Configuration and Service Tools for Micro Motion™
and Rosemount Flow™ Transmitters
Quick Start Guide
February 2020
About this guide
This quick start guide provides basic installation guidelines for the
Micro Motion
®
ProLink III software and ProcessViz Software. ProcessViz
Software is used to display trend graphics from logged data files. For
complete instructions about using the software, refer to the ProLink III user
manual or go to the product page at www.micromotion.com to view
animated demonstrations.
To install and run ProLink III and/or ProcessViz software, your
personal computer must meet or exceed the following
requirements:
1 GHz Pentium
One of the following [for a 32-bit (x86) or 64-bit (x64) processor]:
- Windows 10
- Windows 8.x
- Windows 7 and 1 GB RAM
- Windows Vista with Service Pack 1 and 1 GB RAM
Available hard disk space:
- 1 GB for 32-bit (x86) processor
- 2 GB for 64-bit (x64) processor
Video with support for 24-bit color graphics
1024 x 768 display minimum, 1280 x 800 or higher widescreen
format preferred
ProLink III Software Installation kits
ProLink III installation kits are available for the following connection
types:
RS-485 to serial port (RS-232)
RS-485 to USB port
Bell 202 to serial port (RS-232)
Bell 202 to USB port
USB-A (male) to USB-A (male) connection for Micro Motion 5700
and Micro Motion 4200 transmitters (supplied with transmitter)
The installation kits include converters and assorted adapters,
cables, and testers. If you need a ProLink III installation kit, contact
your Emerson Flow representative.
®
4 processor
Quick Start Guide
English
中国的
Deutsch
EspañolFrançais
Português
русский
1
Quick Start Guide
February 2020
Important
If you do not use a converter supplied by Emerson, it is your responsibility to
ensure that your equipment provides equivalent functionality. See the
ReadMe.txt file in the ProLink III installation directory, or contact Emerson Flow
customer support for assistance or additional information.
A Windows driver is required for correct operation of the USB converter. This
driver is provided with the installation kit. Ensure that the driver is installed
before attempting to connect through the USB port. If this driver is not
installed, Windows will not recognize the USB converter or cable
plugged into the USB port.
when it is
ProLink III software
Installation
1. Ensure that the ProLink III/ProcessViz CD-ROM is in the optical
drive.
2. Locate the setup.exe file. The file is in the root directory on the CDROM (for example, D:\setup.exe, where “D” is your CD-ROM or
DVD drive letter).
3. Right-click the setup.exe file, and then choose Run as
administrator.
Important
If you do not run the setup.exe file as an administrator, the program may
appear to install correctly, but it will not run properly.
4. Select ProLink III.
5. Follow the on-screen instructions to generate the temporary
ProLink III license, using the Professional edition. The temporary
license allows you to run ProLink III for 7 days, starting from the
current date and time. You must obtain and configure a site key to
validate the permanent license.
Important
Be sure to configure the site key before the temporary license expires.
When the temporary license expires, you will not be able to use ProLink III.
ProcessViz cannot be used until a permanent license site key is obtained
and validated.
2
February 2020
6. To obtain a ProLink III site key:
a. Start ProLink III and choose File > License.
b. Enter your serial number in the Serial Number field.
c. Press Get Site Key.
The Site Key field is automatically populated.
d. Select Validate.
Tip
See the ProLink III Help box on the License dialog for other methods of
obtaining a license.
Quick Start Guide
English
中国的
Wiring the PC to the transmitter
1. Connect the appropriate converter to your PC’s serial or USB
port, using adapters as required.
For connections using the Bell 202 physical layer, use the
Bell 202 to RS-232 converter or Bell 202 to USB converter.
For connections using the RS-485 physical layer, use the
RS-485 to RS-232 converter or RS-485 to USB converter.
For connections using Modbus/TCP, use the Modbus/RTU to
Modbus/TCP converter.
For USB connections on Model 5700 devices, use a USB-A to
USB-A type cable.
