Micro Motion Installation Instructions: 3500 MVD Panelmount Installation Instruction | Micro Motion Manuals & Guides

Installation Manual
20000885, Rev BA
February 2015
Micro Motion® Model 3500 Transmitter (MVD) or Model 3300 Controller
Installation manual for panel mount
This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this manual. Refer to the EC declaration of conformity for directives that apply to this product. The EC declaration of conformity, with all applicable European directives, and the complete ATEX Installation Drawings and Instructions are available on the internet at www.micromotion.com or through your local Micro Motion support center.
Information affixed to equipment that complies with the Pressure Equipment Directive can be found on the internet at
www.micromotion.com/documentation.
For hazardous installations in Europe, refer to standard EN 60079-14 if national standards do not apply.
Other information
Full product specifications can be found in the product data sheet. Troubleshooting information can be found in the transmitter configuration manual. Product data sheets and manuals are available from the Micro Motion web site at www.micromotion.com/
documentation.
Return policy
Micro Motion procedures must be followed when returning equipment. These procedures ensure legal compliance with government transportation agencies and help provide a safe working environment for Micro Motion employees. Failure to follow Micro Motion procedures will result in your equipment being refused delivery.
Information on return procedures and forms are available on our web support system at www.micromotion.com, or by phoning the Micro Motion Customer Service department.
Micro Motion customer service
Email:
Worldwide: flow.support@emerson.com
Asia-Pacific: APflow.support@emerson.com
Telephone:
North and South America Europe and Middle East Asia Pacific
United States 800-522-6277 U.K. 0870 240 1978 Australia 800 158 727
Canada +1 303-527-5200 The Netherlands +31 (0) 704 136 666 New Zealand 099 128 804
Mexico +41 (0) 41 7686 111 France 0800917901 India 800 440 1468
Argentina +54 11 4837 7000 Germany 0800 182 5347 Pakistan 888 550 2682
Brazil +55 15 3413 8000 Italy 8008 77334 China +86 21 2892 9000
Venezuela +58 26 1731 3446 Central & Eastern +41 (0) 41 7686 111 Japan +81 3 5769 6803
Russia/CIS +7 495 981 9811 South Korea +82 2 3438 4600
Egypt 0800 000 0015 Singapore +65 6 777 8211
Oman 800 70101 Thailand 001 800 441 6426
Qatar 431 0044 Malaysia 800 814 008
Kuwait 663 299 01
South Africa 800 991 390
Saudia Arabia 800 844 9564
UAE 800 0444 0684
Contents
Chapter 1 Planning....................................................................................................................... 5
1.1 Installation kit ........................................................................................................................ 5
1.2 Choose a location................................................................................................................... 6
1.3 Cable lengths ......................................................................................................................... 8
1.4 Install the Model 3300 or Model 3500 in the panel ................................................................. 9
Chapter 2 Mounting..................................................................................................................... 11
2.1 Mount the core processor ...................................................................................................... 11
Chapter 3 Wiring ......................................................................................................................... 13
3.1 Connect the input and output wiring ..................................................................................... 13
3.2 Connect the Model 3500 to the sensor .................................................................................. 16
3.3 Wire the sensor to the remote core processor........................................................................ 24
3.4 Connect the power supply wiring........................................................................................... 25
Installation Manual 3
4 Model 3500 Transmitters or Model 3300 Peripherals - Panel Mount

1 Planning

This installation manual explains basic installation guidelines for installing the Micro Motion Model 3300 or Model 3500 MVD applications platform.
For information on I.S. applications, refer to Micro Motion approval documentation. For complete instructions about configuration, maintenance, and service, refer to the
instruction manual shipped with the transmitter.
WARNING!
Improper installation in a hazardous area can cause an explosion.
For information about hazardous applications, refer to the appropriate Micro Motion approval documentation, shipped with the meter or available from the Micro Motion web site.
WARNING!
Hazardous voltage can cause severe injury or death.
Install transmitter and complete all wiring before supplying power.
CAUTION!
Improper installation can cause measurement error or meter failure. Follow all instructions.
Planning

