Mettler Toledo XPE, XPE105, XPE205, XPE205DR, XPE204 Quick Manual

...
www.mt.com
XPE204
F
F
METTLER TOLEDO
StaticDetect
Quick Guide
XPE Models

Table of Contents

Introduction1 5
Safety Information2 6
Design and Function3 8
Installation and Putting into Operation4 18
Maintenance5 26
Technical Data6 27
Explanation of warnings and symbols2.1 6 Product safety information2.2 6
Overview3.1 8 Balance3.1.1 8 Terminal3.1.2 10
User interface3.2 12 Display3.2.1 12 Input dialog boxes3.2.2 13 Text and number entry3.2.2.1 13 Firmware3.2.3 13 User profiles3.2.3.1 14 User-specific settings3.2.3.2 14 Applications3.2.3.3 15 Application-specific settings3.2.3.4 15 System settings3.2.3.5 16 Security system3.2.4 17
Unpacking4.1 18 Scope of delivery4.2 19 Location4.3 20 Assembling the balance4.4 20 Connecting the balance4.5 22 Setting up the balance4.6 23
Weighing for the first time4.6.1 23 Switching on the balance4.6.1.1 23 Leveling the balance4.6.1.2 23 Performing a simple weighing4.6.1.3 24 Operating the glass draft shield4.6.2 24
Cleaning5.1 26
General data6.1 27 Explanatory notes for the METTLER TOLEDO AC adapter6.2 27 Model-specific data6.3 28 Dimensions6.4 31
Table of Contents 3
1Introduction
Thank you for choosing a METTLER TOLEDO balance.
This balance offers numerous weighing and adjustment options with exceptional operating convenience.
METTLER TOLEDO is a leading manufacturer of balances for laboratory and production use as well as analyti cal measuring instruments. A globally present customer service network with highly trained personnel is always available to assist with the selection of accessories or provide advice on the optimal use of the balance.
Various models offering different performance features are available. Models offer different weighing ranges and resolutions. Special reference is made to these features in these instructions if important for operation.
All XPE line models offer the following features:
StaticDetect for detection of electrostatic charges
Glass draft shield with motorized opening for precise weighing even in unstable environments.
Fully automatic adjustment "ProFACT" using internal weights.
Built-in level sensor, illuminated level indicator and Leveling Assistant for fast and easy leveling.
Built-in applications for normal weighing, statistics, formulation, piece numbers, percent weighing, density determination, differential weighing, pipette test and titration.
Integral RS232C interface.
Slot for second interface (optional).
Touch-sensitive graphic terminal ("Touch screen") with color display and status indicator.
Two programmable sensors for hands-off operation ("SmartSens") to speed up frequently recurring tasks.
The balance conforms to current standards and directives. It supports requirements, work techniques and proto cols as specified by all international quality assurance systems, e.g. GLP (Good Laboratory Practice), GMP (Good Manufacturing Practice). The balance has a CE Declaration of Conformity and METTLER TOLEDO, as the manufacturer, is certified to ISO 9001 and ISO 14001. This provides the assurance that your capital investment is protected in the long term by high product quality and a comprehensive service package (repairs, mainte nance, servicing, adjustment service).
Finding more information
u www.mt.com/excellence
Detailed operating instructions are on the CD-ROM.
Software version
These operating instructions refer to the originally installed firmware (software) version V 1.00.

5Introduction

2Safety Information
2.1Explanation of warnings and symbols
Safety notes are indicated by signal words and warning symbols and contain warnings and information about safety issues. Ignoring safety notes can lead to personal injury, damage to the instrument, malfunctions and erroneous results.
Signal words
WARNING for a hazardous situation with medium risk, possibly resulting in severe
injuries or death if not avoided.
CAUTION for a hazardous situation with low risk, resulting in damage to the device or
the property or in loss of data or minor or medium injuries if not avoided.
Attention (no symbol)
for important information about the product.
Note (no symbol)
for useful information about the product.
Warning symbols
General hazard Electrical shock
Mandatory signs

