25691 Atlantic Ocean Drive, Suite B-3; Lake Forest, CA 92630
Information Hotline 888-36-MICRO
www.microtekelectronics.com
For your protection, please read and observe all safety instructions before operating this system and keep this sheet and
any additional instructions for future reference.
INSTALLATION & USE
OBSERVE WARNINGS: All warnings in the operating instructions should be carefully followed. Do not make any
modifications to the WEM, PIM, or any other MicroTek electronic device, as the unit will no longer comply with FCC
regulations and therefore cancel its warranty.
WATER AND MOISTURE: The Wireless Ethernet Modules used in this system are weatherproof provided they are
installed in accordance to the mounting details listed on page 7 (or included dish manual for the 30-mile systems).
However, further protection or housing is suggested for harsh environments, as moisture damage voids its warranty (as
described on page 22). The Power Injection Modules used in this system are NOT weatherproof. None of the modules
in this system are waterproof and should never be submerged. Severe electrical shock, personal injury or damage to the
equipment may result.
POWER SOURCE: Connect the equipment to a power source only of the type described on the operating instructions or
as marked on the equipment. Excessive or insufficient amperage or voltage can cause extended trouble-shooting or even
damage that could negate its warranty. The power supplies’ cable should not be modified/extended due to the ability to
use up to 300 feet of power over Ethernet (see pg 7, part D). In addition, Ethernet cable running from the PIM to the
WEM should be kept separated from high-voltage cables and/or transformers.
ATTACHMENTS: Use only MicroTek supplied or recommended Power Injection Modules, Power Supplies, CAT5
Cables and weather seals and plugs.
WHEN NOT IN USE: Unplug the power if the equipment is left unattended or unused for long periods of time or
during lightning storms.
REPLACEMENT PARTS: When replacement parts are required, use only replacement parts specified by MicroTek
Electronics, Inc. Unauthorized substitutions may result in damage to the system and will void the warranty.
IMPORTANT SAFETY INSTRUCTION
FCC-Required Information Federal Communications Commission
Radio Frequency Interference Statement for Class A Digital Devices
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
frequencies. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
This equipment is designed to be professionally installed exclusively for fixed point-to-point applications. These products
must be controlled due to radio frequency power output levels emitted with special consideration given to antenna
placement as it relates to human exposure. Compliance is the responsibility of the installer and user.
Radio Frequency Interface Statement
This equipment has been tested and found to comply with the limits for an intentional radiator, pursuant to Part 15,
Subpart C of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy. If not installed and
used in accordance with the instructions, it may cause interference to radio communications. The limits are designed to
provide reasonable protection against such interference in a residential situation. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause interference to radio or television
reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna of the affected radio or television.
• Increase the separation between the equipment and the affected receiver.
•
Connect the equipment and the affected receiver to power outlets on separate circuits.
•Consult the dealer or an experienced radio/TV technician for help.
Shielded cables must be used with this unit to ensure compliance with Class A FCC limits. Changes or modifications to
this unit not expressly approved by the party responsible for compliance could void the users authority to operate the
equipment. Changes or modifications not expressly approved by MicroTek could void the users authority to operate the
equipment.
- ( i ) -
FCC Output Power Restrictions
The FCC does not require licensing to implement this device. License-free operation in the industrial, scientific, and medical
band is documented in FCC Rules Part 15.247. It is the responsibility of the individuals designing and implementing the
radio system to assure compliance with any pertinent FCC Rules and Regulations. This device must be professionally
installed.
Exposure to Radio Frequency Fields
The Minilink 5.8WES is designed to operate at 5.8 GHz with up to 50 Watts EIRP maximum transmit power. This level of
RF energy is above the Maximum Permissible Exposure (MPE) levels specified in FCC OET65:97-01. The following
precautions must be taken during installation of this equipment:
•The installed antenna must not be located in a manner that allows exposure of the general population to the direct
beam path of the antenna at a distance less than 1 Meter. Installation on towers, masts, or rooftops not accessible
to the general population is recommended; or
•Mount the antenna in a manner that prevents any personnel from entering the area within 1 Meter from the front of
the antenna.