2. For Bell 202 or RS-485 connections, connect the two leads of the
converter to the appropriate terminals on your transmitter. See
the ProLink III user manual (located on the installation disc) for
more information.
For Modbus /TCP connections, follow the manufacturer
instructions for connecting the converter to your transmitter
network.
WARNING!
To avoid causing an explosion:
Do not open a non-intrinsically safe wiring compartment in a hazardous area.
Do not use the computer running ProLink III in a hazardous area without
following the proper procedures (such as obtaining a hot work permit).
An improper connection between ProLink III and the transmitter can cause a
spark, which could lead to an explosion in an explosive atmosphere. Be sure to
connect ProLink III to the transmitter using safe methods.
Deutsch
EspañolFrançais
Português
русский
3
Quick Start Guide
3. Add resistance if required. Many HART connections require added
resistance. See the ProLink III user manual for more information.
4. For Modbus network connections, ensure that ProLink III is the
only Modbus master currently active on the network.
There are additional methods for connecting ProLink III to your
transmitter, including connecting over a network. See the transmitter
configuration and use manual for complete information.
Connecting to a device with ProLink III
1. Start ProLink III.
2. On the ProLink III start-up screen, select Connect to Physical
Device. The Connect to Physical Device screen displays.
3. Use the Protocol parameter to specify your connection type. For
HART/Bell 202 with USB port connections using the supplied
converter, enable Toggles RTS.
4. Set Serial Port to the PC COM port you are using to connect to the
transmitter.
If you are using a USB converter and need to locate the COM port
for the connection, refer to the Windows Device Manager to
obtain that information.
5. Specify additional communication parameters.
If you are making a service port connection or HART/Bell 202
connection, default values are used for all remaining
communication parameters. No configuration is required.
If you are connecting to a Model 5700 device, or to an MVD
Direct Connect system, the core processor auto-detects
incoming communications settings and switches to match.
If you are connecting to any Model 2400S or 9739 MVD devices
using the service port:
- For point-to-point connections, you can use a service port
connection type.
- For multidrop network connections, you can use any RS-485
connection type and specify the transmitter’s Modbus
address. The transmitter auto-detects incoming
communications settings and switches to match.
February 2020
4
February 2020
For all other connection types, see the ProLink III user manual
Quick Start Guide
English
for more information on the default communication values. If
your transmitter is not using default values, refer to site
documentation for the values you are using.
Note
ProLink III automatically sets data bits appropriately for the configured protocol.
Even though a data bits parameter may be configured in the transmitter, you do
not need to configure it in ProLink III. HART protocol is always 8 data bits. If your
transmitter is configured for Modbus with 7 data bits, specify Modbus ASCII; if your
transmitter is configured for Modbus with 8 data bits, specify Modbus RTU.
If you know the unit’s address you can connect that way or by the
tag, or you can poll to find a list of transmitters and then connect to
the one you want.
6. Select the Connect button. ProLink III will attempt to make the
connection.
If you are connecting to a Model 1500/2500, Series 3000, or
LFT DIN rail mount transmitter, the RS-485 terminals are
available in service port mode for 10 seconds after transmitter
power-up.
- If a service port connection is made during this interval, the
terminals will remain in service port mode until the next
power cycle, and you can make a service port connection at
any time.
- If no connection is made during this interval, the terminals
switch to RS-485 mode and you can make an RS-485
connection at any time. If the terminals are in one mode and
you want to use the other mode, you must power cycle the
transmitter to reset the mode, then make the appropriate
connection at the appropriate time.
If you are using any other connection type, you can make the
connection at any time.
7. If ProLink III fails to connect:
Ensure that you installed the software as administrator. If
unsure, reinstall the software, making sure that the setup.exe
program is Run as administrator.
For Mobus/RS-485 connections:
- Swap the RS-485 leads at the transmitter terminals and try
again.
中国的
Deutsch
EspañolFrançais
Português
русский
5
Quick Start Guide
- Ensure that ProLink III is the only Modbus master currently
active on the network.
