Micro Motion® Model 3500 Transmitter
(MVD) or Model 3300 Controller
Installation manual for panel mount
Safety and approval information
This Micro Motion product complies with all applicable European directives when properly installed in accordance with the
instructions in this manual. Refer to the EC declaration of conformity for directives that apply to this product. The EC declaration of
conformity, with all applicable European directives, and the complete ATEX Installation Drawings and Instructions are available on
the internet at www.micromotion.com or through your local Micro Motion support center.
Information affixed to equipment that complies with the Pressure Equipment Directive can be found on the internet at
www.micromotion.com/documentation.
For hazardous installations in Europe, refer to standard EN 60079-14 if national standards do not apply.
Other information
Full product specifications can be found in the product data sheet. Troubleshooting information can be found in the transmitter
configuration manual. Product data sheets and manuals are available from the Micro Motion web site at www.micromotion.com/
documentation.
Return policy
Micro Motion procedures must be followed when returning equipment. These procedures ensure legal compliance with government
transportation agencies and help provide a safe working environment for Micro Motion employees. Failure to follow Micro Motion
procedures will result in your equipment being refused delivery.
Information on return procedures and forms are available on our web support system at www.micromotion.com, or by phoning the
Micro Motion Customer Service department.
Micro Motion customer service
Email:
• Worldwide: flow.support@emerson.com
• Asia-Pacific: APflow.support@emerson.com
Telephone:
North and South AmericaEurope and Middle EastAsia Pacific
United States800-522-6277U.K.0870 240 1978Australia800 158 727
3.1Connect the input and output wiring ..................................................................................... 13
3.2Connect the Model 3500 to the sensor .................................................................................. 16
3.3Wire the sensor to the remote core processor........................................................................ 24
3.4Connect the power supply wiring........................................................................................... 25
Installation Manual3
4Model 3500 Transmitters or Model 3300 Peripherals - Panel Mount
1Planning
This installation manual explains basic installation guidelines for installing the Micro Motion
Model 3300 or Model 3500 MVD applications platform.
For information on I.S. applications, refer to Micro Motion approval documentation.
For complete instructions about configuration, maintenance, and service, refer to the
instruction manual shipped with the transmitter.
WARNING!
Improper installation in a hazardous area can cause an explosion.
For information about hazardous applications, refer to the appropriate Micro Motion approval
documentation, shipped with the meter or available from the Micro Motion web site.
WARNING!
Hazardous voltage can cause severe injury or death.
Install transmitter and complete all wiring before supplying power.
CAUTION!
Improper installation can cause measurement error or meter failure. Follow all instructions.
Planning
1.1Installation kit
The installation kit includes a bezel, frame, two mounting brackets with screws, a power
supply wiring connector, and a retaining clip assembly for power supply wiring. See Figure
1-1).
The applications platform fits through a 5 7/16-inch (138 mm) square cutout in a panel
that is 5/64 inch (2 mm) to 1/2 inch (13 mm) thick. The bezel provides a IP65 watertight
seal between the panel cutout and the applications platform housing. See Figure 1-1.
In addition, the installation kit includes either:
•A bracketed wiring connector for screw-type connectors. See Figure 3-2.
•I/O cables and connectors. See Figure 3-3.
Installation Manual5
Planning
Power supply wiring connector
Retaining-clip assembly for power supply
wiring
2 x mounting bracket with screw
Frame
Bezel
Panel thickness:
5/64 inch (2 mm) minimum
1/2 inch (13 mm) maximum
Figure 1-1: Panel-mount installation kit
1.2Choose a location
Choose a location for the transmitter based on the requirements described below.
1.2.1Environmental requirements
Install the Model 3300 or Model 3500 where the ambient temperature is between –4 to
+140 °F (–20 to +60 °C).
1.2.2Dimensions
Model typeDimension drawing
Screw-type wiring connectorsFigure 1-2
I/O cablesFigure 1-3
See Figure 3-1 and Figure 3-3 for illustrations of screw-type connectors versus I/O cables.
6Model 3500 Transmitters or Model 3300 Peripherals - Panel Mount
Figure 1-2: Panel-mount screw-type dimensions
4 1/2
(114)
6 1/2
(165)
Bezel
Panel
6
(152)
Approvals tag
Frame
Intrinsic safety shield
(Model 3500 only)
7 3/4
(197)
1/2
(12)
8 1/2
(216)
6
(152)
inches
(mm)
6 11/16
(170)
6 1/2
(165)
Bezel
Panel
6
(152)
6 11/16
(170)
Minimum 4 1/4"
(108 mm) bend radius
Approvals tag
1/2
(12)
8 3/4
(222)
5 5/16
(135)
Frame
6
(152)
inches
(mm)
Planning
Figure 1-3: Panel-mount dimensions with I/O cables
Installation Manual7
Planning
Model 3500
4-wire cable
Sensor
Core processor
(standard or enhanced)
Sensor
Junction box
9-wire cable
4-wire cable
Model 3500
Core processor
(standard only)
1.3Cable lengths
Maximum cable length from the sensor to the Model 3500 transmitter depends on the
installation type and cable type.
Installation typeMaximum cable length
4-wire remote transmitterSee Figure 1-4, and Table 1-1 for maximum length of the
Remote core processor with remote
transmitter
If you are installing the Model 3300 applications peripheral in combination with a
transmitter, the maximum cable length between the transmitter frequency output and the
Model 3300 frequency input is 500 feet (150 meters).
Figure 1-4: 4-wire remote transmitter
4-wire cable
See Figure 1-5, and Table 1-1 for maximum length of the
4-wire cable and the 9-wire cable
Figure 1-5: Remote core processor with remote transmitter
8Model 3500 Transmitters or Model 3300 Peripherals - Panel Mount
Table 1-1: Maximum cable lengths between sensor and transmitter
Step 1
Step 2
Step 3
Step 4
Cable typeWire gaugeMaximum length
Micro Motion 4-wireNot applicable• 1000 ft (300 m) without
Ex-approval
• 500 ft (150 m) with
IIC-rated sensors
• 1000 ft (300 m) with
IIB-rated sensors
Micro Motion 9-wireNot applicable60 ft (20 m)
User-supplied 4-wireVDC 22 AWG (0.35 mm
VDC 20 AWG (0.5 mm2)500 ft (150 m)
VDC 18 AWG (0.8 mm
RS-485 22 AWG (0.35 mm
larger
2
)300 ft (90 m)
2
)1000 ft (300 m)
2
) or
1000 ft (300 m)
1.4Install the Model 3300 or Model 3500 in the
panel
Planning
Refer to Figure 1-6 and follow these steps:
1. Insert the Model 3300 or Model 3500 through the cutout.
2. Slide the frame over the housing.
3. Insert the posts on the brackets into the rails on the housing.
4. Tighten the screws evenly to 10 to 14 inch-pounds (1,13 to 1,38 Nm) to ensure a
watertight seal between the gasket and the panel.
Figure 1-6: Panel installation steps
Installation Manual9