•It is recommended that the installer place radio frequency hazard warnings signs on the barrier that prevents
access to the antenna.
• During installation and alignment of the antenna, do not stand in front of the antenna assembly.
• During installation and alignment of the antenna, do not handle or touch the front of the antenna.
These simple precautions must be taken to prevent general population and installation personnel from exposure to RF
energy in excess of specified MPE levels.
Industry Canada Restrictions
This device is in compliance with the applicable sections of the Industry Canada RSS-210 Spectrum Management and
Telecommunications Radio Standard Specification that governs Low Power License-Exempt Radiocommunication Devices.
Specifically, the output EIRP of this device relative to antenna gain is factory set to ensure compliance with section
6.2.2(q1)(iv)(g).
In addition, it is noted for all users that high power radars are allocated as primary users (meaning they have priority) of the
5250-5350 MHz and 5650-5850 MHz frequency bands and these radars could cause interference and/or damage to LELAN
devices such as are covered by this manual.
Environmental Limitations of FCC License-Free Wireless Devices
MicroTek products are engineered to the highest standards and designed to work in a variety of wireless applications and
environments. A wireless environment includes not only a particular site in which the product is installed but also the
installation itself and any extra materials that might be necessary to complete the wireless project. Due to the fact that
environments and installations differ from site to site, MicroTek cannot control the variables required to ensure an ideal
environment. Therefore, it is not possible to guarantee a successful application based on a drawing, application note, quote
or other type of material that MicroTek may provide. Should a quote, drawing, etc. be made available, it is based on the
performance of the WES product in an ideal environment with clear line-of-sight, absence of 5 GHz interference and/or
frequency multi-path reflection. Therefore, MicroTek cannot be held responsible should the products not operate as desired
or should additional products be required to complete a project. In addition, should a particular environment restrict the
usage of the MiniLink WES in any way, MicroTek offers a thirty (30) day return policy from date of original shipment (see
page 3).
- ( ii ) -
FCC REGULATORY ALERT
Regulatory Alert
As of July 20, 2007, a new FCC regulation has gone into effect which impacts operators of
the U-NII band in the United States. As a result of this regulatory change, several MicroTek
products are affected. The new FCC regulation impacts the sale of wireless equipment in the
5.25-5.35 GHz band. The regulation states that all devices imported and marketed after the
July 20
5.35 GHz band.
To comply with FCC regulation, MicroTek has disabled the 5.25-5.35 GHz band. The
following products are still available but will only support operation in the 5.725-5.85 GHz
ISM band.
ML WES-2500
ML WES-2-4
ML WAP
ML WAPOM
ML WSU
ML WSUP
ML WSUOM
ML WES-D
ML WES-OD
ML WES-D1-2
MicroTek is currently working on the firmware change necessary to comply with the new
FCC regulations which require Dynamic Frequency Selection (DFS) and Transmit Power
Control (TPC) for operation in the 5.25-5.35 GHz band.
If one WES System is in use and there are no plans to add to the wireless project then it
might not affect you at all. However, if you are using two or more systems then you may
need to change frequencies according to the available channels. Multiple WES systems set to
channels 0, 1 or 2 (all unavailable 5.2/5.3 GHz frequencies) will all be defaulted to channel 3
(available 5745 MHz). The next available frequency in sequence would be channel 4 (5765
MHz). Channels 3 through 7 are all individual frequencies but channels 0-2 are not available.
th
, 2007 deadline must support radar detection as specified by the FCC in the 5.25-
MicroTek Electronics Product Changes
How Does the FCC Regulation Affect the WES User?