- If you are using Modbus ASCII protocol, ensure that Modbus
ASCII support is enabled on your transmitter.
- Try adding resistance to the connection. See the ProLink III
user manual for more information.
For HART/Bell 202 connections:
- Make sure that you have a 250–600Ω resistor in the proper
location.
- To Model 1700/2700, 8600D, 8712E, 8712H, 8732E, or
8800D transmitters with the intrinsically safe outputs option
board, ensure that the terminals are externally powered.
For HART connections to the USB port:
- Ensure that you have checked Toggles RTS in the ProLink III
Connect to Physical Device screen.
- Ensure that the required Windows driver is installed on your
PC. If this driver is not installed, Windows will not recognize
the USB converter when it is plugged into the USB port.
For additional troubleshooting suggestions, see the ProLink III
user manual.
ProcessViz software
Installation
1. Ensure that the ProLink III/ProcessViz CD-ROM is in the optical
drive.
2. Locate the setup.exe file. The file is in the root directory on the CDROM (for example, D:\setup.exe, where “D” is your CD-ROM or
DVD drive letter).
3. Right-click the setup.exe file, and then choose Run as
administrator.
Important
If you do not run the setup.exe file as an administrator, the program may
appear to install correctly, but it will not run properly.
February 2020
4. Select ProcessViz.
5. Follow the on-screen instructions to complete the installation.
6
February 2020
Quick Start Guide
6. Run ProcessViz for the first time to obtain a site key.
Note
ProcessViz cannot be used until a permanent license site key is obtained
and validated.
7. To obtain a ProcessViz site key:
a. Select License under the System menu.
b. Enter your serial number in the Serial Number field.
c. Press Get Site Key.
The Site Key field is automatically populated.
d. Select Validate.
For further information
For more information on using ProLink III or ProcessViz refer to the
ProLink III and ProcessViz user manual. In typical installations, the
manual is installed with the ProLink III program, and can be opened
from the Micro Motion folder in the Windows Start menu. You can
also find the ProLink III user manual on the installation CD, in the root
directory, or at www.emerson.com.
To view animated demonstrations on using the key features of the
software, go to the product page at: www.emerson.com.
Note
Adobe Acrobat Reader is required to read the ProLink III manual. The self-extracting
setup file for this program is provided in the root directory of the ProLink III
installation CD, if Acrobat Reader is not already installed on your system. The
ProLink III setup program does not install Acrobat Reader automatically.
English
中国的
Deutsch
EspañolFrançais
Português
русский
7
Quick Start Guide
February 2020
8
2020 年 2 月
快速入门指南
在你开始之前
个人电脑要求
要安装和运行 ProLink III 和 / 或 ProcessViz 软件,您的个人电脑必须
满足或超过以下要求:
7. 获取 ProcessViz 现场密钥:
a. 选择系统菜单下的证书。
b. 在序列号字段中输入您的序列号。
c. 按下获取现场密钥。
随后将自动填充现场密钥字段。
d. 选择验证。
更多信息
有关使用 ProLink III 要么 ProcessViz 的更多信息,请参阅 ProLink III
和 ProcessViz 用户手册。在典型安装中,该手册随 ProLink III 程序一
起安装,你可在 Windows 开始菜单的 Micro Motion 文件夹中打开
它。你也可以在安装光盘的根目录或网站 www.emerson.com 上找
到 ProLink III 用户手册。
要查看使用本软件关键功能的动画演示,转到产品页面:
www.emerson.com。
注
需要安装 Adobe Acrobat Reader 才能阅读 ProLink III 手册。如果你的系统尚未安
装 Acrobat Reader,你可以在 ProLink III 安装光盘的根目录中找到此程序的自解压
安装文件。 ProLink III 安装程序不会自动安装 Acrobat Reader。
