1 Quick installation and startup
This procedure provides a summary of installation and startup steps. For installation details, see the EtherNet/IP Module User Manual.

1.1 Components

Ensure that you have all required components:
Micro Motion EtherNet/IP Module
Power connector
Micro Motion EtherNet/IP Resource CDMicro Motion EtherNet/IP Module User ManualEDS fileMicroMotion Ethernet Config Tool
Configuration cable
Modbus serial cable and connector (included)
Ethernet cable and connector (not included)

1.2 Set up the module with MVD Direct Connect

Use this procedure only if you are installing the module with MVD Direct Connect.
Procedure
1. Mount and wire the core processor and barrier.
Figure 1-1: Barrier
A. I.S. terminals for connection to core processor B. Non-I.S. terminals for connection to remote host and power supply
2. Power up the core processor and barrier.
3. Set the Modbus address on the core processor to 1.
Postrequisites
Continue to Mount, wire, and set the network settings.
2 Micro Motion EtherNet/IP Module
1
2
January 2019 Quick Start Guide

1.3 Set up the transmitter

Use this procedure only if you are installing the module with a transmitter.
Procedure
1. Mount the transmitter and wire it to the sensor and to power.
2. Power up the transmitter.
3. Set the Modbus address on the transmitter to 1.
4. If your transmitter does not support Modbus auto-detect, configure the RS-485 terminals as follows:
Modbus RTU
38400 baud
2 stop bits
No parity
Postrequisites
Continue to Mount, wire, and set the network settings.

1.4 Mount, wire, and set the network settings

Use this procedure to mount, wire, and set the network settings for both the transmitter and MVD Direct Connect configurations.
Procedure
1. Ensure that the following slot registers are available for use by the EtherNet/IP Module:
655–750
751–846
If these slot registers are currently in use, you must reprogram your Modbus interface.
2. Mount the EtherNet/IP Module on the DIN rail.
Figure 1-2: Snap on
Quick Start Guide 3
2
1
Quick Start Guide January 2019
Figure 1-3: Snap off
3. Wire the EtherNet/IP Module to power (24 VDC).
Figure 1-4: Power connections on the EtherNet/IP module
A. 24 VDC B. Ground
4. Install the Modbus serial cable between the EtherNet/IP Module and the RS-485 terminals on the transmitter (or the I.S. barrier, if present).