Metz 2006 User Manual

Press Information
photokina 2006
f Metz mecablitz 54 MZ-4i digital:
The all-rounder
The perfect flash with analogue and digital cameras from completely different manufacturers – that’s the strength of the
Metz mecablitz 54 MZ-4i digital. By integrating high-precision flash modes, optimally illuminated pictures with brilliant and well­defined colours are achieved. Simply by changing the adapter, interesting flash modes are available depending on the camera type, including Canon E-TTL and E-TTL II, Nikon i-TTL and ADI flash control from Konica/Minolta/Sony. Naturally, the SCA system supports various other connection options to nearly every system camera including the models that meet the “four thirds” standard. Especially worth mentioning is the secondary reflector of the 54 MZ-4 i digital, as is its easy-handling with a large display, two function keys and a thumb wheel.
made in Germany
Metz mecablitz 54 MZ-4 i digital: high light output – guide number 54 at ISO 100/21° and 105 mm focal length. Large illumination angle – illumination of a focal length range of 20-105 mm (with integrated WA diffuser). The set includes a SCA adapter, currently for Canon, Konica/Minolta/Sony Alpha, Nikon, Olympus and soon also available for Pentax cameras.
Metz-Werke GmbH & Co KG Corporate Communications Ohmstrasse 55 90513 Zirndorf Germany Further information Company: Matthias Moschner Products: Kristina Söder Tel.: +49 (0) 911 / 97 06-239 Fax: +49 (0) 911 / 97 06-233 E-mail: presse@metz.de
di gi t al
Ultra-fast shutter speeds
With the high-speed synchronisation (HSS) of the Metz mecablitz 54 MZ-4i digital, flash lighting can be achieved with times that are even shorter than the camera synchronisation times (depending on camera type). Important for brightening shadowy areas of a portrait, while at the same time silhouetting the subject against an out-of-focus background.
Without flash With flash and HSS
The Metz public relations department looks forward to receiving your specimen copy: presse@metz.de Download images and text at www.metz.de/presse
Metz mecablitz 54MZ-4i digital
SCA – system flash unit for analogue and digital cameras
Maximum guide number at ISO 100 / 21° and max. zoom 54 Guide number at ISO 100 / 21° and 50 mm 40 Standard equipment and functions Swivel main reflector with motor-zoom 24 – 28 – 35 – 50 – 70 – 85 – 105 mm (135 format)
rotation range Integrated wide-angle diffuser for illumination from 20 mm (135 format) • Optional secondary reflector for standard flash modes • Illuminated LC display, e.g. displays flash mode, range, flash parameters etc. • LED display for flash ready/ exposure control • / • Optional acoustic status signal (beep function) • Metering function • Manual key-lock function) • Reset function (resets to factory settings) • Optional, energy-saving auto-off
vertical in ° -7 / +90 Swivel reflector­horizontal in ° 270
Standard flash modes
Standard TTL flash mode Automatic flash mode with 12 tele-computer apertures Manual flash mode with 25 partial power levels Stroboscopic flash mode Fill-in flash mode
Dedicated flash modes and functions
Automatic flash synchronisation control - • Display in viewfinder for flash ready / exposure control - / - • / • • / • Automatic / manual flash range display in viewfinder - / • - / • • / • Automatic / manual aperture adjustment - / • - / • • / • Automatic / manual ISO setting - / • - / • • / • Automatic / manual motor-zoom control - / • - / • • / • Extended zoom mode
Picture format adjustment Automatic AF-metering flash control
Synchronisation on the 1st or 2nd shutter curtain (REAR) Slow synchronisation (SLOW) -
High-speed synchronisation (HSS) Flash exposure correction with TTL / automatic - / • - / • • / •
Flash exposure series with TTL / automatic - / • - / • • / • Pre-flash function minimising red-eye effect (Nikon, Olympus, Pentax)
Off-camera Metz TTL / automatic remote flash mode - / • • / • • / • Controller flash mode in the wireless Metz remote system Slave flash mode in the wireless Metz remote system with slave adapter SCA3083 digital
Flash unit wake-up function via camera
Canon E-TTL / E-TTL II flash mode
Canon FE flash exposure memory for E-TTL / E-TTL II
Minolta-Konica, Sony ADI metering / pre-flash TTL
Nikon matrix-controlled fill-in flash lighting
Nikon 3D multi-sensor fill-in flash lighting
Nikon D-TTL- / D-TTL-3D flash mode
Nikon i-TTL- / i-TTL-BL flash mode
Nikon pre-flash function minimising red-eye effect
Nikon FV flash exposure measurement memory for i-TTL / i-TTL-BL
Nikon under-exposure display in EV
Olympus pre-flash TTL / “four-thirds” system
Standard
mount
SCA 301
- -
- -
-
- -
- -
- -
-
- / - - / -
- / - - / -
- / - - / -
- -
- -
- / - - / -
- / - - / -
- -
- / - - / -
- -
- / - - / -
System
SCA300
System
SCA3002
• / •
• / •
• / •
• / •
• / •
• / •
• / •
Power supply
Battery operation: alkaline 1.5V / lithium 1.5V • / • Rechargeable battery operation: NiCd 1.2V / NiMH 1.2V • / • Optional external power supply: Power Pack P76 / P40 • / •
4 Mignon batteries (AA)
Other
Weight with power source Approx. 480 g Dimensions (W x H x D) Approx. 75 x 125 x 108
Lots of additional flash functions are available when using the mecablitz 54 MZ-4i digital with an SCA 3002 or SCA 300 system adapter.
Availability depends on the respective camera system (camera manufacturer), the specific camera type and the SCA adapter. More detailed information at www.metz.de or in the relevant SCA adapter user guide.