- ( iii ) -
INDEX
SECTION PAGE #
IMPORTANT SAFETY INSTRUCTIONS, FCC NOTICE ---------------- ( i )
RADIO FREQUENCY EXPOSURE, INDUSTRY CANADA ------------- ( ii )
IMPORTANT FCC REGULATORY NOTICE------------------------------- ( iii )
QUICK START GUIDE ----------------------------------------------------------- 2
PRE-INSTALLATION REMINDER, RETURN POLICY ----------------- 3
WEM DESCRIPTION ------------------------------------------------------------- 4
FRONT, REAR & SIDE VIEWS -------------------------------------------------- 4 - 5
PART # DESCRIPTION
ML WAP MiniLink 5.8 GHz Wireless Host / Access Point - Directional
ML WAPOM MiniLink 5.8 GHz Wireless Host / Access Point - Omni-directional
ML WSUOM MiniLink 5.8 GHz Wireless Client / Subscriber Unit - Omni
ML WSU MiniLink 5.8 GHz Wireless Client / Subscriber Unit - Standard
ML WSUP MiniLink 5.8 GHz Wireless Client / Subscriber Unit – 6” x 6”Patch
ML WSUDI MiniLink 5.8 GHz Wireless Client / Subscriber Unit – 18” Dish
ML WEM MiniLink 5.8 GHz Wireless Ethernet Module
ML WEMP MiniLink 5.8 GHz Wireless Ethernet Module w/ 6” patch antenna
ML WEM-30 MiniLink 5.8 GHz Wireless Ethernet Module – 18” Dish
- 1 -
QUICK START PROCEDURES
MicroTek Electronics, Inc. recommends that all equipment be bench tested before being installed onsite.
This test will ensure the equipment is functioning properly.
IMPORTANT:SEENEWFCCREGULATORYALERTONPAGE“( iii )”
W
IRELESS ETHERNET MODULE SETUP
1. Remove the Host and Client from the box, select frequency via the rotary switch at the side of
the unit. (Factory set to channel 0 unless otherwise noted) The channels of each set of
Host/Clients must be matched for the radios to communicate with each other. For multiconnect devices, each Client must be set to the same channel as the Host that it will be
connected to. If connecting more than one Client to a Host, please see the advanced
operation section of this manual for setup.
2. Mount the Client at the remote location. Point the Client as accurately as possible to the point
where Host will be mounted.
3. Remove the Power Injection Modules (PIMs) from the box and determine where they will be
located for each Host/Client. Total distance between a Host/Client and connected Ethernet
device cannot exceed 300 feet (100m). The PIMs can be located anywhere along the 300 feet
of CAT5 cable. Connect a standard CAT5 straight through patch cable to the “Ethernet Out”
port on each PIM to its corresponding Host/Client. “Ethernet In” port on each PIM should be
connected to its respective Ethernet device using a standard CAT5 straight through patch
cable. A crossover cable may be needed depending on your Ethernet device.
4. Connect the included power supplies to the “Power In” port on the PIMs and plug the
transformers into a standard 110VAC outlet. If the Ethernet devices on each end are
connected, powered up and aimed correctly, the “Link Activity”, “Power” and “Signal Level”
LEDs will illuminate. If the Ethernet device is not connected the “Power” LED and “Signal
Level” LEDs only will illuminate. If the “Signal Level” LED is flashing, reposition the
modules to achieve max signal strength. For multi-connect applications, each Client will
show a solid green light when connected to a Multipoint Host. A flashing green LED on the
Multipoint Host Access Point will indicate the number of Client Subscriber Units to which it
is connected.
Note: If a dish is used with the system, assemble the dish and mount the Client/Host in the dish as described in
the dish installation instructions. Then position the dish and connect the CAT5 cable as described above.
Trouble Shooting: If the signal level indicator is not fully lit, video does not appear on the
screen or you are having other operational difficulties, please visit the trouble-shooting
section on page 21 of the operations manual or contact MicroTek toll free at (888) 366-4276
for technical assistance.
- 2 -
PRE-INSTALLATION REMINDERS
The information on the Quick Start Guide is intended for ease of use and application, the following
reminders will help to ensure your satisfaction with MicroTek products and service.
