MGE UPS Systems EX20Rack, EX30Rack User Manual

Pulsar
TM
EX20
User Manual
!
+
+
%
%
Rack
/ EX30
Rack
www.mgeups.com
Thank you for purchasing the EX
Rack
Uninterruptible Po wer Supply. The EX
Rack
has been designed to provide many years of trouble-free operation. Please review the manual which has been prepared to provide you with all the necessary information concerning the installation and use of your EX
Rack
. For service call 1-800-523-0142. Sincerely,
MGE UPS SYSTEMS
Federal Communications Commission (FCC) Statement
Note: this equipment has been tested and
found to comply with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when equipment is operated in a residential environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits.
Pulsar EX
Rack
: 86-153500-00Revision A00 ECN - 000071
MGE UPS SYSTEMS
IMPORTANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS
This manual contains important instructions for Models EX20Rack / EX30Rack / EXB20/30 that should be followed during installation and maintenance of the UPS batteries.
c This equipment can be operated by any individual, with no previous training; c CAUTION: Risk of electric shock, even with unit disconnected from AC power source. Hazardous voltage still may be present through operation from battery. The battery supply should be disconnected at the plus and minus terminals using the quick disconnect connectors of the battery when maintenance or service work inside the UPS is necessary.
c The UPS contains voltages which are potentially hazardous. All repairs should be performed by qualified service personnel only; c do not attempt to power the UPS from any receptacle other than a 2-pole 3-wire grounded receptacle;
c do not place Pulsar near water or in environment of excessive humidity; c do not allow liquids or any foreign objects to get inside Pulsar; c do not block air vents in front or back of Pulsar; c do not plug household appliances such as hair dryers to Pulsar receptacles; c do not place Pulsar in direct sunlight or close to a heat-emitting source;
MGE UPS SYSTEMS
c the AC power receptacle should be near the equipment and easily accessible. To isolate Pulsar from AC input, remove the input power cord from the AC power receptacle; c if Pulsar is to be stored for a long time, it is recommended to recharge the batteries (by connecting AC power source to Pulsar, switch "ON" or "OFF"), once a month for 24 hours to avoid a full battery discharge; c Pulsar contains batteries that should be disposed of or recycled in accordance with local applicable laws; c prior to installation, store Pulsar in a dry location; c storage temperatures must be between –4°F (-20°C) and +113°F (+45°C); c servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries; c when replacing the batteries, use the same number and the following type of batteries:
v Pulsar EX20 v Pulsar EX30
c ~ : alternating current supply symbol;
Pulsar EX
Rack
: 8 x 12V - 7.2Ah,
Rack
: 8 x 12V - 7.2Ah;
Rack
: 86-153500-00
c CAUTION: do not dispose of battery or batteries in a fire. The battery may explode; c CAUTION: do not open or mutilate the battery or batteries, released electrolyte is harmful to the skin and eyes. It may be toxic; c CAUTION: a battery can present a risk of electric shock and high short circuit current. The following precautions should be observed when working with batteries: v remove watches, rings or other metal objects,
v use tools with insulated handles, v wear rubber gloves, boots and safety
glasses; c please dispose of the packaging in accordance with applicable laws.
i
introduction
In critical situations, count on MGE UPS SYSTEMS Pulsar EX20
EX30
Rack
uninterruptible power supplies (UPS). Their protection keeps your data intact and accessible.
Pulsar EX20
Rack
ensure top quality power around the clock, and continue operations during power failures. An intelligent microprocessor detects any operating anomalies of the UPS and triggers an alarm if corrective action is necessary. In addition to the high-technology aspect of these UPSs, you can count on backup from our staff, a team of specialists, around the corner from you, throughout the world. It’s no accident that MGE UPS SYSTEMS is the world leader in UPS protection. The UPS provides power factor correction to reduce harmonic distortion and current created by non-linear critical loads from polluting the incoming AC line.
UPS includes:
c batteries, c power factor correction / battery charger, c DC to DC converter, c DC to AC inverter, c bypass switch, c input/output filters.
