METRON PC01, PC02, PC03, PC04, PC05 User Manual

www.eauto.si info@eauto.si +386 51 320 538
USER MANUAL
PC01 AND PC02
METRON EV portable chargers PC01 and PC02 are designed to charge electric vehicles equipped with Type 1 charging sockets (USA/Japan/S.Korea standard) from any standard household outlet (e.g. Schuko) or industrial socket (e.g. 1 or 3-phase CEE sockets). Where’s the in-cable “bulky box”? Metron
portable chargers are truly unique because all the charging station electronics is placed inside Type 1 charging plug itself!
EV PORTABLE CHARGERS
advantage of this design is the fact, that METRON portable chargers don’t have that heavy in-line “bulky box” as others do, what makes them lighter, easier to install/connect and also easier to store in a carrier case. METRON portable chargers also offer the possibility to set desired charging current/power by simply pressing a button.
GET STARTED
First plug the portable charger in the wall outlet. Immediately signal LED starts blinking: number of blinks tells you what is the saved power setting (see the next page). Afterwards LED glows constantly till AC power is present indicating standby/ready status.
When you plug it into the vehicle Type 1 socket it starts blinking slowly, which means the vehicle is charging. When your electric vehicle is fully charged, the LED glows constantly again.
1
SETTING THE DESIRED CHARGING CURRENT/POWER
METRON portable chargers allow user to set desired charging current/power, before being plugged in the electric vehicle Type 1 socket, or even while the vehicle is charging! Procedure is simple:
press and hold the push button: LED switches off immediately
after 5 seconds LED starts blinking slowly
Releasing the push button after a certain number of blinks determines charging
current/power as follows:
Push Button
LED light
PC02PC01
Number of LED blinks Charging current/power
1 6 A / 1,4 kW
2 8 A / 1,8 kW
3 10 A / 2,3 kW
4 13A / 3,0 kW
5 16A / 3,7 kW
Number of LED blinks Charging current/power
1 6 A / 1,4 kW
2 8 A / 1,8 kW
3 10 A / 2,3 kW
4 13A / 3,0 kW
5 16A / 3,7 kW
6 20A / 4,6 kW
7 25A / 5,8 kW
8 32A / 7,4 kW
New charging current/power setting is stored in the memory and it stays the same (even after the power supply is not present anymore) until the next setting change is performed.
STATUS NOTIFICATION BY LED BLINKS
LED STATUS NOTIFICATION
Slow blinking when power supply is applied
Constantly on when not plugged in
Slow blinking when plugged in
Indicating previous saved current setting
Stand-by / Ready to charge
Charging
2