oct. to 2 Oct.
Lo Mid Gain Continuously variable +15dB to -15dB
Lo Mid Freq. Continuously variable centre from 100Hz to 2kHz Lo Mid Bandwidth Continuously variable 0.1 Oct. to 2 Oct
Bass Gain Continuously variable +15dB to -15dB
Bass Shelving Freq. Continuously variable - 3dB point from 20Hz to 400Hz Bass Bell Freq. Continuously variable centre from 20Hz to 400Hz Bass Bell Bandwidth Continuously variable 0.1 Oct. to 2 Oct
Automute System
Channel Quantity 8 Mute ON Voltage +3 to +20V Mute Off Voltage -20 to +2V Mute Line Load >500kOhm
Centre detent = 0dB
Centre detent = 0.5 Oct
Centre detent = 0dB
Centre detent = 0.5 Oct
Centre detent = 0dB
Centre detent = 0.5 Oct
Centre detent = 0dB
Centre detent = 0.5 Oct
Power
Nominal Mains Voltage 115V/230V Mains Consumption 40W Phantom Voltage Supply +48V ± 5% Maximum Phantom Current <10mA
Dimensions
Width 482mm (19 inches) Depth 250mm (10 inches) Height 44mm (1.75 inches)
Weight
Nett 3kg Shipping 4kg
Options
Mic Transformer Factory-Fit Only
Output Transformer Factory-Fit or Retro-fit
XL42 Operators Manual - Page 18
Page 27
Notes
XL42 Operators Manual - Page 19
Page 28
Loading...