– Web: www.mgftools.comwww.nebulizzare.com
PRESS Testing Pump
User Manual
rev. 2.0 del 08/10/2018
IIntroduction
ntroduction
This manual, supplied with the machine, provides important instructions for the correct installation, use and maintenance of the machine.
Reading this manual and complying with the provisions contained therein are necessary conditions for the validity of the warranty and for the correct and safe operation of the system.
It is the responsibility of the customer to keep this manual, to provide adequate instructions to any user for the correct use of the system.
The manual is available for download in its latest update at www.mgftools.com
The manufacturer declines all responsibilities for damage caused by negligence and failure to observe the rules described in this manual.
Purpose of use
Purpose of use
This pump has been engineered for small transplanting and fillings and for plants test with water. The pump can work with
all kind of liquid with a maximum viscosity of 1.5 m Pa s and with water solutions with PH between 7 and 12.
MGF
MGF refuses every responsibility for damages or bad working if the pump is used incorrectly, for a purpose for which it
was not intended or is tampered.
General Informations
General Informations
Art. Modello
905200 PRESS Testing Pump 60 bar 230V
905250 PRESS Testing Pump 60 bar 115V
300020* Unclogging pipe
*Additional accessory not supplied as standard
STANDARD SUPPLY
MGF
MGF Press Test pump
1/2" high pressure hose (art.300002)
Suction hose with fitting and filter (art. 960002)
Use and maintenance manual
2
MGF
MGF srl –– Via Chico Mendes, 8 – 43055 Mezzani (PR) ITALY – Tel. +39 0521-818301 – Fax +39 0521-818202
E-mail:info@mgftools.com
– Web: www.mgftools.comwww.nebulizzare.com
TECHNICAL CHARACTERISTICS:
Weight: 13,2 Kg Dimensions: 200 x 440 x 320 mm Max. Pressure: 60 bar Max. Flow Rate: 7 L/min (420L/h) High pressure hose: 1/2” G F - 1500mm Voltage: 230 V ~ 50Hz / 115 V ~ 60Hz Power: 1750W Service class: S1 Insulation class: IPX5
TECHNICAL DATA
Locate the identification plate on the machine and check that the plate data given in it are in conformity with the contents of the present table. The nameplate data must be respected during all the foreseen operations.
SERVICE
For any form of technical assistance you can contact us in one of the following ways:
telephone: +39 0521/818301 fax: +39 0521/818202 email: assistenza@mgftools.com
We will serve you as soon as possible. The shipment of material under repair must be previously authorized by means of the RMA form (binding condition for the collection of any goods under repair).
WARRANTY TERMS
The product warranty covers any manufacturing defect for a period of time equal to one (1) year from the date of manufacture for products purchased with invoice, 2 years for products purchased by private individuals. The following clauses expressly exclude the product from guarantee:
Consumables such as pipes, impellers ..., to the extent that the malfunction is caused by normal wear and tear of the
parts.
Malfunctions caused by use not in accordance with the instructions provided
Poor maintenance
Tampering with or modifying the machine
The company excludes from its responsibility any indirect damage, damage caused to people and things from defects and downtime, incorrect use, lack of maintenance.
3
MGF
MGF srl –– Via Chico Mendes, 8 – 43055 Mezzani (PR) ITALY – Tel. +39 0521-818301 – Fax +39 0521-818202
E-mail:info@mgftools.com
– Web: www.mgftools.comwww.nebulizzare.com
Warnings
Warnings
Read all safety instructions, operating and maintenance instructions, and the technical data of this electric tool.
Failure to follow the instructions may cause electric shock, fire and / or serious injury.
Keep all safety warnings and instructions for future use.
1. Safety of the working environment
1. Keep the workplace clean and well lit. Disorder and a poorly lit workplace can cause accidents.
2. Do not work in explosive atmospheres (ATEX) where flammable liquids, gases or powders are found. The machine can generate sparks that can ignite dust or steam.
3. Keep children and other people away when using the machine. Hazardous situations can be created both under normal and unintended conditions.
2. Electrical safety
1. The electrical socket to which the machine is connected must be adapted to the machine plug. The plug must enter effortlessly.
2. The electric plug must not be changed in any way. Do not use adapters for grounded power tools. Unmodified plugs and adequate sockets reduce the risk of electric shock.
3. Avoid contact with grounded objects such as pipes, radiators, ovens and refrigerators. The risk of electric shock occurs if the user is in contact with conductive materials.
4. Keep the machine away from rain, moisture and liquid jets. Water infiltration increases the risk of electric shock.
5. Do not use the power cord for a purpose other than intended, to carry the machine, to hang it or to remove the plug from the socket. Keep the power cord away from heat, oil, sharp edges or moving objects. Damaged or entangled cables increase the risk of electric shock.
6. If you work outdoors, use only extension cords that are also suitable for outdoor use. The use of an extension cable suitable for outdoor use reduces the risk of electric shock.
7. Make sure that the socket is protected by a differential switch (circuit breaker). The use of a fault current safety switch reduces the risk of electric shock.
3. People safety
1. Working paying attention and with awareness.
2. Do not work when you are tired or under the influence of drugs, alcohol, medicines or psychotropics. Working exclusively in full psycho-physical capacity can avoid serious injuries.
3. Wear personal protective equipment as directed. Personal protective equipment, such as a dust mask, non­slippery safety shoes, protective helmet and hearing protection, depending on the type and use, reduces the risk of injury and permanent damage.
4. Avoid accidental starting. Check that the machine is switched off before connecting it to the power supply and / or the battery, and any operation that does not require ignition, such as transport and maintenance. Accidental starts can cause serious accidents.
5. Remove adjusting tools or keys before turning on the machine. Fix all the protections and moving parts correctly. Moving parts that are not properly protected can cause damage to people and property.
6. Avoid improper posture. Make sure you are in a stable position and always maintain balance. Avoid working on slippery floors. In this way it is possible to react better in case of unforeseen situations.
7. Dress appropriately. Do not wear loose clothing or jewelry. Keep hair and clothing away from moving parts. Anything that can get caught up in moving parts, even if partially protected, can cause serious damage and injury.
4