The MGE Pulsar UPS is capable of providing the following modes of operation: c ON LINE MODE which is the primary mode of operation in which the critical load is continuously supplied by the inverter and protected from all forms of power line disturbances:
Rack
and EX30
and
Rack
UPSs
AC
IN
EMI filter
power
factor
corrector
rectifier
charger
DC / DC
micro
control and
DC to AC
inverter
monitored
batteries
critical
system
c BYPASS MODE which is a default mode in the event of an inverter failure or overload in which the critical load is supplied AC through EMI/RFI filter:
AC
IN
EMI filter
power
factor
corrector
rectifier
charger
DC / DC
uses of Pulsar EX20 EX30
Rack
:
micro
control and
DC to AC
inverter
monitored
batteries
Rack
and
critical
system
Network servers and interconnection devices are very sensitive to electrical disturbances of all types, including outages, voltage sags, brownouts, spikes, etc. The origins of the disturbances also vary, ranging
from atmospheric phenomena, to nearby devices generating interference such as elevators, photocopy machines and machine tools, not to mention human errors, like the accidental pulling out of power cords or tripping of circuit breakers. The consequences of these disturbances on computer systems range from data losses to hardware damage (power supplies, hard disks).
Pulsar EX20
Rack
and EX30
Rack
are specially designed to protect network servers and all other interconnection devices that are sensitive to electrical disturbances.
Pulsar EX20
Rack
and EX30
Rack
add fault­tolerance to the utility supplying your sensitive equipment.
Pulsar EX20
Rack
and EX30
Rack
are designed as compact units and feature very quiet operation.
Pulsar EX20
Rack
and EX30
Rack
provide a stable supply of clean power, long back-up time during a utility outage (see table) and vast information and control possibilities according to the configuration selected.
Pulsar EX20
Rack
and EX30
Rack
On-Line technology provides maximum protection and availability of workstations, servers, and network communication devices.
Pulsar EX20
Rack
and EX30
Rack
offer many functions and characteristics designed to simplify power management: c automatic battery test carried out periodically. In the event of a fault, a LED provides advance warning for battery replacement; c front panel LEDs signal all types of faults and alarms;
ii
Pulsar EX
Rack
: 86-153500-00 MGE UPS SYSTEMS
c Bar graph continuously indicates the battery charge level or the critical load power level;
c Pulsar EX20
environment friendly: all components are recyclable and an electronic power-saver device reduces power consumption if the UPS is not active for a period exceeding 5 minutes while on battery back-up; c EX Driver software provides rapid startup of Pulsar EX20 the EX Tuner configuration module. This module adapts Pulsar EX20
EX30
Rack
frequency, startup and shutdown sequences, setting of battery thresholds, etc.). See "communication" section for further details; c Solution-PacTM is a CD-ROM which contains all the tools needed to supervise your UPS. c Simply download the EX driver utility from the CD and Solution-Pac. The UPS must be serialy connected to a Windows PC.
Rack
and EX30
Rack
and EX30
to user preferences (battery test
Rack
Rack
Rack
are
using
and
options
c UM Sensor environment measurement unit: compatible with SNMP or Solution
PacTM, this unit measures the temperature and the relative humidity in the room where the Pulsar is installed. Eight relay contacts are provided to transmit signals to an administration platform, in the form of voltage-free contacts to enable monitoring of (fire alarm, climate control fault, intrusion, etc.);
c battery extension module: Pulsar EXB20/30 battery extension modules lengthen the battery time of the Pulsar EX20
Rack
/EX30
Rack
requirements. For rack installation of EXB20/ 30 order 19" rack kit P/N 8907U. c output transformer: input line cord plugs into the Pulsar EX30 receptacle. Rating is 120V AC input, 208V/ 240V AC 2.75 kVA output; c maintenance bypass switch: enables the user to continue supplying ac power to the load while performing routine or emergency maintenance.