14
Februar 2020
Einführung
PC Anforderungen
Für Installation und Betrieb von ProLink III und/oder ProcessViz muss
Ihr Computer mindestens folgende Anforderungen erfüllen:
1 GHz Pentium
Eines der folgenden [für einen 32-Bit- (x86) oder 64-Bit- (x64)
Prozessor]:
- Windows 10
- Windows 8.x
- Windows 7 und 1 GB RAM
- Windows Vista mit Service Pack 1 und 1 GB RAM
Verfügbarer Festplattenspeicherplatz:
- 1 GB für 32-Bit (x86) Prozessor
- 2 GB für 64-Bit (x64) Prozessor
Video mit Support für 24-Bit Bildschirm Farbtiefe
1.024 x 768 Display Minimum, 1.280 x 800 oder höheres
Breitbildformat bevorzugt
ProLink III Software-Installations-Sätze
ProLink III Installations-Sätze sind für folgende Anschlussarten
erhältlich:
RS-485 an seriellen Port (RS-232)
RS-485 an USB Port
Bell 202 an seriellen Port (RS-232)
Bell 202 an USB Port
USB-A- auf USB-A-Verbindung (beide Stecker) für
Micro Motion 5700 und Micro Motion 4200 Messumformer
(im Messumformerlieferumfang enthalten)
Die Installations-Sätze beinhalten den Konverter sowie zugehörige
Adapter, Kabel und Testeinrichtungen. Wenn Sie einen ProLink III
Installations-Satz benötigen, setzen Sie sich mit Emerson Flow in
Verbindung.
®
4 Prozessor
Kurzanleitung
English
中国的
Deutsch
EspañolFrançais
Português
15
русский
Kurzanleitung
Februar 2020
Wichtig
Wenn Sie einen Konverter verwenden, der nicht von Emerson geliefert ist, sind Sie
dafür verantwortlich, dass Ihre Ausrüstung äquivalente Funktionalität aufweist. Zur
Unterstützung oder weiterer Informationen siehe Datei ReadMe.txt im ProLinkIII
Installations-Verzeichnis oder setzen Sie sich mit Emerson Flow in Verbindung.
Ein Windows Treiber ist für den korrekten Betrieb des USB Konverters erforderlich.
Der Treiber wird mit dem Installations-Satz geliefert. Stellen Sie sicher, dass dieser
Treiber installiert ist bevor Sie versuchen über den USB Port eine Verbindung
herzustellen. Ist dieser Treiber nicht installiert, erkennt Windows den USB Konverter
oder das Kabel nicht, wenn er bzw. es am USB Port angeschlossen ist.
ProLink III-Software
Installation
1. Stellen Sie sicher, dass sich die ProLink III-/ProcessViz-CD-ROM im
optischen Laufwerk befindet.
2. Suchen Sie die setup.exe-Datei. Die Datei finden Sie im
Hauptverzeichnis auf der CD-ROM (z. B.: D:\setup.exe, wobei „D“
Ihr CD-ROM- oder DVD-Laufwerk ist).
3. Klicken Sie mit der rechten Maustaste auf die setup.exe-Datei und
wählen Sie dann Als Administrator ausführen aus.
Wichtig
Wenn Sie die setup.exe-Datei nicht als Administrator ausführen, wird das
Programm möglicherweise korrekt installiert, aber es funktioniert nicht
richtig.
4. Wählen Sie Prolink III aus.
5. Folgen Sie den Anweisungen auf dem Bildschirm, um eine
temporäre Lizenz für ProLink III mit der Professional Edition zu
erstellen. Diese temporäre Lizenz ermöglicht es Ihnen, ProLink III
für 7 Tage zu nutzen, angefangen vom aktuellen Datum und Zeit.
Für eine permanente Lizenz müssen Sie einen Standortschlüssel
erwerben und konfigurieren.
Wichtig
Stellen Sie sicher, dass Sie den Schlüssel konfigurieren bevor die
temporäre Lizenz abläuft. Nach Ablauf der temporären Lizenz ist die
Nutzung von ProLink III nicht mehr möglich. Das ProcessViz kann nicht
verwendet werden, bis ein Standortschlüssel für die permanente Lizenz
eingeholt und validiert wurde.
16
Loading...
+ 40 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.