1 Quick installation and startup
This procedure provides a summary of installation and startup steps. For
installation details, see the EtherNet/IP Module User Manual.
1.1 Components
Ensure that you have all required components:
• Micro Motion EtherNet/IP Module
• Power connector
• Micro Motion EtherNet/IP Resource CD
— Micro Motion EtherNet/IP Module User Manual
— EDS file
— MicroMotion Ethernet Config Tool
• Configuration cable
• Modbus serial cable and connector (included)
• Ethernet cable and connector (not included)
1.2 Set up the module with MVD Direct Connect
Use this procedure only if you are installing the module with MVD Direct
Connect.
Procedure
1. Mount and wire the core processor and barrier.
Figure 1-1: Barrier
A. I.S. terminals for connection to core processor
B. Non-I.S. terminals for connection to remote host and power supply
2. Power up the core processor and barrier.
3. Set the Modbus address on the core processor to 1.
Postrequisites
Continue to Mount, wire, and set the network settings.
2 Micro Motion EtherNet/IP Module

January 2019 Quick Start Guide
1.3 Set up the transmitter
Use this procedure only if you are installing the module with a transmitter.
Procedure
1. Mount the transmitter and wire it to the sensor and to power.
2. Power up the transmitter.
3. Set the Modbus address on the transmitter to 1.
4. If your transmitter does not support Modbus auto-detect, configure
the RS-485 terminals as follows:
• Modbus RTU
• 38400 baud
• 2 stop bits
• No parity
Postrequisites
Continue to Mount, wire, and set the network settings.
1.4 Mount, wire, and set the network settings
Use this procedure to mount, wire, and set the network settings for both the
transmitter and MVD Direct Connect configurations.
Procedure
1. Ensure that the following slot registers are available for use by the
EtherNet/IP Module:
• 655–750
• 751–846
If these slot registers are currently in use, you must reprogram your
Modbus interface.
2. Mount the EtherNet/IP Module on the DIN rail.
Figure 1-2: Snap on
Quick Start Guide 3

Quick Start Guide January 2019
Figure 1-3: Snap off
3. Wire the EtherNet/IP Module to power (24 VDC).
Figure 1-4: Power connections on the EtherNet/IP module
A. 24 VDC
B. Ground
4. Install the Modbus serial cable between the EtherNet/IP Module and
the RS-485 terminals on the transmitter (or the I.S. barrier, if present).
4 Micro Motion EtherNet/IP Module