1.1 Installation kit

The installation kit includes a bezel, frame, two mounting brackets with screws, a power supply wiring connector, and a retaining clip assembly for power supply wiring. See Figure
1-1).
The applications platform fits through a 5 7/16-inch (138 mm) square cutout in a panel that is 5/64 inch (2 mm) to 1/2 inch (13 mm) thick. The bezel provides a IP65 watertight seal between the panel cutout and the applications platform housing. See Figure 1-1.
In addition, the installation kit includes either:
A bracketed wiring connector for screw-type connectors. See Figure 3-2.
I/O cables and connectors. See Figure 3-3.
Installation Manual 5
Planning
Power supply wiring connector
Retaining-clip assembly for power supply
wiring
2 x mounting bracket with screw
Frame
Bezel
Panel thickness: 5/64 inch (2 mm) minimum 1/2 inch (13 mm) maximum
Figure 1-1: Panel-mount installation kit

1.2 Choose a location

Choose a location for the transmitter based on the requirements described below.
1.2.1 Environmental requirements
Install the Model 3300 or Model 3500 where the ambient temperature is between –4 to +140 °F (–20 to +60 °C).
1.2.2 Dimensions
Model type Dimension drawing
Screw-type wiring connectors Figure 1-2
I/O cables Figure 1-3
See Figure 3-1 and Figure 3-3 for illustrations of screw-type connectors versus I/O cables.
6 Model 3500 Transmitters or Model 3300 Peripherals - Panel Mount
Figure 1-2: Panel-mount screw-type dimensions
4 1/2 (114)
6 1/2 (165)
Bezel
Panel
6
(152)
Approvals tag
Frame
Intrinsic safety shield
(Model 3500 only)
7 3/4 (197)
1/2
(12)
8 1/2
(216)
6
(152)
inches
(mm)
6 11/16
(170)
6 1/2 (165)
Bezel
Panel
6
(152)
6 11/16
(170)
Minimum 4 1/4"
(108 mm) bend radius
Approvals tag
1/2
(12)
8 3/4 (222)
5 5/16
(135)
Frame
6
(152)
inches
(mm)
Planning
Figure 1-3: Panel-mount dimensions with I/O cables
Installation Manual 7
Planning
Model 3500
4-wire cable
Sensor
Core processor (standard or enhanced)
Sensor
Junction box
9-wire cable
4-wire cable
Model 3500
Core processor (standard only)

1.3 Cable lengths

Maximum cable length from the sensor to the Model 3500 transmitter depends on the installation type and cable type.
Installation type Maximum cable length
4-wire remote transmitter See Figure 1-4, and Table 1-1 for maximum length of the
Remote core processor with remote transmitter
If you are installing the Model 3300 applications peripheral in combination with a transmitter, the maximum cable length between the transmitter frequency output and the Model 3300 frequency input is 500 feet (150 meters).
Figure 1-4: 4-wire remote transmitter
4-wire cable
See Figure 1-5, and Table 1-1 for maximum length of the 4-wire cable and the 9-wire cable
Figure 1-5: Remote core processor with remote transmitter
8 Model 3500 Transmitters or Model 3300 Peripherals - Panel Mount
Table 1-1: Maximum cable lengths between sensor and transmitter
Step 1
Step 2
Step 3
Step 4
Cable type Wire gauge Maximum length
Micro Motion 4-wire Not applicable 1000 ft (300 m) without
Ex-approval
500 ft (150 m) with
IIC-rated sensors
1000 ft (300 m) with
IIB-rated sensors
Micro Motion 9-wire Not applicable 60 ft (20 m)
User-supplied 4-wire VDC 22 AWG (0.35 mm
VDC 20 AWG (0.5 mm2) 500 ft (150 m)
VDC 18 AWG (0.8 mm
RS-485 22 AWG (0.35 mm larger
2
) 300 ft (90 m)
2
) 1000 ft (300 m)
2
) or
1000 ft (300 m)

1.4 Install the Model 3300 or Model 3500 in the panel

Planning
Refer to Figure 1-6 and follow these steps:
1. Insert the Model 3300 or Model 3500 through the cutout.
2. Slide the frame over the housing.
3. Insert the posts on the brackets into the rails on the housing.
4. Tighten the screws evenly to 10 to 14 inch-pounds (1,13 to 1,38 Nm) to ensure a
watertight seal between the gasket and the panel.
Figure 1-6: Panel installation steps
Installation Manual 9