1. Read through this manual before bench testing and installation
2. A helpful IP Address Locating tool is available to download from our website at
3. Perform a bench test incorporating all components of the application
4. Install your MiniLink Wireless Ethernet System
. Download the Locator.exe tool.
5. Toll-free technical assistance is available Monday through Friday (8-5pm PST) at 888-366-
4276
MICROTEK ELECTRONICS RETURN POLICY
MicroTek Electronics wireless products come with a 2-year limited warranty, (see the last page for
warranty information) unless otherwise specified. In addition to the 2-year warranty, products may
be returned within thirty (30) days of shipment provided the products are in like new condition and in
the original packaging. Contact your MicroTek Electronics dealer or distributor to obtain an
authorization to return the merchandise for credit.
Return authorizations for repair can be sent directly to Microtek Electronics with a valid RA number.
Call MicroTek Electronics to obtain an RA number for repair.
- 3 -
MINILINK WIRELESS ETHERNET SYSTEM (WES)
The MiniLink WES is a plug and play CAT5/Ethernet cable replacement device. It operates in the
5.8 GHz U-NII bands on 5 non-overlapping channels. The WES system enables a wide variety of
IP cameras, DVRs, encoders/decoders and web servers to be used across wireless line-of-sight links
in ranges of 500 feet to 30 miles. The system operates independent of any network it may be
connected to.
MINILINK WIRELESS ETHERNET MODULE (WEM)
WEM DESCRIPTION
A. FRONT VIEW B. REAR VIEW
1. LINK ACTIVITY LED
NOTE: Mount
Host/Client so that
Vertical Ethernet
Port is at bottom and
use weatherproof
caps and plugs for
outdoor use as
described on pg 7.
1 2 3 4
Indicates that an Ethernet cable connection between powered Ethernet device & Host or
Client has been established.
2. POWER LED
Indicates the Host or Client has power.
3. SIGNAL LEVEL LED
Indicates the signal strength level between Host/Client. On the MP Host AP, indicates the
number of connected Clients.
4. ETHERNET PORT
Standard RJ-45 connector. Outdoor use- must be weather protected with supplied strainrelief positioned so the connector is at bottom of the case. Weatherproof strain-relief plug
should be tight enough so that it is snug on the cable but not to restrict cable movement.
5. CHANNEL SELECT
Rotary switch for channel selection, factory set to Channel 0. Switch is positioned on the
side of the gray case behind the weatherproof plug.
C. BOTTOM VIEW
1 2
1. ETHERNET PORT
Standard RJ-45 Connector
2. MOUNTING HOLES
(3) ¼ - 20 mounting holes. Two vertical holes
for dish L-bracket (ML WES-12 / ML WES-30
/ ML WSUDI). Far right hole for black swivel mount.
Note: This is not an indication of available throughput.
Plug must be resealed after channel change.
D. SIDE VIEW
3
3. ROTARY CHANNEL SELECT
SWITCH
Shows switch settings for channels 0 – 7.
REPLACE (RESEAL) WEATHERPROOF PLUG
AFTER CHANNEL
POWER CYCLE
(REMOVE WEATHERPROOF PLUG)
SELECT CHANGE AND
- 4 -
POWER INJECTION MODULE (PIM)
Note: The Power Injector Modules are not weatherproof units and must be protected from moisture.
PIM DESCRIPTION
A. TOP VIEW
2. POWER IN – 12-20 VDC Center Positive
2
3
3. ETHERNET OUT – Connect to Host/Client
B. RIGHT SIDE VIEW
2. ETHERNET OUT – Connect to Host/Client
3. POWER IN – Connect to Power Supply
C. LEFT SIDE VIEW
1
1. ETHERNET IN – Connect to Ethernet device
1. POWER LED – Lit when power is on
1. ETHERNET IN – Connect to Ethernet device
- 5 -
Loading...
+ 18 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.