Microtek, ScanMaker, ArtixScan, ScanWizard and ColoRescue are trademarks or
registered trademarks of Microtek International, Inc. All other trademarks or
registered trademarks are the property of their respective holders. Specifications,
software and hardware bundles are subject to change without notice. Not
responsible for typographical errors.
Disclaimer
The contents of this manual have been checked carefully for accuracy, and every
effort has been made to ensure that there are no errors. However, Microtek makes
no guarantee as to the accuracy of the contents of this document and reserves the
right to make changes to the contents without prior warning.
I49-004924 B
September 2013
Microtek International, Inc.
6, Industry East Road 3, Science Based Industrial Park, Hsinchu, Taiwan
Tel: 886-3-5772155, Fax: 886-3-5772598, http://www.microtek.com
2 Medi-6000 Plus User's Manual
Microtek International, Inc.
No. 6, Industry East Road 3,
Science-Based Industrial Park,
Hsinchu, Taiwan
Microtek International, Inc. operates under full compliance with the WEEE
Directive. Among the requirements of the Directive are the marking of any
applicable equipment placed in the EU market with the WEEE symbol, a crossed
out wheeled bin as shown at left; demonstration of the implementation of a takeback program; and meeting recycling targets.
ISO Compliance Statement
Comply with the requirements of the international standard ISO 9001:2000 and
ISO 13485:2003.
Medi-6000 Plus User's Manual 3
Guidance and Manufacturer's Declaration
for EMC Directive
4 Medi-6000 Plus User's Manual
Medi-6000 Plus User's Manual 5
CE Declaration of Conformity (CE DoC)
6 Medi-6000 Plus User's Manual
Safety Precautions
Before using your digitizer, read the following safety guides carefully, which detail
the proper operation of the digitizer and its accessories to prevent injuries or
damage to users or equipment.
Meanings of Symbol Signs
This indicates hazardous situation which, if not payed
CAUTION
attention, could result injury or damage to users or
equipment.
WARNING
Power Supply:
•Use a power source only with a power rating specified on the marking label.
•Ensure to turn off the power of each device before connecting or
disconnecting the cables.
•Insert the plug completely into the outlet, as a loose connection may cause
arcing and result in fire.
•Ensure to hold the plug or connector to disconnect the cable; otherwise, if
you pull the cable only, it may damage the core wire and result in fire or
electric shock.
•Place and route the power supply cord such that it is not likely to be walked
on or pinched by items placed upon or against them, paying particular
attention to the cord near the power plugs, convenience receptacles, and at
the point where it exits from the outlet.
•When the digitizer is left unattended and unused for long periods of time,
unplug it from the wall outlet.
Moving and Storing the Film Digitizer:
This indicates hazardous situation which, if not payed
attention, could result serious injury or death to users.
•Always ensure that the digitizer is stored properly before shipping or moving
it. Quick stops, excessive force, and uneven surfaces may cause the product
to overturn when moving.
•Do not hit or drop the digitizer. The digitizer may be damaged if it receives a
strong jolt, which may result in fire or electric shock if the digitizer is used
without being repaired.
•Do not place the digitizer on any slippery, slanted, or unstable surface. The
product may slide or fall, causing serious injury to people as well as serious
damage to the product.
Medi-6000 Plus User's Manual 7
•Do not use the digitizer near water. Never spill liquid of any kinds on the
product, or it may result in electric shock or other hazards.
•This digitizer should be situated away from heat sources such as radiators,
heat registers, stoves, or other products (including amplifiers) that produce
heat.
•Do not store the digitizer in which it may be exposed to direct sunlight.
Using the Digitizer
•Before using the digitizer, make sure the area of the front cover is clear from
any objects that may cause jams inside.
•When using the digitizer, if your hairs have been jammed into the front cover
of the digitizer, turn off the power switch immediately. Do not attend to
remove your hairs from the front cover when the digitizer is still turned on.
Maintenance and Service:
•When the digitizer is going to be cleaned, ensure to turn off the power of each
device and unplug the power cable from the AC outlet.
•When you need a repair service, unplug the digitizer from the power outlet
and consult qualified service personnel.
•When replacement parts are required, use replacement parts that are specified
by the manufacturer or have the same characteristics as the original parts.
•For safety reasons, ensure to inspect the device before using it. In addition,
carrying out a regular inspection at least once a year.
8 Medi-6000 Plus User's Manual
Labels and Markings
On The Device
or
CE 0120 label
TFDA label
(for Taiwan shipping only)
Power label
(MIC or MIT)
This label indicates that when
an emergency situation
happens, turn off the power
switch immediately.