2.2Product safety information

Intended use
Your balance is used for weighing. Use the balance exclusively for this purpose. Any other type of use and operation beyond the limits of technical specifications without written consent from Mettler-Toledo AG, is con sidered as not intended.
It is not permitted to use the instrument in explosive atmosphere of gases, steam, fog, dust and flammable dust (hazardous environments).
General safety information
This balance complies with current industry standards and the recognized safety regulations; however, it can constitute a hazard in use. Do not open the balance housing: The balance contains no user-serviceable parts. In the event of problems, please contact a METTLER TOLEDO representative.
Always operate and use your instrument only in accordance with the instructions contained in this manual. The instructions for setting up your new instrument must be strictly observed.
If the instrument is not used according to these Operating Instructions, protection of the instrument may be impaired and METTLER TOLEDO assumes no liability.
Gloves must be worn
Staff safety
These operating instructions must be read and understood before using the balance. These operating instruc tions must be retained for future reference.
The balance must not be altered or modified in any way. Only use METTLER TOLEDO original spare parts and accessories.
6 Safety Information
Safety notes
WARNING
Risk of electric shock
Use only the original universal AC adapter delivered with your balance, and check that the voltage printed on it is the same as your local power supply voltage. Only plug the adapter into a socket which is grounded.
CAUTION
Damage to the balance
a) Only use indoors in dry locations.
b) Do not use pointed objects to operate the keyboard!
The balance is of a very sturdy design, but is still a precision instrument. It must be han dled with care.
c) Do not open the balance:
The balance contains no user-serviceable parts. In the event of problems, please contact a METTLER TOLEDO representative.
d) Only use METTLER TOLEDO original accessories and peripheral devices for the balance.
These are specifically designed for the balance.
7Safety Information
3Design and Function
www.mt.com
XPE204
F
F
METTLER TOLEDO
StaticDetect
1
4
2
3
5
6
9
8
3
10
611
12
13
14
7
15
This section describes the balance, operating and indicating elements of the terminal and the operating concept of the balance firmware.
3.1Overview
3.1.1Balance
Front view
1 Terminal 2 Display 3 Operating keys 4 SmartSens sensors 5 StaticDetect drip tray for detection of electro
static charges
6 Handle/coupling element for operation of the
draft shield doors
7 StaticDetect light 8 Type designation 9 Glass draft shield 10 Handle for operation of the top draft shield
11 Guide for top draft shield door and transport
door
12 Removable clips for feeding cables or hoses
handle
13 Level indicator/Level sensor 14 SmartGrid weighing pan 15 Status indicator

8 Design and Function

6
7
8
5
4
3
2
1
Rear
1 Aux 1 (connection for "ErgoSens", hand or foot
switch)
2 Aux 2 (connection for "ErgoSens", hand or foot
switch)
3 RS232C serial interface 4 Slot for second interface (optional) 5 Socket for AC adapter 6 Fastening point for anti-theft device 7 Foot screw 8 Cooling element (model dependent)
9Design and Function
3.1.2Terminal
13
12
10
11
1
2
3
4
5
6
1
2
7
8
9
6
Key assignments and terminal connection.
Front view
Designation Explanation
1 SmartSens Two hands-free sensors.
Both of these hands-free sensors can be assigned a specific function (e.g. zeroing, printing or display resolution adjust ment). See settings for SmartSens and ErgoSens in the respective applications.
A specific function can be activated by moving the hand over the respective sensor (maximum distance about 5 cm). The sensor beeps to confirm that it has recognized the command.
2 Status bar The green icons in the status bar indicate the functions assigned
to the SmartSens left or SmartSens right. The F symbol repre sents a function key. SmartSens is deactivated when no green symbol is illuminated.
The yellow LED at the bottom of the status bar lights up briefly when a key is selected or a menu function is initiated.
3 Home This key is used to return to the user profile Home from any
4 User profile This key is used to display a specific user profile. Different set
5 Settings for user pro
files
menu level in any application.
tings can be saved in a user profile. This allows the balance to be adjusted to a specific user or weighing task.
For defining basic settings for each user profile. These settings apply to all user applications.
10 Design and Function
6 Open/Close For opening and closing the glass draft shield doors. For conve
nient right and left-handed operation, one of these keys is pro vided on both sides of the terminal.
7 Select application This key is used to select a required application.
8 Configuration For displaying menus for the configuration of a current applica
1 22
tion. The application can be adjusted to a specific task via numerous settings.
9 Print This key is used to transfer data via the interface, e.g. to a print
er. Other devices, e.g. a PC can also be connected. The data to be transferred can be freely defined.
10 On/Off For switching the balance on and off (standby mode).
Note
It is recommended not to disconnect the balance from the power supply unless it is not going to be used for an extended period.
11 Tare This key is used to tare the balance manually (only necessary
for normal weighings). When the balance has been tared, the Net symbol is displayed to indicate that all displayed weights are net.
Note
A negative weight is not permitted. An error message is generat ed.
When the stability detector icon extinguishes (small ring on the left of the weight display), a stable weight is indicated.
The procedure for taring the balance is not the same as for zero ing.
12 Zeroing This key is used for setting a new zero point manually (only
required if the balance is used for normal weighings). After zero ing "Zeroing", all weights (also the tare weight) apply to this new zero point and the following applies: tare weight = 0, net weight (= gross weight) = 0.
13 Status indicator Indicates the current balance status. The status indicator shows
that the balance is ready to use.
Green = balance is ready to use.
Flashing green = balance is busy. Example: Internal adjustment in progress.
Yellow = task pending, balance can still be used. Example: Automatic internal adjustment pending.
Red = balance cannot/must not be used. Example: Balance is not correctly leveled.
Rear
1 System connection (terminal cable) 2 Foot screw
11Design and Function
Loading...
+ 25 hidden pages