to meet your
Rack
output
additional communications options:
c SNMP administration: MGE has the most complete offering for the administration of a group of UPSs using the SNMP protocol with different network-connection modules (SNMP card or proxy software), supervision modules (application for NMS platforms such as HP OpenView or C.A. UNICENTER TNG) and a file-closing module (UM Client). c SNMP card: this card, inserted into your unit, can establish a direct Ethernet network connection for your UPS. It can then be temporarily managed using SNMP or the various software modules of Solution-Pac. The MGE UPS SYSTEMS offering complies with RFC 1628 specifications (IETF) and was certified by the InterWorking Labs during the Test Summit in June 1994; c status information card: this option provides you with 5 voltage-free contacts: on battery, on by-pass, low battery, load on UPS. This card can be used with the UPS driver of IBM AS/400.
Contact your dealer for further information on these options.
MGE UPS SYSTEMS
Pulsar EX
Rack
: 86-153500-00
iii
software supplied with Pulsar EX20 EX30
Rack
To meet the different operating environments of your UPS, Pulsar EX includes 2 MGE UPS SYSTEMS software programs:
c EX-Driver software for Windows c Network based Solution-PacTM power
management software
EX-Driver for Windows
EX Driver for Windows provides communication with the UPS from a simple Windows workstation. EX-Driver is compatible with Windows 3.1x and Windows 95/98, for communication with the UPS via a serial connection for various needs:
c personalization of the UPS operating mode: the EX-Tuner utility, can be used to
change certain UPS operating parameters if the standard factory settings are not ideal for the operating conditions. It is possible to modify the output voltage, battery-test frequency, startup and shutdown sequences, operation of automatic by-pass, etc.;
Rack
and
Rack
Solution-PacTM for networks and multi-server systems
Protection by UPS is only complete and effective if combined with powerful software functions which warn users and the operator of any power supply problem, automate system shutdown, supervise and remotely control the UPSs. MGE UPS SYSTEMS created Solution-PacTM for this purpose. Solution-PacTM combines all these functions in a single CD-ROM, usable in local or remote mode (TCP/IP and SNMP), and covering the main network environments. Solution-PacTM is the ideal solution for protecting networks and multiserver systems. Solution-PacTM on a single CD-ROM contains everything needed to safeguard one or more systems and to supervise one or more UPSs from a local or remote station. Solution-PacTM includes SNMP proxy agents, system shutdown software, and supervision software.
Solution-PacTM is a powerful and upgradable software tool which provides all the supervision, control and safety functions associated with a UPS:
v graphic display of the UPS, v remote control of the UPS and output
receptacles,
v user alarm of problems, v recording of events in log files, v automatic system shutdown and restart, v local or remote supervision of UPSs and
ancillary devices, v transmission of UPS information and alarms to any SNMP supervisor.
v paging / e-mail capabilities v multiple server shutdown in
heterogeneous environment.
Platforms supported:
Windows 3.1, 95, 98, NT, Novelle Netware, OS/2, Linus, Mac/OS, Sun Solaris, HP/UX, IBM Aix, Dec Unix and Open VMS, Silicon Graphics, IRIX.
iv
Pulsar EX
Rack
: 86-153500-00 MGE UPS SYSTEMS
general contents
Pulsar presentation............................................................................................................................. 3
getting started / operation....................................................................................................... 11
Pulsar EX20
Rack
/ EX30
Rack
/ EXB20/30 presentation
MGE UPS SYSTEMS
Pulsar EX
Rack
: 86-153500-00
1
MGE UPS SYSTEMS
Pulsar EX
Rack
: 86-153500-00
2
7b
5
7a
9
12
11
10
7c
6
13
8
7a
Pulsar EX20 front view
Rack
/ EX30
Rack
Pulsar EX20 rear view
Rack
1f
1e 1c
2
!
+
3
%
+
%
1a
1b 1d
3
Pulsar EX
Rack
: 86-153500-00
MGE UPS SYSTEMS
4
Pulsar EX
Rack
: 86-153500-00
MGE UPS SYSTEMS