A. Fixing Film Jams ....................................................................... 40
B. Troubleshooting ........................................................................ 41
C. Optional Auto Film Feeder (AFF) .................................................. 42
Installing the Auto Film Feeder (AFF) .......................................... 43
Positioning the X-ray Films ....................................................... 4 5
Scanning X-ray Films using the Auto Film Feeder (AFF) ............... 48
D. Specifications ............................................................................ 50
12 Medi-6000 Plus User's Manual
Knowing about Your Film Digitizer
The Medi-6000 Plus is a sheet-fed transparency film digitizer that can easily
transfer radiographs and x-ray films into a digital format. The digitized images are
intended for the use in primary, secondary and over reading applications. This
device is not to be used for primary image diagnosis in mammography. Also, it is
specifically designed for the trained medical professionals or staff. The Medi6000 Plus can capture details in bright and dark areas of x-ray films and provide
the medical professionals a convenient method to digitize the roentgenogram for
the electric data storage.
Features of the Medi-6000 Plus
The Medi-6000 Plus comes with several important features, including the
following:
•Premium Image Quality — With a high optical resolution of 600 dpi, a
dynamic range of 4.0 Dmax, and the 16-bit grayscale, the Medi-6000 Plus
allows users to get better image details in just seconds.
•Energy-saving LED light source — Adopting LEDs as the light source, when
the digitizer is detected by the system, there are no requirements for any
warm-up time before carrying out the scan, which boots your productivity and
reduces energy costs amazingly. With its stable performance, the image
quality will remain consistent even after used for a certain period of time.
•Various sizes of x-ray films — The Medi-6000 Plus covers various sizes of
sheets or x-ray films from 2.5" x 2.5" to 14" x 35", which offers more
flexibility to digitize old records or x-ray films.
•Ultra high scanning speed — The Medi-6000 Plus increases your productivity
with fast scanning speed, which is less than 12 seconds at 300 dpi for
grayscale scans.
•Hi-Speed USB (USB 2.0) port — Hi-Speed USB (USB 2.0) is capable of high
data transfer rates of up to 480 Mbit/sec.
•Easy to operate, clean and maintain — The Medi-6000 Plus requires virtually
no routine maintenance and no daily cleaning, which is ideal for busy
radiology departments.
•Microtek ScanWizard Medi software — The friendly user interface of
ScanWizard Medi stores X-ray pictures in a computer readable format, offering
an easy and quick access and management.
— Auto-scan: With this feature, the Medi-6000 Plus automatically performs
a scan job once when it detects a X-ray film put on the Feed Tray. No
matter a novice or an expert can start scanning immediately.
Medi-6000 Plus User's Manual 13
— Auto crop: This feature automatically detects the size of the original
image, crops the full scan frame to fit the image, and removes unwanted
black borders.
— Auto density: This feature enables the digitizer to optimize the image
density automatically when scanning a X-ray film. It automatically defines
the lightest and darkest pixels in a scanned image and then redistribute
the intermediate pixel values proportionately.
— Customized exposure: This manual setting tool allows you to customize
an exposure time for the scanned image. It enhances the visibility of
extreme dark film, delivering a better scanning result and improving the
quality of saved files.
System Requirements
In order to use your Medi-6000 Plus, your computer must satisfy the following
system requirements:
•CD-ROM drive (for installing software)
•Color display with 24-bit color output capability
•512 MB RAM or above
•Pentium IV PC or higher with Hi-Speed USB (USB 2.0) port
•Microsoft Windows XP, Vista, Windows 7 or Windows 8
14 Medi-6000 Plus User's Manual
Unpacking Your Film Digitizer
Looking for Damage
While unpacking your digitizer, inspect the shipping carton for any signs of
mishandling or damage. The digitizer’s packing carton and padding material have
been carefully chosen to prevent damage to the unit in shipping and can withstand
a reasonable amount of pressure.
After unpacking your digitizer package, refer to the later section to ensure that you
received all of the parts necessary for digitizer setup. If there are any damaged or
missing parts, notify the shipper immediately or contact customer service.
NOTE: Save the carton and all packing materials. If you need to ship the digitizer
later, it is recommended that you should repack it using the original wire ties,
plastic bags, foam supports and cartons, which protects your digitizer from
unnecessary damage. Refer to the later section “How to Repack Your Film Digitizer
for Shipping” for the detail.
Unpacking Package Contents
After unpacking the shipping carton, follow the steps shown below to take out
your digitizer and other accessory components.
1. Ensure that you put your shipping carton
toward the right direction. Then, lift up the
top cover.
Medi-6000 Plus User's Manual 15
Loading...
+ 35 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.